Cisco Switching/Routing :: 3560X 24P-S Power Supplies Interchangeable?
Sep 12, 2012
Are the power supplies on these switches interchangeable? I know the model numbers are the same with the exception of the /2 at the end if it. Customer wants it to have a dual power supply but not sure if I need to order a secondary powere supply or just another powere supplu from a spare switch.
View 1 Replies
ADVERTISEMENT
Jun 9, 2013
I am receiving the following error on 3750 stack switches. have already verified the power status and found ok.
IOS used: Cisco IOS Software, C3750E Software (C3750E-UNIVERSALK9-M), Version 12.2(55)SE3, RELEASE SOFTWARE (fc1)
211540: Jun 10 10:45:17.935 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS: Switch 4's power stack has unbalanced power supplies
211541: Jun 10 10:46:18.045 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS:
[Code]....
View 1 Replies
View Related
Mar 12, 2012
I have two WS-C3750X-48PF-S in stack, but every one has just one power supply. In the package of the switches is included one stack power supply cable.does it make sense to use stack power cable if every switch has just one power supply ??
View 6 Replies
View Related
May 14, 2012
I have 6500 core switch with 2500W power supply, and I want to install a second power supply with 3000W ? is this applicable ? if yes, is there a specific configuration that must be done ?
View 4 Replies
View Related
Sep 19, 2012
If I'm upgrading dual redundant power supplies in a Catalyst 4507 from 1000W (data) to 1400W (data), can it be done without taking the switch through a power cycle? I'm guessing no as I read that the switch will not recognize a 1400W PSU in bay 2 if there is still an original 1000W PSU in bay 1.
View 2 Replies
View Related
Jul 26, 2010
We just purchased a Nexus 7010 switch and we are at a stand still with our COLO trying to figure out what power source should be provided. APC recommends a 50amp 3phase vertical cabinet PDU (AP7867). What type of power sourcereakers will be sufficient in handling the Nexus 7k /w (3) power supplies? Do the COLO need to provide single phase or 3 phase power recepticals?
View 7 Replies
View Related
Aug 28, 2011
Is the CAB-C15-CBN - Cabinet Jumper Power Cord, 250 VAC 13A, C14-C15 Connector, supported on the Cisco Catalyst 3750X/3560X. I need to plug the switches into a UPS PDU, that requires a C14 plug.
View 2 Replies
View Related
Feb 7, 2012
Are the LC SFPs interchangeable with the 3560 V2 POE switchThe P/N number we have on the LC SFPs are 30-1301-04.Will this P/N number suit bothe the 2960-S and 3560 switches
View 1 Replies
View Related
Feb 6, 2013
What's the difference between a Catalyst 4500 and a Catalyst 4500E series chassis? I believe it has to to do with supporting PoE+? Are the blades in both series interchangeable?
View 1 Replies
View Related
Jun 9, 2011
I am running a 4507 with the Power Supples PWR-C45-2800ACV. url...
Can I plug this power supply into this UPS unit? url...
View 4 Replies
View Related
Feb 10, 2010
I have a 6509-E with redundant 3000W power supplies (WS-CAC-3000W) but one supply is current non-operational.From the outputs I'm not sure whether the issue is (more likely to be) with the supply to the PSU or the PSU itself, i.e. whether my first action should be to get an electrian to check the supply or fault call the PSU with our maintenance providers and have it replaced?
View 3 Replies
View Related
Dec 5, 2012
CISCO 3945 Routers - Are the 3945 Router power supplies load balanced by default? We are trying to determine if our switch/server rack at our remote location has maxed out it's power load requirements. I just need to know if the 3945 power supplies load balance by default or if the redundant power supply is ON but not really providing the router with power and is just there incase the other power supply fails .
View 3 Replies
View Related
Sep 4, 2012
After stacking two 3750X switches, with four equal power-supply's, with StackWise and PowerStack , still got the next message every few hours %PLATFORM_ENV-1-FRU_PS_ACCESS: FRU Power Supply is not responding (gn4m-rt1p08-04-2)( note that the message revers to the second switch in the stack ) although the stackwise and powerstack on the switches is oke and are working correctly. !
