Cisco Switching/Routing :: 3750G / (int Fa1/0/26) Connected To Switch / Goes In Err-disable State
Mar 30, 2013
I am cascading one new switch 3750G (int Gi1/0/1) with an existing 3750G (int fa1/0/26) switch.. But the interface fa1/0/26 goes in err-disable state even after NO SH.. also i have diable Spanning treebpdu guard and disable spanning tree portfast. But still the issue is not resolved.
I am testing 2960 24 S with storm-control and Errdisable Port timer interval 60s , connected HUB on fa0/17 to make traffic / loop.After Strom Control detection the interface goes down thats ok after 60s they will try to recover the interface and going up although the loop is still there.For my understanding if the interface detect still a loop on that interface they will disable the port again for 60s and will check again. [code]
We have a number of 3750 stacks used as access layer switches connecting Siemens VOIP phones and then a PC that connects to the phone.
For example if I plug PC A to the phone that connects to port 13 I pick up an IP addressand all works as predicted now if I plug in PC A to any other VOIP phone that connect to another port on the same switch it goes in error disable state ITs like the switch is holding my PC mac address and locks it down with the port which in my case is Gi2/0/13.
I have a Catalyst 2950G when I activate the switchport port-security, but I want to empty the black list of mac address because every time I connect a device, the port is automatically désacative, here is the port configuration:
After a power problem at our data centre we find Module 11 of our Cisco 6513 Core Switch in PWR Down state.Show Module 11 returns: Status: PWRDownShow Power Status Module 11 returns: OperStatus Off (Module Reset due to an exception or user request).The command: Power enable Module 11 was issued and returned the following: %PM_SCP-SP-1-LCP_FW_ERR: System resetting module 11 to recover from error: Linecard received system exception. Errcode = 2509000001.%OIR-SP-3-PWRCYCLE: Card in module 11 is being powercycled Öff (Module reset due to exception or user request%C6KPWR-SP-4-DISABLED: Power to module in slot 11 set off (Module Reset due to exception or user request),We have restarted the switch twice. The module is currently not passing traffic causing downtime to services.
Recently on two switches, both being same cisco WS-C3750E-24PD, running with same IOS c3750e-universalk9-mz.122-58.SE2.bin got noticed that the license state of one switch is showing incorrectly as shown below [code] I will not be able to execute any changes/modifications on switch as of now.
I have configured a SVI in my 4500 ( Sup 7-E 10GE,,,,,,and,,,,,cat4500e-universalk9.SPA.03.02.00.SG.150-2.SG.bin) switch and it is showing Down Down, because there were no active switch port in the vlan, I added one switch port to this vlan but this port also in the down state, so i added the SWITCH PORT AUTO STATE EXCLUDE command under this port, even after this also the SVI never came up, So i added one systen to the port so both the switch port and the SVI came up...So why SWITCH PORT AUTO STATE EXCLUDE command have no effect in this model of the switch..
I am having a switch 3750G (WS-C3750G-24TS-S) running a software version (c3750-ipservicesk9-mz.122-55.SE6.bin) and using the PBR with IP SLA.While, i am applying it on interface, it says not supported....
route-map TO-CAS-E0 permit 10 match ip address 125 set ip next-hop verify-availability 10.116.199.200 10 track 100 (if i change this command to set ip next-hop 10.116.199.200, it works) ! WAN-L3-3750SW01(config-route-map)#interface GigabitEthernet1/0/11
I have one switch 3750G12S I joined the company new, I found that they want to replace it with Alcatel stack switches. I didnt configure this Cisco switch before. how to configure it. I have 4 other new cisco switches in the topology which is not created yet. the 4 switches are all 2960.
have one 3750G stack with 4 switches and this stack is presenting the follow log message:
%PLATFORM_UCAST-4-PREFIX: One or more, more specific prefixes could not be programmed into TCAM and are being covered by a less specific prefix, and the packets may be software forwarded.
