Cisco Switching/Routing :: WS-C2960S-24TS-L / Mac Flapping On Stack?
Feb 27, 2012
We have two switches WS-C2960S-24TS-L running in stack with running IOS c2960s-universalk9-mz.122-55.SE3.We have connected two checkpoint devices on Gi1/0/24 and Gi2/0/24 with a simple configuration:
interface range GigabitEthernet1/0/24, gi2/0/24
switchport access vlan x
switchport mode access
spanning-tree portfast
On the devices log we get the following message:
%SW_MATM-4-MACFLAP_NOTIF: Host 0000.0000.fe21 in vlan x is flapping between port Gi2/0/24 and port Gi1/0/24
The mac-address 0000.0000.fe21 is not found on any checkpoint interface. "Show mac-address int gi1/0/24 or gi2/0/24" does not show the correct mac-address of the checkpoint interface connected to the port, but instead shows 0000.0000.fe21.Is there a bug in the IOS, something wrong with the switch config or does it have something to do with the checkpoint config?
View 2 Replies
ADVERTISEMENT
Dec 19, 2012
We have the following stack configuration:
Switch Ports Model SW Version SW Image------ ----- ----- ---------- ---------- 1 28 WS-C2960S-24TS-L 12.2(55)SE3 C2960S-UNIVERSALK9-M 2 28 WS-C2960S-24TS-L 12.2(55)SE3 C2960S-UNIVERSALK9-M 3 52 WS-C2960S-48TS-L 12.2(55)SE5 C2960S-UNIVERSALK9-M * 4 52 WS-C2960S-48TS-L 12.2(55)SE5 C2960S-UNIVERSALK9-M
View 5 Replies
View Related
Jul 24, 2012
I have a got a requirement where a 24 Port Switch should have 4 SFP's and all 4 should be used at a time, So I've chosen " WS-C2960S-24TS-L"
The transeiver should be GLC-LH-SM, so kindly let me no whether I would be able to use all 4 ports at a time or not.
View 2 Replies
View Related
Jan 3, 2012
I just received three WS-C2960S-24TS-Land three WS-C3560E-48TD-S switches that i entered the Express Setup on as usual. On two of each type of switch i found the default network that is used to facilitate the Express Setup was 10.0.1.1 and the others used an IP range of 10.0.2.1, i realized this is a small negligible at best difference though i need to provide management with an answer as to why there is a difference between the two and can’t find anything online as to why there is a difference or something that proves there should be a difference. All the documentation I find sounding Express Setup notes that the IP range will be 10.0.1.1 not 10.0.2.1
View 3 Replies
View Related
Jan 16, 2012
find out which types of fiber optic that i can connect to three types of switches. the setup that i have that there are:8 access switches (WS-C2960S-24TS-S), in each one there is two SFP connections.2 aggregate switches WS-C3750X-24T-S, in each one there is four SFP connections.and one core switches that has SFP card WS-X4624-SFP-E? Note that the fiber optic that we have coming from filed are multimode.
View 2 Replies
View Related
Nov 2, 2011
I have a situation. I am running two-switch 3750-stack and it crashed this morning. IOS version the switches is: "flash:c3750-ipservicesk9-mz.150-1.SE.bin"
SRPRSRGBYA#
Log Buffer (10000 bytes):
3:40.840: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan104, changed state to up
Nov 3 13:13:40.840: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan201, changed state to up
Nov 3 13:13:40.840: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan202, changed state to up
M-1-CRASHED: (SRPRSRGBYA-1)
Nov 3 13:18:13.336: %PLATFORM-1-CRASH(code)
View 3 Replies
View Related
May 29, 2011
We have a 2960 stack of 4 WS-C2960S-24PS-L switches.Sometimes, at random, the stack crashes and reboots. I have downloaded the crashinfo file and can see the following error.
View 7 Replies
View Related
Mar 14, 2013
I'm trying to configure a stack between two WS-C2960S-48FPS-L but does not working.The switch port is always Down.I tried to change de module and cables.I tried to make a loop in one of two switches and the ports always down.
