Cisco :: SNMP WS-C2960-24PS-L - NMS Smarts
Apr 9, 2013
I have a problem with adding a Cisco switch to the NMS (Smarts). When I start a discovery process from the snmp manager (Smarts NMS) it does resolve the ip address into the host name but once the discovery process is completed the device in question is not added in the list of managed devices. Attached is basic configuration.
View 4 Replies
ADVERTISEMENT
Jun 11, 2011
I try to configure in both Clean Access Manager and Switch 3560E-24Ps on SNMP Version 2 protocol but I can't make it working together (For CAM and Switch 3560G-48Ps I can do that). [code]
View 3 Replies
View Related
Feb 6, 2012
When using Cisco IOS c2960-lanbasek9-mz.122-50.SE3.bin we can delete line in SNMP group config with
no snmp-server group <group-name> v3 priv context vlan-<vlan-id>
without problems.
But, after upgrade on version c2960-lanbasek9-mz.122-58.SE2.bin there is output:
#####% Ambiguous command: "no snmp-server group <group-name> v3 priv context vlan-<vlan-id> "
It looks like some bug, but there is nothing in the bug toolkit.
View 2 Replies
View Related
Jun 14, 2011
I am not on site and I have not seen a WS-C3750V2-24PS-S. Customer has a stack of 6 x WS-C3750V2-24PS-S and one unit has failed. We do not have a WS-C3750V2-24PS-S spare. Can we replace it with a standard WS-C3750-24PS-S (not V2) switch and be part ofthe stack.
1. Are there any traps gotchas?
2. What about IOS versions - aren't they different for V2 switches
3. Are the stack ports and stack cables same for both WS-C3750V2-24PS-S and WS-C3750-24PS-S
4. What is the main reason for bringing out the V2 switches. What features do they have extra?
View 3 Replies
View Related
Jun 5, 2012
is possible to have WS3750G-24PS in one stack with WS-C2960S-24PS? I want to add two new WS-C2960S-24PS to stack with one WS3750G 24PS.
View 1 Replies
View Related
Oct 27, 2011
what is difference btw c2960-lanbasek9-mz.122-44.SE1.bin with c2960-lanbase-mz.122-44.SE1.bin.I found that these two IOS are available in below link and both two are released in same time... [URL]
View 2 Replies
View Related
Apr 8, 2012
I want to know what is the different between IOS of the catalyst WS-C2960-48PST-S and the IOS of catalyset WS-C2960-48PST-L.a want to upgrad the IOS of a WS-C2960-48PST-S with the IOS of WS-C2960-48PST-L (because this reference has a LANBASE version of IOS).
View 4 Replies
View Related
May 23, 2011
I am trying to buy a GLC-SX-MM SFP module via Fed Stock, and I keep getting a GLX-SX-MM. What is the difference between these two part numbers? I can't find it on the Cisco Web site and eve a search of Google comes up relatively fruitless! Is the GLX compatible with my 3750G-24PS switch?
View 2 Replies
View Related
Nov 6, 2011
I have WS-C3750-24PS version 12.2(55)SE4. I am configuring PBB VPLS. MY PE/P routers are alcatel 7710/7750
my topology is like that.
CE1<-------> Provider_switch(3750)<-------> PE1 < ----IP/MPLS----> PE2<-------> Provider_switch(3750)<----------->CE2
16 11 11
[Code].....
View 3 Replies
View Related
Jan 21, 2013
I have three new 2960 switches as listed in the title. I configured them as follows:
192.168.1.215 host: whse-c
192.168.1.216 host: whse-b
192.168.1.217 host: whse-a
Switches B and C flow into A before continuing on into the server room switch (distance issues).All three switches are configured for ports 21-24 at 1000 and set as cisco switches. all other ports are undefined as they have a myriad of desktops, printers and non cisco access points flowing into them. side question - should i configure them as access points where applicable even if they are non cisco? I am replacing three netgear switches that currently are in place and have no known issues other than they are old and the fans may fail soon.hooked up .217. was able to get to it from the network. Hooked up 215 and then 216. All the sudden I lost the ability to tap into the switches, any of them. (I think I had done 215 at that point too, before adding 216. I found out later it took the network to its knees as internet was lost, and the MPLS stopped functioning.
