Cisco Switching/Routing :: Replacing A Backup Sup 720 On 6513
Nov 21, 2011
I am replacing a faulty sup720 on a 6513. It s the backup/hot not the active sup. It has the same IOS on it. Is it correct that all I need to do is remove the faulty and replace it with the new sup and do a wr mem? Fromwat I have read their should be no down time all connectivity should remain stable?
View 6 Replies
ADVERTISEMENT
Jun 18, 2012
I have a supervisor blade, (VS-S720-10G-3C), in a 6513 that is faulty and needs replaced. Do I need to replace the IOS on the new supervisor blade to make sure it is the same as the IOS image that is on the Active supervisor module, or will it synchronize automatically?
In the synchronization process, the active supervisor engine checks the standby supervisor engine run-time image to make sure that it matches its own run-time image. The active supervisor engine checks three conditions:
#
•If it needs to copy its boot image to the standby supervisor engine
#
•If the standby supervisor engine bootstring needs to be changed
#
•If the standby supervisor engine needs to be reset
I was reading the above documentation that mentioned the active supervisor should copy the image if it detects a newly installed standby supervisor blade with a different image, is this correct or was it referring to synchronizing the configuration file?
View 3 Replies
View Related
Apr 18, 2013
I need to know the command to take the Backup and Restore of IOS Image of 6513 through tftp server.
View 6 Replies
View Related
Oct 29, 2012
we have a chassis 6513-E and a module WS-X6748-GE-TX, I'd like to know if could I put this module in any slot, since the documentation from Cisco says that any slot from a chassis 6500-E Series can support this module. And then in the documentation of WS-X6748-GE-TX says that this module is not compatible in the slots 1-8 of the 6513 chassis, only from 9th to 13th slots, in those slots from the 6513-E we already have 4x WS-X6748-GE-TX, and we'd like to know if could we put the module in the rest of the slots. The 6513, and 6513-E is kind of confusing.
View 4 Replies
View Related
Jul 27, 2012
I have the task of replicating the router config on a 3825 router on a 3750 switch. Reason is we are taking out the router and replacing it with the switch to make use of the router for other functions.
Below is main part of the router config:
!
ip source-route
ip cef
!
!
multilink bundle-name authenticated
!
license udi pid CISCO3825 sn FCZxxxxxxx
!
vlan internal allocation policy ascending
[code].....
The 3750 switch I have runs C3750E-UNIVERSALK9-M, Version 12.2(55)SE3 on a LAN BASE license.
The first thing I have done is to order for a license upgrade to IP BASE which would give the support for OSPF routing.I do not see much of an issue with the Interface configs, however, I am not too sure about replicating the routing config on the switch.
My question is can I run the commands as shown for the OSPF routing on the switch? If not, can I get suggestions on how best to set this up on the switch?
View 4 Replies
View Related
Oct 29, 2011
How to replace a defective redundant sup. I read on several articles that inserting new redundant sup should not be an issue as the active sup will always send its configuation to the standby. We are running SSO on the Sup720. Should I switch it to RPR before I install the redundant sup? I read a case wherein they switched it to RPR from SSO before inserting the new redundant sup. My concern is the IOS mismatch since Cisco doesn't always send the same IOS on RMAs.What I am planning is this.
1. Save/Backup configuration
2. Remove the redundant sup on slot 8 (since it is a 6513)
3. Insert the new redundant sup on slot 8.
4. Check if all the configurations were synced from slot 7 to slot 8.
5. Copy the IOS from sup-bootflash to slavesup-bootflash. (if the IOS are not the same)
6. Check show bootvar to see if the boot variables are correct.
7. If bootvar is the same, reload slot 8 to boot the new IOS.
Is this a good plan or am I missing something? I am worried with this document if the redundant sup has a different software. If i insert the card in slot8, according to Cisco, it will revert to RPR. If slot 8 boots and it has a different OS, then slot 7 will switch to RPR even if it's active. Would I still be able to access the slavesup-bootflash of slot 8? Is it going to boot 100%? I read that doing a force switchover will cause a flip and RPR would cause the line cards to reinitialize and I don't want that. Well I am not going to do a force switchover since i want slot7 to be active and retain slot 8 as hot.
