Cisco Switching/Routing :: WS-C2960S-48FPS-L Stack Port Down?
Mar 14, 2013
I'm trying to configure a stack between two WS-C2960S-48FPS-L but does not working.The switch port is always Down.I tried to change de module and cables.I tried to make a loop in one of two switches and the ports always down.
IOS: 12.2(55)SE5
#show switch stack-ports
Switch # Port 1 Port 2
-------- ------ ------
1 Down Down
View 15 Replies
ADVERTISEMENT
Feb 12, 2012
The pinout of poe and poe+ (802.3af) and (803.3at) of these models of Cisco switches?
WS-C2960S-48FPS-L 48 Ethernet 10/100/1000 PoE+ ports; 740W PoE capacityWS-C2960S-48LPS-L 48 Ethernet 10/100/1000 PoE+ ports; 370W PoE capacityWS-C3750-48PS-S 48 Ethernet 10/100 ports with IEEE 802.3af and Cisco prestandard Power
Pin goes where the power for Poe (802.3af) and poe+ (802.3at) for this model Cisco
View 1 Replies
View Related
Dec 18, 2012
I was looking at WS-C2960S-48FPS-L (740 Watts) and WS-C2960S-48LPS-L (340 Watts) models today, I'm not sure that I understand it right,
Does WS-C2960S-48FPS-L model support all 48 ports POE+ (30Watts)? Does that mean each port will get 30 Watts on this switch?
Does model WS-C2960S-48LPS-L support 24 ports with POE and 24 ports with POE+?.
View 4 Replies
View Related
May 29, 2011
We have a 2960 stack of 4 WS-C2960S-24PS-L switches.Sometimes, at random, the stack crashes and reboots. I have downloaded the crashinfo file and can see the following error.
View 7 Replies
View Related
Feb 27, 2012
We have two switches WS-C2960S-24TS-L running in stack with running IOS c2960s-universalk9-mz.122-55.SE3.We have connected two checkpoint devices on Gi1/0/24 and Gi2/0/24 with a simple configuration:
interface range GigabitEthernet1/0/24, gi2/0/24
switchport access vlan x
switchport mode access
spanning-tree portfast
On the devices log we get the following message:
%SW_MATM-4-MACFLAP_NOTIF: Host 0000.0000.fe21 in vlan x is flapping between port Gi2/0/24 and port Gi1/0/24
The mac-address 0000.0000.fe21 is not found on any checkpoint interface. "Show mac-address int gi1/0/24 or gi2/0/24" does not show the correct mac-address of the checkpoint interface connected to the port, but instead shows 0000.0000.fe21.Is there a bug in the IOS, something wrong with the switch config or does it have something to do with the checkpoint config?
View 2 Replies
View Related
Jan 14, 2013
I have a customer with a stack of two switches C2960S-24TS-L that are running 12.2(58)SE2 universal K9, we see that the CPU load increase over time, to 95% and stays there reload solves the problem.the process that akes a lot of CPU is also the SNMP ENGINE, I see that it is running 30 minutes on 95% and then 10 minutes on 35%, this is the only stack were we see this problem. Is there also a SNMP bug in this version ?
View 1 Replies
View Related
Dec 16, 2012
I have a Cisco WS-C2960S-48TD-L with 12.2(55)SE2.This is a standalone switch, not in stack, and with no order it reboots itself looking for a new master election. On logging i have nothing, but connected with console cable i see the following after 2 minutes of not showing anything:
Waiting for Stack Master Election...
...
The switch reboots and:
...
*Mar 1 00:00:12.289: Read env variable - LICENSE_BOOT_LEVEL =
[URL]
After searching online i have no seeing nothing about disable the feature of the stack so i configure the priority for the "switch 1" to 15 and configure it the switches 2, 3 and 4 to no provision, although this switches don´t exist:
SW_ACCESS(config)#switch 1 priority 15
Changing the Switch Priority of Switch Number 1 to 15
Do you want to continue?[confirm]
New Priority has been set successfully
[URL]
With this new configuration the switch has rebooted again.Why on a standalone switch the stack is rebooting my system?Is it any feature to disable the stack?
