Cisco Switching/Routing :: How Many Switches Can Be Stacked With WS-C2960S-48FPD-L At A Max
May 28, 2012
How many Switches can be stacked with WS-C2960S-48FPD-L at a max..
As per my Knowledge it is 4 and as below..
Switch 1 to Switch 2
Switch 2 to Switch 3
Switch 3 to Switch 4
Switch 4 to Switch 1
If yes then, is it mandatory to do the "Switch 4 to Switch 1" stack. why am I asking this is because this stack requires a long cable and the cable which comes with the Switch is only 0.5M.
View 3 Replies
ADVERTISEMENT
Apr 2, 2012
My company is beginning to have a lot of sites were we are stacking 3 to 4 C2960S-48 switche.This is making "show running-config" very very long because of the 4 x 48 interfaces.I can’t find a CLI command that show me the running-config of a ranges of interfaces. If I for example would like to see running-config for switch 3 (interfaces 3/0/1-52)The Show Running-config will show all the interfaces (for the two first swtiche = 104 interfaces), which take a time before I reach to switch 3.I miss a CLI command like: show Running-config switch 3, or module 3, or show running-config interface range x/x/x-x ?I’m well aware of the CLI command show running-config interface x/x/x, but this will only show me one interface.
View 3 Replies
View Related
Feb 25, 2013
I have two 3750x stacked switches , both with the latest firmware on them. I enter the configuration onto one switch and it obviously copies over onto the other switch. Although in the configuration I have both a console username and password and an enable password, when I try to log onto the initial switch that I entered the configuration on, I am prompted for a username and password, which works fine, but when I try to enter enable mode i get an error stating that no password has been set. However when logging onto the other switch I am not prompted for a username or password but when I try to enter enable mode I am prompted for a password and can access it with no problems.
View 1 Replies
View Related
Dec 18, 2012
I was looking at WS-C2960S-48FPS-L (740 Watts) and WS-C2960S-48LPS-L (340 Watts) models today, I'm not sure that I understand it right,
Does WS-C2960S-48FPS-L model support all 48 ports POE+ (30Watts)? Does that mean each port will get 30 Watts on this switch?
Does model WS-C2960S-48LPS-L support 24 ports with POE and 24 ports with POE+?.
View 4 Replies
View Related
Jan 16, 2012
find out which types of fiber optic that i can connect to three types of switches. the setup that i have that there are:8 access switches (WS-C2960S-24TS-S), in each one there is two SFP connections.2 aggregate switches WS-C3750X-24T-S, in each one there is four SFP connections.and one core switches that has SFP card WS-X4624-SFP-E? Note that the fiber optic that we have coming from filed are multimode.
View 2 Replies
View Related
Jul 8, 2012
Our network administrator restricts all our new 1Gb switches to only 100Mb, to which he claims it will increase overall performance. Preventing devices from bottlenecking the network. (that is, only restricting the main switch ports, not the uplinks)For example we have a new building with 2x WS-C2960S-48TS-L connected together with FlexJack and then a 1Gb Fiber connection back to our core switch.
This building is on it's own subnet and there is little broadcast traffic. I don't see the point other than it hinders the potential speed we could use. Labs are set up in this building and 1Gb is MUCH faster when it comes to imaging and software deployment.
View 8 Replies
View Related
Apr 15, 2012
Im trying to stack 2 3750E-24PD-S and 2 3750X-12S-S. The 2 3750E finds eachother and stacks with one master as they should. The problem is that and the 3750X does the exact same thing instead of joining the 3750E stack.Both runs the same IOS (c3750e-ipbasek9-mz.122-58.SE2).The stackingcables are connected like following atm (I tried booting up the switches one at a time and all at once, no difference in the result).
View 8 Replies
View Related
Jan 2, 2012
If we have 3 stacked 3750s# running Layer 3. Do we need license for every switch? or is it one license for the 3 switches? Also is the license associated with the MAC address of a specific switch? What i# am trying to know also, is if we have to install one license and it is associated# with one MAC and this switch failed.. will the Layer 3 be broken?
View 1 Replies
View Related
Dec 16, 2012
We have 3 SG500-52 switches that are stacked and configured for layer 3 that replaced a couple of SG2010 switches a month ago. Switch units 1 and 2 are for servers and unit 3 for the workstations. The switches are connected with stacking SFP+ copper cables, 1 1M and 2 7M cables. The problems are occurring between the workstations and servers resulting in slow traffic on some links and connection failures. A repeatable failure occurs doing a backup from a PC on unit 3 to a server on unit 1 and 2 (2 port LAG). Moving the workstation to a port on unit 1 results in successful backups every time.
