I currently have a network with (8) 2960 Cisco Switches. (6) of the 2960 switches are etherchanneled back to (2) 2960 switches in the computer room. I would like to setup QOS on the (8) switches, however the traffic is very differnt on each of the switches. I have video, ip phone, server, printer, PC traffic. I am not sure what the best method of separating this traffic into differnt QOS queues.
Company I work for just moved into a new location. We have two data closets which are patched as independent entities, with no Ethernet tie connection. These closets are roughly 100 feet apart.
There is a fiber connection that runs between both closets, that the previous tenant used to connect the switches. I have placed a Cisco 2960 switch in each location, and added one mini SFP gbic's to each switch. After attaching both sides, neither light up. I do a sh inter gig1/0/49 on each and shows 'down down' (not admin down).
What is the trick on getting these to communciate, do I need to configure these ports, and are they supposed to light up?
What I am trying to accomplish is to get the one closet that is completely cut off, communicating by logically stacking, or 'daisy chaining' via fiber.
I turned off the lights and popped the fiber out, and I do see a faint red light (I did not look straight into it), so I think the fiber is active.
I followed the 3-switch Redundant stacking diagram and now when I boot up the stack Switch 2 is acutally Member 3 and Switch 3 is Member 2.
We plan on having Port-Channels spanning across Switch 1 - Master and Switch 2 (Member 3) of identical port types. Switch 3 (Member 2) is going to have 2 10GIG port channel created.
Is there going to be a problem renumbering the stack as they physically sit or should I just configure the devices based on thier logical member numbers.
I have two 2960s that periodically lose connection for just a few Seconds. If I run a continuous ping from a workstation the connection never drops but as soon as I kill the ping command I will start losing the connection again. All cables test fine tried different switch ports nothing seems to work. No errors in log file either.
After not seeming to be able to save any configurations in 12.2(25)FX, I thought an upgrade would work since it said it didn't recognize my browser or OS but let me continue. I was able to see everything just couldn't save changes.
I updated to 15.0(1)SE3 and everything seemed to be going well. Tried to log back in HTTP (have not set n IP yet since it is still at my house... DHCP seems to be working) and I get a user/password screen that says level_15_access and it won't let me in.
Attempts to log in terminal have been unsuccessful. I can log in my dell switch which I am replacing and my APC units terminal just fine using USB to serial and Ubuntu.
I tried cisco as a password, user and password, admin, administrator no luck.
What is the best way to resolve this, is there a sure fire windows serial program or settings I should use in linux (currently 9600,8,N,1) to connect? I have looked through manuals till I am blue in the face.
I have an existing stack of 4 x 2960-S switches connected by stack cables.I would like to add another 2960-S switch to the stack but am unable to as the 2960-S will only allow 4 x 2960-S switches per stack.how I would add the 5th 2960-S switch to the existing stack of 4 x 2960-S switches.
I have a 24 port 2960-S that is not communicating with a 2960-LST that it is directly connected to over fiber. The link is up on the LST but will not come up on the -S. What command should I use to bring up this link? I have tried no shut from the (Config-if)# prompt.
recently i just connected a non cisco ip phone(from panasonic) to Cisco 2960 POE switch at site A. The PABX system is located at site B,Site A and site B are connected using MetroE Point to point.I would like to apply QoS for voice vlan. I want to assign 2MB to the point to point connection for voice vlan.
My management has tasked me to give them a high level overview of the different switching we can choose for our new building.
This is what I know so far.4 Closets, each closet has 450 ports,One MDF room that is will contain one UCS Chassis and a Nimble iSCSI SAN.
I am working on the spreadsheet and it looks like this (Not totally filled):
2960s3560x3750x45064510Approx cost (Each, 48PORT, POE+, 10G uplink, Dual PS, IP BASE) 6K7K8K45K75KMax Capacity192432432192384Backplane speed206464520520ProLeast ExpensiveStackable to 9Stackable to 9ProDual PSDual PSDual PSDual PSDual PSProLayer 3 opt Layer 3 optDual SupsDual SupsConExpensiveExpensiveConNo Dual PSConLayer 2 OnlyCannot stack more than 4 For the MDF I would like to use 2 Nexus 5548's with FEX's, and the layer 3 daughter board. For the IDF's I was thinking of two 4010's.
I am using a 3750 as a default gateway for multiple Vlans on a few 2960 switches. The trunk lines are configured and working and I have assigned ip addresses to each of the Vlan interfaces on the 3750. My issue is that I can only ping the ip address on the Vlan interface of the 3750 if I have a working computer plugged directly into the Vlan on the 3750. I only have 3 vlans on the 3750 that have hosts directly connected (vlans 2, 10 and 40) the other vlans ( 20 and 70) don't have any clients plugged into them on the 3750 but the hosts reside on 2 different 2960s that connect via trunk ports. How do I keep the vlan interface on the 3750 switch pingable when I don't have hosts directly connected in that vlan on the 3750? (yes, I have enabled ip routing on the 3750)
I have a Cisco SG 300-20 as the core switch, layer 3. It is 192.168.4.6 on VLAN1 and 192.168.5.1 for VLAN2 (VOIP). All the ports are set in trunk mode. DHCP relay is setup on this switch.
