We have 3 SG500-52 switches that are stacked and configured for layer 3 that replaced a couple of SG2010 switches a month ago. Switch units 1 and 2 are for servers and unit 3 for the workstations. The switches are connected with stacking SFP+ copper cables, 1 1M and 2 7M cables. The problems are occurring between the workstations and servers resulting in slow traffic on some links and connection failures. A repeatable failure occurs doing a backup from a PC on unit 3 to a server on unit 1 and 2 (2 port LAG). Moving the workstation to a port on unit 1 results in successful backups every time.
Initially I was able to confirm packet loss between my PC (on unit 3) and the servers using ping (ping -f -c 100000 -s 1460) of about .1%. The iperf program in udp mode also showed some packet loss and in tcp mode showed slow connections. A week ago I then upgraded the switches from v1.2.0.97 to v1.2.7.76 and rebooted. After that the ping and iperf tests show no problems although there are still slow connections to samba shares and the backups still consistently fail.
I suspect there is a problem with the stacking connections and have searched for traffic statistics on the stacking ports to look for errors but have not found anything. Doing a snmpwalk didn't reveal anything that I recognized. There are interface counters for all the ports except the stacking ports.
Am looking into using stacking and NIC teaming to create redunancy for user access to servers. What I am thinking is getting 2 SG500-28 switchs and configuring them in a stack that appears as one logical switch. Now on the servers I would configure 2 NICs to be a team so they appear as 1 logical interface, perferably in an active/active configuration using LACP. In this NIC team take 1 team member to switch A and the other to switch B, so each team member is on seperate switches.
Givent the scenario:
1) Will that work with the 500 series switchs? Reason for the switches is their price point is perfect for my client.
2) Besides the stack link will there also need to be a LAG between the switches or does the stack link do data traffic also?
We've have a 2 SGE2010-48 port, stacked. 4 LAGS are denifed, two on primary, whitch are working, two on slave unit are NOT working. Devices connected to LAGS are de the same and same configuration (Cisco ASA 5510).
I have a 4 member stack of 3750's. We would like to take advantage of wccp and we understand that we will need to upgrade our switch licensing from IPBase to IPServices. My question is do we need to pay for a license for each member in the stack or does one IPServices license upgrade cover the whole stack?
I am about to buy 2x Series 500 switches but before that I have a design to be sure :I want to create a redondant network so it is the reason why I want to stack 2x Series 500 switches.Each server on my network (ESX and Windows 2008) are connected with two NIC (one port on the first switch , one port on the second switch), with trunk mode + etherchannel for LACP.
First question : I saw that the limitation is up to 8 etherchanel groups, can I have a mix of multiple servers on the same etherchannel group or should I create one etherchanel group for one server with only the two NIC inside?
Second question:I want to use the series 500 to do intervlan routing and want to be sure that if the the ports are in trunk mode with some vlan set on the card itself that the default gateway for the vlan will be propagated on the two switches (in stack mode) and will not cause any issues when both switchs works fine and if one switch crashes?
How many Switches can be stacked with WS-C2960S-48FPD-L at a max..
As per my Knowledge it is 4 and as below..
Switch 1 to Switch 2 Switch 2 to Switch 3 Switch 3 to Switch 4 Switch 4 to Switch 1
If yes then, is it mandatory to do the "Switch 4 to Switch 1" stack. why am I asking this is because this stack requires a long cable and the cable which comes with the Switch is only 0.5M.
My company is beginning to have a lot of sites were we are stacking 3 to 4 C2960S-48 switche.This is making "show running-config" very very long because of the 4 x 48 interfaces.I can’t find a CLI command that show me the running-config of a ranges of interfaces. If I for example would like to see running-config for switch 3 (interfaces 3/0/1-52)The Show Running-config will show all the interfaces (for the two first swtiche = 104 interfaces), which take a time before I reach to switch 3.I miss a CLI command like: show Running-config switch 3, or module 3, or show running-config interface range x/x/x-x ?I’m well aware of the CLI command show running-config interface x/x/x, but this will only show me one interface.