Initially I was able to confirm packet loss between my PC (on unit 3) and the servers using ping (ping -f -c 100000 -s 1460) of about .1%. The iperf program in udp mode also showed some packet loss and in tcp mode showed slow connections. A week ago I then upgraded the switches from v1.2.0.97 to v1.2.7.76 and rebooted. After that the ping and iperf tests show no problems although there are still slow connections to samba shares and the backups still consistently fail.
I suspect there is a problem with the stacking connections and have searched for traffic statistics on the stacking ports to look for errors but have not found anything. Doing a snmpwalk didn't reveal anything that I recognized. There are interface counters for all the ports except the stacking ports.
View 4 Replies
View Related
Feb 27, 2013
I currently have a stack of 3750G switches with a cross stack etherchannel connected to a 3750E stack in the distribution layer.The 3750G stack is running 15.0-2SE IP Base. I began noticing the Mac flap issue when I was Re-enabling dot1x on the switchports. As first I thought dot1x maybe have contributed to this so I removed it from the stack temporarily.I am still seeing Mac flap logs usually when a machine reboots or re-connects back to the network. These are all wired desktops.I started looking at the etherchannel configuration which is using LACP. The 3750E stack looks fine with all ports in mode active. On the problematic 3750G stack I noticed 3 of the ports in the etherchannel set to mode active and 1 port set to mode passive. The port shows as bundled but I can't imagine this is ok.The only other difference on this one port is there is no mls qos commands like on the other 3 interfaces in the port channel.I mainly need to know what the Mac flapping is about. Whether it is a bug or related to the current etherchannel configuration.
View 9 Replies
View Related
Mar 17, 2013
I have a customer who just bought a pair of N5K and wanted to replace his current HP E3800 as Core. He wants to use the 4 x stacked HP E3800 connect back to the N5K. Will I be able to utilize VPC through a bundled 2 or 4 x 10G (40G) connection (10 or 20G on 1 switch, and 10 or 20G on another switch) from the stacked HP E3800s to the N5548s? I know you can do that with Cisco 3750s.
View 1 Replies
View Related
Jul 16, 2012
We have two 3750-x stacked switches with IP base license. We need to upgrade them to IP services license. I read some where that it is possible to install IP serivces license to only management switch and no need to purchase/install same license to other switches on the stack. But, I could not find/recall where I read it and as far as I know it was not official cisco documentation.
View 1 Replies
View Related
Jun 3, 2013
I was wondering what general steps might be taken in order to "replace two(2) 3750 (stacked) with one (1) 3750X - Server Access". General steps and what I might have to do configuration wise. I know i'm copy pasting the existing configs into the new switch, but are there any caveats?
View 5 Replies
View Related
Apr 13, 2011
I just upgraded several of my C2960S-48FPD-L from 12.2(55)SE to 12.2(58)SE and now almost every time I try to SSH to it the switch reboots and gives me these trace backs ...
07:58:52 CST Thu Apr 14 2011: Unexpected exception to CPU vector 200, PC = 1EADA28
-Trace back= 0x1EADA28z 0x1CDC324z 0x1EA5520z 0x1CDC35Cz 0x1CDD0E0z 0x1CDF0C4z 0x1CE06CCz 0x1CE07F8z 0x1D67348z 0x1D611BCz
Writing crash info to flash:/crashinfo_ext/crashinfo_ext_3
07:58:56 CST Thu Apr 14 2011: Unexpected exception to CPU vector 1100, PC = 121BB98
-Trace back= 0x121BB98z 0x12250FCz 0xFA7540z 0xA807B8z 0xA75DF4z 0xA78080z 0x94B708z 0x9717C0z 0x918DD8z 0x936520z 0x9344BCz 0x9345FCz 0x93484Cz 0x1D67348z 0x1D611BCz
=== Flushing messages (07:58:56 CST Thu Apr 14 2011) ===
Buffered messages: (last 4096 bytes only)
0x00000005 R6 = 0x01224F44 R7 = 0x02A23C6C
000089: *Feb 28 18:03:13.577 CST: %PLATFORM-1-CRASHED: R8 = 0x00000080 R9 = 0x00000000 R10 = 0x00000000 R11 = 0x00000071
000090: *Feb 28 18:03:13.577 CST: %PLATFORM-1-CRASHED: R12 = 0x00034855 R13 = 0x00000280 R14 = 0x01CE0778 R15 = 0x00000000
000091: *Feb 28 18:03:13.577 CST: %PLATFORM-1-CRASHED: R16 = 0x00000000 R17 = 0x00000000 R18 = 0x00000000 R19 = 0x00000000
[ code]....
