Cisco Switching/Routing :: Star Wars Jargon In Catalyst 4500-E Series
Jun 21, 2012
When the 4500-E series switch boots and if you issue a 'show run' there's several Star Wars themed references and their revisions. What these actually are and why they are using Star Wars terminology?
Here's the output:
Cisco IOS Software, Catalyst 4500 L3 Switch Software (cat4500e-ENTSERVICESK9-M), Version 12.2(53)SG2, RELEASE SOFTWARE (fc1)
Technical Support: [URL]
Copyright (c) 1986-2010 by Cisco Systems, Inc.
Compiled Tue 16-Mar-10 04:50 by prod_rel_team
Image text-base: 0x10000000, data-base: 0x12794974
ROM: 12.2(44r)SG5
Darkside Revision 4, Jawa Revision 18, Tatooine Revision 140, Forerunner Revision 1.78
1AR1R2-NC1 uptime is 2 years, 2 weeks, 3 days, 15 hours, 44 minutes
System returned to ROM by power-on
System restarted at 19:29:14 UTC Fri Jun 4 2010
System image file is "bootflash:cat4500e-entservicesk9-mz.122-53.SG2.bin"
View 2 Replies
ADVERTISEMENT
Nov 12, 2009
If a Supervisor 6-E will support NetFlow on a Catalyst 4507R-E?If not, what are my options for NetFlow on a 4507R-E?
View 7 Replies
View Related
Jan 8, 2012
Does a new Cisco Catalyst 4500 series supervisor 7L-E model WS-X45-SUP7L-E is backward compatible with a Cisco Catalyst 4500 series chassis model 4507R? I've checked on Cisco website for that Supervisor and it shows only new chassis models WS-C4507R+E and R-E, but what about old type of chassis? We need to upgrade that Supervisor as it's out of line, but we don't really want to buy a new chassis as well as it's going to be very pricy.
View 6 Replies
View Related
Feb 6, 2013
What's the difference between a Catalyst 4500 and a Catalyst 4500E series chassis? I believe it has to to do with supporting PoE+? Are the blades in both series interchangeable?
View 1 Replies
View Related
Aug 12, 2012
I have a strange issue with 4500 E chassis loaded with SUP 7L-E which always remains in ORANGE LED status, also the uplink ports interface is down and the line protocol is down but when i execute the command sh int gig1/5 it show me the media type sfp but there is no red laser light seen in the sfp transiever,The below command is configured for the uplink gig port on the SUP engine.hw-module uplink select gigabitethernet?
View 10 Replies
View Related
Jan 8, 2012
I am trying to setup the WOL for our enterprise. We have a C4500 setup with mutliple Vlans. We are using Microsoft SCCM server to wake up workstations for security update. The workstations are on vlan190 and the Microsoft server is on vlan 441
Here's my config
the config below
interface Vlan190ip directed-broadcast 100 (Enables the translation of a directed broadcast to physical broadcasts)
access-list 100 remark ====== Wake-On-LAN ======no access-list 100 permit udp host 10.4.40.98 any eq 9 logaccess-list 100 remark ====== End of ACL 100 ======
[Code].....
View 2 Replies
View Related
Mar 13, 2013
Whether Cisco Catalyst 4500-E with SUP 6E Supported vss?
View 1 Replies
View Related
Apr 15, 2012
I am trying to understand the implicit limit to the priority queue. I know you can define an explicit policer but if you don't I can't find out what the rate limit really is.
View 5 Replies
View Related
May 20, 2012
I have two Cisco Catalyst 4507R-E I configure HA. Tips?I plug them in gigabits ethernet?
View 15 Replies
View Related
Apr 1, 2013
We are facing cold start issue on 4500 series switch. The switch is restarting automatically almost weekly twice or thrice.As per show tech. output , there is "cold start log".Please find the attached logs for your reference.After time change , auto restart happening & am not found any log for power failure also.
View 6 Replies
View Related
Jun 19, 2012
Our company will go to buy a core switch 4503. What is the difference between the Catalyst 4500 E-Series Supervisor 7L-E and the Catalyst 4500 E-Series Supervisor 7-E?
