Cisco Switching/Routing :: 6513 / 5000 - Replication Latency / One Way

May 27, 2013

I am looking for any assistance with an issue I am having.  Within my network, I have two Net App enclaves that replicate with each other.  These hang off of separate switches, one at our primary site and one off of our secondary site, just a few miles away.  I can replicate from the primary site to the secondary site at 8GB per minute.  From the secondary site back to the primary site, however, the replication passes at about 17MB per minute.
 
The configuration is exactly the same on both ends.  The primary Net App enclave hangs off of a 6513 switch and the secondary Net App enclave hangs off of a Nexus5000.  Trace routes and pings all show correct paths and connectivity.  I have troubleshoot this for a few days and I have been unable to figure out what is causing the replication issues.  The fact that this is bi-directional traffic and I am having problems one way is really throwing me off.  There are no ACLs or firewalls present between the two switches.

View 1 Replies


ADVERTISEMENT

Cisco Switching/Routing :: Poor Snap Mirror Replication Over WAN Fex 5000

Jan 27, 2013

We have a NETAPP nas box having two interfaces connecting to two fex's on 5ks. The 5ks are inturn connected to nexus 7k boxes. We have a 100mbps man link (LAN Extension). The netapp's two nics are grouped together to form a teaming type of environment. SNAPMirror replication is very poor at the rate 10mbps though the WAN speed is 100mbps and also the wan link is utilized only about 60mbps. What could be the problem. We tried removing storm unicast control 10 but with no effect.

View 1 Replies View Related

Cisco Switching/Routing :: 6513-E / 6513 And WS-X6748-GE-TX Compatibility

Oct 29, 2012

we have a chassis 6513-E and a module WS-X6748-GE-TX, I'd like to know if could I put this module in any slot, since the documentation from Cisco says that any slot from a chassis 6500-E Series can support this module. And then in the documentation of WS-X6748-GE-TX says that this module is not compatible in the slots 1-8 of the 6513 chassis, only from 9th to 13th slots, in those slots from the 6513-E we already have 4x WS-X6748-GE-TX, and we'd like to know if could we put the module in the rest of the slots. The 6513, and 6513-E is kind of confusing.

View 4 Replies View Related

Cisco Switching/Routing :: 2960s / Marking The Traffic Between Two Hosts (Data Replication)

Feb 6, 2013

in switch 2960s ( c2960s-universalk9-mz.122-55.SE5 ) , i want to marking the traffic between two hosts (Data replication), i choose to use " mac access-list"  to classify my trafic before apply the policy marking . but did'nt work . c

!  my mac ACL
mac access-list extended test
permit host 000a.1a41.aa52 host 000a.1a41.1bc2
!
class-map match-all test
match access-group name test

[code]....

View 4 Replies View Related

Cisco Switching/Routing :: Facebook Forum Data Center Switching With Nexus 5000

Oct 8, 2012

Lucien is a customer support engineer at the Cisco Technical Assistance Center. He currently works in the data center switching team supporting customers on the Cisco Nexus 5000 and 2000. He was previously a technical leader within the network management team. Lucien holds a bachelor's degree in general engineering and a master's degree in  computer science from Ecole des Mines d'Ales. He also holds the  following certifications: CCIE #19945 in Routing and Switching, CCDP, DCNIS, and VCP #66183

View 1 Replies View Related

Cisco Switching/Routing :: Nexus 5000 LAN Routing Connection Deployment

May 16, 2013

We have our Nexus as our default gateway (101.1) and the default VLAN1 is setup with two subnets 101.X and 102.X. The DHCP server is using a superscope setup to accomodate the overflow of devices requesting IPs on 101, so when 101 is consumed persons are able to obtain a 102.X IP address. The setup is basic on superscope. The issue is some times the routing to the firewall with a 102.X is not always 100%. Somedays all goes well and the 102 subnet is routed out to the firewall and its a good day. However, such as today a 102.X address is not routing as it did 24 hours ago. I am perplexed as to why this is behaving unpredicatable. Here is running-config for VLAN1 to show the 102 as secondary address to VLAN1.