Config : Stack-power in power-sharing mode/strict With CLI on the switch : All the power supply's and stack-power details, prio look OK.
Only: LMS prime /inventory/cisco-view/configure/power supply status result : some power supply's are marked as disabled.with the command > power supply 2 slot a off/on I manage to get the status back to "normal", but after a few hours some power supply's are again marked as "disabled".
Looks like SNMP en IOS difference from opinion.
Hardware
WS-C3750X-24S-S
C3KX-PWR-350WAC
Software
15.0(2)SE
C3750E-UNIVERSALK9-M
View 5 Replies
View Related
Apr 14, 2013
We have two switches of the same model (WS-C3560-48PS-S) that are not providing PoE. I'm trying to remotely determine what the cause of the issue is.
Here is some output.
Hostname#show power inlineAvailable:0.0(w) Used:0.0(w) Remaining:0.0(w)
Interface Admin Oper Power Device Class Max (Watts)--------- ------ ---------- ------- ------------------- ----- ----Fa0/1 auto off 0.0 n/a n/a 15.4Fa0/2 auto off 0.0 n/a n/a 15.4Fa0/3 auto off 0.0 n/a n/a 15.4Fa0/4 auto off 0.0 n/a n/a 15.4Fa0/5 auto off 0.0 n/a n/a 15.4Fa0/6 auto off 0.0 n/a n/a 15.4Fa0/7 auto off 0.0 n/a n/a 15.4Fa0/8 auto off 0.0 n/a n/a 15.4Fa0/9 auto off 0.0 n/a n/a 15.4Fa0/10 auto off 0.0 n/a n/a 15.4(code)
View 1 Replies
View Related
Feb 28, 2011
I have a 6500 chassis with 2 power supplies. At the moment I am using the default configuration:
power-redudancy mode redundant
The problem is that an inserted module is in "power deny" state due too insufficient power.
I know, that It's not a good idea to change into combined mode (loss of redundancy), but my customers requested this anyway.
So I will change to combined mode. So here's the 1 million dollar question: "Which modules will go into power deny, if one of my power supplies fails?"
The 6500 config guide states:
"Power supply is removed withredundancy disabled
• System log and syslog messages are generated.
• System power is decreased to the power capability of one supply.
• If there is not enough power for all previously powered-up modules, some modulesare powered down and marked as power-deny in the show power oper state field."
Well, do you know if there's any way to configure some kind of priority? E.g. I definetly don't want by 10Gig Module or WiSM module to be in power deny. Can i statically make sure, those module will be powered on for sure? Like: "power enable module slot_number" How is this calculated? Or is random?
View 3 Replies
View Related
Apr 4, 2012
In a stand alone 3750x switch configuration, can the secondary power supply only act as a redundant power supply (active/standby), or can it become a "pool" of power similar to power sharing mode for StackPower (somewhat active/active)? I understand there is no stack involved here but I'm curious if this functionality is possible.
View 1 Replies
View Related
Jan 17, 2013
My management has tasked me to give them a high level overview of the different switching we can choose for our new building.
This is what I know so far.4 Closets, each closet has 450 ports,One MDF room that is will contain one UCS Chassis and a Nimble iSCSI SAN.
I am working on the spreadsheet and it looks like this (Not totally filled):
2960s3560x3750x45064510Approx cost (Each, 48PORT, POE+, 10G uplink, Dual PS, IP BASE)
6K7K8K45K75KMax Capacity192432432192384Backplane speed206464520520ProLeast ExpensiveStackable to 9Stackable to 9ProDual PSDual PSDual PSDual PSDual PSProLayer 3 opt
Layer 3 optDual SupsDual SupsConExpensiveExpensiveConNo Dual PSConLayer 2 OnlyCannot stack more than 4
For the MDF I would like to use 2 Nexus 5548's with FEX's, and the layer 3 daughter board. For the IDF's I was thinking of two 4010's.
