Cisco Switching/Routing :: Nexus 5548UP / Two Management Interfaces For N5k
Jan 10, 2013
I have a Nexus 5548UP that would be managed by two organizations. Is it possible to set IP addresses for mgmt0 and an SVI (or an L3 interface) without using the L3 daughter card? I don't want to route between VLANs, just to separate management traffic.
View 4 Replies
ADVERTISEMENT
Apr 21, 2013
How separate is the management interface on a Nexus 5548?
In context - what's the risk of having a layer 2 only Nx5K in a DMZ and running the managment ports down into an internal managment VLAN, to form peer-keepalive links and software upgrades.
View 4 Replies
View Related
Jan 26, 2012
I have followed every piece of cisco documentation I could find on this and I still can't get vPC configured to actually work. The VLANs stay in a suspended state so no traffic flows across. Below is my configuration:vrf context management ip route 0.0.0.0/0 10.86.0.1vlan 1,vlan 86 name I.S_Infrastructure,vpc domain 1 role priority 1000 peer-keepalive destination 10.86.0.4,interface Vlan1,interface Vlan86 no shutdown description I.S._Infrastructure ip address 10.86.0.1/24,interface port-channel1 switchport mode trunk vpc peer-link spanning-tree port type normal,interface Ethernet1/1 switchport mode trunk channel-group 1 mode active,interface Ethernet1/2 switchport mode trunk channel-group 1 mode active ,interface Ethernet1/3,escription Connection to Mgmt0 switchport access vlan 86 speed 1000.
View 8 Replies
View Related
Aug 6, 2012
is it possible to change the airflow of the Nexus 5548UP in the field by replacing fan and power supply or must the correct airflow been ordered.
View 9 Replies
View Related
Aug 28, 2012
I'm trying to get a node in SVI1 on VRF1 to speak to another node in SVI2 on VRF2 to reach each other. After hours of failure, I went to outside resources. Everything I read on the internet says it's not possible on this platform and at least one TAC engineer seems to agree.
I just can't believe such a high-end data center switch is not capable of handling such a basic feature.
View 1 Replies
View Related
Jul 25, 2012
We currently have an environment with a 4507 as the core switch connected to four stacks of 3750e's in the wiring closets. A pair of Nexus 5548UP's also hangs off the 4507, but at the moment more or less dedicated to a certain purpose..The 5548UP's have the L3 daughter card installed.
My question is: Can a pair of Nexus 5548UP's do a C4507's job? Would we be able to decomission the 4507 and replace with the existing 5548UP's + FEXes?
View 1 Replies
View Related
Apr 9, 2013
I can't find anywhere whether it is possible to create a vPC domain with 2 Nexus 5548UP switches, where only 1 Nexus 5548UP has a L3 daughter card.
View 3 Replies
View Related
Aug 10, 2012
This past networkers I was at the Cisco booth discussing how the 2248 can connect to the 5548 and have server connectivity. It was told to me that now, as of a fairly recent NX-OS release, you can have the 2248 going dual-homed to both 5548 via VPC and then have a server connected to both 2248 and be in active-active mode. Is this correct?
When we first deployed our 5548 and 2248 we had to put the 2248 in a straight pin mode, where it only had connections to one 5548 and then the server would dual connect to the 2248's and be in active-active mode. I was told that this changed with an NX-OS release however documentation still seems to be fragmented on what exactly is the case.
View 3 Replies
View Related
Nov 14, 2011
it's possible to let the Nexus 5548UP act as a DHCP server? (or if it will be possible in future releases)
View 3 Replies
View Related
Dec 6, 2012
I am looking to implement a QoS policy on a pair of Nexus 5548 UPs. FCoE is a factor here. I have created the following configuration and would like to get a few pairs of eyes to take a look at this for a quick sanity check.
How to make sure this config is valid. Also, I realize I'm applying an MTU of 9216 to all classes right now, this will be phased out incrementally.
class-map type qos match-all class-platinum
match cos 5
class-map type qos match-all class-gold
match cos 4
class-map type qos class-fcoe
match cos 3
[code]....