View 2 Replies View Related

Cisco Switching/Routing :: Surges In Nexus 7010 Latency

Dec 2, 2011

I just deployed a nexus 7010 switch at a server farm. after deployment, it was notices that there are surges in latency across the network. The default gateway was then moved to the nexus, with this pinging from an host on the same subnet there is intermitent burst is latency

NEXUS>>>>>Server
Ping of about 80ms and sometimes even times out.
To me, this is strange.
NX-OS Version is 5-02a

View 1 Replies View Related

Cisco Switching/Routing :: Switch 4507 Having High Latency / CPU

Aug 19, 2012

We are facing issue of high Latency and slowness with Switch Cisco 4507R at the Customer site.show logging for the Switch and if there is any IOS related issue [BUG] or some other finding for this case.

View 1 Replies View Related

Cisco Switching/Routing :: RFC 2544 Latency Of IE3000 Device

Feb 12, 2013

I'm finding information about the RFC 2544 latency of the IE3000 device.Does it exist a document containg latency value measured in relation to packet dimension?

View 0 Replies View Related

Cisco Switching/Routing :: Nexus 5000 Tacacs

Oct 8, 2012

I have a little problem. My customer is using TACP-PLUS ALPHA (F4.0.3.alpha.v9). Well, the same user than have access to another Cisco equipment, with user test1 by sample, can configure anything in the equipment. But in the nexus 5000, el command "show user-account" indicate just the "network-operator" role. Well, I patch this situation with the next commands:

aaa authorization config-commands default group TACSERVER local
aaa authorization commands default group TACSERVER local
 
Well, when I do a telnet into the nexus, I can shut the interfaces, config and anything. But, when I ingress by console, I can not to configure the interfaces.I understand that the Nexus 5000 the Tacacs configuration is global for VTY and Console (different in the Cisco equipment Routers by sample).

View 1 Replies View Related

Cisco Switching/Routing :: ACS Authorization On Nexus 5000

Jun 23, 2012

I have the following configured on my Nexus switches and works with success.
 
The problem I have is Once I switch of the ACS server I can log on to the Nexus as I have a admin user configured locally on the Nexus and the ACS server unfortunately can not run commands as it tries to point to the ACS server for auhtorization and the ACS server is turned off is it possible for the Nexus to ignore the authorization command if it can not see the ACS server ?
 
Feature tacacs+
ip tacacs source-interface vlan 705
tacacs-server host x.x.x.x key 7 "xxxxxx"
aaa group server tacacs+ Test-switch (Test-switch is a group configured on ACS 5.2)
[Code]...

View 1 Replies View Related

Cisco Switching/Routing :: Nexus 5000 - What Cause Loops On Ports

Dec 14, 2011

Any opinion on what could cause loops on nexus 5000 ports that are connected to esx hosts ?

View 3 Replies View Related

Cisco Switching/Routing :: Nexus 5000 Upgrade Really Non-disruptive?

May 15, 2013

I'm planning to upgrade N5K from 5.1(3)N2(1b) to 5.2(1)N1(4)."sh install all impact kickstart bootflash:n5000-uk9-kickstart.5.2.1.N1.4.bin system bootflash:n5000-uk9.5.2.1.N1.4.bin"reports:

...
Compatibility check is done:
Module bootable         Impact Install-type Reason
------ -------- -------------- ------------ ------
     1       yes non-disruptive         reset
...

Is the upgrade really non-disruptive?

View 1 Replies View Related

Cisco Switching/Routing :: VPC On Nexus 5000 With Catalyst 6500 (no VSS)?

Jan 23, 2011

The diagram below is the configuration we are looking to deploy, that way because we do not have VSS on the 6500 switches so we can not create only one  Etherchannel to the 6500s.Our blades inserted on the UCS chassis  have INTEL dual port cards, so they do not support full failover.
 
Questions I have are.

- Is this my best deployment choice?
- vPC highly depend on the management interface on the Nexus 5000 for the keep alive peer monitoring, so what is going to happen if the vPC brakes due to:
- one of the 6500 goes down
- STP?
- What is going to happend with the Etherchannels on the remaining  6500?
- the Management interface goes down for any other reason
- which one is going to be the primary NEXUS?
 