IOS: 12.2(55)SE5
#show switch stack-ports
Switch # Port 1 Port 2
-------- ------ ------
1 Down Down
View 15 Replies
View Related
Jan 14, 2013
I have a customer with a stack of two switches C2960S-24TS-L that are running 12.2(58)SE2 universal K9, we see that the CPU load increase over time, to 95% and stays there reload solves the problem.the process that akes a lot of CPU is also the SNMP ENGINE, I see that it is running 30 minutes on 95% and then 10 minutes on 35%, this is the only stack were we see this problem. Is there also a SNMP bug in this version ?
View 1 Replies
View Related
Jan 30, 2012
WS-C3750G-24TS-S1U switch stack with high CPU utilization. 3 switches are stacked and using PBR on that. I am attaching the show cpu process as an attachment.The current template is "desktop routing" template.The selected template optimizes the resources in the switch to support this level of features for 8 routed interfaces and 1024 VLANs. [code]
View 0 Replies
View Related
Dec 16, 2012
I have a Cisco WS-C2960S-48TD-L with 12.2(55)SE2.This is a standalone switch, not in stack, and with no order it reboots itself looking for a new master election. On logging i have nothing, but connected with console cable i see the following after 2 minutes of not showing anything:
Waiting for Stack Master Election...
...
The switch reboots and:
...
*Mar 1 00:00:12.289: Read env variable - LICENSE_BOOT_LEVEL =
[URL]
After searching online i have no seeing nothing about disable the feature of the stack so i configure the priority for the "switch 1" to 15 and configure it the switches 2, 3 and 4 to no provision, although this switches don´t exist:
SW_ACCESS(config)#switch 1 priority 15
Changing the Switch Priority of Switch Number 1 to 15
Do you want to continue?[confirm]
New Priority has been set successfully
[URL]
With this new configuration the switch has rebooted again.Why on a standalone switch the stack is rebooting my system?Is it any feature to disable the stack?
View 8 Replies
View Related
Aug 27, 2012
I am receiving the following error message on a Cisco 3750 switch stack. Need troubleshooting this error message.
00:03:13: %SW_MATM-4-MACFLAP_NOTIF: Host 00d0.7400.2730 in vlan 600 is flapping between port Gi2/0/3 and port Gi2/0/2
View 3 Replies
View Related
Mar 11, 2012
I have an issue with a Cisco 3750 switch stack which is connected to two seperate upstream Cisco 3750's which are administered by an ISP. The ISP is experiencing MAC address flapping from one of my VLAN SVI's i am using to route traffic upstream
[code]...
As you can see I utilise a VLAN SVI to route traffic to the upstream 1.1.1.2 (illustration only) IP. As per the diagram of the topology attached, the ISP is receiving a MAC address flapping error confirming the SVI MAC address from my switch stack is being learnt on the trunk port connecting switch 1 and switch 2, and also the port (Gi1/0/48) directly connected to my switch stack. As these are all Layer 2 links essentially being passed upstream and then connected between the two ISP switches, we have a 3 way triangular loop formed.
If I was to remove the port channel configuration from the two ports associated with the VLAN SVI, am i right in suggesting this would still form a layer 2 loop? The two ports would still be a member of the SVI VLAN, and it is the VLAN MAC address which is being learnt by the two ISP switches on different interfaces.
View 2 Replies
View Related
Jun 5, 2012
is possible to have WS3750G-24PS in one stack with WS-C2960S-24PS? I want to add two new WS-C2960S-24PS to stack with one WS3750G 24PS.
View 1 Replies
View Related
Feb 2, 2012
I need to compare a cisco ws-c2960s-24TS-s with a PowerConnect 6224, the scenario is to interconnect SAN ISCSI to 1G in RJ45.
View 1 Replies
View Related
Mar 6, 2012
I am facing the following issue. In our environment we have a couple of WS-C2960S-24TS-L configured as stack. These switches are configured as VTP mode transparent.We are running LMS 4.1 and although UserTracking Acquisition works fine for all other switches, it only runs on demand for the above. The user tracking report for these switches shows only the MAC of the connected end hosts, without the respective IP address. The vlan I am interested in is configured on both the gateway (cisco 6509) and the switches, and the subnet is routable.Show arp on the gateway does show the "mac-ip address" binding, so I would have thought that usertracking would have been able to report both IP and MAC.
