Cisco Switching/Routing :: Catalyst 4500 Or 6500 VSS Capabilities?
Dec 10, 2012Catalyst 4500 or 6500 VSS Capabilities?
View 6 RepliesCatalyst 4500 or 6500 VSS Capabilities?
View 6 RepliesAre there any best practices for preventative maintenance on Catalyst Chassis switches. Looking to build a PMI schedule for a customer. Or is there evidence not to perform it at all. Things like re-seating line cards, cleaning fan exhausts, etc.
View 1 Replies View RelatedWe are preparing to install a new switching Infrastructure at one of our sites. We have decided that we want to have two separate chassis as a core. My original idea was to purchase 2 - 4500 chassis and install 10Gb and 1GB line cards in each and use STP and HSRP to load balance between the two cores.
We had also contacted a vendor for thier recommendations and they came back with 2 6500 Chassis running VSS. I reviewed what VSS was as I had never heard of it and it looks to me basically to be real close to the same thing as Stacking. I didn't really want to have stacked Cores because I would like to have the flexibility to be able to take one core out and update the software or image, reboot, and such without effecting anything on the network. I can do that with the non-VSS approach but it looks like that would be more of a problem with VSS.
My question is, how to use VSS with the 6500's? How to take one of the VSS pairs off line and not effect normal network operations?
I am trying to setup the WOL for our enterprise. We have a C4500 setup with mutliple Vlans. We are using Microsoft SCCM server to wake up workstations for security update. The workstations are on vlan190 and the Microsoft server is on vlan 441
Here's my config
the config below
interface Vlan190ip directed-broadcast 100 (Enables the translation of a directed broadcast to physical broadcasts)
access-list 100 remark ====== Wake-On-LAN ======no access-list 100 permit udp host 10.4.40.98 any eq 9 logaccess-list 100 remark ====== End of ACL 100 ======
[Code].....
Whether Cisco Catalyst 4500-E with SUP 6E Supported vss?
View 1 Replies View RelatedI am trying to understand the implicit limit to the priority queue. I know you can define an explicit policer but if you don't I can't find out what the rate limit really is.
View 5 Replies View RelatedI have two Cisco Catalyst 4507R-E I configure HA. Tips?I plug them in gigabits ethernet?
View 15 Replies View RelatedI encountered a problem migrating configuration from Cisco 4500 with IOS 12.2(53)SG4 to Cisco 6500-VSS with IOS 12.2(33)SXI7.
With 4500, we had 2 servers with JBoss running multicast to build up the cluster. They used 239.X.X.X multicast IP. There was no need to configure "ip igmp snooping vlan XX static XXXX.XXXX.XXXX interface X" neither static arp entry.
When we migrated to 6500 in VSS, we had to do:
mac-address-table static XXXX.XXXX.XXXX vlan XX interface X disable-snooping
With this command, the JBoss cluster worked well. The question is, ¿Is there any difference regarding IGMP in 4500 versus 6500?
If a Supervisor 6-E will support NetFlow on a Catalyst 4507R-E?If not, what are my options for NetFlow on a 4507R-E?
View 7 Replies View RelatedI've two Cisco 4500 running as core switches for huge and complex network. The two 4500 are going to act as dhcp server for several subnets. The easiest solution would be to split each DHCP pool in two, and assign the first half of the pool to one of the core switch and the second half of the pool to the second core switch. This would be a partial solution since if one of the two fails, the second core switch would not have enough dhcp leases available for all the devices connected for each subnet.For such a reason, I'm wondering if it the 4500 switches support a stateful redundant DHCP servers, so that the two switches can synchronize their DHCP lease tables. If this feature is available, I could define the same pools for both the switches without the risk of having duplicate ip addresses within the network.
View 3 Replies View RelatedWe have a Switch Catalyst 4500, model WS-C4510R+E, with 2 Supervisors, models V-10GE, which is showing high CPU values all times.When this occures, the switch shows 95-100% for total cpu for a few hours at a time.show proccesses cpu shows process Cat4k Mgmt LoPri with an unusual cpu value of 56% The show platform heath command gave me a high reading for K2L2 Address Table R which is curently 9,45% but the last hour is around a 20% average CPU ?[URL] what the process K2L2 Address Table R means and what could be the cause of this peak?
View 3 Replies View RelatedI have a Catalyst 4500 WS-C4506 and S-X4516-10GE Supervisor running under IOS 12.2(52)SG IP BASE SSH. After having installed IOS 12,2(53)SG i wanted to schedule a reload. After entering the reload at command I get the message %Reload in Progress and nothing happens.
View 4 Replies View Relatedis it possible to run a Catalyst 4500 as pure Layer 2 Switch, i.e. disabling "ip routing", but still managing the switch via Fa1, i.e. the defautl mgmtVrf vrf ?I tried the following:
!
no ip routing
!
interface FastEthernet1
ip vrf forwarding mgmtVrf
ip address 192.168.1.1 255.255.255.0
!
ip route vrf mgmtVrf 0.0.0.0 0.0.0.0 192.168.1.254
ip default-gateway 192.168.1.254
I was not able to reach the Switch even from the same subnet. Only after enabling ip routing I could manage the Switch. I haven't found any command to set ip default-gateway for a vrf. Any workaround to keep routing disabled, but still manageable via VRF?
