Cisco Switching/Routing :: Catalyst 4500 - EtherChannel Terminating On Different Line

Apr 22, 2012

I have 2 x WS-X4548-GB-RJ45 Catalyst 4500 Enhanced 48-Port 10/100/1000 Base-T (RJ-45) line cards in a 4500 chassis with 2 x WS-C4507R-E E-Series Super visor engines. We would like to create a layer 3 ether channel from a access layer switch terminating on our 4500 chassis. Can we configure the ether channel from the access layer switch such that one port on the ether channel is on one line card and the other one is on the other line card?

View 2 Replies


ADVERTISEMENT

Cisco Switching/Routing :: EtherChannel - Configuring On 4500?

Feb 28, 2012

I am about to configure 4 Gig ports for EtherChannel.  I've been reading about EtherChannel and it seems easy enough to configure.  I have a host (server)which I am going to connect to these 4 - gig ports.  This is new for me and would like some feedback for those that have used EtherChannel on their layer 2 switches.  The gig ports will be an access port with VLAN XX.

View 6 Replies View Related

Cisco Switching/Routing :: 4500 Sup 6 / Not Seeing Line Cards

Feb 14, 2012

I have a Cisco 4500 Sup 6 engine and I have two 48 port fiber line cards installed. When I do a show interfaces I do not see any of the Fiber cards. This is a new out of the box 4500 and I installed the Sup 6 Line card in Slot #1, And the two 48 port Fiber cards in Slots 2 and 3. Am I missing something, is there a command or set up procidure for the line cards. I just assumed they were plug and play

View 2 Replies View Related

Cisco Switching/Routing :: Connection With L2 EtherChannel Catalyst 3560G

Apr 11, 2012

to resolve a problem with L2 etherchannel -when I add VLAN on Portchannel, this VLAN does not appear in config Members of this Po, so after reboot Portchannel does not work: "...and will be suspended (vlan mask is different)"
 
I try to simulate it on test switch in office, but problem does not appear! Both switch are Catalyst3560G with same IOS.
 
1. SW in real network segment: 
 
Model revision number           : D0
Motherboard revision number     : B0
[Code]...

View 6 Replies View Related

Cisco Switching/Routing :: Etherchannel Suspended Between Catalyst 4948 And VSS 6506E

Dec 23, 2012

I describe an issue when i need to performe an L2 or L3 Etherchannel from a Catalyst 4948 IOS Enterprise and 2 xCatalyst 6506E bandled with VSS.
 
From the VSS Side when i plug cables i see on the physicals and Etherchannel that Physical and protocole layer are up. On the 4948 side, I see that physical layer is up and protocol and Etherchannel interfaces are down.
 
On the Etherchannel port summary i see that the port state is supended.
 
On the first attempt, i have test with a L3 etherchannel on both side using no switchport with two IP addresses one at each side on etherchannel interfaces.
 
The etherchannel are bundled with LACP mode active and on the second attempt with PAGP mode ON. 
 
The same configured on VSS 6506E work fine with Catalyst 3560E.

View 3 Replies View Related

Cisco Switching/Routing :: Catalyst 3560 Vlan Trunks Over Etherchannel

Jun 20, 2012

I'm configuring two etherchannel groups (2 ports in each) on a 3560 switch.  I need to trunk multiple vlans over each channel group.
 
I created the vlan trunks and allowed vlans on each physical interface.  I notice that I can also configure the vlan trunks on the port-channel interfaces that were created. Should I configure them under those interfaces, or leave them on the physical interfaces?  Relevant config is below:
 
interface Port-channel1
!
interface Port-channel2

[Code].....

View 1 Replies View Related

Cisco Switching/Routing :: 4500-E Series Line-cards Supported On 4507R?