Why does usertracking only run on demand for the above switches in vtp mode transparent?Why does the UserTracking report show only the MAC and not the IP?Are the above issues related to the vtp mode? I have ruled out any connection to the switch-model, because we have recently installed the same switches in VTP mode client and User Tracking Acquisition works fine for them.
View 3 Replies
View Related
Feb 17, 2012
I have the following switch:
#show version
Cisco IOS Software, C3750 Software (C3750-IPSERVICES-M), Version 12.2(52)SE, RELEASE SOFTWARE (fc3)
Copyright (c) 1986-2009 by Cisco Systems, Inc.
Image text-base: 0x01000000, data-base: 0x02C00000
ROM: Bootstrap program is C3750 boot loader
BOOTLDR: C3750 Boot Loader (C3750-HBOOT-M) Version 12.2(44)SE5, RELEASE SOFTWARE (fc1)
[code]...
I have downloaded c3750-ipservicesk9-mz.150-1.SE2.bin and I want to upgrade iOS to this image.
I have a few questions related to this:
1. Is my switch model compatible with this iOS version?
2. Do you recommend the upgrade? Does it bring some notable features?
3. Can I upgrade for free or do I need to buy some license?
4. I also want to upgrade/add the crypto image, can I add crypto for free or some license is required?
5. I have remote access to my switch via the console cable which plugged into machine1. But machine1 is connected to network via the same switch. I am accessing machine1 via SSH, and then the switch via console cable (minicom on CentOS). Is there an upgrade procedure for this kind of situation that also has some fall back (like reboot in X minutes and load the previous image) if the upgrade goes wrong?
View 6 Replies
View Related
Feb 27, 2013
Is there a stacking cable that is "bent"?Im using this cable:"CAB-STACK-50CM", "Cisco StackWise 50CM Stacking Cable".But it takes up to much room in the back of the switch, is there such a thing as "bent" stacking cable.
View 1 Replies
View Related
Oct 31, 2012
I have 3 switches in my 3750 X stack. I am getting the following error in the logs: %PLATFORM_STACKPOWER-4-PRIO_CONFLICT: Switch 1's power stack has conflicting power priorities. Not sure what I should do next. Below is my Stack-power configuration:
Power stack name: Powerstack-1 Stack mode: Power sharing Stack topology: Ring Switch 1: Power budget: 735 Low port priority value: 20 High port priority value: 10 Switch priority value: 2 Port 1 status: Connected Port 2 status: Connected Neighbor on port 1: c464.1308.7900 Neighbor on port 2: e8b7.4827.e680
Switch 3: Power budget: 729 Low port priority value: 22 High port priority value: 13 Switch priority value: 4 Port 1 status: Connected Port 2 status: Connected Neighbor on port 1: 2894.0fd9.9f00 Neighbor on port 2: 2894.0fd8.e200
Switch 2: Power budget: 690 Low port priority value: 21 High port priority value: 12 Switch priority value: 3 Port 1 status: Connected Port 2 status: Connected Neighbor on port 1: 2894.0fd8.e200 Neighbor on port 2: c464.1308.7900
Each switch has its own 715W power supply in it and all check out OK.
View 3 Replies
View Related
Sep 24, 2012
A site that i am responsible for has the following equipment installed:
2 x 3750G Switches configured as a stack using Stackwise - Collapsed Core/Distribution Layer
5 x 2960G Switches as Access Layer switches
WAN connections into the Core/Distribution Layer are all Gigabit Ethernet over Fibre.This is a dedicated CCTV Network with 50 Cameras all streaming video into the Core (decoders connected to access switches)Each 2960G has 2 links to the Core/Distribution 3750G Switches, 1 to each switch - Gigabit.I'm running rapid-pvst on all switches, so spanning tree is blocking one of the ports and effectively halving the 2 gig bandwidth. Next year our customer is going to add in a further 50 - 60 cameras.After monitoring the current loading on the ports in use, we have suggested to the customer that the 2 connections to each should be Ether-channeled together. [code]
First interface takes commands no problem, keep getting the message that etherchannel cannot be configured across different switches in a stack when i try to put the second interface commands on.