View 3 Replies
View Related
Dec 6, 2012
We have sup engine 6L(WS-X45-SUP6L-E) on two 4506 switch. both switches connected in LAN (HSRP primary and Secondary).
We are going to replace it with Sup7LE. What is the best procedure to get this done with minimal outage?Any other important thing to be noted ? Note : We have Lincence for SUP 7LE
View 2 Replies
View Related
Apr 8, 2013
I'm due to replace a stack of 2 x 3750 switches very soon with 2 x 3750Gs. These 2 current switches are the VTP server for a small domain. I have put the config on the new switches switches and I made it a server and used the same VTP domain and password etc and got the VLAN info ported over.Now I did this a while back and noticed the switches are in transparent mode with a revision number of 0, I need to set this back to server and swap the switches out but the revision will be lower than the client switches (around rev 200), what do I need to do?
View 7 Replies
View Related
Jul 2, 2012
I decided recently to switch out our border router (1841 12.4 advsecurity) with a shiny new 1941 (15.2 SEC/K9) as the CPU upgrade was needed.The core below acts as a VPN end point to various other remote offices we have, all of which have a similar network design at each end (and all entirely managed by me). All of these are still running 1841's with 12.4 advsecurity on them as well. These are all GRE tunnels with ipsec procection on them (not crypto maps). [code]
Everything else works fine (NAT, route-maps etc), it's just these IPSEC/isakmp tunnels that are not playing ballIt's definitely not an ARP issue (all arps were cleared) and ICMP appears to work fine (ie, I can ping the remote tunnel's public IP endpoint from the core using the loopback for that tunnel as the source). I am suspecting it's something strange with the stateful firewall config, but I did try and apply ipsec and isakmp-msft to the ip inspect list, with no success.
View 1 Replies
View Related
Mar 10, 2013
In my MDF I have a 4stack of the WS-3750-48P switches. Is it possible to replace one with a C3750X48PF-S with out causing any issues? Or would it be better to just have 3 stacked and trunk this one to the core 4506. Keeping in mind I bought this one to expand the port number for one of our remote offices.. I would hate to send them the gig switch when there isn't as much usage..Besides if I can get my CFO on this switch he might authorize me to replace the rest... He is reticent to believe it makes really all that much of a difference.
View 2 Replies
View Related
May 7, 2013
I have a 2801 router that I am replacing with a 2911. I know the ports on the 2911 are Gigabits and the 2801 are Fe. I read where the IOS would not support backup and restore on each other . I am attaching a show ver on both routers. I need to know if backup and restore would work and or what other changes would need to get done.
View 1 Replies
View Related
Jul 25, 2012
We currently have an environment with a 4507 as the core switch connected to four stacks of 3750e's in the wiring closets. A pair of Nexus 5548UP's also hangs off the 4507, but at the moment more or less dedicated to a certain purpose..The 5548UP's have the L3 daughter card installed.
My question is: Can a pair of Nexus 5548UP's do a C4507's job? Would we be able to decomission the 4507 and replace with the existing 5548UP's + FEXes?
View 1 Replies
View Related
Dec 9, 2012
We are planning to implement the 6509-E with two Sup 2Ts and a few 48 ports switches. We also want to make this the router for our network and replace the 7206VRX.
View 5 Replies
View Related
Mar 20, 2012
when replacing a line card on a 6500, i gather there is no config stored on the card, its all held on the sup, so when i put in another card the config will be the same?
View 2 Replies
View Related
Jun 3, 2013
I was wondering what general steps might be taken in order to "replace two(2) 3750 (stacked) with one (1) 3750X - Server Access". General steps and what I might have to do configuration wise. I know i'm copy pasting the existing configs into the new switch, but are there any caveats?