I undid the changes and put the netgears back in service and all was right with the world again. At first I thought it was a bad host name as I had used whse-a on switch C in error. I changed that after this issue.Later that day I put 215 in place. checked it from the network and could get to it just fine. Then I put 216 in service. I lost connection to 215. I could no longer get to the internet from my pc and the MPLS went down again. This time I just unhooked 216. 215 is still in place and working on the network at the moment and not causing issues. (btw these switches are not even in my path from my pc to the internet, just on the same network) tomorrow I am going to try 217 again while 215 is still on the network and see if there are any issues adding that swtich. if I can do so, and there are no problems, is this an indication of a faulty switch? what further testing can I do, have I missed something in setup? If this brings the network down again, why cant i add two of these switches to each other/on the same network path (B and C were not even connected to each other yesterday evening when it went down again).
View 2 Replies
View Related
Mar 11, 2013
3560 is running c3560-advipservicesk9-mz.122-40.SE. The SFP (GLC-TX) has been tested in another 3560 and is recognized. Both the gi0/1 and gi 0/2 ports show the type as unknown.
Port Name Status Vlan Duplex Speed TypeGi0/1 notconnect 1 auto auto unknownGi0/2 notconnect 1 auto auto unknown
View 2 Replies
View Related
Mar 4, 2012
I am having an issue with VoiP phones giving me an insufficient bandwidth message. I have three remote locations connected to our main building using 2 Mb point to point ethernet solutions through TWC. Each remote location has a Cisco WS-C3560-24PS running IOS C3560-IPBASE-M, version 12.2(25) and have the cable modems plugged into port 1 on them. The remote buildings are labeled 192.168.101.xxx, 192.168.102.xxx, and 192.168.103.xxx. There are 14-16 VoiP phones in each remote building. The main building being in the subnet of 192.168.100.xxx. I have the 3560s connecting to a single port on a 2801 in the main building, all using the subnet of 192.168.253.xxx The phone server sits in our network at 192.168.100.203. I have created the ACLs, class maps, and policy maps on all of the equipment.
For the remote buildings I have the following:
ACL
===========
Extended IP access list VOIP
permit tcp any host 192.168.100.203 dscp ef
permit tcp any host 192.168.100.203 eq 5566
[Code]....
I have put a hub in to capture traffic via Wireshark to see if DSCP flags are being appropriately marked and I do see that all VoiP packets are getting marked with as EF. However, I have been receiving phone calls from people in the remote buildings stating that their phones will cut out, flash Insufficient Bandwidth on the LCD displays and then the call will cut back in. I am wondering if the 2801 is not applying QoS with the rate-limits in mind since it is set to 100 Mb, or is it an issue with trying to take 3 remote locations and bring them down into 1 port on the 2801?
View 6 Replies
View Related
Dec 10, 2011
I'm having trouble stacking a new WS-C3750X-24P with existing switches WS-C3750G-24PS ?I can see the license is on the new WS-C3750X-24P:
switch#sho lic
Index 1 Feature: ipservices
Period left: 8 weeks 4 days
License Type: Evaluation
License State: Active, Not in Use, EULA not accepted
License Priority: None
[code].....
I could put on the c3750e-ipbasek9-mz.122-55.SE1 image, but I may need to get the license sorted still, but not sure if that will work or how to add it if i got one.....
View 2 Replies
View Related
Jul 23, 2012
Can a C3560-24PS switch with 32 MB flash be loaded with IOS 15? Will it be able to execute the code and function properly?
View 2 Replies
View Related
Jun 5, 2013
I receive a question from a future customer about this future if its supported on " WS-C2960S-24PS-L":configuring 2 dhcp server on this swith ( 1 dhcp for voice vlan , and 1 for Data Vlan).I did some search , but i didnt find the answer .i have to advice a customer before ordering the switch.
View 2 Replies
View Related
Oct 27, 2011
I can´t configure speed in a giga port on WS-C3560-24PS-S switch(config-if)#speed ? no negotiate Do not negotiate speed
do you know if the port support speed 100??
because I need to connect with 2955C-12 switch in one port: 100BASE-FX (Multimode Fiber) uplinks, this port its only 100mbps?
and the switch C3750G-12S-E can I configure the ports on 100mbps?