Below is the list of devices involved and the configuration for the Nexus 5000 and 65000. 
 
Devices

·         2  Cisco Catalyst with two WS-SUP720-3B each (no VSS)
·         2 Cisco Nexus 5010
·         2 Cisco UCS 6120xp
·         2 UCS Chassis
     -    4  Cisco  B200-M1 blades (2 each chassis)
          - Dual 10Gb Intel card (1 per blade)
 
vPC Configuration on Nexus 5000
 
TACSWN01
TACSWN02
feature vpc
vpc domain 5
reload restore
reload restore   delay 300

[code]...

View 22 Replies View Related

Cisco Switching/Routing :: SNMP / Does Nexus 5000 Support VRF

Jan 7, 2013

Iam having some issue trying to configure snmp-server context vrf XXX.From some reason even if i put my VRF name i cant see anything about this vrfthis is the command i add:
 
 snmp-server context def vrf datacenter

View 3 Replies View Related

Cisco Switching/Routing :: Nexus 5000 Jumbo Packets?

Oct 7, 2012

on some of our ports on Nexu 5000 and on the connected FEX we can see a lot of Jumbo Packets though there is not enableed any JumboFrame on the Switch, all Interface and system MTU is set to 1500.
 
DBE-LINZ-XX41# sh int Eth113/1/27
Ethernet113/1/27 is up
Hardware: 100/1000 Ethernet, address: d0d0.fd1b.b69c (bia d0d0.fd1b.b69c)

[Code]....

View 1 Replies View Related

Cisco Switching/Routing :: Nexus 5000 Jumbo Frames

Apr 16, 2013

We have a requirement to send span traffic to a destination port for monitoring purposes on two 5000s with some 2000 fex boxes attached.
Some of the servers are making use of frames larger than 1500. we have not changed any mtu configuration on the 5000 since installation, and I can see the policy maps is still on 1500.
 
My first assumption would be that frames larger than 1500 will not be dropped, but it seemingly not (see below). is there a reason why the switch would forward jumbo frames? Also, is there a limitation on MTU for span traffic? There is a MTU command under the span session, but the maximum is 1518. From what I can read the frame will be truncated if it exceeds this. Does that mean the fragments will be dropped?
 
RX
    7495685816 unicast packets  249 multicast packets  147899 broadcast packets
    7495833963 input packets  1426823388087 bytes
    1608134 jumbo packets  0 storm suppression bytes
[Code]....

View 1 Replies View Related

Cisco Switching/Routing :: Nexus 5000 Support Of Netflow

Jun 8, 2009

I can't seem to find any information on the Nexus 5000 support of netflow. I assume that means it doesn't do netflow.

View 5 Replies View Related

Cisco Switching/Routing :: 6513 - SSO Functionality

Jan 31, 2012

Well I have been back and forth on this a while now...I have a 6513E chassis that is getting prepped for prod. I am currently testing sso functionality and I can only get it to work using the following images on both Sup Cards.  

s72033-adventerprise_wan-mz.122-33.SXI5.bin
 
If I try any other image, smaller or bigger in size...it forces my Sup card in mod 8 to recycle " proxy request from peer ". I have tried K9 images and non K9 images. Here is an output from sh redundancy.

Redundant System Information :  Available system up time = 4 minutes Switch overs system experienced = 0  Standby failures = 0 Last switchover reason = none [code]...

View 2 Replies View Related

Cisco Switching/Routing :: Connect Nexus 2000 To Two 5000 With Different Links?

Feb 12, 2013

is it possible to connect one Cisco Nexus 2000 fabric extender to two Cisco Nexus 5000 and use one link on the first side and two links on the other side?

View 3 Replies View Related

Cisco Switching/Routing :: Setting Up Nexus 5000(s) For Inband Management?