Mar 25, 2013

I wonder are 4500-E series line cards (i.e. WS-X4648-GB-RJ45, WS-X4748-UPOE+E and WS-X4606-X2-E) supported on 4507R chassis? Datasheet says "Classic line cards may be deployed in both classic and E-Series chassis with either classic Cisco Catalyst 4500 Series supervisor engines or with the Cisco Catalyst 4500E Series Supervisor Engine." But it says nothing about E-Series line-cards being (or not) supported on classic chassis (like 4507R).

View 3 Replies View Related

Cisco Switching/Routing :: Wake On Lan (Catalyst 4500)

Jan 8, 2012

I am trying to setup the WOL for our enterprise. We have a C4500 setup with mutliple Vlans. We are using Microsoft SCCM server to wake up workstations for security update. The workstations are on vlan190 and the Microsoft server is on vlan 441
 
Here's my config
 
the config below
 
interface Vlan190ip directed-broadcast 100 (Enables the translation of a directed broadcast to physical broadcasts)
access-list 100 remark ====== Wake-On-LAN ======no access-list 100 permit udp host 10.4.40.98 any eq 9 logaccess-list 100 remark ====== End of ACL 100 ======

[Code].....

View 2 Replies View Related

Cisco Switching/Routing :: Catalyst 4500-E With SUP 6E Supported VSS

Mar 13, 2013

Whether Cisco Catalyst 4500-E with SUP 6E  Supported vss?

View 1 Replies View Related

Cisco Switching/Routing :: QoS Catalyst 4500 7E Supervisor

Apr 15, 2012

I am trying to understand the implicit limit to the priority queue. I know you can define an explicit policer but if you don't I can't find out what the rate limit really is.

View 5 Replies View Related

Cisco Switching/Routing :: Configure HA Catalyst 4500

May 20, 2012

I have two Cisco Catalyst 4507R-E I configure HA.  Tips?I plug them in gigabits ethernet?

View 15 Replies View Related

Cisco Switching/Routing :: Catalyst 6500 Switch Support Multi-chassis EtherChannel Features?

Sep 26, 2012

I came across this Multichassis EtherChannel Features when read about information from Cisco Smart Business Architecture.After checking further, knowing that Cataly  stwitch 6500 supports this feature.provide information that beside Catalyst 6500, is there any other model of Catalyst switch can support this feature?

View 4 Replies View Related

Cisco Switching/Routing :: NetFlow On Catalyst 4500-E Series

Nov 12, 2009

If a Supervisor 6-E will support NetFlow on a Catalyst 4507R-E?If not, what are my options for NetFlow on a 4507R-E?

View 7 Replies View Related

Cisco Switching/Routing :: DHCP Failover Between Two Catalyst 4500?

Apr 18, 2012

I've two Cisco 4500 running as core switches for huge and complex network. The two 4500 are going to act as dhcp server for several subnets. The easiest solution would be to split each DHCP pool  in two, and assign the first half of the pool to one of the core switch and  the second half of the pool to the second core switch. This would be a partial solution since if one of the two fails, the second core switch would not have enough dhcp leases available for all the devices connected for each subnet.For such a reason, I'm wondering if it the 4500 switches support a stateful redundant DHCP servers, so that the two switches can synchronize their DHCP lease tables. If this feature is available, I could define the same pools for both the switches without the risk of having duplicate ip addresses within the network.

View 3 Replies View Related

Cisco Switching/Routing :: High CPU Utilization On IOS For Catalyst 4500?

Feb 6, 2013

We have a Switch Catalyst 4500, model WS-C4510R+E, with 2 Supervisors, models V-10GE, which is showing high CPU values all times.When this occures, the switch shows 95-100% for total cpu for a few hours at a time.show proccesses cpu shows process Cat4k Mgmt LoPri with an unusual cpu value of 56% The show platform heath command gave me a high reading for K2L2 Address Table R which is curently 9,45% but the last hour is around a 20% average CPU ?[URL] what the process K2L2 Address Table R means and what could be the cause of this peak?