View 1 Replies
View Related
Oct 14, 2012
We have a 4500 series switch that is running around 39% cpu utilization but seems to be dragging a bit. I did a show platform health and GalChassisVp-review has a target of 3% but an actual of 17%. All other actual values were at or below target values. I then went to show platform cpu packet statistics and in the "Packets received by Packet Queue" all queue packet values at 5 sec, 1 min, 5 min and 1 hour avg were either 0 or 1 with the exception of Esmp - that averaged 351/377/317 and 313 respectively. I then checked show platform hardware acl input entries static and the entry type InputEsmpToCPU had a whopping 10121370 hit count. All other entry types were well under that number.
View 2 Replies
View Related
Dec 11, 2011
I have a design for my infrastructure and i'm thinking to choose 4 or 5, or more, 2960 series in a stack mode instead of one 4500 series?
View 6 Replies
View Related
Apr 18, 2012
I've two Cisco 4500 running as core switches for huge and complex network. The two 4500 are going to act as dhcp server for several subnets. The easiest solution would be to split each DHCP pool in two, and assign the first half of the pool to one of the core switch and the second half of the pool to the second core switch. This would be a partial solution since if one of the two fails, the second core switch would not have enough dhcp leases available for all the devices connected for each subnet.For such a reason, I'm wondering if it the 4500 switches support a stateful redundant DHCP servers, so that the two switches can synchronize their DHCP lease tables. If this feature is available, I could define the same pools for both the switches without the risk of having duplicate ip addresses within the network.
View 3 Replies
View Related
Feb 6, 2013
We have a Switch Catalyst 4500, model WS-C4510R+E, with 2 Supervisors, models V-10GE, which is showing high CPU values all times.When this occures, the switch shows 95-100% for total cpu for a few hours at a time.show proccesses cpu shows process Cat4k Mgmt LoPri with an unusual cpu value of 56% The show platform heath command gave me a high reading for K2L2 Address Table R which is curently 9,45% but the last hour is around a 20% average CPU ?[URL] what the process K2L2 Address Table R means and what could be the cause of this peak?
View 3 Replies
View Related
Oct 13, 2009
I have a Catalyst 4500 WS-C4506 and S-X4516-10GE Supervisor running under IOS 12.2(52)SG IP BASE SSH. After having installed IOS 12,2(53)SG i wanted to schedule a reload. After entering the reload at command I get the message %Reload in Progress and nothing happens.
View 4 Replies
View Related
Dec 10, 2012
Catalyst 4500 or 6500 VSS Capabilities?
View 6 Replies
View Related
Oct 16, 2012
is it possible to run a Catalyst 4500 as pure Layer 2 Switch, i.e. disabling "ip routing", but still managing the switch via Fa1, i.e. the defautl mgmtVrf vrf ?I tried the following:
!
no ip routing
!
interface FastEthernet1
ip vrf forwarding mgmtVrf
ip address 192.168.1.1 255.255.255.0
!
ip route vrf mgmtVrf 0.0.0.0 0.0.0.0 192.168.1.254
ip default-gateway 192.168.1.254
I was not able to reach the Switch even from the same subnet. Only after enabling ip routing I could manage the Switch. I haven't found any command to set ip default-gateway for a vrf. Any workaround to keep routing disabled, but still manageable via VRF?
View 3 Replies
View Related
Mar 14, 2013
I was reading the documentation of the Catalyst 4500-X for creating VSS and MEC (multichassis etherchannel).In the VSS specific part, it's written"Cisco Release IOS XE 3.4.0SG does not support Layer 3 MEC".
Can I still use VlanX interfaces ad route through them?In my setup I only have IP addresses assigned to vlanX interfaces (with some VRF-lite magic)[code] Does that sentence only mean that I can't have IP assigned directly to the MEC?
View 4 Replies
View Related
Dec 30, 2011
I'm thinking about using a 3750 stacking around 4 or 5 switches intead of using one 4500 series switch.