View 4 Replies
View Related
Feb 10, 2011
Just spoke to the TAC and didn't get the information needed. When configuring ip dhcp snooping database I am adding this to my configuration:ip dhcp snooping database scp://dhcpsec@192.168.1.50/home/dhcpsec/switch1.dhcp.database.txt..I assumed that to do this I would either specify the password on the command line, similar to the way its done when using ftp/http, or that I would need to create a public/private key.I have enabled scp and can manually copy a file from the switch to the linux server. So I believe I have all the aaa commands correct. Cisco WS-C3560G-24PS System image file is "flash:/c3560-ipservicesk9-mz.122-55.SE.bin".
View 3 Replies
View Related
Jan 8, 2013
The default value of DRAM and Flash memory are 128 MB and 16 MB of Cisco Catalyst WS-3750-24PS-E switch .I want to know , wherther the default value may be change upto 256 DRAM and 128 Flash.
View 2 Replies
View Related
Aug 8, 2012
I'm configuring AP in Hreap mode. Objective for me is th have a "plug & play" installation method for HREAP. I configure on HREAP AP, Native VLAN set to 1 and the WLAN and Vlan mapping for the current wlan is set to 1 too. WLC version is 7.0.230.0 and AP version is 12.4(23c)JA4
on my cisco switch (WS-C3560-24PS with 12.2(55)SE1), the port configuration is as below:
switchport trunk encapsulation dot1q
switchport trunk native vlan 45
switchport trunk allowed vlan 45,74
switchport mode trunk
no logging event link-status
no logging event power-inline-status
no snmp trap link-status
spanning-tree portfast trunk
spanning-tree bpduguard enable
AP receives a DHCP IP in Vlan 45 and users connected in vlan 45 too. I would like to undestand why the AP is working properly because normally vlan 1 is not configured as allowed vlan on my switch and the native vlan is dedicated only to untagged ethernet packet.
View 1 Replies
View Related
Apr 23, 2012
I have a WS-C3560G-24PS service as a distribution switch with six (6) WS-C2950T-24 connected to it. In looking at the utilization on the inter connect links no one is running close to a gig speed and this includes the link between this switch and the core. The CPU load (6%) and memory utilization (30%) on the switch do not seem bad so what else does one watch to see if it needs an upgrade?
We are starting tohave discussions about any needed upgrades on the network. I have an ocassional user that complaines about low performance but looking through the network I can find nothing glaring on a consistent basis that says an upgrade is warranted. I am however looking at things such as the above. Utilization on links, CPU, memory, etc.
View 2 Replies
View Related
Jan 14, 2013
I've been experimenting with the 'vlan dot1q tag native' command on a switch and it seems as though tagging the native vlan breaks vty access to my access point.With the 'vlan dot1q tag native' commnand applied, I lose management connectivity to the AP with 'no vlan dot1q tag native' applied, connectivity is restored. Why is this? Is it safe to say that one can access the AP via vty lines using ONLY untagged packets?
SWITCH
Model: WS-C3560G-24PS
Code: c3560-advipservicesk9-mz.122-46.SE
--Abbreviated CONF
vlan dot1q tag native
[code]....
View 14 Replies
View Related
Aug 2, 2011
I’m deploying new images on my switch 2960 24TT L. After installing the new image (c2960-lanbasek9-mz.122-58.SE1.bin) and reboot the switch I have always this error message : “Error loading "c2960-lanbasek9-mz.122-58.SE1.bin"
Interrupt within 5 seconds to abort boot process.
Loading "flash:/c2960-lanbasek9-mz.122-58.SE1.bin"...@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ ”
But the switch still boot well. Why do I have this error message?
View 6 Replies
View Related
Jan 8, 2012
I want to restore a backup from c2960 to other one.Why is recommended to remove any security commands, like AAA?
View 2 Replies
View Related
Dec 7, 2010
I have created a username and password with command username Cisco privilege 15 pass Cisco. when i telnet to switch it ask me for enable secret password?????? though i have specified a privilege level 15 to a user.Switch is authenticating with ACS and i have specified a privilege 15 to a specific user on ACS.The IOS is c2960-lanbasek9-mz.122-55.SE.