View 3 Replies View Related

Cisco Switching/Routing :: Catalyst 4500 - Reload In Progress

Oct 13, 2009

I have a Catalyst 4500 WS-C4506 and S-X4516-10GE Supervisor running under IOS 12.2(52)SG IP BASE SSH. After having installed IOS 12,2(53)SG i wanted to schedule a reload. After entering the reload at command I get the message %Reload in Progress and nothing happens.

View 4 Replies View Related

Cisco Switching/Routing :: Catalyst 4500 Or 6500 VSS Capabilities?

Dec 10, 2012

Catalyst 4500 or 6500 VSS Capabilities?

View 6 Replies View Related

Cisco Switching/Routing :: Catalyst 4500 As Layer 2 Switch But With VRF?

Oct 16, 2012

is it possible to run a Catalyst 4500 as pure Layer 2 Switch, i.e. disabling "ip routing", but still managing the switch via Fa1, i.e. the defautl mgmtVrf vrf ?I tried the following:

!
no ip routing
!
interface FastEthernet1
ip vrf forwarding mgmtVrf
ip address 192.168.1.1 255.255.255.0
!
ip route vrf mgmtVrf 0.0.0.0 0.0.0.0 192.168.1.254
ip default-gateway 192.168.1.254
 
I was not able to reach the Switch even from the same subnet. Only after enabling ip routing I could manage the Switch. I haven't found any command to set ip default-gateway for a vrf. Any workaround to keep routing disabled, but still manageable via VRF?

View 3 Replies View Related

Cisco Switching/Routing :: Documentation Of Catalyst 4500-X For Creating VSS And MEC

Mar 14, 2013

I was reading the documentation of the Catalyst 4500-X for creating VSS and MEC (multichassis etherchannel).In the VSS specific part, it's written"Cisco Release IOS XE 3.4.0SG does not support Layer 3 MEC".

Can I still use VlanX interfaces ad route through them?In my setup I only have IP addresses assigned to vlanX interfaces (with some VRF-lite magic)[code] Does that sentence only mean that I can't have IP assigned directly to the MEC?

View 4 Replies View Related

Cisco Switching/Routing :: Firmware Versions On 4500 Catalyst Switch

Sep 19, 2012

How can I find out the firmware versions for IOS, modules and components of Cisco catalyst 4500 series switch. I can see the firmware version of IOS in show version command but how can I find it out for the modules or components of the switch.

View 4 Replies View Related

Cisco Switching/Routing :: Port Grouping On 3750 Like On Catalyst 4500?

Mar 27, 2013

On 45XX catalyst , bandwidth is allocated across six 8-port groups, providing 1 Gbps per  port group. Example  for the following line card : WS-X4448-GB-SFP

I want to know if there is the same mecanism on 3750X switches. I mean is bandwidth allocated across a group of ports like on 4500 catalyst ?

View 5 Replies View Related

Cisco Switching/Routing :: Upgrading Catalyst 4500 Power Supplies?

Sep 19, 2012

If I'm upgrading dual redundant power supplies in a Catalyst 4507 from 1000W (data) to 1400W (data), can it be done without taking the switch through a power cycle? I'm guessing no as I read that the switch will not recognize a 1400W PSU in bay 2 if there is still an original 1000W PSU in bay 1.

View 2 Replies View Related

Cisco Switching/Routing :: Upgrading Software Image On Catalyst 4500?

Dec 31, 2012

I just received a new 4510R+E switch with CAT4500e SUP7e Universal Image cat4500e-universal.spa03.01.01.sg.150-1.x01.bin software imag with License Level ipbase. We specified in the order to receive CAT4500e Universal Crypto Image with License Level ipbase. I have since requested and received the latest CAT4500e Univeral Crypto Image cat4500e-universalk9-spa.03.04.00.sg.151-2.sg.bin. Is there anything other that just installing the new image that must be done to allow me to use the Crypto Image? Would this upgrade do anything to change my License Level ipbase?