View 1 Replies
View Related
Mar 5, 2013
I have 2 sites located approximately 30 kilometers apart. I will call them site 1 and site 2.The sites are connected by a Layer 2 1GB fibre connection.I would like to add 2 X Cisco nexus 5548UP switches at site 1 and connect these 2 X Cisco nexus 5548UP switches via GLBP
I would then like to add 2 X Cisco nexus 5548UP switches at site 2 and connect these 2 X Cisco nexus 5548UP switches via GLBP.I would then like to connect the 2 X Cisco nexus 5548UP switches at site 1 and the 2 X Cisco nexus 5548UP switches at site 2 via GLBP.
View 3 Replies
View Related
Aug 28, 2012
I just received a Nexus 5548 to configure as the core of the Datacenter LAN. Is it true that the VRFs created cannot talk to each other??? I can't seem to find any documentation on how to do this and at least one TAC engineer half-heartedly believes it's not possible, either.
Basically, I'm trying to get an SVI in VRF1 to be able to talk to an device on another SVI in VRF2.
I can't believe this high-end switch, that is so capable in every regard, cannot handle this feature.
View 1 Replies
View Related
Mar 10, 2013
The best option for load balancing between 2 X Cisco nexus 5548UP switches located at one site and connecting to 2 X Cisco nexus 5548UP switches located at another site.
The sites are connected via a 1GB fibre connection. I am unable to use GLBP until GLBP is supported in further software releases.
View 1 Replies
View Related
May 1, 2012
I'm seeing several error messages like these in the logs of my Nexus 5548UP switches.
2012 Apr 24 16:39:41.470 SSV_5K_SW2 %LLDP-5-SERVER_ADDED: Server with Chassis ID aaaa.bbbb.cccc Port ID mgmt0 management address X.X.X.X discovered on local port mgmt0 in vlan 0 with enabled capability Bridge
2012 May 2 05:05:00.627 COR_CCO-NX-5548-UP_01 %LLDP-5-SERVER_REMOVED: Server with Chassis ID aaaa.bbbb.cccd Port ID aaaa.bbbb.cccc on local port Eth1/1 has been removed
2012 May 2 05:06:40.328 COR_CCO-NX-5548-UP_01 %LLDP-5-SERVER_ADDED: Server with Chassis ID aaaa.bbbb.cccd Port ID aaaa/bbbb.cccc management address NIL discovered on local port Eth1/1 in vlan 0 with enabled capability None
I will say that these 5548s are serving as the distribution layer for a UCS chassis (2x 6120 FIs) but didn't know what kind of visibility the Nexus would have into that - the chassis keyword is what's alluding to this in my mind, and I'm seeing these messages whenever interfaces that connect downstream to the fabric interconnects are brought up or down.
View 2 Replies
View Related
Aug 15, 2012
In the existing network we have Cisco 2811 router connected to Corporate MPLS cloud. Cisco 2811 is connected to Catalyst 6509 switch(set based IOS with MSFC card). Along with that we have two Catalyst 5509. We are upgrading the access layer by replacing catalyst switches with Nexus 5548 & 2248.
For a purpose of testing I have connected 5548 & 2248. Created cPC and ether channels between two. SVI and HSRP configuredon 5548. I am terminating 2651 (test router) on 2248 port 101/1/1. On 5548 I have enabled EIGRP on vlans. I am unable to ping to 2651 from nexus switch 5548 and vice-versa. I can see both devices on CDP but I do not see eigrp neighborship formed.
What configuration should go in 2248 and 2651 in order to establish a connection between two? If test is successful then I will connect 2811 to 2248 during actual migration. I assume that in testing if it works for 2651 then it must work on 2811 router.
View 67 Replies
View Related
Apr 19, 2013
I have a pair of Nexus 5548UPs that have some high priority servers running on them. Servers are ESX hosts running Nexus 1000v's. Each host has multple connections in a VPC to both 5548s. We have been having intermittant ping loss and slowness of traffic to the VM's on these hosts. I was poking around trying to figure out what the issue could be and found that the peer-keepalive command was not set to send the heart beat across the mgmt0 interface. I would like to change this to point it accross the mgmt0 interface. Any tips or advice for me on making this change with production servers running on the switches? I do not want to cause any loss to any systems when I make this change. [Code] ..........