View 8 Replies
View Related
Dec 19, 2012
We have the following stack configuration:
Switch Ports Model SW Version SW Image------ ----- ----- ---------- ---------- 1 28 WS-C2960S-24TS-L 12.2(55)SE3 C2960S-UNIVERSALK9-M 2 28 WS-C2960S-24TS-L 12.2(55)SE3 C2960S-UNIVERSALK9-M 3 52 WS-C2960S-48TS-L 12.2(55)SE5 C2960S-UNIVERSALK9-M * 4 52 WS-C2960S-48TS-L 12.2(55)SE5 C2960S-UNIVERSALK9-M
View 5 Replies
View Related
Jun 5, 2012
is possible to have WS3750G-24PS in one stack with WS-C2960S-24PS? I want to add two new WS-C2960S-24PS to stack with one WS3750G 24PS.
View 1 Replies
View Related
Nov 27, 2012
I want to know what is the best way to black traffic inside the same VLAN, this VLAN is a user VLAN, it means that I am talking about access layer.I wanted to use private vlan, but C2960S doesn't support this feature. Any other way to prevent any to any traffic in the user vlan, this vlan only have to speak at the Layer 3.
View 2 Replies
View Related
May 19, 2013
I have a stack of 4 3750 Switches.
1. WS-C3750G-12S
2. WS-C3750G-12S
3. WS-C3750X-48P
4. WS-C3750X-48P
The stack cable connected to Switch 1 Port 1 and Switch 4 Port 2 will not come back online. The logs show that there was a Stack line change. I have replaced the 1 meter Stack cable from Switch 1 to Switch 4 three times and it still does not come back online. This is the part that is interesting.. I have disconnected Port 1 Switch 4 and connected it to Port 2 Switch 4 and then Switch 4 came back online. This made me think Port 2 on Switch 4 was working correctly. Then I disconnected Port 2 Switch 1 and connected it to Port 1 Switch 1 and then Switch 1 came back online.
View 1 Replies
View Related
Mar 11, 2013
have a cable i think is bad, is it possiable to switch the cable out without causing any downtime to the switch or connected devices?
HQ-1st-Flr-Stack#show switch stack-ports summary
Switch#/ Stack Neighbor Cable Link Link Sync # In
Port# Port Length OK Active OK Changes Loopback
Status To LinkOK
[Code].....
View 15 Replies
View Related
May 6, 2013
I have a single 2960s without stack module. The stack port has a status of down, however I'd like to disable it so that it does not generate a false alarm in my NMS. The documentation states that there should be a command "switch 1 stack port 1 disable" but the switch (running 15.0(2)SE2) doesn't seem to be available. Is this a dcumentation bug or is the command not there at all?
View 2 Replies
View Related
Feb 7, 2011
I have a stack with a lot of stack-port changes, but on all the ports, how can I determine the faulty switch in the stack, cables are already verified. We did also a restart of the whole stack power off/on
running version
WS-C3750-48P 12.2(55)SE C3750-IPBASEK9-M
This is the output after 6weeks
Switch#/ Stack Neighbor Cable Link Link Sync # In Port# Port Length OK Active OK Changes Loopback Status To LinkOK -------- ------ -------- -------- ---- ------ ---- --------- -------- 1/1 OK 4 1
[Code].....
View 7 Replies
View Related
Oct 11, 2012
I would like to use flexstack to stack two Cisco 2960S 48 Port switches (2960S-48TD-L) for redundancy. Each switch will have a single 10G uplink into our Nexus 7K. One switch in the stack will terminate to linecard 6 (N7K-F248XP-25) and the other switch will terminate to linecard 7 (N7K-F248XP-25). My question is how many flexstack cables are needed? Do I need only one cable or do I need two to connect the two 2960s ?
