Cisco Infrastructure :: Is GLX Compatible With 3750G-24PS Switch
May 23, 2011
I am trying to buy a GLC-SX-MM SFP module via Fed Stock, and I keep getting a GLX-SX-MM. What is the difference between these two part numbers? I can't find it on the Cisco Web site and eve a search of Google comes up relatively fruitless! Is the GLX compatible with my 3750G-24PS switch?
I am not on site and I have not seen a WS-C3750V2-24PS-S. Customer has a stack of 6 x WS-C3750V2-24PS-S and one unit has failed. We do not have a WS-C3750V2-24PS-S spare. Can we replace it with a standard WS-C3750-24PS-S (not V2) switch and be part ofthe stack.
1. Are there any traps gotchas? 2. What about IOS versions - aren't they different for V2 switches 3. Are the stack ports and stack cables same for both WS-C3750V2-24PS-S and WS-C3750-24PS-S 4. What is the main reason for bringing out the V2 switches. What features do they have extra?
I want to know if Cisco Router 1905 is compatible for connecting USB Internet dongle for VPN Tunnel configuration at USB port of same router. If Yes then how to open that port for config. Find the show tech logs of Cisco Router 1905 attached.
I understand that the NM-1FE Fastethernet modules are not compatible with Cisco 2600 series routers, just the Ethernet 1-E module. With that being said, are there ANY modules supported by the 2600, 2621 or 2621XM series routers that have fastethernet port(s) outside of the pricey NM-16ESW module? I don't need a 16 port module!
Just want to ask if 4-port serial HWIC-4T is compatible for the Cisco 2801?We need additional HWIC for Fast Ethernet but the problem is we don't have already slot for it.We already have two HWIC-2T 2-port serial which is inserted at slot 1 and slot 3. We're planning to buy 4-port HWIC-4T so we can use the slot 3 for HWIC Fast Ethernet.if it's possible to have the 4-port serial HWIC-4T be inserted to Cisco 2801.
I have a WS-C3560G-24PS service as a distribution switch with six (6) WS-C2950T-24 connected to it. In looking at the utilization on the inter connect links no one is running close to a gig speed and this includes the link between this switch and the core. The CPU load (6%) and memory utilization (30%) on the switch do not seem bad so what else does one watch to see if it needs an upgrade?
We are starting tohave discussions about any needed upgrades on the network. I have an ocassional user that complaines about low performance but looking through the network I can find nothing glaring on a consistent basis that says an upgrade is warranted. I am however looking at things such as the above. Utilization on links, CPU, memory, etc.
I try to configure in both Clean Access Manager and Switch 3560E-24Ps on SNMP Version 2 protocol but I can't make it working together (For CAM and Switch 3560G-48Ps I can do that). [code]
I'm having issues with SSH on my 3750G-12S. I'm not able to SSH to another switch when VRFs are configured.I've tried ip ssh source-interface, ssh -vrf doesn't exsist and I've upgraded the IOS to the latest version.
I'm trying to set up QoS between a 2811 router and a 3750g switch. I'm currently using the 3750 as the router for one side, having the interface connecting to the router as a routed interface.
I have this config on the router side:
class-map match-any IPTel-Traffic-CL match ip dscp ef match ip precedence 5
I am having a switch 3750G (WS-C3750G-24TS-S) running a software version (c3750-ipservicesk9-mz.122-55.SE6.bin) and using the PBR with IP SLA.While, i am applying it on interface, it says not supported....
route-map TO-CAS-E0 permit 10 match ip address 125 set ip next-hop verify-availability 10.116.199.200 10 track 100 (if i change this command to set ip next-hop 10.116.199.200, it works) ! WAN-L3-3750SW01(config-route-map)#interface GigabitEthernet1/0/11
I have one switch 3750G12S I joined the company new, I found that they want to replace it with Alcatel stack switches. I didnt configure this Cisco switch before. how to configure it. I have 4 other new cisco switches in the topology which is not created yet. the 4 switches are all 2960.
have one 3750G stack with 4 switches and this stack is presenting the follow log message:
%PLATFORM_UCAST-4-PREFIX: One or more, more specific prefixes could not be programmed into TCAM and are being covered by a less specific prefix, and the packets may be software forwarded.
In this stack we are using the layer 3 with OSPF routing, and the current sdm prefer is default:
switch-01-3750#sh sdm prefer The current template is "desktop default" template. The selected template optimizes the resources in the switch to support this level of features for 8 routed interfaces and 1024 VLANs.(code)
i have confussion in my layout network design if this device working properly if i put this to my netwok. i want to config my router with 3 different subnet and in switch area i want to create 3 vlans with different subnet on each. may question is, is this posible for this kind of router to route my vlan network? here is the IP address i want to add in IP Table.