View 9 Replies
View Related
Dec 9, 2012
I am looking for a reasonable switch but it has do do inter-VLAN Routing. I know I could go with a 3560/3750 with IP Services but I am also thinking the 2960S with IP Base IOS might do?
I have looked up the IP Base IOS and it does list IP Routing but how to actually configure inter-VLAN Routing on a 2960S with IP Base?
View 2 Replies
View Related
Apr 19, 2013
I have been trying to enable L3 intervlan routing on C2960S Switch with ip routing command and that was the output from the Switch: [code]
View 6 Replies
View Related
Apr 13, 2013
We are planning to implement the redundant physical connection from 5508 WLC to not stacked 3750 switches. The sheme is attached.
View 7 Replies
View Related
Mar 21, 2012
Is there a CLI-command to see the serial number of the flexstack module installed in a C2960S.
View 13 Replies
View Related
Jun 13, 2013
We have several of these WS-C2960S-24PS-L running 12.2(55)SE5 C2960S-universalK9-M and need to upgrade to a better.IOS since we have a sitution where CPU would get to 100% but we have only a few ports connected.Also we have several of WS-C3750-48P running 12.2(55) SE6 C3750-IPBASEK9-M.
View 3 Replies
View Related
May 29, 2011
We have a 2960 stack of 4 WS-C2960S-24PS-L switches.Sometimes, at random, the stack crashes and reboots. I have downloaded the crashinfo file and can see the following error.
View 7 Replies
View Related
Mar 14, 2013
I'm trying to configure a stack between two WS-C2960S-48FPS-L but does not working.The switch port is always Down.I tried to change de module and cables.I tried to make a loop in one of two switches and the ports always down.
IOS: 12.2(55)SE5
#show switch stack-ports
Switch # Port 1 Port 2
-------- ------ ------
1 Down Down
View 15 Replies
View Related
Feb 27, 2012
We have two switches WS-C2960S-24TS-L running in stack with running IOS c2960s-universalk9-mz.122-55.SE3.We have connected two checkpoint devices on Gi1/0/24 and Gi2/0/24 with a simple configuration:
interface range GigabitEthernet1/0/24, gi2/0/24
switchport access vlan x
switchport mode access
spanning-tree portfast
On the devices log we get the following message:
%SW_MATM-4-MACFLAP_NOTIF: Host 0000.0000.fe21 in vlan x is flapping between port Gi2/0/24 and port Gi1/0/24
The mac-address 0000.0000.fe21 is not found on any checkpoint interface. "Show mac-address int gi1/0/24 or gi2/0/24" does not show the correct mac-address of the checkpoint interface connected to the port, but instead shows 0000.0000.fe21.Is there a bug in the IOS, something wrong with the switch config or does it have something to do with the checkpoint config?
View 2 Replies
View Related
Jan 14, 2013
I have a customer with a stack of two switches C2960S-24TS-L that are running 12.2(58)SE2 universal K9, we see that the CPU load increase over time, to 95% and stays there reload solves the problem.the process that akes a lot of CPU is also the SNMP ENGINE, I see that it is running 30 minutes on 95% and then 10 minutes on 35%, this is the only stack were we see this problem. Is there also a SNMP bug in this version ?
View 1 Replies
View Related
May 10, 2013
Does GLC-GE-100FX is supported on the WS-C2960S-24TD-L. I don't see this switch listed under the compatibility matrix.URL
But the datasheet for the 2960S says this:
"The Cisco Catalyst 2960-S with SFP+ does not support the GLC-FE-100BX, GLC-FE-100FX, or GLC-FE-100LX." But it provides no reference for the GLC-GE-100FX The easy answer is, no the 2960S-24TD doesn't support it, any clarification if possible.
View 1 Replies
View Related
Mar 29, 2012
is it possible to connect UCS FI directly to C2960S using Twin Ax Cable (3M long) ?
View 2 Replies
View Related
Dec 12, 2012
I have a very simple setup containing 3 C2960S switches:switch 1: central switch, acting as router between VLAN 1 en VLAN 2switch 2+3: edge switches, connected via 1 link to central switch, both on VLAN 2,Clients connect to switch 2 and 3 using dhcp, switch 1 uses dhcp relay to forward requests from VLAN 2 to the dhcp server on VLAN 1. So far so good.Now I want switch 1 to add option 82 to the dhcp requests so the dhcp server can see whether the request came through switch 2 or switch 3. I tried turning on dhcp option 82 support on switch 1 by doing.