View 2 Replies
View Related
Aug 7, 2012
I have a stack of 3750G's where the connection between switch 1 port 1 and switch 2 port 2 are down
Stack Port Status Neighbors
Switch# Port 1 Port 2 Port 1 Port 2
--------------------------------------------------------
1 Down Ok None 3
2 Ok Down 3 None
3 Ok Ok 1 2
I have ruled out the stackwise cable as the problem but would like to know which switch has the problem
View 1 Replies
View Related
Feb 23, 2012
2960 switch stack (flex) Spanning tree re-calculate from stack port one?I need to identify with port in the stack is causing the re-calc I have four 48 port switches and show spanning detail only indicates stack port 1.
View 1 Replies
View Related
Sep 27, 2012
I am having an issue on a Cisco 3750 stack where when the stack master is rebooted, all my lacp port-channels drop and then come back up again. After doing some investigation It seems that it is happening because of lacp using the stack master mac-address as part of the system-id, so when the stack master reboots, the stack mac changes. I see that there is the command: stack-mac persistent timer 0
There is this warning about using this command:
When you configure this feature, a warning message displays the consequences of your configuration. You should use this feature cautiously. Using the old master MAC address elsewhere in the domain could result in lost traffic.
My question are:
Are there any other consequences to using this command (apart from moving the switch/mac to another location in the network)It mentions 'If the entire switch stack reloads, it acquires the MAC address of the master as the stack MAC address' Is this still the case if you have the stack-mac persistent timer to 0? Does using channel-group mode on for the port-channels still use the same mechanism of having a system-id? (Will the channels flap using 'mode on' when rebooting the stack master.
View 4 Replies
View Related
Feb 18, 2013
I have two stacks 3750X on two different sites with two links L_2_L, and I want to configure the port channel to aggregate the two links.
Site A Site B
3750X -A1 --------------------------------------( )--------------------------------------- 3750X -B1
( L-2-L )
3750X -A2 --------------------------------------( )--------------------------------------- 3750X -B2
Below the configuration that I have put the two stacks.
site A
interface Port-channel5
description Etherchannel group entre le stack 3750X-A et Switch Lan_2_Lan
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 11,12,999
switchport mode trunk
switchport nonegotiate
speed 100
But the problem is only one link is Bundeled in channel group, see below
Group Port-channel Protocol Ports
------+-------------+-----------+-----------------------------------------------
5 Po5(SU) LACP Gi1/0/15(I) Gi2/0/15(P)
View 8 Replies
View Related
Feb 27, 2013
Is there a stacking cable that is "bent"?Im using this cable:"CAB-STACK-50CM", "Cisco StackWise 50CM Stacking Cable".But it takes up to much room in the back of the switch, is there such a thing as "bent" stacking cable.
View 1 Replies
View Related
Oct 31, 2012
I have 3 switches in my 3750 X stack. I am getting the following error in the logs: %PLATFORM_STACKPOWER-4-PRIO_CONFLICT: Switch 1's power stack has conflicting power priorities. Not sure what I should do next. Below is my Stack-power configuration:
Power stack name: Powerstack-1 Stack mode: Power sharing Stack topology: Ring Switch 1: Power budget: 735 Low port priority value: 20 High port priority value: 10 Switch priority value: 2 Port 1 status: Connected Port 2 status: Connected Neighbor on port 1: c464.1308.7900 Neighbor on port 2: e8b7.4827.e680
Switch 3: Power budget: 729 Low port priority value: 22 High port priority value: 13 Switch priority value: 4 Port 1 status: Connected Port 2 status: Connected Neighbor on port 1: 2894.0fd9.9f00 Neighbor on port 2: 2894.0fd8.e200
Switch 2: Power budget: 690 Low port priority value: 21 High port priority value: 12 Switch priority value: 3 Port 1 status: Connected Port 2 status: Connected Neighbor on port 1: 2894.0fd8.e200 Neighbor on port 2: c464.1308.7900
Each switch has its own 715W power supply in it and all check out OK.