I'm due to replace a stack of 2 x 3750 switches very soon with 2 x 3750Gs. These 2 current switches are the VTP server for a small domain. I have put the config on the new switches switches and I made it a server and used the same VTP domain and password etc and got the VLAN info ported over.Now I did this a while back and noticed the switches are in transparent mode with a revision number of 0, I need to set this back to server and swap the switches out but the revision will be lower than the client switches (around rev 200), what do I need to do?
I am having an issue bypassing a switch 3750G series. How i can bypass the old configuration in the switch.i have tried the CTRL+BREAK at startup but it wont work.
I am looking few information on IOS up-gradation for the switch WS-C3750G-48TS-S . I loaded new Image on the flash and current flash and sh boot as below
1) I would like to set boot sytem parameter for the new IOS and secondary old IOS as well is below command works??? if IOS not coming up with new one 12.2.58 is it boots with old 12.2-35 ?
boot system flash:c3750-ipservicesk9-mz.122-58.SE2.bin;flash:c3750-ipbase-mz.122-35.SE5
2) If I set only boot system flash:c3750-ipservicesk9-mz.122-58 , if new image corrput swicth will check valid image and boot up with old image ?
3) If switch went to room1 switch mode and still I have valild running IOS c3750-ipservicesk9-mz.122-37.SE.bin at flash memory, how to restore with old image
Has any come across show ver memory details on 3750G-48PS as below, One of our Catalyst 3750G running software 12.2(44)SE2 shows unexpected DRAM as below:
cisco WS-C3750G-48PS (PowerPC405) processor (revision F0) with 0K/12280K bytes of memory. This would equate to around 11MB memory which does not seem right... Is it a known IOS bug?
I am a very basic user on the Cisco Switch programming. I was given a Cisco 3750G-48 to tinker with in my home office. I was wondering if someone could lead me to some good sources of information to program and configure this switch? I am wanting to create a GB network in the house with the computers that I have and the storage arrays.
The two stacked Cisco 3750G Access switches on a particular floor in my coy just lost connectivity to the distribution Switch this morning. This meant that all Users connected to it couldnt connect to the Internet nor access local network resources.I couldn't ping the Switch IP, I couldn't also access the Switch via Console port. Each time I tried to gain access via the console port, I keep getting "Authentication Failed" message.What should I do next? How do I gain access to the Switch?
I am about rip and replace my current 3750G stack with a 3750X stack. I have trunked over vlan and vtp info and implemented a config so it should be ready to go other then moving cables onto it. However one thing I want to correct with our current setup is that the root bridge on our vlans including vlan 1 is on a separate set of switches that we control, however I would like this new stack to be the root bridge for all of our vlans. It will be the central set of switches that all other switches trunk into. I have pre-set higher spanning-tree priorities for each vlan on the new stack so I expect as I move lines into it that the tree will be re-calculated with it as the root bridge. I've ensured that there are no root guards on any of the other switches trunks and priorities are all at default levels for each vlan. Should I enforce root guard on the trunk interfaces of the new master stack? Most of the trunks are port-channels to the other switches - do I need to set root guard on the Port channel interface or on the individual ports that make up the Port channel? On both? Any other recommendations in regards to implementing spanning-tree with the new stack? I know using port channels eliminates a lot of potential for loops but not every trunk is and I'd still like to have spanning-tree on.
I wan to migrate from a router 2800 to L3 switch 3750G , the thing is that we have several vlans and we use a router sometimes with each interface configure with correspoinding vlan subnet ip to route traffic between vlans there is no static or dynamic routing only directly connected interfaces on router routing traffic to each other ?How would i configure a L3 switch interface for simillar functionality , below is my current router configuration
! ip domain name yourdomain.com multilink bundle-name authenticated ! vtp mode transparent
I try to connect two switch Catalyst 3750G without success.switch1 (192.168.2.10 vlan 2) <=> (192.168.2.11 vlan2) switch2.I use this configuration for swich1 [code]
I am cascading one new switch 3750G (int Gi1/0/1) with an existing 3750G (int fa1/0/26) switch.. But the interface fa1/0/26 goes in err-disable state even after NO SH.. also i have diable Spanning treebpdu guard and disable spanning tree portfast. But still the issue is not resolved.
I currently have Cisco 3750G which is currently live and active and fully populated and only have remote access.
I have an additional same switch which I would like to stack. My initial plans were to have 2 GIbit etherchannels, but I came across the option to Stacks both switch with each other.
When I do a show switch on the live switch its set as a Member: [code]
I would like to add the new switch to the stack without losing the config for the switch which is live. I understand that the highest priority of the switches becomes the Master but as the live switch is Priority 1, would chancing this affect the switches config, or would it lose connection at all?
Also when I plug in the new switch and it reboot how do I ensure it becomes the slave without rebooting the live switch?The cables on the switch do they have to go to port1 on the live switch and port 1 on the new switch or can they be port 1 and port 2?