Cisco Switching/Routing :: WS-3750G-24TS - Switches Logs Showing CPU Errors
Oct 16, 2012
We have a stack of 4 Cisco WS-3750G-24TS with Sw Version 12.2(52) SE and giving weird errors:-
-Traceback= 17211C8 16FA4C0 16FA4FC 18625E4 18608D4 286A850 283E6FC 282EDF4 2859BBC 1B2EDA8 1B25878
Oct 17 22:26:48 AEDT: %SNMP-3-CPUHOG: Processing GetBulk of lldpRemEntry.7
Oct 17 22:26:50 AEDT: %SYS-3-CPUHOG: Task is running for (2098)msecs, more than (2000)msecs (8/6),process = SNMP ENGINE.
-Traceback= 172108C 17211CC 16FA4C0 16FA4FC 18625E4 18608D4 286A850 283E6FC 282EDF4 2859BBC 1B2EDA8 1B25878
Oct 17 22:26:51 AEDT: %SNMP-3-CPUHOG: Processing GetBulk of lldpRemEntry.7
Oct 17 22:26:53 AEDT: %SNMP-3-CPUHOG: Processing GetBulk of lldpRemEntry.6
Oct 17 22:26:53 AEDT: %SYS-3-CPUHOG: Task is running for (2097)msecs, more than (2000)msecs (1/1),process = SNMP ENGINE.
What are these errors is this a bug in the IOS
View 1 Replies
ADVERTISEMENT
Feb 6, 2012
I'm troubleshooting interface drops. However the output of the following show commands don't match number of drops. Based on the output, can you find out what is causing the drops? the G1/0/28 is the uplink. Is that just the port got overrun by the traffic?
#show int g1/0/28
GigabitEthernet1/0/28 is up, line protocol is up (connected)
Hardware is Gigabit Ethernet, address is 0019.5667.191c (bia 0019.5667.191c)
[Code].....
View 7 Replies
View Related
Mar 17, 2012
Got 2 of these switch stacked and there is some changes that we are going to undertake which will require us to utilize the whole 8 or 4 (2 from each switch) SFP ports. Just need some adivce on which particular fiber modules should I procure. Does this switch support 10GB of SFP ?
View 7 Replies
View Related
Feb 7, 2011
I have two 3750G switches that are in a stack, and I am seeing these errors in the log:
002258: Feb 4 17:06:06.355 UTC: %PM-3-INTERNALERROR: Port Manager Internal Software Error (vlanid >=0 && vlanid < PM_MAX_VLANS: ../switch/pm/pm_vlan.c: 1279: pm_vlan_get_vlan_data) (CBAC01-3750-2)
-Traceback= 190F078 19729A0 1972A64 1963764 110BC24 195F2F8 110BB9C 196D2C8 195ECD4 110BC24 19658B0 110BB9C 196D1D8 194C2B8 195D24C 110BC24 (CBAC01-3750-2)
002259: Feb 4 17:06:06.355 UTC: %BIT-4-OUTOFRANGE: bit 4096 is not in the expected range of 0 to 4095 (CBAC01-3750-2)
-Traceback= 10273BC 1027478 1972B50 1963764 110BC24 195F2F8 110BB9C 196D2C8 195ECD4 110BC24 19658B0 110BB9C 196D1D8 194C2B8 195D24C 110BC24 (CBAC01-3750-2)
002260: Feb 4 17:06:06.355 UTC: %PM-3-INTERNALERROR: Port Manager Internal Software Error (vlan > 0 && vlan < PM_MAX_VLANS: ../switch/pm/pm_vlan.c: 773: pm_vlan_set_portlist) (CBAC01-3750-2)
[code]....
View 9 Replies
View Related
Feb 27, 2013
I currently have a stack of 3750G switches with a cross stack etherchannel connected to a 3750E stack in the distribution layer.The 3750G stack is running 15.0-2SE IP Base. I began noticing the Mac flap issue when I was Re-enabling dot1x on the switchports. As first I thought dot1x maybe have contributed to this so I removed it from the stack temporarily.I am still seeing Mac flap logs usually when a machine reboots or re-connects back to the network. These are all wired desktops.I started looking at the etherchannel configuration which is using LACP. The 3750E stack looks fine with all ports in mode active. On the problematic 3750G stack I noticed 3 of the ports in the etherchannel set to mode active and 1 port set to mode passive. The port shows as bundled but I can't imagine this is ok.The only other difference on this one port is there is no mls qos commands like on the other 3 interfaces in the port channel.I mainly need to know what the Mac flapping is about. Whether it is a bug or related to the current etherchannel configuration.