View 8 Replies
View Related
Feb 6, 2012
I'm troubleshooting interface drops. However the output of the following show commands don't match number of drops. Based on the output, can you find out what is causing the drops? the G1/0/28 is the uplink. Is that just the port got overrun by the traffic?
#show int g1/0/28
GigabitEthernet1/0/28 is up, line protocol is up (connected)
Hardware is Gigabit Ethernet, address is 0019.5667.191c (bia 0019.5667.191c)
[Code].....
View 7 Replies
View Related
Jan 2, 2013
getting CPU utilization around 62%
CPU utilization for five seconds: 54%/6%; one minute: 61%; five minutes: 61%
PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process
35 82081 9642 8512 0.31% 0.21% 0.18% 0 Compute load avg
[Code]....
View 1 Replies
View Related
May 9, 2013
I have problem with my cisco switch 2970.
Initializing flashfs...
flashfs[1]: 5 files, 1 directories
flashfs[1]: 0 orphaned files, 0 orphaned directories
flashfs[1]: Total bytes: 15998976
flashfs[1]: Bytes used: 5935616
[Code]...
View 2 Replies
View Related
May 1, 2012
how to reset password on WS-C3560G-24TS?
View 1 Replies
View Related
Jan 20, 2013
Inter-VLAN applications are slow and same VLAN it is working fine.(i.e.VLAN to VLAN applications and File transfer response was Slow).Switch Model number: WS-C3750G-24TS-S1U
View 3 Replies
View Related
Apr 10, 2012
Is there a way I can downgrade the firmware on a C3750 v2 switch 24TS-S v07 to 12.2(35) SE5. I have added this new switch to an existing stack but the FW is not compatable. I believe the answer is to upgrade the rest but I cannot afford any down time as they are used to run a CCTV securiy network 24/7. I have included details below to assist with my problem. Switch 4 is the one with a version miss match.
LNB-SWI3750-CTR-01#show verCisco IOS Software, C3750 Software (C3750-IPBASE-M), Version 12.2(35)SE5, RELEASE SOFTWARE (fc1)Copyright (c) 1986-2007 by Cisco Systems, Inc.Compiled Thu 19-Jul-07 19:15 by nachenImage text-base: 0x00003000, data-base: 0x01080000
ROM: Bootstrap program is C3750 boot loaderBOOTLDR: C3750 Boot Loader (C3750-HBOOT-M) Version 12.2(25r)SEE4, RELEASE SOFTWARE (fc1)
LNB-SWI3750-CTR-01 uptime is 19 weeks, 3 days, 22 hours, 46 minutesSystem returned to ROM by power-onSystem image file is "flash:c3750-ipbase-mz.122-35.SE5/c3750-ipbase-
[code]....
View 5 Replies
View Related
Jun 28, 2012
I need to configure the C3560-24TS, QoS control by IP or subnet.i tried to study books and videos many times but still feel i am not well known about QOs...
View 1 Replies
View Related
Apr 13, 2011
I just upgraded several of my C2960S-48FPD-L from 12.2(55)SE to 12.2(58)SE and now almost every time I try to SSH to it the switch reboots and gives me these trace backs ...
07:58:52 CST Thu Apr 14 2011: Unexpected exception to CPU vector 200, PC = 1EADA28
-Trace back= 0x1EADA28z 0x1CDC324z 0x1EA5520z 0x1CDC35Cz 0x1CDD0E0z 0x1CDF0C4z 0x1CE06CCz 0x1CE07F8z 0x1D67348z 0x1D611BCz
Writing crash info to flash:/crashinfo_ext/crashinfo_ext_3
07:58:56 CST Thu Apr 14 2011: Unexpected exception to CPU vector 1100, PC = 121BB98
-Trace back= 0x121BB98z 0x12250FCz 0xFA7540z 0xA807B8z 0xA75DF4z 0xA78080z 0x94B708z 0x9717C0z 0x918DD8z 0x936520z 0x9344BCz 0x9345FCz 0x93484Cz 0x1D67348z 0x1D611BCz
=== Flushing messages (07:58:56 CST Thu Apr 14 2011) ===
Buffered messages: (last 4096 bytes only)
0x00000005 R6 = 0x01224F44 R7 = 0x02A23C6C
000089: *Feb 28 18:03:13.577 CST: %PLATFORM-1-CRASHED: R8 = 0x00000080 R9 = 0x00000000 R10 = 0x00000000 R11 = 0x00000071
000090: *Feb 28 18:03:13.577 CST: %PLATFORM-1-CRASHED: R12 = 0x00034855 R13 = 0x00000280 R14 = 0x01CE0778 R15 = 0x00000000
000091: *Feb 28 18:03:13.577 CST: %PLATFORM-1-CRASHED: R16 = 0x00000000 R17 = 0x00000000 R18 = 0x00000000 R19 = 0x00000000
[ code]....