View 3 Replies
View Related
Sep 24, 2012
A site that i am responsible for has the following equipment installed:
2 x 3750G Switches configured as a stack using Stackwise - Collapsed Core/Distribution Layer
5 x 2960G Switches as Access Layer switches
WAN connections into the Core/Distribution Layer are all Gigabit Ethernet over Fibre.This is a dedicated CCTV Network with 50 Cameras all streaming video into the Core (decoders connected to access switches)Each 2960G has 2 links to the Core/Distribution 3750G Switches, 1 to each switch - Gigabit.I'm running rapid-pvst on all switches, so spanning tree is blocking one of the ports and effectively halving the 2 gig bandwidth. Next year our customer is going to add in a further 50 - 60 cameras.After monitoring the current loading on the ports in use, we have suggested to the customer that the 2 connections to each should be Ether-channeled together. [code]
First interface takes commands no problem, keep getting the message that etherchannel cannot be configured across different switches in a stack when i try to put the second interface commands on.
View 8 Replies
View Related
Apr 13, 2011
I just upgraded several of my C2960S-48FPD-L from 12.2(55)SE to 12.2(58)SE and now almost every time I try to SSH to it the switch reboots and gives me these trace backs ...
07:58:52 CST Thu Apr 14 2011: Unexpected exception to CPU vector 200, PC = 1EADA28
-Trace back= 0x1EADA28z 0x1CDC324z 0x1EA5520z 0x1CDC35Cz 0x1CDD0E0z 0x1CDF0C4z 0x1CE06CCz 0x1CE07F8z 0x1D67348z 0x1D611BCz
Writing crash info to flash:/crashinfo_ext/crashinfo_ext_3
07:58:56 CST Thu Apr 14 2011: Unexpected exception to CPU vector 1100, PC = 121BB98
-Trace back= 0x121BB98z 0x12250FCz 0xFA7540z 0xA807B8z 0xA75DF4z 0xA78080z 0x94B708z 0x9717C0z 0x918DD8z 0x936520z 0x9344BCz 0x9345FCz 0x93484Cz 0x1D67348z 0x1D611BCz
=== Flushing messages (07:58:56 CST Thu Apr 14 2011) ===
Buffered messages: (last 4096 bytes only)
0x00000005 R6 = 0x01224F44 R7 = 0x02A23C6C
000089: *Feb 28 18:03:13.577 CST: %PLATFORM-1-CRASHED: R8 = 0x00000080 R9 = 0x00000000 R10 = 0x00000000 R11 = 0x00000071
000090: *Feb 28 18:03:13.577 CST: %PLATFORM-1-CRASHED: R12 = 0x00034855 R13 = 0x00000280 R14 = 0x01CE0778 R15 = 0x00000000
000091: *Feb 28 18:03:13.577 CST: %PLATFORM-1-CRASHED: R16 = 0x00000000 R17 = 0x00000000 R18 = 0x00000000 R19 = 0x00000000
[ code]....
View 9 Replies
View Related
Mar 14, 2012
i have a VSS core that has 4 downstream links to 4 stacked switches. I connected each of the 4 links to different switch in the switch stack. I then created a port-channel that combines all the links from each switch. Is there any issues associated with this setup?
View 9 Replies
View Related
Dec 9, 2012
I am looking for a reasonable switch but it has do do inter-VLAN Routing. I know I could go with a 3560/3750 with IP Services but I am also thinking the 2960S with IP Base IOS might do?
I have looked up the IP Base IOS and it does list IP Routing but how to actually configure inter-VLAN Routing on a 2960S with IP Base?