Feb 12, 2012

we do not have an out-of-band management network and setting one up at this point is not being planned.  We are mainly a swtiched environment and the only devices that are using L3 are the core switch for WAN purposes and the lab because it is mimicking the production environment.  I have two Nexus switches that are sitting on the other side of a 3750 switch which is currently acting as a L3 device because this is a pre-production environment for a new project.  We had an issue with management of the devices before but our workaround was to put them on the management vlan direcltly off of the core, allowing only management traffic to pass by means of mgmt0 on each device.  The problem I'm having now is that I've now setup the mgmt0 interfaces on both for the keepalive link for vpc only (vpc traffic is going accross 2x10gb connections and the link to the 3750 is 1gb each trunked) and have lost my ability to use the mgmt0 connections for management. How to connect my management connection through either the 3750 or directly off the core switch (as that's what will happen once it's put into production)

View 3 Replies View Related

Cisco Switching/Routing :: Getting Nexus 5000 Command (default Interface X / X)

Jun 26, 2012

when will be the command "default interface x/x" on the Nexus 5000 platform available? Even with latest software version (5.1.3.N2.1a) it is not possible. For Nexus7000 it's working fine with 5.2 train.Is there a feature request for it? If not here it is!!It's horrible to deconfigure many interfaces especially in N5k environments with many FEXes.

View 3 Replies View Related

Cisco Switching/Routing :: Nexus 5000 And 3750 Switch Redundancy

Oct 31, 2012

My network consist of that network device. cisco catalyst 3750 with stackwise, 2xnexsus 5000  series and servers.servers connected to nexsus switch. nexsus connect to 3750.

Each server have two link, one of them connect nexsus1 and other connect to nexsus2 switch.(same traffic) each nexsus have one link to 3750. At 3750 the nexsus link configurate etherchannel. but the flapping occur at 3750.

i understand that at 2 nexsus link have the same server source mac address so the flapping occur at 3750. how i solve this problem?

View 5 Replies View Related

Cisco Switching/Routing :: Default Configuration Lines On Nexus 5000

Feb 17, 2012

What is the purpose of these default configuration lines? What do they mean? I can't find an explanation of them anywhere. I believe some are written to the config when FCoE is enabled..
 
I would like to know exactly what they are doing.
 
class-map type qos class-fcoe
class-map type queuing class-fcoe
match qos-group 1

[Code].....

View 5 Replies View Related

Cisco Switching/Routing :: Nexus 5000 / MTU Mismatch In Layer 2 Network?

Dec 26, 2012

I am just wondering on how mismatched MTU sizes are handled in Layer-2 networks and also inside a particular switches internal architecture.Layer 2 devices do not do fragmentation in the even of MTU mismatch. is this because Layer 2 devices do not re-write header information (like inserting destination IP and next hop MAC into the newly created frame.) i believe this is what they call per-hop behaviour? if this not the reason, then...? assuming this is the reason, let me proceed to my next question.     When we set MTU on an interface , there is no mention of direction (ingress or egress), so i take this as means in both directions. so if a jumbo frame comes in on an interface which is set to recieve jumbo frames and forwarding decision is made and the frame is scheduled to egress via an interface whose MTU is not set for Jumbo frames, will the switch drope the frame at the egress buffer? if not, this implies MTU is an ingress property(only for incoming packets). But, again if it drops the packet, then MTU shoud have been system wide or global configuration as opposed to interface level configuration (just like nexus 5000).

View 2 Replies View Related

Cisco Switching/Routing :: Nexus 5000 Interface - Data Transfer Low

Jun 6, 2012

Customer  production environment is nexus 5000 use 1 G interface * 4 and config Port-channel  ( LACP ) uplink to C3560 , The port channel link is 802.1q trunk , but Data transfer is low , the sh int display as follow :
 
Why transfer performance pool and how to fix
 
N-5548UP# sh int ethernet 1/30Ethernet1/30 is up  Hardware: 1000/10000 Ethernet, address: 547f.ee14.ed25 (bia 547f.ee14.ed25)  MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec,     reliability 255/255, txload 1/255, rxload 1/255  Encapsulation ARPA  Port mode is trunk  full-duplex, 1000 Mb/s, media type is 10G  Beacon is turned off  Input flow-control is off, output flow-control is off  Rate mode is dedicated  Switchport monitor is off  EtherType is 0x8100  Last link flapped 9week(s) 6day(s)  Last clearing of "show interface" counters 20w2d  30 seconds input rate 152 bits/sec, 19 bytes/sec, 0 packets/sec  30 [Code]...