View 9 Replies
View Related
Jan 16, 2012
find out which types of fiber optic that i can connect to three types of switches. the setup that i have that there are:8 access switches (WS-C2960S-24TS-S), in each one there is two SFP connections.2 aggregate switches WS-C3750X-24T-S, in each one there is four SFP connections.and one core switches that has SFP card WS-X4624-SFP-E? Note that the fiber optic that we have coming from filed are multimode.
View 2 Replies
View Related
Jun 12, 2012
We have to connect two 3750G switches to some HP machines. Those machines have several network interfaces, which are going to be configured in several bondings. The load balancing mode they want to configure is mode 6, alb. We have investigated and it is: [code] Receive load balancing is achieved through ARP negotiation.We would like to know if it is supported to be connected to a 3750G an if an special configuration is needed.
View 1 Replies
View Related
Jul 18, 2011
I have issue with connectivity 3750G with Dlink Switch, it cannot connect to non-cisco switch with fiber , But CISCO to CISCO switch it shows connectivity. My question is that is there any configuration on Cisco 3750G switch to connect with non-cisco switch through fiber (SFP) ?
View 2 Replies
View Related
Jan 23, 2013
I have faced a problem with configuring Cisco 3750G series switches as Sever farm switches with redudance.
servers have 2NIC (1GBps) and both are bridged for redundant connections.In both switches all ports get green coluor except one port on Secondary SW. I saw some Spanning tree block port status on that switch.when i type Show cdp neghbor command on switch i can see other switch through a server connected port. Also Spannig tree root bridge election is occured through that port . Simply i need to configure both switches to pass traffic through there uplinks them selves.. but it seems like Secondry switch pass its traffic through primary switch ( i think according to STP ) usinginterconnection of bridge port of a server. [code]
View 1 Replies
View Related
Feb 5, 2013
We have a Cisco 3750G Core switch which has physical connections, each configured as trunks to two HP Access switches. The client who uses these access switches would like to put a link between the two, but this would create a loop.
------- Core Switch -------
| |
| |
[Code]....
View 12 Replies
View Related
Nov 3, 2011
I have a 2x Cisco 3750G switches (Stacked) that are part of an IP Video Surveillance System .All network is set to 1 VLAN (VLAN 1 default).The Cisco SWs ( Core ) are configured with IGMP Querier + Snooping .Connected to the Cisco SWs are 4 Fiber Rings(Loops) for redundancy . RSTP and IGMP Snooping are enabled on all the network SWs .Network Architecture Figure :
When all Fiber Rings (Loops ) are connected , the Cisco and Ring SWs spanning-tree tables show the blocked and forwarding ports properly .I am able to connect all my IP Cams + Encoders to the Ring SWs and connect my Servers + WorkStations to the Cisco SWs to record and view the multicast ip streams .All streams from Rings 1 ,3 and 4 are getting normally to the Servers + WorkStations through multicast ( IGMP Snooping are filled correctly on the Cisco and non-Cisco SWs ) . All multicast streams are joined normally except for Ring 2 .The Multicast streams passing through Ring 2 will operate normally for around 2 hours then after that the Fiber SWs begin to flood their multicast traffic causing the cams on the same switch to drop off the network .
I checked the Configuration of all the SWs on Ring 2 but all are are the same .
What is weird is that I have to set all the streams to unicast to stop the flooding just on Ring 2 (All other rings are not affected ) then after some time if I enabled a video multicast stream on one of the SWs of the Ring it will be streamed properly to the Servers + WorkStations ( All IGMP tables along the way will be filled properly ) then again after 2 hours or so , the flooding will start again suddenly and all IGMP table entries for the SW on Ring2 will be empty . No problem occurs on the other Rings which have more multicast streams .
View 0 Replies
View Related
Jan 15, 2012
Has any come across show ver memory details on 3750G-48PS as below, One of our Catalyst 3750G running software 12.2(44)SE2 shows unexpected DRAM as below:
cisco WS-C3750G-48PS (PowerPC405) processor (revision F0) with 0K/12280K bytes of memory. This would equate to around 11MB memory which does not seem right... Is it a known IOS bug?
