Cisco Switching/Routing :: Stack With WS3750G-24ps And WS-C2960S-24PS
Jun 5, 2012is possible to have WS3750G-24PS in one stack with WS-C2960S-24PS? I want to add two new WS-C2960S-24PS to stack with one WS3750G 24PS.
View 1 Repliesis possible to have WS3750G-24PS in one stack with WS-C2960S-24PS? I want to add two new WS-C2960S-24PS to stack with one WS3750G 24PS.
View 1 RepliesI am not on site and I have not seen a WS-C3750V2-24PS-S. Customer has a stack of 6 x WS-C3750V2-24PS-S and one unit has failed. We do not have a WS-C3750V2-24PS-S spare. Can we replace it with a standard WS-C3750-24PS-S (not V2) switch and be part ofthe stack.
1. Are there any traps gotchas?
2. What about IOS versions - aren't they different for V2 switches
3. Are the stack ports and stack cables same for both WS-C3750V2-24PS-S and WS-C3750-24PS-S
4. What is the main reason for bringing out the V2 switches. What features do they have extra?
I have three new 2960 switches as listed in the title. I configured them as follows:
192.168.1.215 host: whse-c
192.168.1.216 host: whse-b
192.168.1.217 host: whse-a
Switches B and C flow into A before continuing on into the server room switch (distance issues).All three switches are configured for ports 21-24 at 1000 and set as cisco switches. all other ports are undefined as they have a myriad of desktops, printers and non cisco access points flowing into them. side question - should i configure them as access points where applicable even if they are non cisco? I am replacing three netgear switches that currently are in place and have no known issues other than they are old and the fans may fail soon.hooked up .217. was able to get to it from the network. Hooked up 215 and then 216. All the sudden I lost the ability to tap into the switches, any of them. (I think I had done 215 at that point too, before adding 216. I found out later it took the network to its knees as internet was lost, and the MPLS stopped functioning.
I undid the changes and put the netgears back in service and all was right with the world again. At first I thought it was a bad host name as I had used whse-a on switch C in error. I changed that after this issue.Later that day I put 215 in place. checked it from the network and could get to it just fine. Then I put 216 in service. I lost connection to 215. I could no longer get to the internet from my pc and the MPLS went down again. This time I just unhooked 216. 215 is still in place and working on the network at the moment and not causing issues. (btw these switches are not even in my path from my pc to the internet, just on the same network) tomorrow I am going to try 217 again while 215 is still on the network and see if there are any issues adding that swtich. if I can do so, and there are no problems, is this an indication of a faulty switch? what further testing can I do, have I missed something in setup? If this brings the network down again, why cant i add two of these switches to each other/on the same network path (B and C were not even connected to each other yesterday evening when it went down again).
I receive a question from a future customer about this future if its supported on " WS-C2960S-24PS-L":configuring 2 dhcp server on this swith ( 1 dhcp for voice vlan , and 1 for Data Vlan).I did some search , but i didnt find the answer .i have to advice a customer before ordering the switch.
View 2 Replies View RelatedI have WS-C3750-24PS version 12.2(55)SE4. I am configuring PBB VPLS. MY PE/P routers are alcatel 7710/7750
my topology is like that.
CE1<-------> Provider_switch(3750)<-------> PE1 < ----IP/MPLS----> PE2<-------> Provider_switch(3750)<----------->CE2
16 11 11
[Code].....
3560 is running c3560-advipservicesk9-mz.122-40.SE. The SFP (GLC-TX) has been tested in another 3560 and is recognized. Both the gi0/1 and gi 0/2 ports show the type as unknown.