View 9 Replies
View Related
Dec 9, 2012
I am looking for a reasonable switch but it has do do inter-VLAN Routing. I know I could go with a 3560/3750 with IP Services but I am also thinking the 2960S with IP Base IOS might do?
I have looked up the IP Base IOS and it does list IP Routing but how to actually configure inter-VLAN Routing on a 2960S with IP Base?
View 2 Replies
View Related
Nov 15, 2012
I am confused about some things regarding the different IOS versions and their compatibility with certain switch hardware. I understand the differences between the IPBASE and IPSERVICES ios but am not quite clear as to how you can tell which ios images will work on which Cisco switch model platforms, other than the fact that some switches are designed only to run the IPBASE images and others have advanced hardware to run the advanced images. For instance, if I have a 3750-24TS-E with an IPBASE ios on it, can I load an IPSERVICES ios that came from say a 3750G-24TS-E1U? whether the ios on one platform can be transferred to another?
View 5 Replies
View Related
Mar 17, 2012
Got 2 of these switch stacked and there is some changes that we are going to undertake which will require us to utilize the whole 8 or 4 (2 from each switch) SFP ports. Just need some adivce on which particular fiber modules should I procure. Does this switch support 10GB of SFP ?
View 7 Replies
View Related
Mar 23, 2013
Devices are 3750-24TS Switches, software version is 12.2(55)SE6. how to troubleshoot this issue, I have a pair of ports which are not bundling, no matter what. Is the same behavior with LACP or PAgP. In this outputs I have only the PAgP case.
Output is similar to:
Group Port-channel Protocol Ports
------+-------------+-----------+-----------------------------------------------
12 Po12(SD) PAgP Fa1/0/23(I) Fa1/0/24(I)
Configuration on ports is simple:
SW1:
interface FastEthernet1/0/24
switchport trunk encapsulation dot1q
switchport mode trunk
channel-group 12 mode desirable
[code]....
View 3 Replies
View Related
Oct 16, 2012
We have a stack of 4 Cisco WS-3750G-24TS with Sw Version 12.2(52) SE and giving weird errors:-
-Traceback= 17211C8 16FA4C0 16FA4FC 18625E4 18608D4 286A850 283E6FC 282EDF4 2859BBC 1B2EDA8 1B25878
Oct 17 22:26:48 AEDT: %SNMP-3-CPUHOG: Processing GetBulk of lldpRemEntry.7
Oct 17 22:26:50 AEDT: %SYS-3-CPUHOG: Task is running for (2098)msecs, more than (2000)msecs (8/6),process = SNMP ENGINE.
-Traceback= 172108C 17211CC 16FA4C0 16FA4FC 18625E4 18608D4 286A850 283E6FC 282EDF4 2859BBC 1B2EDA8 1B25878
Oct 17 22:26:51 AEDT: %SNMP-3-CPUHOG: Processing GetBulk of lldpRemEntry.7
Oct 17 22:26:53 AEDT: %SNMP-3-CPUHOG: Processing GetBulk of lldpRemEntry.6
Oct 17 22:26:53 AEDT: %SYS-3-CPUHOG: Task is running for (2097)msecs, more than (2000)msecs (1/1),process = SNMP ENGINE.
What are these errors is this a bug in the IOS
View 1 Replies
View Related