1-My first argument was concerning the budget (one 4500 instead of four or five 3750 in stack mode) ---- Here i think 4 or 5 stacked 3750 is cheap than one 4500
2- My second argument was about harware redundancing that i don't have with one 4500 and that i have with stack mode ----Here i have more hardware redundancing with 3750
3- The bug that we notice today in 2960 and 3750 and not in 4500
4- Simple to manage a 4500 compare to 3750 stack design
5- I was looking also for the one with best backplane ----Here i didn't have any infos concerning the best backplane between 4 or 5 stack 3750 and a 4500.
6- I'm also looking for power redundancing.
View 5 Replies
View Related
Mar 25, 2013
I wonder are 4500-E series line cards (i.e. WS-X4648-GB-RJ45, WS-X4748-UPOE+E and WS-X4606-X2-E) supported on 4507R chassis? Datasheet says "Classic line cards may be deployed in both classic and E-Series chassis with either classic Cisco Catalyst 4500 Series supervisor engines or with the Cisco Catalyst 4500E Series Supervisor Engine." But it says nothing about E-Series line-cards being (or not) supported on classic chassis (like 4507R).
View 3 Replies
View Related
Sep 19, 2012
How can I find out the firmware versions for IOS, modules and components of Cisco catalyst 4500 series switch. I can see the firmware version of IOS in show version command but how can I find it out for the modules or components of the switch.
View 4 Replies
View Related
Mar 27, 2013
On 45XX catalyst , bandwidth is allocated across six 8-port groups, providing 1 Gbps per port group. Example for the following line card : WS-X4448-GB-SFP
I want to know if there is the same mecanism on 3750X switches. I mean is bandwidth allocated across a group of ports like on 4500 catalyst ?
View 5 Replies
View Related
Apr 22, 2012
I have 2 x WS-X4548-GB-RJ45 Catalyst 4500 Enhanced 48-Port 10/100/1000 Base-T (RJ-45) line cards in a 4500 chassis with 2 x WS-C4507R-E E-Series Super visor engines. We would like to create a layer 3 ether channel from a access layer switch terminating on our 4500 chassis. Can we configure the ether channel from the access layer switch such that one port on the ether channel is on one line card and the other one is on the other line card?
View 2 Replies
View Related
Sep 19, 2012
If I'm upgrading dual redundant power supplies in a Catalyst 4507 from 1000W (data) to 1400W (data), can it be done without taking the switch through a power cycle? I'm guessing no as I read that the switch will not recognize a 1400W PSU in bay 2 if there is still an original 1000W PSU in bay 1.
View 2 Replies
View Related
Dec 31, 2012
I just received a new 4510R+E switch with CAT4500e SUP7e Universal Image cat4500e-universal.spa03.01.01.sg.150-1.x01.bin software imag with License Level ipbase. We specified in the order to receive CAT4500e Universal Crypto Image with License Level ipbase. I have since requested and received the latest CAT4500e Univeral Crypto Image cat4500e-universalk9-spa.03.04.00.sg.151-2.sg.bin. Is there anything other that just installing the new image that must be done to allow me to use the Crypto Image? Would this upgrade do anything to change my License Level ipbase?
View 1 Replies
View Related
Dec 19, 2012
We want to filter IP traffic by MAC address on Catalyst 4500. Since we are using bonding (active-backup mode) we need those mac addresses appear on different ports. Below are solutions that we have tried: ACL but it does not work since mac acls only match non ip traffic (We CAN NOT use ip acl). Use a static mac address-table entry to ALLOW specific mac addresses. It does not work either since the same MAC address needs to be seen on a different port. Catalyst 4500 does not support auto-learn option (as e.g. Nexus 5000).