View 3 Replies
View Related
Dec 9, 2012
We have recently upgraded oor LAN and we are using couple of Nexus5548UP switches in the core with 2960 stacks as access switches. Each access switches stack is connnected to both core switches with link being port-chanels and VPCs. All is working fine, but our SolarWinds management platform (NPM) is being flooded with "Physical Address changed" events. Here is an example of messages:
NSW_Core_2 - Ethernet1/7 Physical Address changed from 000000003811 to 73616D653811
NSW_Core_2 - Ethernet1/7 Physical Address changed from 200B82B43811 to 000000003811
For each interface I have messages like these repeating.I am not sure what those messages means or if there is actually anything wrong. Performance of the network is good, there are no errors on any interfaces and I do not see anything related in the switch loggs.
View 4 Replies
View Related
Oct 11, 2012
Need clarification on the VPC with 5k and 2248 Fabric Extenders. My question is can each fabric extender uplink to two different 5ks, and at the same time, have servers connected to two both fabric extenders with a VPC.So basically, the server NIC will team with two different fabric extenders, and each fabric extender will connect to two different 5k's.
View 3 Replies
View Related
Sep 17, 2012
We are currently using two Nexus 5548UP's as our Datacenter Network Core. I have a pretty simple objective: I would like to enable Jumbo Frames on a single VLAN only(VLAN 65). This VLAN is used strictly for backups. I do not want to enable Jumbo Frames on the other VLANs(VLANs 1-10). Im not sure what the best way to do this is.....or if it is even possible but I am hoping to get some configuration examples.
View 7 Replies
View Related
Jun 4, 2012
I use Nexus 7010 as our layer 3 router.I have ssh feature turned on so I can manage it from the management interface. I just found out that users can use putty to ssh to the local SVI interface of the NEXUS. Although they still need username and password to login but we dont want them even able to bring up the welcome screen.Example, user's IP is : 172.16.25.100 , they can ssh to 172.16.25.1 which is the NX SVI interface.
View 1 Replies
View Related
Jun 21, 2012
We are trying to connect 2 nexus 5558UP (5.1.(3)N1(1)) with 10G-SFP+-LR interfaces. The interfaces are not genuine cisco's (smartoptics) but as far as we can tell, they are accepted by the hardware. If we take a look at the optical levels, we can see that the switches can see eachother (double-checked by bringing down one interface to see if optical levels really disappears) on optical level, well within limits. I found a notice about changing debounce timers but this doesn't work, setting it to 0 or 1000 doesn't make a difference. Copies of the different show int commands can be found at the end of this text.
Wim Holemans
Network Services
University of Antwerp
swnxds01-enable# sh int eth1/3 transc details
Ethernet1/3(code)
View 4 Replies
View Related
Dec 8, 2012
regarding to the out of band Management interface , if I configured an intervace vlan to be as a managment interface for one vdc ( the default vdc ), when I connected to this vdc via telnet , can I switch to any other vdc ? ( suppose that I have the Admin role which allows me to enter and config all the vdc's )If that is possible so that I dont have to make a dedicated managment ip for each VDC I need to do that only if I want to make vdc admin's account to allow some users to access specific vlans only , is that true ?
View 2 Replies
View Related
Aug 15, 2012
I want to configure management for some Nexus 5548's?I wanted to manage the switches via an SVI. I have read the following document which gives details about the Management SVI but doesn't answer all questions.[URL]I am not running any layer 3 functionality on the switch, no layer3 license (which it mentions in the above link) Will I still be able to create a management SVI. I know I will need to enable the feature 'interface-vlan' to setup a Management SVI, does that require a license?
View 6 Replies
View Related
Apr 16, 2013
i have: two nexus 5596 connected each other the mgmt0 is NOT in use SVI for keepalives with IP address and /30 netmask vpc-keepalives running over fiber in e1/1. this works well uplinks to datacenter distribution switch (Cat 6500 VSS) over fiber on port-channel 1 (e1/2 and e1/10), also carrying the management VLAN (vlan 14). SVI with an IP address for management purposes
I can't get this to work. i can ping my whole network from the nexus, but not the nexus from my network. also pinging inside the mgmt vlan is not possible.
View 7 Replies
View Related
Apr 28, 2013
We have a couple of Nexus 7010's split into Core and Distribution VDCs. MGMT0 interfaces on each of the Nexus VDC's (including the Admin VDC) are configured with different IP address, but on the same subnet i.e 10.10.10.1/24 for admin, 10.10.10.2/24 for Core and 10.10.10.3/24 for Distribution. The MGMT 0 physical port on each Nexus is connected to a physical gig port on a 3750 X switch, and the 3750X has uplinks back to the Nexus configured for vPC.