View 2 Replies
View Related
Apr 19, 2013
I have been trying to enable L3 intervlan routing on C2960S Switch with ip routing command and that was the output from the Switch: [code]
View 6 Replies
View Related
Mar 21, 2012
Is there a CLI-command to see the serial number of the flexstack module installed in a C2960S.
View 13 Replies
View Related
Jun 13, 2013
We have several of these WS-C2960S-24PS-L running 12.2(55)SE5 C2960S-universalK9-M and need to upgrade to a better.IOS since we have a sitution where CPU would get to 100% but we have only a few ports connected.Also we have several of WS-C3750-48P running 12.2(55) SE6 C3750-IPBASEK9-M.
View 3 Replies
View Related
May 10, 2013
Does GLC-GE-100FX is supported on the WS-C2960S-24TD-L. I don't see this switch listed under the compatibility matrix.URL
But the datasheet for the 2960S says this:
"The Cisco Catalyst 2960-S with SFP+ does not support the GLC-FE-100BX, GLC-FE-100FX, or GLC-FE-100LX." But it provides no reference for the GLC-GE-100FX The easy answer is, no the 2960S-24TD doesn't support it, any clarification if possible.
View 1 Replies
View Related
Mar 29, 2012
is it possible to connect UCS FI directly to C2960S using Twin Ax Cable (3M long) ?
View 2 Replies
View Related
Dec 12, 2012
I have a very simple setup containing 3 C2960S switches:switch 1: central switch, acting as router between VLAN 1 en VLAN 2switch 2+3: edge switches, connected via 1 link to central switch, both on VLAN 2,Clients connect to switch 2 and 3 using dhcp, switch 1 uses dhcp relay to forward requests from VLAN 2 to the dhcp server on VLAN 1. So far so good.Now I want switch 1 to add option 82 to the dhcp requests so the dhcp server can see whether the request came through switch 2 or switch 3. I tried turning on dhcp option 82 support on switch 1 by doing.
View 2 Replies
View Related
Apr 1, 2012
WS-C2960S-24PD-LCatalyst 2960S 24 GigE PoE 370W, 2 x 10G SFP+ LAN Base
Can I use the above said switch for 1 Gig Uplinks using SFP.
View 2 Replies
View Related
Jan 21, 2013
I have three new 2960 switches as listed in the title. I configured them as follows:
192.168.1.215 host: whse-c
192.168.1.216 host: whse-b
192.168.1.217 host: whse-a
Switches B and C flow into A before continuing on into the server room switch (distance issues).All three switches are configured for ports 21-24 at 1000 and set as cisco switches. all other ports are undefined as they have a myriad of desktops, printers and non cisco access points flowing into them. side question - should i configure them as access points where applicable even if they are non cisco? I am replacing three netgear switches that currently are in place and have no known issues other than they are old and the fans may fail soon.hooked up .217. was able to get to it from the network. Hooked up 215 and then 216. All the sudden I lost the ability to tap into the switches, any of them. (I think I had done 215 at that point too, before adding 216. I found out later it took the network to its knees as internet was lost, and the MPLS stopped functioning.
I undid the changes and put the netgears back in service and all was right with the world again. At first I thought it was a bad host name as I had used whse-a on switch C in error. I changed that after this issue.Later that day I put 215 in place. checked it from the network and could get to it just fine. Then I put 216 in service. I lost connection to 215. I could no longer get to the internet from my pc and the MPLS went down again. This time I just unhooked 216. 215 is still in place and working on the network at the moment and not causing issues. (btw these switches are not even in my path from my pc to the internet, just on the same network) tomorrow I am going to try 217 again while 215 is still on the network and see if there are any issues adding that swtich. if I can do so, and there are no problems, is this an indication of a faulty switch? what further testing can I do, have I missed something in setup? If this brings the network down again, why cant i add two of these switches to each other/on the same network path (B and C were not even connected to each other yesterday evening when it went down again).
View 2 Replies