Port Name Status Vlan Duplex Speed TypeGi0/1 notconnect 1 auto auto unknownGi0/2 notconnect 1 auto auto unknown
I am having an issue with VoiP phones giving me an insufficient bandwidth message. I have three remote locations connected to our main building using 2 Mb point to point ethernet solutions through TWC. Each remote location has a Cisco WS-C3560-24PS running IOS C3560-IPBASE-M, version 12.2(25) and have the cable modems plugged into port 1 on them. The remote buildings are labeled 192.168.101.xxx, 192.168.102.xxx, and 192.168.103.xxx. There are 14-16 VoiP phones in each remote building. The main building being in the subnet of 192.168.100.xxx. I have the 3560s connecting to a single port on a 2801 in the main building, all using the subnet of 192.168.253.xxx The phone server sits in our network at 192.168.100.203. I have created the ACLs, class maps, and policy maps on all of the equipment.
For the remote buildings I have the following:
ACL
===========
Extended IP access list VOIP
permit tcp any host 192.168.100.203 dscp ef
permit tcp any host 192.168.100.203 eq 5566
[Code]....
I have put a hub in to capture traffic via Wireshark to see if DSCP flags are being appropriately marked and I do see that all VoiP packets are getting marked with as EF. However, I have been receiving phone calls from people in the remote buildings stating that their phones will cut out, flash Insufficient Bandwidth on the LCD displays and then the call will cut back in. I am wondering if the 2801 is not applying QoS with the rate-limits in mind since it is set to 100 Mb, or is it an issue with trying to take 3 remote locations and bring them down into 1 port on the 2801?
I'm having trouble stacking a new WS-C3750X-24P with existing switches WS-C3750G-24PS ?I can see the license is on the new WS-C3750X-24P:
switch#sho lic
Index 1 Feature: ipservices
Period left: 8 weeks 4 days
License Type: Evaluation
License State: Active, Not in Use, EULA not accepted
License Priority: None
[code].....
I could put on the c3750e-ipbasek9-mz.122-55.SE1 image, but I may need to get the license sorted still, but not sure if that will work or how to add it if i got one.....
Can a C3560-24PS switch with 32 MB flash be loaded with IOS 15? Will it be able to execute the code and function properly?
View 2 Replies View RelatedI can´t configure speed in a giga port on WS-C3560-24PS-S switch(config-if)#speed ? no negotiate Do not negotiate speed
do you know if the port support speed 100??
because I need to connect with 2955C-12 switch in one port: 100BASE-FX (Multimode Fiber) uplinks, this port its only 100mbps?
and the switch C3750G-12S-E can I configure the ports on 100mbps?
Just spoke to the TAC and didn't get the information needed. When configuring ip dhcp snooping database I am adding this to my configuration:ip dhcp snooping database scp://dhcpsec@192.168.1.50/home/dhcpsec/switch1.dhcp.database.txt..I assumed that to do this I would either specify the password on the command line, similar to the way its done when using ftp/http, or that I would need to create a public/private key.I have enabled scp and can manually copy a file from the switch to the linux server. So I believe I have all the aaa commands correct. Cisco WS-C3560G-24PS System image file is "flash:/c3560-ipservicesk9-mz.122-55.SE.bin".
View 3 Replies View RelatedThe default value of DRAM and Flash memory are 128 MB and 16 MB of Cisco Catalyst WS-3750-24PS-E switch .I want to know , wherther the default value may be change upto 256 DRAM and 128 Flash.
View 2 Replies View RelatedI have a WS-C3560G-24PS service as a distribution switch with six (6) WS-C2950T-24 connected to it. In looking at the utilization on the inter connect links no one is running close to a gig speed and this includes the link between this switch and the core. The CPU load (6%) and memory utilization (30%) on the switch do not seem bad so what else does one watch to see if it needs an upgrade?
We are starting tohave discussions about any needed upgrades on the network. I have an ocassional user that complaines about low performance but looking through the network I can find nothing glaring on a consistent basis that says an upgrade is warranted. I am however looking at things such as the above. Utilization on links, CPU, memory, etc.
I've been experimenting with the 'vlan dot1q tag native' command on a switch and it seems as though tagging the native vlan breaks vty access to my access point.With the 'vlan dot1q tag native' commnand applied, I lose management connectivity to the AP with 'no vlan dot1q tag native' applied, connectivity is restored. Why is this? Is it safe to say that one can access the AP via vty lines using ONLY untagged packets?