View 1 Replies
View Related
Jan 27, 2013
We have several stacks of 3750 switches where this problem is occurring. All of the switches are running IOS version 12.2(50)SE3. (Yes, I know it's old.)
We're seeing inconsistency in how the stack reports members when issuing the following commands:
sow switch
show version
show inventory
Not all members are showing up in the output of the "show version" and "show inventory" commands. For example:
HUNTI-WV-WDAC03#sh switch
H/W Current
Switch# Role Mac Address Priority Version State
----------------------------------------------------------
1 Member 108c.cff2.ea00 15 0 Ready
2 Member 8cb6.4f0a.a600 1 0 Ready
*3 Master 8cb6.4f0a.9c00 1 0 Ready
(all three switches in stack are displayed)(code)
View 1 Replies
View Related
Feb 16, 2013
Region : Poland
Model : TD-W8951ND
Hardware Version : V5
Firmware Version : 5.0.0 Build 120522 Rel.23978
ISP : Orange/TPSA
On my router TD-W8951ND constantly there are the same type errors, while using computer conected to the router:
Code:
2/16/2013 17:24:8> netMakeChannDial: err=-3000 rn_p=80544b08
2/16/2013 17:24:13> Last errorlog repeat 2 Times
[Code].....
View 1 Replies
View Related
Feb 17, 2012
I have the following switch:
#show version
Cisco IOS Software, C3750 Software (C3750-IPSERVICES-M), Version 12.2(52)SE, RELEASE SOFTWARE (fc3)
Copyright (c) 1986-2009 by Cisco Systems, Inc.
Image text-base: 0x01000000, data-base: 0x02C00000
ROM: Bootstrap program is C3750 boot loader
BOOTLDR: C3750 Boot Loader (C3750-HBOOT-M) Version 12.2(44)SE5, RELEASE SOFTWARE (fc1)
[code]...
I have downloaded c3750-ipservicesk9-mz.150-1.SE2.bin and I want to upgrade iOS to this image.
I have a few questions related to this:
1. Is my switch model compatible with this iOS version?
2. Do you recommend the upgrade? Does it bring some notable features?
3. Can I upgrade for free or do I need to buy some license?
4. I also want to upgrade/add the crypto image, can I add crypto for free or some license is required?
5. I have remote access to my switch via the console cable which plugged into machine1. But machine1 is connected to network via the same switch. I am accessing machine1 via SSH, and then the switch via console cable (minicom on CentOS). Is there an upgrade procedure for this kind of situation that also has some fall back (like reboot in X minutes and load the previous image) if the upgrade goes wrong?
View 6 Replies
View Related
Feb 27, 2012
We have two switches WS-C2960S-24TS-L running in stack with running IOS c2960s-universalk9-mz.122-55.SE3.We have connected two checkpoint devices on Gi1/0/24 and Gi2/0/24 with a simple configuration:
interface range GigabitEthernet1/0/24, gi2/0/24
switchport access vlan x
switchport mode access
spanning-tree portfast
On the devices log we get the following message:
%SW_MATM-4-MACFLAP_NOTIF: Host 0000.0000.fe21 in vlan x is flapping between port Gi2/0/24 and port Gi1/0/24
The mac-address 0000.0000.fe21 is not found on any checkpoint interface. "Show mac-address int gi1/0/24 or gi2/0/24" does not show the correct mac-address of the checkpoint interface connected to the port, but instead shows 0000.0000.fe21.Is there a bug in the IOS, something wrong with the switch config or does it have something to do with the checkpoint config?
View 2 Replies
View Related
Jan 2, 2013
getting CPU utilization around 62%
CPU utilization for five seconds: 54%/6%; one minute: 61%; five minutes: 61%
PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process
35 82081 9642 8512 0.31% 0.21% 0.18% 0 Compute load avg
[Code]....
View 1 Replies
View Related
May 9, 2013
I have problem with my cisco switch 2970.
Initializing flashfs...
flashfs[1]: 5 files, 1 directories
flashfs[1]: 0 orphaned files, 0 orphaned directories
flashfs[1]: Total bytes: 15998976
flashfs[1]: Bytes used: 5935616
[Code]...
View 2 Replies
View Related
Jul 24, 2012
I have a got a requirement where a 24 Port Switch should have 4 SFP's and all 4 should be used at a time, So I've chosen " WS-C2960S-24TS-L"
The transeiver should be GLC-LH-SM, so kindly let me no whether I would be able to use all 4 ports at a time or not.