We have been set the task of securing a small managed office system which is currently set up with a standard switch allowing each of the offices (containing different companies) to see each other, and in some cases, access each others documents across the network.
Obviously this is a far from adequate set up and our aim is to isolate each office using VLAN's but share a common internet connection provided by the managed offices. We have two Cisco SGE2000-G5 layer 3 switches but we are new to Cisco equipment and VLAN's so we are not quite sure on how to implement this. DHCP would need to be provided by a Router, there is no Server. We are open to suggestions on the Router as we have yet to purchase one.
I have two 3750x stacked switches , both with the latest firmware on them. I enter the configuration onto one switch and it obviously copies over onto the other switch. Although in the configuration I have both a console username and password and an enable password, when I try to log onto the initial switch that I entered the configuration on, I am prompted for a username and password, which works fine, but when I try to enter enable mode i get an error stating that no password has been set. However when logging onto the other switch I am not prompted for a username or password but when I try to enter enable mode I am prompted for a password and can access it with no problems.
how can i view the port G27 and G28 in GUI? As based on the GUI Adminstrator - > Port Management - > Port Setting i only can view from port G1 to G26. Or it will only appear when the port is active for stacking.
I have 3 x SG500-52P switches stacked. Vlan 1 is data and Vlan 3 is voice Port to Vlan membership is 1UP and 3T Port security is disabled
The issue I have is that I can have either a phone or a PC plugged into a port but not both. If I plug in both then the phone works and the PC gets an IP address (Broadcast traffic) but PC cannot browse the network.
I have downloaded the new firmware for the SG500. I see there are two files included in the download, a boot file (rfb) and regular firmware image (ros). I have looked and haven't seen anything about the rfb files. I know it is a boot file, but do not know if I should update the boot file first and then the firmware image or vice versa. Also, in my update screen on the SG500, the boot file option is greyed out.
I am setting up a 3 host ESXi cluster. I am using a pair of stacked SG500-28 switches for switching redundancy. Each host has 8 NICs. 4 to each switch. I have successfully setup a 3 NIC LAG with 1 path to one switch and 2 paths to the other. These LAGs work. When I setup a 2NIC LAG via the console for management, and the associated ports on the switches, I lose managment communication with the host. Before setting up the LAG in the ESXi console, I set that vswitch properties to us IPHASH as instructed here bit.ly/VLaTEt I have attempted to follow those instructions as closely as possible. The one thing that I am wondering is whether the SG series supports etherchannel. I can't find any reference. Either way, it works on the other vswitch that is for vMotion. I can vmkping between the hosts over that LAG. But setting up a LAG on the management vSwitch doesn't?
I am currently running two SGE2010 in stack and planning to purchase new Sg500 .I have two questions :
1. If these two different products can be managed as one stack. 2. Are the SFP (mini-GBIC) connections compatible and if so what accessories or parts do we need to enable them?
I had connected a computer and NTP to the SG500. i had successfullly sync the internet time on the computer. but when i type 'show clock' on the terminal. The switch did not manage to sync the ntp time.
We have a problem with NLB on a SG500-28P which is a major issue for us.
I am investigating a problem together with Microsoft Support about a download/upload performance issue with a Microsoft Forefront TMG array which is connected to a single SG300-28P. Àpparently this issue exist on every NLB array we implement. I am now at the point we asume the SG500-28P does not handle NLB in unicast mode very well.
We have a network topology as shown below:Please note the actual public IP Addresses are hidden and the internal IP Addresses are diffrent, for security reasons.
Our SG500-28P is configure in L3 mode. It hosts three subnets you see above. The two TMG servers are configured with NLB (in unicast mode) on the Internal Network and External Network interface. It is connected to the internet and our internal network. These TMG Servers are in fact Edge Servers. Our other servers and client are in a different VLAN. The default gateway flows through this NLB Cluster [10.250.0.254].