In this stack we are using the layer 3 with OSPF routing, and the current sdm prefer is default:
switch-01-3750#sh sdm prefer The current template is "desktop default" template. The selected template optimizes the resources in the switch to support this level of features for 8 routed interfaces and 1024 VLANs.(code)
I'm due to replace a stack of 2 x 3750 switches very soon with 2 x 3750Gs. These 2 current switches are the VTP server for a small domain. I have put the config on the new switches switches and I made it a server and used the same VTP domain and password etc and got the VLAN info ported over.Now I did this a while back and noticed the switches are in transparent mode with a revision number of 0, I need to set this back to server and swap the switches out but the revision will be lower than the client switches (around rev 200), what do I need to do?
I am having an issue bypassing a switch 3750G series. How i can bypass the old configuration in the switch.i have tried the CTRL+BREAK at startup but it wont work.
I am looking few information on IOS up-gradation for the switch WS-C3750G-48TS-S . I loaded new Image on the flash and current flash and sh boot as below
1) I would like to set boot sytem parameter for the new IOS and secondary old IOS as well is below command works??? if IOS not coming up with new one 12.2.58 is it boots with old 12.2-35 ?
boot system flash:c3750-ipservicesk9-mz.122-58.SE2.bin;flash:c3750-ipbase-mz.122-35.SE5
2) If I set only boot system flash:c3750-ipservicesk9-mz.122-58 , if new image corrput swicth will check valid image and boot up with old image ?
3) If switch went to room1 switch mode and still I have valild running IOS c3750-ipservicesk9-mz.122-37.SE.bin at flash memory, how to restore with old image
The two stacked Cisco 3750G Access switches on a particular floor in my coy just lost connectivity to the distribution Switch this morning. This meant that all Users connected to it couldnt connect to the Internet nor access local network resources.I couldn't ping the Switch IP, I couldn't also access the Switch via Console port. Each time I tried to gain access via the console port, I keep getting "Authentication Failed" message.What should I do next? How do I gain access to the Switch?
I am about rip and replace my current 3750G stack with a 3750X stack. I have trunked over vlan and vtp info and implemented a config so it should be ready to go other then moving cables onto it. However one thing I want to correct with our current setup is that the root bridge on our vlans including vlan 1 is on a separate set of switches that we control, however I would like this new stack to be the root bridge for all of our vlans. It will be the central set of switches that all other switches trunk into. I have pre-set higher spanning-tree priorities for each vlan on the new stack so I expect as I move lines into it that the tree will be re-calculated with it as the root bridge. I've ensured that there are no root guards on any of the other switches trunks and priorities are all at default levels for each vlan. Should I enforce root guard on the trunk interfaces of the new master stack? Most of the trunks are port-channels to the other switches - do I need to set root guard on the Port channel interface or on the individual ports that make up the Port channel? On both? Any other recommendations in regards to implementing spanning-tree with the new stack? I know using port channels eliminates a lot of potential for loops but not every trunk is and I'd still like to have spanning-tree on.
I wan to migrate from a router 2800 to L3 switch 3750G , the thing is that we have several vlans and we use a router sometimes with each interface configure with correspoinding vlan subnet ip to route traffic between vlans there is no static or dynamic routing only directly connected interfaces on router routing traffic to each other ?How would i configure a L3 switch interface for simillar functionality , below is my current router configuration
! ip domain name yourdomain.com multilink bundle-name authenticated ! vtp mode transparent
I try to connect two switch Catalyst 3750G without success.switch1 (192.168.2.10 vlan 2) <=> (192.168.2.11 vlan2) switch2.I use this configuration for swich1 [code]
I currently have Cisco 3750G which is currently live and active and fully populated and only have remote access.
I have an additional same switch which I would like to stack. My initial plans were to have 2 GIbit etherchannels, but I came across the option to Stacks both switch with each other.