View 1 Replies View Related

Cisco Switching/Routing :: Upgrading Catalyst 4500 Series Supervisor

Jan 8, 2012

Does a new Cisco Catalyst 4500 series supervisor 7L-E model WS-X45-SUP7L-E is backward compatible with a Cisco Catalyst 4500 series chassis model 4507R? I've checked on Cisco website for that Supervisor and it shows only new chassis models WS-C4507R+E and R-E, but what about old type of chassis? We need to upgrade that Supervisor as it's out of line, but we don't really want to buy a new chassis as well as it's going to be very pricy.

View 6 Replies View Related

Cisco Switching/Routing :: Filter IP Traffic By MAC Address On Catalyst 4500?

Dec 19, 2012

We want to filter IP traffic by MAC address on Catalyst 4500. Since we are using bonding (active-backup mode) we need those mac addresses appear on different ports. Below are solutions that we have tried: ACL but it does not   work since mac acls only match non ip traffic (We CAN NOT use ip acl). Use a static mac address-table entry to ALLOW specific mac addresses. It does not work  either since the same MAC address needs to be seen on a different port. Catalyst 4500 does not support auto-learn option (as e.g. Nexus 5000). 

View 3 Replies View Related

Cisco Switching/Routing :: Catalyst 4500-E / Found BUG Between EEM And Remote Host Logging In Various IOS?

Sep 29, 2011

I found a bug in Embedded Event Manager, on Catalyst 4500-E platform with supervisor V-10GE, on various IOS releases (in particular 12.2-50-SG IP BASE w/o crypto, 12.2-54-SG1 IP BASE w/o crypto, but also other releases included latest 15.0-2-SG1 ENTERPRISE SERVICES SSH).The problem is that when you set up a EEM applet that monitors syslog pattern matching, and you also configure remote host logging *with* the option "sequence-num-session", when the match occurs, the switch reboots with message:
 
Sw (sometimes prints a number instead)
VECTOR D00
 
and in some cases performs a second reboot with message:
 
VECTOR 0
 DOUBLE FAULT
 
The reload reason message is:
 
System returned to ROM by abort at PC 0x0
 
The problem does *not* occur if remote logging has not the option "sequence-num-session". I verified this behavior on various configurations (included our production 130K long *and* factory defaults after erase startup-config).The configuration statements that cause reload are, for expample:
 
event manager applet prova
event syslog pattern %SYS-5-CONFIG_I
action 1.0 puts "configurazione modificata"
!
logging host 172.30.10.1 sequence-num-session

View 1 Replies View Related

Cisco Switching/Routing :: High CPU For Catalyst 4500 K2L2 Address Table R?

May 8, 2011

My Catalayst 4507 is reaching up to 82% CPU utilization and I noticed that K2L2 Address Table R is causing the high CPU.
 
C4507#sh processes cpu | in HiPri|LoPri|CPU utilizationCPU utilization for five seconds: 82%/1%; one minute: 86%; five minutes: 87%  54   350533923 329104616       1065 13.27% 13.84% 13.86%   0 Cat4k Mgmt HiPri  55  1771768520 274992685       6442 59.91% 64.55% 66.04%   0 Cat4k Mgmt LoPri
 C4507#sh platform health | in K2L2|%CPuK2L2 Address Table R   2.00  66.35     12      5  100  500   91  82   58  27272:55K2L2 New Static Addr   2.00   0.00     10      0  100  500    0   0    0  0:00K2L2 New Multicast A   2.00   0.00     10      5  100  500    0   0    0  0:18K2L2 Dynamic Address   2.00   0.00     10      5  100  500    0   0    0  0:16K2L2 Vlan Table Revi   2.00   0.00     12      8  100  500    0   0    0  1:22

View 2 Replies View Related

Cisco Switching/Routing :: Configuration Module Supervisor Switch Catalyst 4500

Jun 4, 2012

switch catalyst 4500 with ios cat4500e-universal.SPA.03.02.00.XO.150-2.XO.bin. I need to configure modules 3 and 4 of supervision, the problem is that I need the 4-port module 3 are active but only the first turn on both the module 3 and the first port on the module 4. [code]