View 2 Replies
View Related
May 1, 2012
how to reset password on WS-C3560G-24TS?
View 1 Replies
View Related
Dec 4, 2011
No date in the TOP-N Interface Errors portlet showing in LMS 4.1, but data for TOP-N Interface Utilization is displayed like expected. The Interface Errors poller show active(without errors) with same Instances as Interface Utilization.
View 1 Replies
View Related
Jan 20, 2013
Inter-VLAN applications are slow and same VLAN it is working fine.(i.e.VLAN to VLAN applications and File transfer response was Slow).Switch Model number: WS-C3750G-24TS-S1U
View 3 Replies
View Related
Jan 3, 2012
I just received three WS-C2960S-24TS-Land three WS-C3560E-48TD-S switches that i entered the Express Setup on as usual. On two of each type of switch i found the default network that is used to facilitate the Express Setup was 10.0.1.1 and the others used an IP range of 10.0.2.1, i realized this is a small negligible at best difference though i need to provide management with an answer as to why there is a difference between the two and can’t find anything online as to why there is a difference or something that proves there should be a difference. All the documentation I find sounding Express Setup notes that the IP range will be 10.0.1.1 not 10.0.2.1
View 3 Replies
View Related
Apr 10, 2012
Is there a way I can downgrade the firmware on a C3750 v2 switch 24TS-S v07 to 12.2(35) SE5. I have added this new switch to an existing stack but the FW is not compatable. I believe the answer is to upgrade the rest but I cannot afford any down time as they are used to run a CCTV securiy network 24/7. I have included details below to assist with my problem. Switch 4 is the one with a version miss match.
LNB-SWI3750-CTR-01#show verCisco IOS Software, C3750 Software (C3750-IPBASE-M), Version 12.2(35)SE5, RELEASE SOFTWARE (fc1)Copyright (c) 1986-2007 by Cisco Systems, Inc.Compiled Thu 19-Jul-07 19:15 by nachenImage text-base: 0x00003000, data-base: 0x01080000
ROM: Bootstrap program is C3750 boot loaderBOOTLDR: C3750 Boot Loader (C3750-HBOOT-M) Version 12.2(25r)SEE4, RELEASE SOFTWARE (fc1)
LNB-SWI3750-CTR-01 uptime is 19 weeks, 3 days, 22 hours, 46 minutesSystem returned to ROM by power-onSystem image file is "flash:c3750-ipbase-mz.122-35.SE5/c3750-ipbase-
[code]....
View 5 Replies
View Related
Jun 28, 2012
I need to configure the C3560-24TS, QoS control by IP or subnet.i tried to study books and videos many times but still feel i am not well known about QOs...
View 1 Replies
View Related
Nov 2, 2011
I have a situation. I am running two-switch 3750-stack and it crashed this morning. IOS version the switches is: "flash:c3750-ipservicesk9-mz.150-1.SE.bin"
SRPRSRGBYA#
Log Buffer (10000 bytes):
3:40.840: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan104, changed state to up
Nov 3 13:13:40.840: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan201, changed state to up
Nov 3 13:13:40.840: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan202, changed state to up
M-1-CRASHED: (SRPRSRGBYA-1)
Nov 3 13:18:13.336: %PLATFORM-1-CRASH(code)
View 3 Replies
View Related
Nov 15, 2012
I am confused about some things regarding the different IOS versions and their compatibility with certain switch hardware. I understand the differences between the IPBASE and IPSERVICES ios but am not quite clear as to how you can tell which ios images will work on which Cisco switch model platforms, other than the fact that some switches are designed only to run the IPBASE images and others have advanced hardware to run the advanced images. For instance, if I have a 3750-24TS-E with an IPBASE ios on it, can I load an IPSERVICES ios that came from say a 3750G-24TS-E1U? whether the ios on one platform can be transferred to another?
View 5 Replies
View Related
Mar 23, 2013
Devices are 3750-24TS Switches, software version is 12.2(55)SE6. how to troubleshoot this issue, I have a pair of ports which are not bundling, no matter what. Is the same behavior with LACP or PAgP. In this outputs I have only the PAgP case.