Problem: When a client uses its default to connect to the internet the performance is very and very slow. With an internet connection of 10/10 we get 10/2. With an internet connection 100/100 we only get 7/1!.
Now we have tried everyting we can imagine. I can't write down all, because that would be a lot. One thing is worth notice; When we move the client to the same VLAN as the NLB Cluster and the client uses 10.250.0.1 as its default gateway, the problem still exists. But... when the client uses 10.250.0.254 as its default gateway the performance is outstanding 95/95! Apparently if traffic for the NLB Cluster is routed through the SG300-28P the performance drops like a rock.
I have never seen this before with SG300 series switches, although this environment is different. Normally I would configure NLB in multicast mode. But the switch does not allow to add static ARP entries for multicast MAC Addresses.I know NLB in unicast mode introduces switch flooding and such. But why does the SG500 not handle this right? Is there anything I can do about it?
Currently, my Cisco DPC3010 cable modem is connected directly to one of the Ethernet ports on my Linux router. All works quite well that way. However, I'm curious to know if there's some what to separate the router and cable modem over 2 switches?
The coax enters the house in my living room and connects to the CM there. The router is also sitting in the living room, and it's connected to a Cisco SG200-18 switch. I have Ethernet running from my living room to my basement, where a Cisco SG500-24 switch sits. The two switches are connected via a 2xGigE port channel.
I want to move the router into the basement. Ideally, I'd like to move the CM down there with it, but I don't have the necessary coax run. So for now, that's out. But... can I go from something like this:
I tried it, complete with a separate VLAN specifically for the CM traffic. And the VLAN was properly trunked between the two switches. But for some reason, the router was unable to communicate via IP to the upstream. I'm not sure if there are config bits I need to set on the SG200 that the CM is connected to? I thought I'd read somewhere that CMs don't like broadcast technology such as LLDP and/or CDP, so I disabled both of those on its port. Did I miss something else perhaps? Or am I trying to do the impossible?
For what it's worth: the IP connectivity is static. There's no DHCP running between my router and the upstream cable provider. The cable modem is literally acting as a L2 coax-->Ethernet convertor, more or less.
I currently have a stack of 3750G switches with a cross stack etherchannel connected to a 3750E stack in the distribution layer.The 3750G stack is running 15.0-2SE IP Base. I began noticing the Mac flap issue when I was Re-enabling dot1x on the switchports. As first I thought dot1x maybe have contributed to this so I removed it from the stack temporarily.I am still seeing Mac flap logs usually when a machine reboots or re-connects back to the network. These are all wired desktops.I started looking at the etherchannel configuration which is using LACP. The 3750E stack looks fine with all ports in mode active. On the problematic 3750G stack I noticed 3 of the ports in the etherchannel set to mode active and 1 port set to mode passive. The port shows as bundled but I can't imagine this is ok.The only other difference on this one port is there is no mls qos commands like on the other 3 interfaces in the port channel.I mainly need to know what the Mac flapping is about. Whether it is a bug or related to the current etherchannel configuration.
I have a switch from SG 500 Series the works as Layer 3 Routing Switch with the Firmeware 1.2.7.76. I have create some diferent VLAN´s and have defined one ACL for each VLAN. Now i try to do a binding from the ACl to a VLAN but i have only the option to bind the ACL to a phys. Interface or a LAG.is the a possibility to bind the ACL to a virtual interface like in other Cisco serieses and how it works ? the Backround is i have connectetd 2 Hyper-V Server where the Guests are in different VLAN´s and the server is connectetd with a 10Gb Trunk to the Switch now the switch routed the different VLAN´s and i must have some restrictions between the VLAN´s.