View 12 Replies
View Related
Mar 6, 2013
i cant find any difference in these two devices when i am trying to compare throughput.I need upgrade our new POP and there will be around 4900 MAC adresses in VLAN 150 and 130 MAC adresses in vlan 200.Uplink is 1 gig routed internet connection and there is 14 downlinks to separate villages.i found a few differences for eg stack interface on 3750x but i dont need it.
View 2 Replies
View Related
May 23, 2012
I unpacked a new 3560x and went to put our standard code version on it c3560e-ipbasek9-mz.122-53.SE2. Everything seemed to upgraded fine but it won't boot to a console prompt. It seems like it loads the IOS image fine but can't get passed the Front-end Microcode IMG MGR: Programming device 0. [code]
View 4 Replies
View Related
Feb 9, 2012
We have a small site that has an Avaya voice switch connected to a c3560x switch.The avaya tech told us to set this on our ports to which the phone and the desktop are connected.
View 4 Replies
View Related
May 14, 2013
I have seen a similar post here from last year about a 10/half connection, but this is different. I have a provider using a 2950 switch (they left CDP on so we can see it). And we have to be set to 10/full to make this connection (as you know 10/half connected here would be or is horrible). I have had this connection running on my 2921 router w/o issue but when I connect it to my 3560X, then I get no link light (shows down/down, not connected).
What else to know about what has been tried: Connecting link to switch with switch set to auto/auto (sp/dup). Speed is 10 (as it should be) but of course w/o the other side pulsing the voltage to know what to auto to, it defaults to half so this is unacceptabel, but, I do get a link light and can pass traffic, it's just a horrible experience.
Also tried the same setting speed and duplex vs. auto disco speed and duplex on other ports of the switch, no difference, same results. Also different patch cables, same results.
My current work around is to connect the providers 2950 (10/full) to my 2921 router @ (10/full) with a BVI to another port on the router which continues on to my 3560X at 1G/full. And this works just fine. Here's more info from my 3560X and the providers 2950:
3560X:
License Level: ipservices
License Type: Permanent
Next reload license Level: ipservices
[Code].....
View 11 Replies
View Related
May 23, 2013
If the 3560 or 3750 "X" series support GRE.I am pretty certain the older 3750-E does not support GRE (both in hardware and software)Was hoping the new super duper X series do. If not, it could get expensive
View 5 Replies
View Related
Feb 18, 2013
I have a 3560X switch with interfaces 36-48 on the same LAN. All interfaces are switchports. Hosts on 38, 39 and 40 are multicast senders: all sending to the same single multicast address. Hosts on 36 and 37 are receivers, having joined that multicast group. I created an SVI for the LAN and put it in ip pim passive. (That is the only PIM mode allowed for an SVI with my IOS.) Show ip igmp snooping groups shows that 36 and 37 are the only interfaces in this group. I attach a laptop to interface 42 and Wireshark, and the laptop is receiving the multicast traffic. The laptop does not join the group. I expect it would not see the traffic.
View 4 Replies
View Related
Jan 25, 2013
last week we have changed the connection of small town from licensed radio to direct fiber with clasic 1gig sfp.After that we have connected the new fiber , we can see 5 min outages of customer internet connection. If we are conncted on the same subnet anywhere on network, we can ping the customer all the time. But if we try to ping the customers public IP it is each 5 min for 5 min unreachable. I have tryed to sho logg in all switches but there are no mesasages. I just see, when comunication have lost, the MAC and IP of customer will disapear from routers ARP tabbel. What is going on?When i enter sho mac address-table i can see customers MAC address in all switches. There are exactly 5 min outages. 5min it runs ok, 5 min outage and it repeats agan.
I looks like the swith blocks the ARP packets from customers to their default gateway.The routers are connected to catalyst 3560x lan base ios, This switch is connected to another 3560x lan base ios and it is connected with fiber to ME3400 where are customers connected.
View 2 Replies
View Related
Jan 24, 2013
I have 3560X-24T-S switches with IP Services loaded at remote sites that I have been having troubles with. Originally, they had IOS 12.2(58)SE1 on them. I have up to four diverse paths via point-to-point microwave at the remote sites. The Microwave equipment is by Microwave Networks and is a Prodeus M series which Ethernet support. The original issue manifested itself as hardware loopback errors on some of the ports that were connected to the microwave links.