Output is similar to:
Group Port-channel Protocol Ports
------+-------------+-----------+-----------------------------------------------
12 Po12(SD) PAgP Fa1/0/23(I) Fa1/0/24(I)
Configuration on ports is simple:
SW1:
interface FastEthernet1/0/24
switchport trunk encapsulation dot1q
switchport mode trunk
channel-group 12 mode desirable
[code]....
View 3 Replies
View Related
Dec 19, 2012
We have the following stack configuration:
Switch Ports Model SW Version SW Image------ ----- ----- ---------- ---------- 1 28 WS-C2960S-24TS-L 12.2(55)SE3 C2960S-UNIVERSALK9-M 2 28 WS-C2960S-24TS-L 12.2(55)SE3 C2960S-UNIVERSALK9-M 3 52 WS-C2960S-48TS-L 12.2(55)SE5 C2960S-UNIVERSALK9-M * 4 52 WS-C2960S-48TS-L 12.2(55)SE5 C2960S-UNIVERSALK9-M
View 5 Replies
View Related
May 9, 2012
we want to record voip telephone?Presently im using wireshark on a laptop to test the rspan session
Here is how it's configured
CORE_SWITCH is
Switch Ports Model SW Version SW Image
------ ----- ----- ---------- ----------
* 1 28 WS-C3750G-24TS 12.2(52)SE C3750-IPBASEK9-M
2 52 WS-C3750G-48TS 12.2(52)SE C3750-IPBASEK9-M
[code]....
Ive created the vlan 33 on my core switch and remote SPAN VLANs 133 Core switch is vtp server so i double checked on all switch and vlan 33 and 133 are present When i listen to conversation with wireshark we are only recoding voice of the one who is answering and we don't hear the other person talking?
View 3 Replies
View Related
May 10, 2012
We recently had to rebuild our ACS server. Now when we have an 802.1x authentication failure and look at the RADIUS logs for the specific user, it does not show us the MAC address of the device the user tried to login with. We use this all the time because users have PDAs and other mobile devices that they save their passwords on. Then when they change their domain password on their laptop, they don't change it on their PDA which then tries to authenticate them using the wrong password and eventually locks them out. We need to see the MAC address so we can pinpoint which device is causing the lockout. The report I am generating is when you go to this location: Monitoring & Reports > ... > Reports > Catalog > User > User_Authentication_Summary
View 4 Replies
View Related
Sep 13, 2012
I've noticed in the mornings lately when I get up around 6 am my internet will not work. Not on wireless or on my desktop. I decided I'd log into the router to see if there was a firmware update or anything. I had checked the logs and there are quite a few entries relating to DoS. I googled around and saw that it could be some sort of packet loss and the router is mistaking it for some sort of DoS attack. And that due to it not showing up multiple times every second it likely isn't a DoS attack. Here is a few from the logs:
[code].....
View 4 Replies
View Related
Oct 21, 2012
I ran into a problem a few weeks ago and am still trying to figure out why either the 3560 switch or our Cacti syslog server did not alert us when one of our ports was experiencing heavy CRC and Input errors.
I had upgraded the IOS to 12.2(55)SE6 and rebooted the switch. About a week later, someone was troubleshooting why print jobs were having problems printing to a high speed printer. When I looked at the interface it showed a few thousand CRC and Input errors. I cleared the counters and had them print again and watched as the CRC and Input errors went up. When I did a "show log" there were no error messages. Looking at our Cacti Syslog there were also no errors present for the past 6 months.
We found that the device on the port was set to auto speed and duplex and the switch port was at 100/Full. Once we got them to match the problem was resolved, but we were left wondering why we never got any alerts.
We also have some 3548 and 3550 model switches that Cacti picks up %LINK-4-ERROR for any ports that show CRC and Input errors. I did some research and it appears that the 3560 switches do not have the LINK facility code. I believe it has been replaced with a PHY link code but I'm not sure. We do have some "%PHY-4-EXCESSIVE_ERRORS: Excessive FCS, data, or idle word errors found" but they are all for 3750 switches. I could not find any 3560 that had alerted for that error or the LINK error.
I also tripped port security on the 3560 switch just to make sure that it was reporting correctly to Cacti and that alert did show up.
My question is how do I get a 3560 switch to alert in the logging buffer for CRC/Input/FCS errors? Also, how I can generate CRC and Input errors on purpose for testing? I tried mismatching the speed/duplex/Auto and only got collissions, no CRC or Input errors.
View 2 Replies
View Related