When i ssh to the VDC MGMT0 IPs from the 3750X, i can access each of these VDCs without any problems. But if i enable routing on each of these links(OSPF) and advertise it to the WAN, i cannot see these routes advertised and also cannot see any of these routes in the local routing table.Just wondering if i have to enable these links on a VLAN and then advertise it to the WAN..But if this the case, VLANs cannot be created on the Admin(default VDC).
View 9 Replies
View Related
Apr 26, 2012
Trying to get the peer links to work and have them in interfaces E1/1-4 . When i do a show int status it looks like this and says sfp invalid. I see this on both sides. These same model gbics work fine attached to a FEX on these boxes.
Eth1/1 vpc peer link to T sfpInvali trunk full 10G Fabric Exte
Eth1/2 vpc peer link to T sfpInvali trunk full 10G Fabric Exte
Eth1/3 vpc peer link to T sfpInvali trunk full 10G Fabric Exte
Eth1/4 vpc peer link to T sfpInvali trunk full 10G Fabric Exte
Gbic in ports are this.
Ethernet1/1-4
transceiver is present
type is Fabric Extender Transceiver
name is CISCO-FINISAR
part number is FTLX8570D3BCL-C1
[code]....
View 5 Replies
View Related
Feb 12, 2012
we do not have an out-of-band management network and setting one up at this point is not being planned. We are mainly a swtiched environment and the only devices that are using L3 are the core switch for WAN purposes and the lab because it is mimicking the production environment. I have two Nexus switches that are sitting on the other side of a 3750 switch which is currently acting as a L3 device because this is a pre-production environment for a new project. We had an issue with management of the devices before but our workaround was to put them on the management vlan direcltly off of the core, allowing only management traffic to pass by means of mgmt0 on each device. The problem I'm having now is that I've now setup the mgmt0 interfaces on both for the keepalive link for vpc only (vpc traffic is going accross 2x10gb connections and the link to the 3750 is 1gb each trunked) and have lost my ability to use the mgmt0 connections for management. How to connect my management connection through either the 3750 or directly off the core switch (as that's what will happen once it's put into production)
View 3 Replies
View Related
Jun 4, 2012
Got an odd problem with trunking, all vlans except vlan1 trunk perfectly. Link is from a pair of dualhomed FEX 2248TP's to some 3650G Switches. Nexus running - version 5.1(3)N2(1) 3560's running - 12.2(53)SE2 & 15.0(1)SE2
View 3 Replies
View Related
May 23, 2013
We have a Nx5548up pair connected to FI6248 via a vPC. We had to reboot a FI (in order to configure more FC ports) ; following that reboot, we meet many issues.The first log shows the vPC down showing the FI rebbot.2013 May 23 12:31:45 sw-n5kup-fr-eqx-01 %ETH_PORT_CHANNEL-5 PORT_INDIVIDUAL_DOWN: individual port Ethernet1/2 is down
View 1 Replies
View Related
Feb 23, 2011
We are facing issue of continous packet discards On nexus4001L link (int po2) to Nexus5020 switch. Nexus4001L is installed in IBM blade center server and we have FCOE enabled in this setup. [code]
View 2 Replies
View Related
Mar 15, 2013
I have been tasked to replace the existing Cat 6500 and 3750 switches by Nexus 7000 and Nexus 2000.I was told initially my boss plans to get 2 x Nexus 7000 and then eventually blow up to 4 x Nexus 7000s.For Nexus, is there a list of tasks / points that i need to consider for building the initial design?
Can i just link the Nexus 7000 like the following?
N7k-A ========= N7k-B
| |
lots of N2ks lots of N2ks
View 12 Replies
View Related
Dec 22, 2011
Struggle to find the SNMP MIBS of the Nexus 5000 FEX tranceivers.
View 3 Replies
View Related
Nov 13, 2012
we are planning a Nexus datacenter project with this layout:Our experiences with Nexus switches are not so large until now and the manuals are very extensive.Both N5K´s should be connected directly with all 4 N2K switches. I did not find a layout like this in the manuals. Only a design,where only 2 N2K are connected to one N5K, with this fex config:Now I´m not sure if it is right to make a config like this with the same slots and fex´s or with different slots and fex´s.
View 1 Replies
View Related