View 5 Replies
View Related
Feb 7, 2012
I have two 3750X in a stack. Each 3750X has one 10Gb uplink to primary core1 and one 1Gb uplink to backup core2 configured in 2 etherchannel groups. The member switch has bad ports, so I need to replace it. I have spare 3750X unit. Is it possible to connect the spare unit to the stack and then move the RJ-45 cables from the member with bad ports to the new member? That way I can minimize servers downtime to just a few seconds..If that would work, then the last step would be to move the 10Gb networking module from old member to the new one, as well as the secondary PSU. Is it doable? Also according to the documentation, all I need to add new member is matching IOS version, correct?
View 1 Replies
View Related
Nov 20, 2011
I have two 3750G switches stacked together however it's not in a full ring configuration:
Stack Ring Speed : 16G
Stack Ring Configuration: Half
Stack Ring Protocol : StackWise
And as shown below it's obvious which cable is not working:
show switch neighbors
Switch # Port 1 Port 2
-------- ------ ------
1 2 None
2 None 1
It's not flapping - it's like the cable isn't there at all. I'm going to try reseating the cable in there and perhaps an all out replacement if necessary. My question - is there any threat of a reboot of the switch stack or of partitioning of the switch stack by trying to get the 2nd cable working?
View 1 Replies
View Related
Dec 18, 2012
The stackwise marketing info states that when a failed member is replaced with a new switch the replacement switch "gets the exact configuration of the old device". I would figure it takes a little more than just disconnecting and connecting a new switch in the same spot on the stack. doing this with 3750 family switches? What are the steps to prepare the stack for a new member? what steps need to be taken on the replacement switch before insertion into the stack to make sure it gets configured like the unit it was replacing?
View 5 Replies
View Related
Jan 31, 2012
Well I have been back and forth on this a while now...I have a 6513E chassis that is getting prepped for prod. I am currently testing sso functionality and I can only get it to work using the following images on both Sup Cards.
s72033-adventerprise_wan-mz.122-33.SXI5.bin
If I try any other image, smaller or bigger in size...it forces my Sup card in mod 8 to recycle " proxy request from peer ". I have tried K9 images and non K9 images. Here is an output from sh redundancy.
Redundant System Information : Available system up time = 4 minutes Switch overs system experienced = 0 Standby failures = 0 Last switchover reason = none [code]...
View 2 Replies
View Related
Jul 31, 2012
I have a new 6513 with 2 sup32's with IOS. This chassis will replace a working 6513 with 2 sup2's with CatOS.I need to pull the running config from the CatOS chassis and make it work on the IOS chassis. i can do this manually but was wondering if there are any trade secrets on doing this.
View 3 Replies
View Related
Aug 9, 2012
I have a 6513 with redundant sup 720-3B's that I cannot get onto. In short, one of the power supplies failed, it still passes traffic but I can't console or ssh to the box. Other than the two sup 720's, I have a 4 port 10gig card, a 16 port GBIC Card and an IDS module. I have tried removing the 10Gig, IDS and one of the sup's but still don't get anything on the console. I have rebooted the entire chassis and don't get anything on my console while booting. I have tried changing the speed of my terminal to every setting available incase someone has changed it at some stage but to no avail. I have tried swapping sup's, using only one at a time in the chassis but not getting anything. Is there anything else I can try to get onto this chassis? The power supply is a 3000w with a 32amp input. The failed power supply had tripped a switch, when i brought it back up, the power supply came out but the output failed LED is on. My #questions are, is there anything else I can do to try get onto the console, and is the power supply goosed when the RED LED is lit? I have reseated the power supply also but the same result.
View 2 Replies
View Related
Apr 18, 2013
Are there any EOL notices out for the Catalyst 6513, 6509 etc E chassis? I cant find anything on the internet for the E variant, so assume this hasn't had a notice published yet.
View 2 Replies
View Related
Mar 10, 2013
My question is regarding VSS configuration on Cisco 6513 switches. My understanding is that the hardware and software configuration on the devices must be exactly the same for the VSS to function correctly. Do the Bootstrap versions also have to be identical?