SWITCH
Model: WS-C3560G-24PS
Code: c3560-advipservicesk9-mz.122-46.SE
--Abbreviated CONF
vlan dot1q tag native
[code]....
We have a Cisco switch in each office and every now and then the port that has the D-Link Wireless AP (DAP-1522) connected to it goes to err-disable state. Actually sometimes even a regular port that has a cisco phone connected may also go to err-disable state (less often). So I have to telnet into the switch and issue shut and no shut command on that interface to get it back to life, then it works for a few days or weeks until it happens again. Any suitable configuraiton for that interface, that would prevent that from happening or a workaround ?
Here's the info:
Model: cisco WS-C3560-24PS and cisco WS-C3560-48PS
Image:c3560-ipbase-mz.122-35.SE5.bin
This is the log from one switch:
31w5d: %PM-4-ERR_DISABLE: psecure-violation error detected on Fa0/2, putting Fa0/2 in err-disable state
31w5d: %PORT_SECURITY-2-PSECURE_VIOLATION: Security violation occurred, caused by MAC address 74e2.f592.f7f2 on port FastEthernet0/2.
31w5d: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/2, changed state to down
And from another, which is almost the same:
5d10h: %PM-4-ERR_DISABLE: psecure-violation error detected on Fa0/3, putting Fa0/3 in err-disable state
5d10h: %PORT_SECURITY-2-PSECURE_VIOLATION: Security violation occurred, caused by MAC address d8a2.5e31.2cf6 on port FastEthernet0/3.
5d10h: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/3, changed state to down
5d10h: %LINK-3-UPDOWN: Interface FastEthernet0/3, changed state to down
Here's the configuration of fe interfaces (they are all alike):
interface FastEthernet0/2
description Voice & Data Combo Port
switchport access vlan 11
switchport mode access
switchport voice vlan 15
[code]....
We have a 2960 stack of 4 WS-C2960S-24PS-L switches.Sometimes, at random, the stack crashes and reboots. I have downloaded the crashinfo file and can see the following error.
View 7 Replies View RelatedI'm trying to configure a stack between two WS-C2960S-48FPS-L but does not working.The switch port is always Down.I tried to change de module and cables.I tried to make a loop in one of two switches and the ports always down.
IOS: 12.2(55)SE5
#show switch stack-ports
Switch # Port 1 Port 2
-------- ------ ------
1 Down Down
We have two switches WS-C2960S-24TS-L running in stack with running IOS c2960s-universalk9-mz.122-55.SE3.We have connected two checkpoint devices on Gi1/0/24 and Gi2/0/24 with a simple configuration:
interface range GigabitEthernet1/0/24, gi2/0/24
switchport access vlan x
switchport mode access
spanning-tree portfast
On the devices log we get the following message:
%SW_MATM-4-MACFLAP_NOTIF: Host 0000.0000.fe21 in vlan x is flapping between port Gi2/0/24 and port Gi1/0/24
The mac-address 0000.0000.fe21 is not found on any checkpoint interface. "Show mac-address int gi1/0/24 or gi2/0/24" does not show the correct mac-address of the checkpoint interface connected to the port, but instead shows 0000.0000.fe21.Is there a bug in the IOS, something wrong with the switch config or does it have something to do with the checkpoint config?
I have a customer with a stack of two switches C2960S-24TS-L that are running 12.2(58)SE2 universal K9, we see that the CPU load increase over time, to 95% and stays there reload solves the problem.the process that akes a lot of CPU is also the SNMP ENGINE, I see that it is running 30 minutes on 95% and then 10 minutes on 35%, this is the only stack were we see this problem. Is there also a SNMP bug in this version ?
View 1 Replies View RelatedI have a Cisco WS-C2960S-48TD-L with 12.2(55)SE2.This is a standalone switch, not in stack, and with no order it reboots itself looking for a new master election. On logging i have nothing, but connected with console cable i see the following after 2 minutes of not showing anything:
Waiting for Stack Master Election...
...
The switch reboots and:
...