View 1 Replies View Related

Cisco Switching/Routing :: 3560x High Latency Ping To Switch Itself Show 12ms

Nov 25, 2012

i have a cisco 3560x poe. ny currnet version is 12.2(58)SE2.the cpu process is aboute 30% average.my problem is- ping to the switch itself show me 12ms which is high latency.*note- data between two hosts no this has no latency.i realize the packet go into the cpu itself but, the cpu is not loadedusy. so my question is- is this natural behavior?

View 2 Replies View Related

Cisco Switching/Routing :: 3950 - High Latency And Packet Drop Towards Access Switches?

Jan 27, 2013

My network Infrastructure consists of 2 core switches(cisco 3950, 24 port) and 3 access switches (cisco 2960G, 48port). No distribution layer.Both Core switches are connected to the BVI of a VPN router.PVST is running in all switches. The STP results are all good. We have 3 VLAN's in the LAN an IP routing is enables in the core switch. The network diagram is attached.
 
The issue we are facing is that , we get intermittent packet drops while pinging towards the access switches, and there is always a higher latency towards these assess switches.These issues are present even with no other users using the LAN. But these issues are not present while pinging towards the GW.
 
I guess, it is because of this, we have issues the accessing file server in the LAN. How do we go ahead with the troubleshooting. Will upgrading the IOS resolve this.The present version details is..
 
WS-C2960G-48TC-L   12.2(44)SE6           C2960-LANBASEK9-M

View 2 Replies View Related

Cisco Switching/Routing :: 6513 CatOS Config To IOS

Jul 31, 2012

I have a new 6513 with 2 sup32's with IOS. This chassis will replace a working 6513 with 2 sup2's with CatOS.I need to pull the running config from the CatOS chassis and make it work on the IOS chassis. i can do this manually but was wondering if there are any trade secrets on doing this.

View 3 Replies View Related

Cisco Switching/Routing :: Replacing A Backup Sup 720 On 6513

Nov 21, 2011

I am replacing a faulty sup720 on a 6513. It s the backup/hot not the active sup. It has the same IOS on it. Is it correct that all I need to do is remove the faulty and replace it with  the new sup and do a wr mem? Fromwat I have read their should be no down time all connectivity should remain stable?

View 6 Replies View Related

Cisco Switching/Routing :: Unable To Console / Ssh To 6513

Aug 9, 2012

I have a 6513 with redundant sup 720-3B's that I cannot get onto.  In short, one of the power supplies failed, it still passes traffic but I can't console or ssh to the box.  Other than the two sup 720's, I have a 4 port 10gig card, a 16 port GBIC Card and an IDS module.  I have tried removing the 10Gig, IDS and one of the sup's but still don't get anything on the console.  I have rebooted the entire chassis and don't get anything on my console while booting.  I have tried changing the speed of my terminal to every setting available incase someone has changed it at some stage but to no avail. I have tried swapping sup's, using only one at a time in the chassis but not getting anything. Is there anything else I can try to get onto this chassis?  The power supply is a 3000w with a 32amp input.  The failed power supply had tripped a switch, when i brought it back up, the power supply came out but the output failed LED is on. My #questions are, is there anything else I can do to try get onto the console, and is the power supply goosed when the RED LED is lit?  I have reseated the power supply also but the same result.

View 2 Replies View Related

Cisco Switching/Routing :: 6513 / 6509 E - EOL Notices

Apr 18, 2013

Are there any EOL notices out for the Catalyst 6513, 6509 etc E chassis? I cant find anything on the internet for the E variant, so assume this hasn't had a notice published yet.

View 2 Replies View Related

Cisco Switching/Routing :: VSS Configuration On 6513 Switches

Mar 10, 2013

My question is regarding VSS configuration on Cisco  6513 switches. My understanding is that the hardware and software  configuration on the devices must be exactly the same for the VSS to  function correctly. Do the Bootstrap versions also have to be identical?
 
The production switch is running Bootstrap Version 12.2(17r)SX5, while the new switch is running Bootstrap Version 12.2(17r)SX7.

View 3 Replies View Related