Dec 25, 2011I need to know if Cisco Switch 2960 support Netflow. If it doesn't, how do I configure the switch to enable Netflow?
View 3 RepliesI need to know if Cisco Switch 2960 support Netflow. If it doesn't, how do I configure the switch to enable Netflow?
View 3 RepliesI have CISCO RPS 600 (PWR-AC-RPS) is it support Catalyst 2960 and 3560 ? and which type of cable require since i have cable 22-18 pin and on my switch require 22-14 pin.
View 2 Replies View RelatedI have a customer with Cisco 7940 and 7960 IP phones that they do not plan to replace. They do want a new LAN and are looking at the Catalyst WS-C2960S-48FPD-L and WS-C2960S-24PD-L as access layer devices.
these switches support the Cisco pre-standard PoE required by the 7940 and 7960 IP phones.
If a Supervisor 6-E will support NetFlow on a Catalyst 4507R-E?If not, what are my options for NetFlow on a 4507R-E?
View 7 Replies View RelatedIt is possible to configure the IOS NetFlow 122-58.SE2 in a Catalyst 3560?
View 5 Replies View RelatedI am trying to use the following commands on the switch but it is not supported:
ip route-cache flow
ip flow-export destination
Attached is the output for show version and show module commands from the switch.
I can't seem to find any information on the Nexus 5000 support of netflow. I assume that means it doesn't do netflow.
View 5 Replies View RelatedWe are getting log messages like
%EARL-DFC4-4-NF_USAGE: Current Netflow Table Utilization is 95%
%EARL-DFC4-4-NF_USAGE: Current Netflow Table Utilization is 99%
What this messages really means and how to get rid of these messages. We are using IOS version 12.2(33)SXJ in Catalyst 6500.
I'm looking at implementing a new DMZ and wanted Netflow capability for security monitoring.The architectural principles I have to adhere to dictate that the switches within the DMZ are layer 2 however to get Netflow I need a minimum of a 3560/3750X, Network Services module, IP Base IOS with ip routing and CEF enabled.To do this and still keep the switch functioning as a layer 2 device the intention was not to configure SVI's or any static/dynamic routing protocols.Will Netflow still work in that scenario?
View 4 Replies View RelatedI know the Nexus 5548P hardware does not support Netflow.I just need to know that if we introduce the layer 3 Daughter Board N55-D160L3 does this add Netflow support?
View 3 Replies View RelatedI've been researching the 3750-x Netflow support but I'm not 100% sure of how much support it has. From what I've read the only way to get NetFlow support is to install a specific module that provides NetFlow. I also heard about how it might support s-flow but I haven't found out for sure.
View 8 Replies View RelatedI'm having trouble setting up SSH on my new Switch.
no aaa new-model
aaa authentication login default local
ip domain-name king.local
[Code].....
I would like to be able to use Vlan 10 192.168.155.1 for SSH remote management.
I have Catalyst 2960 S (WS-C2960S-48FPS-L) Switch. I have plugged in SFP module but still interface is down and line protocol down. Is there any configuration to enable SFP module and make the interface up?
This port is connected to nexus 5 k.
i try to implement layer 2 qos in 2960. when i complete to configure the switch, i want to test the qos.PC1 conect to switch port 1,PC2 conect to switch port 2 . PC1 is source teminal. i use skydata.exe and FTP for the test.
when use the skydata ,the PC2 speed can reach 10mbps.when use the FTP , the PC2 only can reach 1.2mbps. why?
I can use Putty to SSH into my new switch (Directly connected to my laptop with ethernet cable), but I cant log into my switch.
Sent username "admin"
admin@192.168.251.1's password:
Access denied
It doesnt like my password, but I have only set 1 password (king) on this switch. I've configured 3 other switches with SSH and had no problem. Been trouble shooting for awhile and It'd be great if I could have a 2nd set of eyes take a peek, Also, my running config is attached.
How would I go about stacking 4 Cisco Catalyst 2960-48PST-L switches? The one switch needs to accept a fiber connection from a distribution switch. Do I have to buy flexstack module and cables? If so where does the module go on the switch? If this switch cannot do this set up, any other switch I should look at.
View 6 Replies View RelatedWill catalyst2960 supports SSH, and how to configures with CLI.
View 2 Replies View RelatedI need to upgrade a Catalyst IOS, but I got a bit confused. The catalyst is currently running "c2960-lanbase-mz.122-35.SE5.bin", but I want to upgrade to "c2960-lanbasek9-mz.122-35.SE5.bin", in order to enable ssh. [code] What are the appropriate steps in order to upgrade to "c2960-lanbasek9-mz. 122- 35. SE5.bin". I have downloaded the tar file (c2960-lanbasek9-tar.122-35.SE5.tar)
1) Do I have to delete the old directory (drwx 192 Mar 1 1993 02:07:21 +02:00 c2960-lanbase-mz.122-35.SE5)?
2) Are these the correct steps to download and extract the IOS?
3) Where will the tar files be extracted? Will an new directory be made or do I have to make one manually?
I have packet loss with QoS configured and I was wondering is it somehow connected with the QoS configured on the switch.The traffic is passing through fa0/19 and gi0/1 interfaces.
mls qos map cos-dscp 0 8 16 24 32 46 48 56
mls qos srr-queue input bandwidth 90 10
mls qos srr-queue input threshold 1 8 16
mls qos srr-queue input threshold 2 34 66
[code]...
I have 4 Catalyst 2960 connected via Etherchannel to each other. If I plug in my notebook in one port, I see the traffic from the neighbor port. So my switch acts like a hub.. I had a look at my MAC table and saw it isn't full.