When I do a show switch on the live switch its set as a Member: [code]
I would like to add the new switch to the stack without losing the config for the switch which is live. I understand that the highest priority of the switches becomes the Master but as the live switch is Priority 1, would chancing this affect the switches config, or would it lose connection at all?
Also when I plug in the new switch and it reboot how do I ensure it becomes the slave without rebooting the live switch?The cables on the switch do they have to go to port1 on the live switch and port 1 on the new switch or can they be port 1 and port 2?
Has any come across show ver memory details on 3750G-48PS as below, One of our Catalyst 3750G running software 12.2(44)SE2 shows unexpected DRAM as below:
cisco WS-C3750G-48PS (PowerPC405) processor (revision F0) with 0K/12280K bytes of memory. This would equate to around 11MB memory which does not seem right... Is it a known IOS bug?
In my ongoing project i need to monitor cisco 3750-X port status (uplink/downlink) i.e. whenever there is some problem at a specific port. I need to monitor it through an OPC server and right now what i am doing is as follows: i am using Kepserver and i have added SNMP driver in it for that purpose i am not a networking expert but what i have learnt till now is that SNMP agent (that resides in switch) delivers the status of MIBs to SNMP manager ( which in my case is kepserver (opc server)) for the above purpose i am adding IF-MIB to monitor OID 1.3.6.1.2.1.2.2.1.8 (which shows port statuses) but when i add that in OPC server then it indicated that this OID is not available in the Switch ( it might be disabled) so i need to ask if there is any way to enable OID's in a switch,
I have a Cisco 2960G switch and one of the ports was configured with srr-queue bandwidth limit 90 - I need to remove this bandwidth limiting from this interface. [code]
Currently it seems as our 3550's doesn't send traps when bpdu-guard sets a port in err-disable state. Or DFM doesnt recognize it.Is there a way to get a DFM alert when a 3550-port gets into err-disable state?
We have a 3750X VTP Server and the rest of the switches are clients.
Due to cabling issues, we have a switch (Switch F) that we can't connect directly to the 3750X so we have it connected through another switch. Everything is set to VTP client with the correct domain and password but this not-directly-connected switch isn't receiving any VTP VLANs.
Anything I need to do on Switch D so that Switch F can receive the VTP updates?
We are using Cisco Router 1841 and users reporting issue related to VoIP. After investigation, seeing input errors on Router LAN interface, but there is no error on connected switch interface. [code]
I would like to request assistance from all the gurus here for an issue i have with a Cisco 7513MX PSU. There probably arent many people who are aware of 7500 chassis as they are quite old.Isse: PSU 1 failed in chassis and we tried to replace it. Once replaced, we are getting the following output for it:
1#sh env all Arbiter type 2, backplane type 7513MX (id 2) Power supply #1 is TBD (id 0), Power supply #2 is 1200W AC (id 1)
We have been researching on the internet for answers but unfortunately due to the age of this model, there is very limited information available. We did find information which suggested to have BOTH PSU 1 & 2 with same revision. Right now the chassis is running only on PS2, we dont want to take down the chassis just to confirm the revision number on the PSU and there is no way to see that on the CLI. What we can do is get another pair of same revision PSUs, insert PSU1 first THEN take out PSU2 and then insert the same revision as PS1 in PSU2 slot but the moment we insert PSU1 in we get that TBD state which is not normal status and raises our doubts about putting the same revision PSUs with the method above, there is a chance that after we insert PSU1 in, the moment we take out PSU2, the chassis might not run on PSU1 due to its abnormal state.
In my customer having 3750 switch and they have simply assign IP address for vlan and enable telnet in switch and other things are same as default switch.In this switch they have connected 8 cisco layer 2 switches(6 managed and 2 unmanged switch) and approximately 5 servers connected in this switch.In a particular interval,users accessing File server are connected to 3750 switch become hanged for few min.This happen for some particular interval.users accessing this server becomes entirely hanged for few min,then i have configured port monitor cmd and i have installed one wildshark tool to host connected directly to that switch.