The phones connected into a layer 2, Catalyst 2960-S switch. All ports are set in trunk mode. Default gateway on it is set to 192.168.5.1.
DHCP for both VLANs is provided by a Windows Server 2008 R2 server (the relay IP 192.168.4.15).
There is also an ASA 5510 in the mix which is 192.168.4.1. It has a route added to it for the 192.168.5.0 network to go to the SG 300 (192.168.5.1).
Just the two switches can ping each other on the 192.168.5.x network when I "add vlan 2" to the trunk port that is connected between the SG 300 and the 2960. The phones don't get DHCP on the 2960 switch. And I cannot ping 192.168.5.x from the ASA or anything else on the 192.168.4.x network.
After a bit of reading on intra-vlan routing for the SG 300 switch, I am thinking the SG 300 has to be the "center" of things so I need to make it 192.168.4.1 to be the gateway for both VLANs and change the ASA to 192.168.4.2 for VLAN1, etc. And I really can't do asymmetric routing with this switch.
I'm having a strange problem where I'm not able to get through a Cisco 2960-S L2 switch when connected through vpn, while LAN-WAN traffic is working fine.The situation on site is the following:When inside the network I'm able to get to the internet without a problem. The problem is within a vpn-session. When this session is succesfully started I can ping and manage the Cisco 2960-S switch, but I can't ping or manage the Dell switch from my laptop. I can however ping the Dell from the Cisco-switch. [code]
This will be this configuration for all input interface right ? For the Output part I'm lost, what do I have to do ? And for the 2960-2 do I have to put the same configuration ?
We recently updated a site2site link to metro ethernet, ISP call it 100mbps LAN Extension, but to me it is just QinQ over fibre connection. Most went well, one thing (annoying to me) is we can not ping our switches on both ends anymore.
We have a 3750 in headend and another 2960 on the other end. I used to be able to ping/telnet to the management IP from one to the other. Now we can not. I think the ISP is applying some configuration on ports of their customer-premises equipments (both are Cisco switches) but agent in ISP told me no. I thought there is some configuration on Cisco switch to block "MAC discovery" but i just can not remmenber what was that and google also failed me this time.
I have got two links from the same ISP, primary and secondary and connected to two different switch. The ISP have passed the trunk vlan of 30, 31 and 32 on both of the links. The ISP can't provide stp. I have got another managed 2960 series switch. How can I obtain failover on switch level.
I have IP phones connected to 2960 i want to segregate traffic traffic comming from IP phones which has a COS value of 5 and want to allocate a band width of 200 MBPS for those traffic .
Can any one share sample QOS configuration for achiving this in 2960 ?
Have Cisco catalyst 2960 IOS ver12.2(53)se2 when power on the power LED does not come up and on this is what shown on hyper terminal. what need to be done for this switch ?
Boot Sector Filesystem (bs) installed, fsid: 2 Base ethernet MAC Address: b4:d9:8d:27:4c:00 Xmodem file system is available. [code]......
Interrupt within 5 seconds to abort boot process. Boot process failed. The system is unable to boot automatically. The BOOT environment variable needs to be set to a boot able image.
I have an switch 2960 and i have made an SSH connection . But the problem is that whenever i try to open with my teraterm or putty it ask for username and after that password but does take the password. It shows an error of password what should be the problem.
I have an switch 2960 and i have made an SSH connection . But the problem is that whenever i try to open with my teraterm or putty it ask for username and after that password but does take the password. It shows an error of password what should be the problem.
I have a problem with may Cisco, it´s not start, only works the fan, the problem began when y turn down the Cisco and turn on again, but it´s not start. can something tell me what happen whit it.
We are going to upgrade our IOS on our WS-C2960G-48TC-L. But before we do that i want to ask whats the best IOS release to choose. Why we want to upgrade is because our switch software now don't support ssh just telnet access
I was configuring a new Catalyst 2960 switch and had forgotten to set the speed back to 9600 after downloading the new IOS software image. I finished doing all of my configurations and went in to line con 0 to change the speed back to 9600. The change was accepted and I did a 'wr' to save the change, but when I reload the switch it is back to 115200.
I have a statck of 4 2960s switches, with POE powered access points on 2 of them. All of the access points appear to be functioning normally. For some reason, on 3 interfaces connected to access points, I get the following when issuing show interfaces status:
Gi3/0/9 connected: T 7 a-full a-1000 10/100/1000BaseTX ^
My question is regarding the "T" in the status field. I can't find any documentation on this.