*Mar 1 00:00:12.289: Read env variable - LICENSE_BOOT_LEVEL =
[URL]
After searching online i have no seeing nothing about disable the feature of the stack so i configure the priority for the "switch 1" to 15 and configure it the switches 2, 3 and 4 to no provision, although this switches don´t exist:
SW_ACCESS(config)#switch 1 priority 15
Changing the Switch Priority of Switch Number 1 to 15
Do you want to continue?[confirm]
New Priority has been set successfully
[URL]
With this new configuration the switch has rebooted again.Why on a standalone switch the stack is rebooting my system?Is it any feature to disable the stack?
We have the following stack configuration:
Switch Ports Model SW Version SW Image------ ----- ----- ---------- ---------- 1 28 WS-C2960S-24TS-L 12.2(55)SE3 C2960S-UNIVERSALK9-M 2 28 WS-C2960S-24TS-L 12.2(55)SE3 C2960S-UNIVERSALK9-M 3 52 WS-C2960S-48TS-L 12.2(55)SE5 C2960S-UNIVERSALK9-M * 4 52 WS-C2960S-48TS-L 12.2(55)SE5 C2960S-UNIVERSALK9-M
I have a problem with adding a Cisco switch to the NMS (Smarts). When I start a discovery process from the snmp manager (Smarts NMS) it does resolve the ip address into the host name but once the discovery process is completed the device in question is not added in the list of managed devices. Attached is basic configuration.
View 4 Replies View RelatedI am trying to buy a GLC-SX-MM SFP module via Fed Stock, and I keep getting a GLX-SX-MM. What is the difference between these two part numbers? I can't find it on the Cisco Web site and eve a search of Google comes up relatively fruitless! Is the GLX compatible with my 3750G-24PS switch?
View 2 Replies View RelatedI'm configuring AP in Hreap mode. Objective for me is th have a "plug & play" installation method for HREAP. I configure on HREAP AP, Native VLAN set to 1 and the WLAN and Vlan mapping for the current wlan is set to 1 too. WLC version is 7.0.230.0 and AP version is 12.4(23c)JA4
on my cisco switch (WS-C3560-24PS with 12.2(55)SE1), the port configuration is as below:
switchport trunk encapsulation dot1q
switchport trunk native vlan 45
switchport trunk allowed vlan 45,74
switchport mode trunk
no logging event link-status
no logging event power-inline-status
no snmp trap link-status
spanning-tree portfast trunk
spanning-tree bpduguard enable
AP receives a DHCP IP in Vlan 45 and users connected in vlan 45 too. I would like to undestand why the AP is working properly because normally vlan 1 is not configured as allowed vlan on my switch and the native vlan is dedicated only to untagged ethernet packet.
I try to configure in both Clean Access Manager and Switch 3560E-24Ps on SNMP Version 2 protocol but I can't make it working together (For CAM and Switch 3560G-48Ps I can do that). [code]
View 3 Replies View RelatedIs there a stacking cable that is "bent"?Im using this cable:"CAB-STACK-50CM", "Cisco StackWise 50CM Stacking Cable".But it takes up to much room in the back of the switch, is there such a thing as "bent" stacking cable.
View 1 Replies View RelatedI have 3 switches in my 3750 X stack. I am getting the following error in the logs: %PLATFORM_STACKPOWER-4-PRIO_CONFLICT: Switch 1's power stack has conflicting power priorities. Not sure what I should do next. Below is my Stack-power configuration:
Power stack name: Powerstack-1 Stack mode: Power sharing Stack topology: Ring Switch 1: Power budget: 735 Low port priority value: 20 High port priority value: 10 Switch priority value: 2 Port 1 status: Connected Port 2 status: Connected Neighbor on port 1: c464.1308.7900 Neighbor on port 2: e8b7.4827.e680
Switch 3: Power budget: 729 Low port priority value: 22 High port priority value: 13 Switch priority value: 4 Port 1 status: Connected Port 2 status: Connected Neighbor on port 1: 2894.0fd9.9f00 Neighbor on port 2: 2894.0fd8.e200
Switch 2: Power budget: 690 Low port priority value: 21 High port priority value: 12 Switch priority value: 3 Port 1 status: Connected Port 2 status: Connected Neighbor on port 1: 2894.0fd8.e200 Neighbor on port 2: c464.1308.7900
Each switch has its own 715W power supply in it and all check out OK.