View 2 Replies View RelatedI have ciscl catlyst 2960 8port switch, (flash:c2960-lanbasek9-mz.122-50.SE4/c2960-lanbasek9-mz.122-50.SE4.bin).
and in need to configure bandwidth limit for one of the port as a 1Mbps.
In an attempt to restore a Cisco IOS I deleted the file C2960-lanbasek9-mz.122-53.SE2.bin my swich
Before deleting the same was as follows:Directory of flash :/
3-rwx 12824 Mar 28 1993 21:00:37 -03:00 vlan.dat4-rwx 3096 Mar 7 2012 08:43:37 -02:00 multiple-fs5-rwx 2289 Mar 7 2012 08:43:37 -02:00 private-config.text6-rwx 7482 Mar 7 2012 08:43:37 -02:00 config.text9 drwx 192 Mar 23 2012 16:18:54 -03:00 C2960-lanbasek9-mz.122-53.SE2
32514048 bytes total (20204544 bytes free)Switch-01 #
Right now this switch as follows:
switch: dir flash:Directory of flash:/
2 drwx 64 <date> crashinfo_ext 3 -rwx 4120 <date> multiple-fs 5 -rwx 12824 <date> vlan.dat 6 -rwx 4018 <date>
[Code].....
I have a Catalyst 2960-S switch and a pre-standard IP Phone (Cisco 7960). When I connect the phone to the switch the switch recognizes the phone and supplies power. I would like to prevent this behaviour. ie. I would like to disable detection of pre-standard equipment. Is there a command I can issue on the 2960-S to do this? For example, on a switch from a different vendor I can issue the command: no power pre-std-detect to prevent it from detecting the 7960 phone, is there an equivalent command on the Catalyst 2960-S ?
View 3 Replies View RelatedI'm trying to create trunkports on our Catalyst 2960. I'm following this guide to configure interface fa0/1
View 4 Replies View RelatedI have two 2960's in this new environment that I am administering. I am receiving a message on one unit (Designate it 2960-2) of %IP-4-DUPADDR: Duplicate address 192.168.168.8 on Vlan1, sourced by 3037.a63e.540. The "sourced by" address is the 2960-1. I do not know how these units were originally set up. How can I determine where the duplicate address is originating from.When I perform an ARP -a the address that corresponds to the 192.168.168.8 is the mac address of the ethersvi interface on the 2960-1. I
View 3 Replies View Related I followed the 3-switch Redundant stacking diagram and now when I boot up the stack Switch 2 is acutally Member 3 and Switch 3 is Member 2.
We plan on having Port-Channels spanning across Switch 1 - Master and Switch 2 (Member 3) of identical port types. Switch 3 (Member 2) is going to have 2 10GIG port channel created.
Is there going to be a problem renumbering the stack as they physically sit or should I just configure the devices based on thier logical member numbers.
I don't understand why the stack connection is Switch 1 - 1 ----> Switch 2 -1
Switch 2 - 2 ----> Switch 3- 1
Switch 3 - 2 ----> Switch 1 - 2
At one of my sites, I have a 100mbit TLS. For this connection to work properly, the port on my end needs to be setup for 100mbit, full duplex. When I connect the TLS to an interface on my Cisco 2821, configured at 100/full, it works perfectly. Now the confusing part, I'm trying to connect the TLS to a Catalyst 2960. I configure the necessary port for 100/full, and get 'notconnect' on that interface. I set the interface to auto/auto, and it negotiates at 100/half and causes collisions and packet loss.
View 9 Replies View RelatedDoes the Catalyst 3560 support GRE ?
I know that Catalyst 3750X support GRE ,but Catalyst 3750X cannot work in hardware it.
Does the Catalyst 3560 cannot work in hardware too?
Does Catalyst 3550 switch support inter vlan routing ?
View 12 Replies View RelatedIn a switch catalyst 2960 the IOS is erasing in flash, for the transfer IOs respalding to flash no function the current command. how is the method.
View 6 Replies View RelatedI have a new catalyst 2960,and i want to enable DHCP SNOOPING,but,it doesn't work,the server is stilling offert addresses IP and it's not connected in a trusted port,the schema is very simple:1 switch catalyst 2960 PST-S,1 server dhcp and 1 pc client,the PC and the server are in VLAN 10,DHCP SNOOPING is enabled in all ports and no port is trusted,but the client get addresse IP after retyping ipconfig /release and ipconfig /renew in dos commande.the configuration and the version of the switch are in the file attached.I tested the same configuration in a catalyst C3560-24PS and DHCP SNOOPING work normally,i tested in other catalyst 2960-PST-S,but the same probléme:DHCP SNOOPING without effect,the commands typed is:
-ip dhcp snnoping
-ip dhcp snooping vlan 10
we have currently a configuration with 3 bonded (link aggregation) channels, each delivering 1 Gb/s uplink, providing a total of 3 Gb/s uplink. Due to a recent network upgrade, we can now add more channels to the same group in order to have a total of 9 Gb/s uplink, meaning that we should bond toegether 9 channels. When we tried to change the old configuration in order to include six new channels to the bondend group we noticed 2 things: one channel was left in standby (blinking orange led),no increase in the uplink bandwidth semmed to happen,By looking around it looks like the channel group is limited to a maximum of 8 channels [*].
View 2 Replies View RelatedAny one who knows where I can find a documentation where it says the maximum switches per stack for the Catalyst 2960 family?
View 2 Replies View Related