View 14 Replies
View Related
Oct 11, 2012
We have a Cisco switch in each office and every now and then the port that has the D-Link Wireless AP (DAP-1522) connected to it goes to err-disable state. Actually sometimes even a regular port that has a cisco phone connected may also go to err-disable state (less often). So I have to telnet into the switch and issue shut and no shut command on that interface to get it back to life, then it works for a few days or weeks until it happens again. Any suitable configuraiton for that interface, that would prevent that from happening or a workaround ?
Here's the info:
Model: cisco WS-C3560-24PS and cisco WS-C3560-48PS
Image:c3560-ipbase-mz.122-35.SE5.bin
This is the log from one switch:
31w5d: %PM-4-ERR_DISABLE: psecure-violation error detected on Fa0/2, putting Fa0/2 in err-disable state
31w5d: %PORT_SECURITY-2-PSECURE_VIOLATION: Security violation occurred, caused by MAC address 74e2.f592.f7f2 on port FastEthernet0/2.
31w5d: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/2, changed state to down
And from another, which is almost the same:
5d10h: %PM-4-ERR_DISABLE: psecure-violation error detected on Fa0/3, putting Fa0/3 in err-disable state
5d10h: %PORT_SECURITY-2-PSECURE_VIOLATION: Security violation occurred, caused by MAC address d8a2.5e31.2cf6 on port FastEthernet0/3.
5d10h: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/3, changed state to down
5d10h: %LINK-3-UPDOWN: Interface FastEthernet0/3, changed state to down
Here's the configuration of fe interfaces (they are all alike):
interface FastEthernet0/2
description Voice & Data Combo Port
switchport access vlan 11
switchport mode access
switchport voice vlan 15
[code]....
View 3 Replies
View Related
Dec 30, 2011
i upgrade the IOS for switch c2960 and the swtich do not boot from the new image.
-show version
-show boot
-show flash
View 6 Replies
View Related
Oct 5, 2011
I would like to ask you that how can i know detail P/N on switch WS-C2960-24PC-S I want to know detail what is PC-S and some swith LC-S
View 2 Replies
View Related
Sep 19, 2012
I'm having problems with a cisco switch WS-C2960-24TC-L version 12.2 (50) SE5. every night the equipment goes down, and every morning around 8am comes up.
I know it comes up at 8am because at that time I arrive at my workplace and see the alarm that the switch did not backup the config. ip using his web page and see what's up for a few minutes.
but I never could discover what time vai below. is there any way to see?? with the command show logging don't appear the hoursthat came down...he was only following the hours that he came up ...
View 4 Replies
View Related
Dec 29, 2011
I upgrade the IOS for switch c2960 and the switch do not boot from the new image.See the files attached.
show version
show boot
show flash
There is a mistake with settings?
View 3 Replies
View Related
Dec 26, 2012
We have a customer who uses about 20 x c2960's switches for access layer and 2 x c3560e for distribution layer. C2960's uses C2960-LANLITEK9-M , Version 12.2(58)SE1. Everything was working fine. Now we got information, that sometimes there are problems with connectivity. Customer tries to reach internet.
SW11#sh int fa0/18
FastEthernet0/18 is up, line protocol is up (connected)
Hardware is Fast Ethernet, address is e8ba.806a.4412 (bia e8ba.806a.4412)
[Code].....
View 7 Replies
View Related
Feb 26, 2013
I have a 3com 2948 switch and is needing to put the configuration on a Cisco WS C2960 48 port switch. I am attaching the config to heck if that is correct. I know my IP will need to change to .123
View 7 Replies
View Related
Jan 29, 2012
I am having problem in upgrading Cat2960 because I deleted the flash in this switch already and now I need installing an IOS image? [code]
View 1 Replies
View Related
Mar 12, 2013
I am trying to configure RSPAN for one of my client. They have Server-Client VTP architecture. Voice Recording Server is connected to C4507. Agents are connected to C2960 and C3750. I got 2 sessions configured and the connectivity is a as follows:
1. Voice Recording Server-----C4507-----C2960-----C2960-----Agent IP Phones (Session 1)
2. Voice Recording Server-----C4507-----C3750-----Agent IP Phones (Session 2)
Recording works with Session-2 but not with Session-1. I understand the problem could be due to multiple reasons: 1.1. C2960 is working in client VTP mode so i cannot add remote span command under the vlan configuration. 1.2. C2960 has LANLITE IOS image which i am not sure if it supports Remote Span.
View 2 Replies
View Related