A site that i am responsible for has the following equipment installed:
2 x 3750G Switches configured as a stack using Stackwise - Collapsed Core/Distribution Layer
5 x 2960G Switches as Access Layer switches
WAN connections into the Core/Distribution Layer are all Gigabit Ethernet over Fibre.This is a dedicated CCTV Network with 50 Cameras all streaming video into the Core (decoders connected to access switches)Each 2960G has 2 links to the Core/Distribution 3750G Switches, 1 to each switch - Gigabit.I'm running rapid-pvst on all switches, so spanning tree is blocking one of the ports and effectively halving the 2 gig bandwidth. Next year our customer is going to add in a further 50 - 60 cameras.After monitoring the current loading on the ports in use, we have suggested to the customer that the 2 connections to each should be Ether-channeled together. [code]
First interface takes commands no problem, keep getting the message that etherchannel cannot be configured across different switches in a stack when i try to put the second interface commands on.
I just upgraded several of my C2960S-48FPD-L from 12.2(55)SE to 12.2(58)SE and now almost every time I try to SSH to it the switch reboots and gives me these trace backs ...
07:58:52 CST Thu Apr 14 2011: Unexpected exception to CPU vector 200, PC = 1EADA28
-Trace back= 0x1EADA28z 0x1CDC324z 0x1EA5520z 0x1CDC35Cz 0x1CDD0E0z 0x1CDF0C4z 0x1CE06CCz 0x1CE07F8z 0x1D67348z 0x1D611BCz
Writing crash info to flash:/crashinfo_ext/crashinfo_ext_3
07:58:56 CST Thu Apr 14 2011: Unexpected exception to CPU vector 1100, PC = 121BB98
-Trace back= 0x121BB98z 0x12250FCz 0xFA7540z 0xA807B8z 0xA75DF4z 0xA78080z 0x94B708z 0x9717C0z 0x918DD8z 0x936520z 0x9344BCz 0x9345FCz 0x93484Cz 0x1D67348z 0x1D611BCz
=== Flushing messages (07:58:56 CST Thu Apr 14 2011) ===
Buffered messages: (last 4096 bytes only)
0x00000005 R6 = 0x01224F44 R7 = 0x02A23C6C
000089: *Feb 28 18:03:13.577 CST: %PLATFORM-1-CRASHED: R8 = 0x00000080 R9 = 0x00000000 R10 = 0x00000000 R11 = 0x00000071
000090: *Feb 28 18:03:13.577 CST: %PLATFORM-1-CRASHED: R12 = 0x00034855 R13 = 0x00000280 R14 = 0x01CE0778 R15 = 0x00000000
000091: *Feb 28 18:03:13.577 CST: %PLATFORM-1-CRASHED: R16 = 0x00000000 R17 = 0x00000000 R18 = 0x00000000 R19 = 0x00000000
[ code]....
I am looking for a reasonable switch but it has do do inter-VLAN Routing. I know I could go with a 3560/3750 with IP Services but I am also thinking the 2960S with IP Base IOS might do?
I have looked up the IP Base IOS and it does list IP Routing but how to actually configure inter-VLAN Routing on a 2960S with IP Base?
I have been trying to enable L3 intervlan routing on C2960S Switch with ip routing command and that was the output from the Switch: [code]
View 6 Replies View RelatedIs there a CLI-command to see the serial number of the flexstack module installed in a C2960S.
View 13 Replies View RelatedWe have several of these WS-C2960S-24PS-L running 12.2(55)SE5 C2960S-universalK9-M and need to upgrade to a better.IOS since we have a sitution where CPU would get to 100% but we have only a few ports connected.Also we have several of WS-C3750-48P running 12.2(55) SE6 C3750-IPBASEK9-M.
View 3 Replies View Related