View 2 Replies
View Related
Apr 1, 2012
WS-C2960S-24PD-LCatalyst 2960S 24 GigE PoE 370W, 2 x 10G SFP+ LAN Base
Can I use the above said switch for 1 Gig Uplinks using SFP.
View 2 Replies
View Related
Feb 12, 2012
The pinout of poe and poe+ (802.3af) and (803.3at) of these models of Cisco switches?
WS-C2960S-48FPS-L 48 Ethernet 10/100/1000 PoE+ ports; 740W PoE capacityWS-C2960S-48LPS-L 48 Ethernet 10/100/1000 PoE+ ports; 370W PoE capacityWS-C3750-48PS-S 48 Ethernet 10/100 ports with IEEE 802.3af and Cisco prestandard Power
Pin goes where the power for Poe (802.3af) and poe+ (802.3at) for this model Cisco
View 1 Replies
View Related
Jan 21, 2013
I have three new 2960 switches as listed in the title. I configured them as follows:
192.168.1.215 host: whse-c
192.168.1.216 host: whse-b
192.168.1.217 host: whse-a
Switches B and C flow into A before continuing on into the server room switch (distance issues).All three switches are configured for ports 21-24 at 1000 and set as cisco switches. all other ports are undefined as they have a myriad of desktops, printers and non cisco access points flowing into them. side question - should i configure them as access points where applicable even if they are non cisco? I am replacing three netgear switches that currently are in place and have no known issues other than they are old and the fans may fail soon.hooked up .217. was able to get to it from the network. Hooked up 215 and then 216. All the sudden I lost the ability to tap into the switches, any of them. (I think I had done 215 at that point too, before adding 216. I found out later it took the network to its knees as internet was lost, and the MPLS stopped functioning.
I undid the changes and put the netgears back in service and all was right with the world again. At first I thought it was a bad host name as I had used whse-a on switch C in error. I changed that after this issue.Later that day I put 215 in place. checked it from the network and could get to it just fine. Then I put 216 in service. I lost connection to 215. I could no longer get to the internet from my pc and the MPLS went down again. This time I just unhooked 216. 215 is still in place and working on the network at the moment and not causing issues. (btw these switches are not even in my path from my pc to the internet, just on the same network) tomorrow I am going to try 217 again while 215 is still on the network and see if there are any issues adding that swtich. if I can do so, and there are no problems, is this an indication of a faulty switch? what further testing can I do, have I missed something in setup? If this brings the network down again, why cant i add two of these switches to each other/on the same network path (B and C were not even connected to each other yesterday evening when it went down again).
View 2 Replies
View Related
Jul 24, 2012
I have a got a requirement where a 24 Port Switch should have 4 SFP's and all 4 should be used at a time, So I've chosen " WS-C2960S-24TS-L"
The transeiver should be GLC-LH-SM, so kindly let me no whether I would be able to use all 4 ports at a time or not.
View 2 Replies
View Related
Jul 1, 2011
We've have a 2 SGE2010-48 port, stacked. 4 LAGS are denifed, two on primary, whitch are working, two on slave unit are NOT working. Devices connected to LAGS are de the same and same configuration (Cisco ASA 5510).
View 3 Replies
View Related
Nov 15, 2011
I have a 4 member stack of 3750's. We would like to take advantage of wccp and we understand that we will need to upgrade our switch licensing from IPBase to IPServices. My question is do we need to pay for a license for each member in the stack or does one IPServices license upgrade cover the whole stack?
WS-C3750G-48PS
WS-C3750G-48TSWS-C3750G-48TSWS-C3750G-48TS
View 1 Replies
View Related
May 10, 2012
I am about to buy 2x Series 500 switches but before that I have a design to be sure :I want to create a redondant network so it is the reason why I want to stack 2x Series 500 switches.Each server on my network (ESX and Windows 2008) are connected with two NIC (one port on the first switch , one port on the second switch), with trunk mode + etherchannel for LACP.
First question : I saw that the limitation is up to 8 etherchanel groups, can I have a mix of multiple servers on the same etherchannel group or should I create one etherchanel group for one server with only the two NIC inside?
Second question:I want to use the series 500 to do intervlan routing and want to be sure that if the the ports are in trunk mode with some vlan set on the card itself that the default gateway for the vlan will be propagated on the two switches (in stack mode) and will not cause any issues when both switchs works fine and if one switch crashes?
View 3 Replies
View Related