I was reading the documentation of the Catalyst 4500-X for creating VSS and MEC (multichassis etherchannel).In the VSS specific part, it's written"Cisco Release IOS XE 3.4.0SG does not support Layer 3 MEC".
Can I still use VlanX interfaces ad route through them?In my setup I only have IP addresses assigned to vlanX interfaces (with some VRF-lite magic)[code] Does that sentence only mean that I can't have IP assigned directly to the MEC?
Could I connect a WS-G5484 (4500) to X2-10GB-SR (6500)?These two transceivers modules have 850 wavelenght, so it should work right?
View 2 Replies View Relatedcan I plug power supply from 4500 to 6500? more specifically we have power supply PWR-C45-1300ACV. And we need to place some power supply to 6500, which has only one active module. So 1300 should be enough for it. But we dont know if they are physically compatible, if it is possible to plug. I didnt find this power supply to be officially?
View 4 Replies View RelatedHow can I find out the firmware versions for IOS, modules and components of Cisco catalyst 4500 series switch. I can see the firmware version of IOS in show version command but how can I find it out for the modules or components of the switch.
View 4 Replies View RelatedOn 45XX catalyst , bandwidth is allocated across six 8-port groups, providing 1 Gbps per port group. Example for the following line card : WS-X4448-GB-SFP
I want to know if there is the same mecanism on 3750X switches. I mean is bandwidth allocated across a group of ports like on 4500 catalyst ?
I have 2 x WS-X4548-GB-RJ45 Catalyst 4500 Enhanced 48-Port 10/100/1000 Base-T (RJ-45) line cards in a 4500 chassis with 2 x WS-C4507R-E E-Series Super visor engines. We would like to create a layer 3 ether channel from a access layer switch terminating on our 4500 chassis. Can we configure the ether channel from the access layer switch such that one port on the ether channel is on one line card and the other one is on the other line card?
View 2 Replies View RelatedIf I'm upgrading dual redundant power supplies in a Catalyst 4507 from 1000W (data) to 1400W (data), can it be done without taking the switch through a power cycle? I'm guessing no as I read that the switch will not recognize a 1400W PSU in bay 2 if there is still an original 1000W PSU in bay 1.
View 2 Replies View RelatedI just received a new 4510R+E switch with CAT4500e SUP7e Universal Image cat4500e-universal.spa03.01.01.sg.150-1.x01.bin software imag with License Level ipbase. We specified in the order to receive CAT4500e Universal Crypto Image with License Level ipbase. I have since requested and received the latest CAT4500e Univeral Crypto Image cat4500e-universalk9-spa.03.04.00.sg.151-2.sg.bin. Is there anything other that just installing the new image that must be done to allow me to use the Crypto Image? Would this upgrade do anything to change my License Level ipbase?
View 1 Replies View RelatedDoes a new Cisco Catalyst 4500 series supervisor 7L-E model WS-X45-SUP7L-E is backward compatible with a Cisco Catalyst 4500 series chassis model 4507R? I've checked on Cisco website for that Supervisor and it shows only new chassis models WS-C4507R+E and R-E, but what about old type of chassis? We need to upgrade that Supervisor as it's out of line, but we don't really want to buy a new chassis as well as it's going to be very pricy.
View 6 Replies View RelatedWe want to filter IP traffic by MAC address on Catalyst 4500. Since we are using bonding (active-backup mode) we need those mac addresses appear on different ports. Below are solutions that we have tried: ACL but it does not work since mac acls only match non ip traffic (We CAN NOT use ip acl). Use a static mac address-table entry to ALLOW specific mac addresses. It does not work either since the same MAC address needs to be seen on a different port. Catalyst 4500 does not support auto-learn option (as e.g. Nexus 5000).
View 3 Replies View RelatedI found a bug in Embedded Event Manager, on Catalyst 4500-E platform with supervisor V-10GE, on various IOS releases (in particular 12.2-50-SG IP BASE w/o crypto, 12.2-54-SG1 IP BASE w/o crypto, but also other releases included latest 15.0-2-SG1 ENTERPRISE SERVICES SSH).The problem is that when you set up a EEM applet that monitors syslog pattern matching, and you also configure remote host logging *with* the option "sequence-num-session", when the match occurs, the switch reboots with message:
Sw (sometimes prints a number instead)
VECTOR D00
and in some cases performs a second reboot with message:
VECTOR 0
DOUBLE FAULT
The reload reason message is:
System returned to ROM by abort at PC 0x0
The problem does *not* occur if remote logging has not the option "sequence-num-session". I verified this behavior on various configurations (included our production 130K long *and* factory defaults after erase startup-config).The configuration statements that cause reload are, for expample:
event manager applet prova
event syslog pattern %SYS-5-CONFIG_I
action 1.0 puts "configurazione modificata"
!
logging host 172.30.10.1 sequence-num-session
My Catalayst 4507 is reaching up to 82% CPU utilization and I noticed that K2L2 Address Table R is causing the high CPU.