View 3 Replies
View Related
Sep 29, 2011
I found a bug in Embedded Event Manager, on Catalyst 4500-E platform with supervisor V-10GE, on various IOS releases (in particular 12.2-50-SG IP BASE w/o crypto, 12.2-54-SG1 IP BASE w/o crypto, but also other releases included latest 15.0-2-SG1 ENTERPRISE SERVICES SSH).The problem is that when you set up a EEM applet that monitors syslog pattern matching, and you also configure remote host logging *with* the option "sequence-num-session", when the match occurs, the switch reboots with message:
Sw (sometimes prints a number instead)
VECTOR D00
and in some cases performs a second reboot with message:
VECTOR 0
DOUBLE FAULT
The reload reason message is:
System returned to ROM by abort at PC 0x0
The problem does *not* occur if remote logging has not the option "sequence-num-session". I verified this behavior on various configurations (included our production 130K long *and* factory defaults after erase startup-config).The configuration statements that cause reload are, for expample:
event manager applet prova
event syslog pattern %SYS-5-CONFIG_I
action 1.0 puts "configurazione modificata"
!
logging host 172.30.10.1 sequence-num-session
View 1 Replies
View Related
May 8, 2011
My Catalayst 4507 is reaching up to 82% CPU utilization and I noticed that K2L2 Address Table R is causing the high CPU.
C4507#sh processes cpu | in HiPri|LoPri|CPU utilizationCPU utilization for five seconds: 82%/1%; one minute: 86%; five minutes: 87% 54 350533923 329104616 1065 13.27% 13.84% 13.86% 0 Cat4k Mgmt HiPri 55 1771768520 274992685 6442 59.91% 64.55% 66.04% 0 Cat4k Mgmt LoPri
C4507#sh platform health | in K2L2|%CPuK2L2 Address Table R 2.00 66.35 12 5 100 500 91 82 58 27272:55K2L2 New Static Addr 2.00 0.00 10 0 100 500 0 0 0 0:00K2L2 New Multicast A 2.00 0.00 10 5 100 500 0 0 0 0:18K2L2 Dynamic Address 2.00 0.00 10 5 100 500 0 0 0 0:16K2L2 Vlan Table Revi 2.00 0.00 12 8 100 500 0 0 0 1:22
View 2 Replies
View Related
Jun 4, 2012
switch catalyst 4500 with ios cat4500e-universal.SPA.03.02.00.XO.150-2.XO.bin. I need to configure modules 3 and 4 of supervision, the problem is that I need the 4-port module 3 are active but only the first turn on both the module 3 and the first port on the module 4. [code]
View 1 Replies
View Related
Oct 31, 2012
I have the attached setup. now i would like to limit my ftp transfer to 10 mb from a specific vlan to ftp server on the STM-4 (622) link. what would be the best way to limit ftp traffic to 10 mb .Video_Main#sh verCisco IOS Software, IOS-XE Software, Catalyst 4500 L3 Switch Software (cat4500e-UNIVERSAL-M), Version 03.02.00.SG RELEASE SOFTWARE (fc4)Technical Support:
[URL] Copyright (c) 1986-2011 by Cisco Systems, Inc.Compiled Tue 26-Apr-11 18:09 by prod_rel_team
Image text-base: 0x100A0994, data-base: 0x13CAB728
ROM: 15.0(1r)SG1Jawa Revision 7, Snowtrooper Revision 0x0.0x116
Video_Main uptime is 15 weeks, 3 days, 23 hours, 53 minutesSystem returned to ROM by power-onSystem restarted at 16:38:21 UTC Wed Nov 23 2011Running default software
License Information for 'WS-X45-SUP7-E' License Level: entservices Type: Permanent Next reboot license Level: entservices
cisco WS-C4506-E (MPC8572) processor (revision 8) with 2097152K/20480K bytes of memory.Processor board ID FOX1502GZHFMPC8572 CPU at 1.5GHz, Supervisor 7Last reset from PowerUp9 Virtual Ethernet interfaces204 Gigabit Ethernet interfaces10 Ten Gigabit Ethernet interfaces511K bytes of non-volatile configuration memory.
Configuration register is 0x2101
Video_Main#
View 6 Replies
View Related
Feb 11, 2013
I am relocating UPS units and will need to buy longer power cables to extend from our 4506 and 4510 to the new location.I think I am looking at 15 to 20 feet but I am going to confirm. Is it okay to use longer cables?
View 9 Replies
View Related
Aug 15, 2012
I have seen links out there for a conversion tool to convert commands on a Catalyst type switch (6509) to newer IOS type switches(4500-e) switches but they all error out on me on a 404. Any link where I can get this conversion tool?
View 1 Replies
View Related