At our office we have a weird performance problem with the following switches and connectivity:
Internet | SG300-24 (L3) core switch (in our server room) |SG300-10P (L2) access swtich (in our meeting room) | SG500-28P (L3) switch (in our meeting room)
We are building a new computer infrastructure that is connected to the the SG500-28P. As you can see above the SG500-28P in our meeting room has an uplink to the SG300-10P in the same meeting room. And again the SG300-10P has and uplink to the SG300-24 in our server room. From the server room, there is connectivity to internet. The network uses a multiple VLAN's and routeing between them. Bootom line is, the internet VLAN ID 10 is tagged to trunk ports and available on the SG500-28P. So client get connected straight into the internet based VLAN.
The performance on the SG500-28P switch itself from VLAN to VLAN is very fast. But... the uplink connection tot the internet and other VLAN's on the core switch are very and very slow! At least 10 times slower than normal. So if I plug a laptop in the SG500-28P and go from uplink to uplink, it is slow! But... when I connect the same laptop to the SG300-10P the connection with only one uplink it is fast. As if three switches is to much. I can't figure out why.
I have an SG-200-8 which connects to a stacked pair of SG500-28P switches. It is powered by PoE from the SG500. From the SG500 the port appears Up, but at the the SG200 it is disabled and nothing I do re-enables it. I know the cable is good because I had a previous netgear switch hanging off it and working, also the power gets through.I can only connect to the switch if I disable wifi and plugin a manually configured PC - DHCP doesn't get through to it from the SG500 end.I have tried a second SG200 same problem. Have disabled RSTP/ STP thinking it might to relate to the fact that a PC connected to the switch also had a wifi connection to the same LAN, but. Don't know where to go next. looks like a bug?
The swtich is configured and going to operate in L3 mode. All ports are still assigned to the default VLAN ID 1. I have created several new VLAN's. Once I configure and aplly an IP Interface to a certain VLAN the swtich becomes inaccessable right away. I am pretty sure I am not pulling my own VLAN under my connection. Every port is inaccessable. I have to pull the power plug and restart the swtich with its saved configuration. Even when I add another IP interface to the default VLAN 1, same issue. I have tried lot's of things, but can't get it to work properly. I have just upgraded to the latest firmware.
I have configured dozens of SG300 swtiches which is very easy. This one does not work with me.
I have an SG500 that is already deployed with some Access VLANs on it. The PVID is still the default 1. I am trying to change it to 19 with as little interruption as possible. If I just go to the VLAN Management Tab and change the Default VLAN to 19 and reboot the switch, will it migrate my management IP to the default VLAN without any trouble? Would it be less interruption to: Create VLAN 19, assign it an out of subnet IP address, change a port to PVID 19, connect directly to that port, go to that IP address, remove the original management IP from PVID1, change all the ports to PVID19 then change the management IP back to the original?
Is there a way to ask the above switch how much power it's supplying to various ports?I've found some stuff in POWER-ETHERNET-MIB, but it's only the main power supply and the up/down status of the various ports.
It looks like what I want is
[URL]
but my SG500 tells me:
snmpwalk -v2c -cpublic serverswitch 1.3.6.1.4.1.9.9.402 CISCO-SMI::ciscoMgmt.402 = No Such Object available on this agent at this OID
I upgraded my SG500 switch firmware to 1.3.0.59, since there is a new functionality DHCP server v.4 well I must say I came accross the issue I cannot solve. DHCP server assign dynamic address - no hassles. troubles start with static IP hosts.I defined a couple of hosts with static address within the correct subnet. I tried with hardware address and client identifiers. no luck. my switch does not assign the IP address I assigned to the suitable mac address. to define it I use both CLI & Web.
ip dhcp pool host HP-Elliteaddress 10.10.11.7 255.255.255.0 client-identifier 01:d8:d3:85:cf:09:72client-name HP-Ellitedefault-router 10.10.11.1exit ip dhcp pool host VAIO-Zaddress 10.10.14.108 255.255.255.0 hardware-address 54:53:ed:1c:a1:46 default-router 10.10.14.1exit