C4507#sh processes cpu | in HiPri|LoPri|CPU utilizationCPU utilization for five seconds: 82%/1%; one minute: 86%; five minutes: 87% 54 350533923 329104616 1065 13.27% 13.84% 13.86% 0 Cat4k Mgmt HiPri 55 1771768520 274992685 6442 59.91% 64.55% 66.04% 0 Cat4k Mgmt LoPri
C4507#sh platform health | in K2L2|%CPuK2L2 Address Table R 2.00 66.35 12 5 100 500 91 82 58 27272:55K2L2 New Static Addr 2.00 0.00 10 0 100 500 0 0 0 0:00K2L2 New Multicast A 2.00 0.00 10 5 100 500 0 0 0 0:18K2L2 Dynamic Address 2.00 0.00 10 5 100 500 0 0 0 0:16K2L2 Vlan Table Revi 2.00 0.00 12 8 100 500 0 0 0 1:22
switch catalyst 4500 with ios cat4500e-universal.SPA.03.02.00.XO.150-2.XO.bin. I need to configure modules 3 and 4 of supervision, the problem is that I need the 4-port module 3 are active but only the first turn on both the module 3 and the first port on the module 4. [code]
View 1 Replies View RelatedI have the attached setup. now i would like to limit my ftp transfer to 10 mb from a specific vlan to ftp server on the STM-4 (622) link. what would be the best way to limit ftp traffic to 10 mb .Video_Main#sh verCisco IOS Software, IOS-XE Software, Catalyst 4500 L3 Switch Software (cat4500e-UNIVERSAL-M), Version 03.02.00.SG RELEASE SOFTWARE (fc4)Technical Support:
[URL] Copyright (c) 1986-2011 by Cisco Systems, Inc.Compiled Tue 26-Apr-11 18:09 by prod_rel_team
Image text-base: 0x100A0994, data-base: 0x13CAB728
ROM: 15.0(1r)SG1Jawa Revision 7, Snowtrooper Revision 0x0.0x116
Video_Main uptime is 15 weeks, 3 days, 23 hours, 53 minutesSystem returned to ROM by power-onSystem restarted at 16:38:21 UTC Wed Nov 23 2011Running default software
License Information for 'WS-X45-SUP7-E' License Level: entservices Type: Permanent Next reboot license Level: entservices
cisco WS-C4506-E (MPC8572) processor (revision 8) with 2097152K/20480K bytes of memory.Processor board ID FOX1502GZHFMPC8572 CPU at 1.5GHz, Supervisor 7Last reset from PowerUp9 Virtual Ethernet interfaces204 Gigabit Ethernet interfaces10 Ten Gigabit Ethernet interfaces511K bytes of non-volatile configuration memory.
Configuration register is 0x2101
Video_Main#
I am relocating UPS units and will need to buy longer power cables to extend from our 4506 and 4510 to the new location.I think I am looking at 15 to 20 feet but I am going to confirm. Is it okay to use longer cables?
View 9 Replies View RelatedWhen the 4500-E series switch boots and if you issue a 'show run' there's several Star Wars themed references and their revisions. What these actually are and why they are using Star Wars terminology?
Here's the output:
Cisco IOS Software, Catalyst 4500 L3 Switch Software (cat4500e-ENTSERVICESK9-M), Version 12.2(53)SG2, RELEASE SOFTWARE (fc1)
Technical Support: [URL]
Copyright (c) 1986-2010 by Cisco Systems, Inc.
Compiled Tue 16-Mar-10 04:50 by prod_rel_team
Image text-base: 0x10000000, data-base: 0x12794974
ROM: 12.2(44r)SG5
Darkside Revision 4, Jawa Revision 18, Tatooine Revision 140, Forerunner Revision 1.78
1AR1R2-NC1 uptime is 2 years, 2 weeks, 3 days, 15 hours, 44 minutes
System returned to ROM by power-on
System restarted at 19:29:14 UTC Fri Jun 4 2010
System image file is "bootflash:cat4500e-entservicesk9-mz.122-53.SG2.bin"
I have seen links out there for a conversion tool to convert commands on a Catalyst type switch (6509) to newer IOS type switches(4500-e) switches but they all error out on me on a 404. Any link where I can get this conversion tool?
View 1 Replies View RelatedWhat's the difference between a Catalyst 4500 and a Catalyst 4500E series chassis? I believe it has to to do with supporting PoE+? Are the blades in both series interchangeable?
View 1 Replies View RelatedI want to enable jumbo frame con a Catalyst 4500, specifically in the WS-X4648-RJ45-E card. (running this IOS version Version 12.2(53)SG1).
For what I checked, this are the only needed commands:
vlan xxx
mtu 9000
interface port 4
mtu 9000
exit
I want to be sure that these are the only needed comands and that they won t generate any disruption.
Any step-by-step configuration guide of how to enable DAI on Cisco Catalyst 6500 Series Switches.
View 1 Replies View Related