View 1 Replies View Related

Cisco Switching/Routing :: Catalyst 4500 L3 Switch - Limit FTP File Transfer

Oct 31, 2012

I have the attached setup. now i would like to limit my ftp transfer to 10 mb  from a specific vlan to ftp server on the STM-4 (622) link.  what would be the best way to limit ftp traffic to 10 mb .Video_Main#sh verCisco IOS Software, IOS-XE Software, Catalyst 4500 L3 Switch Software (cat4500e-UNIVERSAL-M), Version 03.02.00.SG RELEASE SOFTWARE (fc4)Technical Support:

[URL] Copyright (c) 1986-2011 by Cisco Systems, Inc.Compiled Tue 26-Apr-11 18:09 by prod_rel_team
Image text-base: 0x100A0994, data-base: 0x13CAB728
ROM: 15.0(1r)SG1Jawa Revision 7, Snowtrooper Revision 0x0.0x116
Video_Main uptime is 15 weeks, 3 days, 23 hours, 53 minutesSystem returned to ROM by power-onSystem restarted at 16:38:21 UTC Wed Nov 23 2011Running default software
License Information for 'WS-X45-SUP7-E'    License Level: entservices   Type: Permanent    Next reboot license Level: entservices
cisco WS-C4506-E (MPC8572) processor (revision 8) with 2097152K/20480K bytes of memory.Processor board ID FOX1502GZHFMPC8572 CPU at 1.5GHz, Supervisor 7Last reset from PowerUp9 Virtual Ethernet interfaces204 Gigabit Ethernet interfaces10 Ten Gigabit Ethernet interfaces511K bytes of non-volatile configuration memory.
Configuration register is 0x2101
Video_Main#

View 6 Replies View Related

Cisco Switching/Routing :: Catalyst 4500 - Maximum Power Cable Length?

Feb 11, 2013

I am relocating UPS units and will need to buy longer power cables to extend from our 4506 and 4510 to the new location.I think I am looking at 15 to 20 feet but I am going to confirm. Is it okay to use longer cables?

View 9 Replies View Related

Cisco Switching/Routing :: Star Wars Jargon In Catalyst 4500-E Series

Jun 21, 2012

When the 4500-E series switch boots and if you issue a 'show run' there's several Star Wars themed references and their revisions. What these actually are and why they are using Star Wars terminology?
 
Here's the output:
 
Cisco IOS Software, Catalyst 4500 L3 Switch Software (cat4500e-ENTSERVICESK9-M), Version 12.2(53)SG2, RELEASE SOFTWARE (fc1)
Technical Support: [URL]
Copyright (c) 1986-2010 by Cisco Systems, Inc.
Compiled Tue 16-Mar-10 04:50 by prod_rel_team
Image text-base: 0x10000000, data-base: 0x12794974

ROM: 12.2(44r)SG5
Darkside Revision 4, Jawa Revision 18, Tatooine Revision 140, Forerunner Revision 1.78

1AR1R2-NC1 uptime is 2 years, 2 weeks, 3 days, 15 hours, 44 minutes
System returned to ROM by power-on
System restarted at 19:29:14 UTC Fri Jun 4 2010
System image file is "bootflash:cat4500e-entservicesk9-mz.122-53.SG2.bin"

View 2 Replies View Related

Cisco Switching/Routing :: Conversion Tool For Catalyst (6509) To 4500-e IOS Switch?

Aug 15, 2012

I have seen links out there for a conversion tool to convert commands on a Catalyst type switch (6509) to newer IOS type switches(4500-e) switches but they all error out on me on a 404. Any link where I can get this conversion tool?

View 1 Replies View Related

Cisco Routing :: Catalyst 6500 / 4500 - Preventative Maintenance On Catalyst Chassis Switches?

Jun 4, 2013

Are there any best practices for preventative maintenance on Catalyst Chassis switches.  Looking to build a PMI schedule for a customer.  Or is there evidence not to perform it at all.  Things like re-seating line cards, cleaning fan exhausts, etc. 

View 1 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved