Dec 7, 2011I am facing switch reboot issue when power of switch restore from RPS to AC.
View 1 RepliesI am facing switch reboot issue when power of switch restore from RPS to AC.
View 1 RepliesI am having a switch 3750G (WS-C3750G-24TS-S) running a software version (c3750-ipservicesk9-mz.122-55.SE6.bin) and using the PBR with IP SLA.While, i am applying it on interface, it says not supported....
route-map TO-CAS-E0 permit 10
match ip address 125
set ip next-hop verify-availability 10.116.199.200 10 track 100 (if i change this command to set ip next-hop 10.116.199.200, it works)
!
WAN-L3-3750SW01(config-route-map)#interface GigabitEthernet1/0/11
[code].....
I have one switch 3750G12S I joined the company new, I found that they want to replace it with Alcatel stack switches. I didnt configure this Cisco switch before. how to configure it. I have 4 other new cisco switches in the topology which is not created yet. the 4 switches are all 2960.
View 17 Replies View Relatedhave one 3750G stack with 4 switches and this stack is presenting the follow log message:
%PLATFORM_UCAST-4-PREFIX: One or more, more specific prefixes could not be programmed into TCAM and are being covered by a less specific prefix, and the packets may be software forwarded.
In this stack we are using the layer 3 with OSPF routing, and the current sdm prefer is default:
switch-01-3750#sh sdm prefer
The current template is "desktop default" template.
The selected template optimizes the resources in
the switch to support this level of features for
8 routed interfaces and 1024 VLANs.(code)
I have two 3750G switches that are in a stack, and I am seeing these errors in the log:
002258: Feb 4 17:06:06.355 UTC: %PM-3-INTERNALERROR: Port Manager Internal Software Error (vlanid >=0 && vlanid < PM_MAX_VLANS: ../switch/pm/pm_vlan.c: 1279: pm_vlan_get_vlan_data) (CBAC01-3750-2)
-Traceback= 190F078 19729A0 1972A64 1963764 110BC24 195F2F8 110BB9C 196D2C8 195ECD4 110BC24 19658B0 110BB9C 196D1D8 194C2B8 195D24C 110BC24 (CBAC01-3750-2)
002259: Feb 4 17:06:06.355 UTC: %BIT-4-OUTOFRANGE: bit 4096 is not in the expected range of 0 to 4095 (CBAC01-3750-2)
-Traceback= 10273BC 1027478 1972B50 1963764 110BC24 195F2F8 110BB9C 196D2C8 195ECD4 110BC24 19658B0 110BB9C 196D1D8 194C2B8 195D24C 110BC24 (CBAC01-3750-2)
002260: Feb 4 17:06:06.355 UTC: %PM-3-INTERNALERROR: Port Manager Internal Software Error (vlan > 0 && vlan < PM_MAX_VLANS: ../switch/pm/pm_vlan.c: 773: pm_vlan_set_portlist) (CBAC01-3750-2)
[code]....
I am in the process of setting up an interop lab for some engineers. The enviornment will consist of some 3750's, H3C's and ProCurves. My concern is that the end user will have Priv-Exec access for CLI usage on the 3750's and they can change the "en" password (I hope they don't but it has happened).Is there a way I can "break in" during the boot process to reset the password? The reason I am doing it this way is because I have an Altiris server with rebuild automation scripts in xpect and I would like to automate the process so I do not have to use a manual factory default reset.
View 5 Replies View RelatedI was in the process of recovering a password on a nexus 5548 swith when it finally gets in to the boot mode.I think i lost all my bootloader code.How do i get it back on the switch
loader> load n5000-uk9.5.0.3.N2.1.bin
Error 27: Unrecognized command
how to restore my IOS on this device
I'm due to replace a stack of 2 x 3750 switches very soon with 2 x 3750Gs. These 2 current switches are the VTP server for a small domain. I have put the config on the new switches switches and I made it a server and used the same VTP domain and password etc and got the VLAN info ported over.Now I did this a while back and noticed the switches are in transparent mode with a revision number of 0, I need to set this back to server and swap the switches out but the revision will be lower than the client switches (around rev 200), what do I need to do?
View 7 Replies View RelatedI am having an issue bypassing a switch 3750G series. How i can bypass the old configuration in the switch.i have tried the CTRL+BREAK at startup but it wont work.
View 2 Replies View Relatedif we can stack the 3750G switch with a 3750X switch ?
View 7 Replies View RelatedI am looking few information on IOS up-gradation for the switch WS-C3750G-48TS-S . I loaded new Image on the flash and current flash and sh boot as below
Switch#sh flash
Directory of flash:/
2 -rwx 8859636 Mar 1 1993 00:08:14 +00:00 c3750-ipservicesk9-mz.122-37.SE.bin
3 -rwx 556 Mar 1 1993 00:02:38 +00:00 vlan.dat
4 drwx 64 Jan 9 2012 03:17:56 +00:00 crashinfo_ext
5 -rwx 5768 Apr 24 2013 04:25:28 +00:00 private-config.text
[code]...
1) I would like to set boot sytem parameter for the new IOS and secondary old IOS as well is below command works??? if IOS not coming up with new one 12.2.58 is it boots with old 12.2-35 ?
boot system flash:c3750-ipservicesk9-mz.122-58.SE2.bin;flash:c3750-ipbase-mz.122-35.SE5
2) If I set only boot system flash:c3750-ipservicesk9-mz.122-58 , if new image corrput swicth will check valid image and boot up with old image ?
3) If switch went to room1 switch mode and still I have valild running IOS c3750-ipservicesk9-mz.122-37.SE.bin at flash memory, how to restore with old image
The two stacked Cisco 3750G Access switches on a particular floor in my coy just lost connectivity to the distribution Switch this morning. This meant that all Users connected to it couldnt connect to the Internet nor access local network resources.I couldn't ping the Switch IP, I couldn't also access the Switch via Console port. Each time I tried to gain access via the console port, I keep getting "Authentication Failed" message.What should I do next? How do I gain access to the Switch?
View 1 Replies View Relatedi am not able to add new 3750G switch into existing domain even after the domain name is correct and unable to authenticate with tacacs.
View 5 Replies View RelatedI am about rip and replace my current 3750G stack with a 3750X stack. I have trunked over vlan and vtp info and implemented a config so it should be ready to go other then moving cables onto it. However one thing I want to correct with our current setup is that the root bridge on our vlans including vlan 1 is on a separate set of switches that we control, however I would like this new stack to be the root bridge for all of our vlans. It will be the central set of switches that all other switches trunk into. I have pre-set higher spanning-tree priorities for each vlan on the new stack so I expect as I move lines into it that the tree will be re-calculated with it as the root bridge. I've ensured that there are no root guards on any of the other switches trunks and priorities are all at default levels for each vlan. Should I enforce root guard on the trunk interfaces of the new master stack? Most of the trunks are port-channels to the other switches - do I need to set root guard on the Port channel interface or on the individual ports that make up the Port channel? On both? Any other recommendations in regards to implementing spanning-tree with the new stack? I know using port channels eliminates a lot of potential for loops but not every trunk is and I'd still like to have spanning-tree on.
View 1 Replies View RelatedI wan to migrate from a router 2800 to L3 switch 3750G , the thing is that we have several vlans and we use a router sometimes with each interface configure with correspoinding vlan subnet ip to route traffic between vlans there is no static or dynamic routing only directly connected interfaces on router routing traffic to each other ?How would i configure a L3 switch interface for simillar functionality , below is my current router configuration
!
ip domain name yourdomain.com
multilink bundle-name authenticated
!
vtp mode transparent
[code]...
Can we stack a 3750G-12S-S switch with a 3750-E-24TD-S switch?
View 4 Replies View RelatedI try to connect two switch Catalyst 3750G without success.switch1 (192.168.2.10 vlan 2) <=> (192.168.2.11 vlan2) switch2.I use this configuration for swich1 [code]
View 23 Replies View RelatedI am cascading one new switch 3750G (int Gi1/0/1) with an existing 3750G (int fa1/0/26) switch.. But the interface fa1/0/26 goes in err-disable state even after NO SH.. also i have diable Spanning treebpdu guard and disable spanning tree portfast. But still the issue is not resolved.
View 6 Replies View Relatedis it possible, to use a Catalyst Switch (in my case a 3560E) as a source for a console session to another Catalyst? In principle to use it as a console terminal server.
View 1 Replies View Relatedi have a stack of 3750x, with minimal configuration. there are two vlans, and two vlan interfaces with IP addresses. when i ping out from this switch to another host, it picks vlan1's ip address as the source automatically. i tested this by doing two pings with extended options using each vlan's interface as the source, and got different results. how the switch decided to use the first vlan's ip address as a source.
View 11 Replies View RelatedI currently have Cisco 3750G which is currently live and active and fully populated and only have remote access.
I have an additional same switch which I would like to stack. My initial plans were to have 2 GIbit etherchannels, but I came across the option to Stacks both switch with each other.
When I do a show switch on the live switch its set as a Member: [code]
I would like to add the new switch to the stack without losing the config for the switch which is live. I understand that the highest priority of the switches becomes the Master but as the live switch is Priority 1, would chancing this affect the switches config, or would it lose connection at all?
Also when I plug in the new switch and it reboot how do I ensure it becomes the slave without rebooting the live switch?The cables on the switch do they have to go to port1 on the live switch and port 1 on the new switch or can they be port 1 and port 2?
Basically I am trying to use Wireshark to do a packet capture on a Nexus 5010. I want to do a monitor session on on the switch so I can capture from a source port to a destination port on the same switch. I can configure the source port but when I go to configure the destination port I get "ERROR: Eth102/1/4: Configuration not allowed on fex interface". I have tried to reconfigure this port as a switchport but "switchport mode access" command does not take. I don't want to make any changes to any other ports but this one.
View 1 Replies View RelatedNeed your expert input in sorting out the below problem.I have a cisco 6513 switch which is going into SP mode after a reboot whci i have done during BCP activity in my organization.Below are the log for your reference.
Code...
Has any come across show ver memory details on 3750G-48PS as below, One of our Catalyst 3750G running software 12.2(44)SE2 shows unexpected DRAM as below:
cisco WS-C3750G-48PS (PowerPC405) processor (revision F0) with 0K/12280K bytes of memory. This would equate to around 11MB memory which does not seem right... Is it a known IOS bug?
I was trying to configure an SF 300-24 for use in my home and obviously did something dumb. It was working fine. The f/w was updated and I had configured 2 VLANs. VLAN2 was ports 1-6+GE1 for IPTV streaming and VLAN3 was ports 7-24+GE2 and GE3 for the rest of my LAN. I was plugged into GE4 and was configuring the switch with a laptop. GE4 was the only port still on the default VLAN1. I chaged the default VLAN to VLAN3, which forced a reboot and the switch never came back up. Attached is what I see when I connect to the console port: [code]
I can't access to GUI using it's static IP or it's default IP on any port and the console never reaches the point where I can log in. The System light is flashing green but the boot sequence never progresses past what's in the screen shot. I tried to do a hard reset using the recessed button on the front panel but it does not seem to have any effect, no matter how long I hold it down.
Everything is in the title...When I plug a GBIC adapter on a port, my switch reload automatically..! Is it normal, because I did it during production and It disconnects some users.
View 0 Replies View RelatedI have a Cisco WS-C2960S-48TD-L with 12.2(55)SE2.This is a standalone switch, not in stack, and with no order it reboots itself looking for a new master election. On logging i have nothing, but connected with console cable i see the following after 2 minutes of not showing anything:
Waiting for Stack Master Election...
...
The switch reboots and:
...
*Mar 1 00:00:12.289: Read env variable - LICENSE_BOOT_LEVEL =
[URL]
After searching online i have no seeing nothing about disable the feature of the stack so i configure the priority for the "switch 1" to 15 and configure it the switches 2, 3 and 4 to no provision, although this switches don´t exist:
SW_ACCESS(config)#switch 1 priority 15
Changing the Switch Priority of Switch Number 1 to 15
Do you want to continue?[confirm]
New Priority has been set successfully
[URL]
With this new configuration the switch has rebooted again.Why on a standalone switch the stack is rebooting my system?Is it any feature to disable the stack?
I am getting input errors/runts on 2 of my gigabit interfaces that connect to our WAN service provider's network. In relation to total packets, its not a large number, so its probably not a big deal, but I'd just like to find the source so I stop seeing the errors in Solarwinds. Our service provider says that they don't see any errors on their side, but the errors are incoming to us.
I've tried to capture the traffic with Wireshark, but discovered that often these packets are either discarded or padded by NICs so Wireshark will not see them, or at least will not see them as undersized.
Is there any other way I can capture these packets so I can find the source and figure out how to stop them? Our equipment is 3750G running 12.2(55)SE. Its not a trunk port. I know there was a bug in prior IOS that would cause some frames to be marked as runts even though they were forwarded successfully.
recently a Cisco 3560E switch went down due to a power surge. the switch is getting power but i am only seeing the below message continously. it is keep on rebooting. i try to reset to factory settings/ safe boot nothing worked. is there any way i can bring the switch up or it is hardware failure.Using driver version 1 for media type 2Base ethernet MAC Address: 00:23:33:af:1b:00Xmodem file system is available.The password-recovery mechanism is enabled.Using driver version 1 for media type 2Base ethernet MAC Address: 00:23:33:af:1b:00Xmodem file system is available.The password-recovery mechanism is enabled.
View 5 Replies View Relatedwe need to relocate our core switch 6500 with sup 720 to another bldg
what is the command to gracefully shut it down I mean power off
I was told one can just switch off the power
We have Communication Media Module (WS-SVC-CMM) mounted on 6513 switch. It went down twice and we brought it up by applying "power enable module".
View 4 Replies View RelatedCan a Cisco SG300-10P switch power a Cisco SG200-08 switch over POE? Or an SG200-08P power an SG200-08 via POE? I have an area where I'd like to put a small switch, but would like to avoid having to have electrical power run to it. Or will the SG300 and SG200 POE switches only power endpoint devices such as cameras and IP phones?
View 4 Replies View RelatedI have a 6509 that has dual SUP32's.Just want to make sure and give a reason(if there is one). Slot 6 always becomes the active hot on a full reboot. Meaning from no power to the whole switch to powered on. What is the election process for Supervisors?
View 5 Replies View Related