The production switch is running Bootstrap Version 12.2(17r)SX5, while the new switch is running Bootstrap Version 12.2(17r)SX7.
View 3 Replies
View Related
May 16, 2012
I was working on adding a Cisco 6513 to TACACS but ran into trouble. While I work on the issue offline (recreate and test another switch), I wanted to place this switch on radius temporarily.
For some reason i cant undo/delete the AAA commands in order to point to my radius server. Below was done via console: [code]
I disabled my telemetry port on the Cisco 6513 as a precaution. The IOS im using is "s72033-advipservicesk9_wan-mz.122-33.SXI5.bin".how to remove the AAA authentication statement. Hope its not intrusive cause i have a customer on the box.
View 8 Replies
View Related
Aug 24, 2012
i have a cisco Netowtk Analysis module installed on a 6513 core switch which is NAM-1, the version on the NAM is 5.1 and we need to upgrade to the latest version which is 5.1(2)
View 1 Replies
View Related
Jul 12, 2012
I have a need to capture some traffic but my core 6513's are already using the limit of 2 span sessions. I can't edit any of the sessions either because I want to source traffic from vlans and you can only do one or the other. Is using a VACL with 'switchport capture' on the destination interface an option ? E.g. I want to source traffic from vlan 10,20,30,40 and send the all to interface Gi10/10 ? Is there any caveats ? I dont need to be too granular with the ACL's but just capture all traffic in those vlans.
View 2 Replies
View Related
Apr 28, 2012
We have Communication Media Module (WS-SVC-CMM) mounted on 6513 switch. It went down twice and we brought it up by applying "power enable module".
View 4 Replies
View Related
Mar 20, 2013
Need your expert input in sorting out the below problem.I have a cisco 6513 switch which is going into SP mode after a reboot whci i have done during BCP activity in my organization.Below are the log for your reference.
Code...
View 1 Replies
View Related
May 9, 2012
i have a Cisco 6513 it is used one, i have tryed to boot it but it did not work, it alwayes go to rommon mode and i am not able to know what is the issue,
when it boot i get the below outpot from the switch.
System Bootstrap, Version 8.1(3)
Copyright (c) 1994-2004 by cisco Systems, Inc.
Testing lower main memory - data equals address
[Code].....
View 3 Replies
View Related
Jun 4, 2012
I am getting conflicting info about this, and need to get confirmations.Is the older 6513 (non E) model compatible with WS-X6407-10GE blade?The switch we're getting this for have WS-SUP720-3B, 6000W power supply, and WS-C6K-13SLT-FAN2.From what I read they are compatible if entered in slot 9-13, but I also heard that 10GE modules are not compatible with the non E chassis.
View 1 Replies
View Related
Feb 24, 2012
We have 2 6513's that are linked via 2 10 gig interfaces, using an LACP channel.I received an alert this aft stating that the far 6513 was unreachable and the port channel int PO3 had gone down, the 2 10 gig interfaces had also gone down on either side. 5 mins later PO3 had resestablished itself and has been fine since. [code]
View 4 Replies
View Related
Jul 11, 2011
We have a pair of 6513s and upgraded the IOS version to 12.2(33)SXI4a. After the upgrade we noticed VTP Pruning was disabled: [code] Is there any effect to production we need to to consider when re-enabling? (In other words, do we need to wait until a maintenance window to enable?)Also, we are using VTP v2 (and v1...) on our VTP Client 3560 access switches.
View 2 Replies
View Related
Feb 25, 2012
We have a Cisco 6513 Switch. During some parts of the day it is having large amounts of transmit discards on a certain interface because of the amount of data we are pushing. We have determined it is a link problem and not a problem with the switch. The link cannot handle the amount of packets the switch is pushing out. I was wondering if there is a way to create a buffer or a way to regulate the maximum amount of packets that can leave that interface without losing any packets?
View 5 Replies
View Related