My experience in the past has been that when a hardware loopback error occurred it is usually a bad switch port. In this case however, if I disconnected all of the microwave Ethernet links and rebooted the switch and then connected the Ethernet connections to the microwave links again, everything works fine. No hardware loopback errors. That is, until the next switch reboot. Then the hardware loopback error would return. Interestingly, it would come back on different ports connected to the microwave links every time. So if a reboot was done without disconnecting the microwave Ethernet links the hardware loopback error would change from one microwave link to another after each reboot.
I then went through and read the lengthy release notes for IOS version 15.0(2)SE and found several fixes that I thought could fix my issue. So I downloaded it and updated a couple of the offending switches (not all of them were having this problem). After going through the second update required to resolve the 'open file error' that happens going between 12.2(58)SE1 and 15.0(2)SE the problem seemed to be resolved on the offending switches. So, I went ahead and updated the IOS on all of the switches with point-to-point microwave connections.
I now have one switch that was updated that is crashing and rebooting continuously when the Ethernet links for the point-to-point microwave are connected. Again, if I disconnect all the microwave links and reboot, it comes up fine ands stays fine when the microwave links are connected back up. It will work fine until the next reboot and then the crash and reboot loop starts over again. Below is a portion of the putty log when the crash occurs:
----------------------------------------------------------------------------------------------------------------------
previous memory block, bp = 0x59BF838,
memorypool type is Processor
data check, ptr = 0x59BF860
========= Dump bp = 0x59BF87C ======================
59BF77C: 0 0 0 FD0110DF AB1234CD FFFE0000 56 383FDB4
59BF79C: 212AC68 59BF838 59BF6F4 80000042 1 0 A504F53 543A2050
59BF7BC: 6F727441 53494320 506F7274 204C6F6F 70626163 6B205465 73747320 3A20456E
[code].....
View 1 Replies
View Related
Oct 12, 2012
It would be so easy but failed to upgrade 3560X switch to ip services licence is bought and paid for mail and log from the CLI and tftp server attached
View 17 Replies
View Related
Mar 14, 2012
Im going to be ordering a new 3560X L3 switch (ws-3560x-48pf-s). We currently have a 3560 V2 switch and I've read it supports stacking, but looking at the back I just see a console port. Is there an extra card I have to get for this 3560V2 to make it stakable with the 3560X?
View 3 Replies
View Related
Feb 20, 2013
I was viewing the 3560x switch datasheet and i need network module C3KX-NM-10G. I have dark fiber with over 12 km distance to i guess i will be needing SFP EX for single mode.
View 3 Replies
View Related
May 9, 2012
I currently use L3 switches as edge routers to my WAN. I want to use a pair of 3560x switches with IPbase to provide a failover path to my WAN using HSRP at one location but had some problems testing the configuration. My plan is use a virtual address on the LAN interface (VLANx which port gi0/1 accesses) and the WAN interface (VLANy which port gi0/24 accesses). I want switch 1 to be primary since it will have an IPS attached to it, and switch 2 will be backup and used only when switch 1 or the IPS requires maintenance. On both the LAN and WAN sides there is no advanced routing going on, the various hosts just depend on the availability of their respective default gateways, so HSRP should be sufficient to provide a failover in either direction.
In my testing I got 1 or the other link to fail over but not the entire switch. What should my config look like to achieve failover of the entire switch in the event 1 or the other interface goes down, and fail back when the primary links are again available?
View 7 Replies
View Related
Feb 6, 2012
I am stuck at a very early stage in the configuration of 3560x switch. It seemed very unusual and that is the reason, I configured basic config for line con 0 with login local. And then I had just put "enable secret xxxxxx."
Now I simply logged out and when i tried logging in, it is asking for a username. Now the thing is that I had not programmed any username. I tried using just "." followed by my secret password, but it did not work.
View 6 Replies
View Related
Oct 14, 2012
we just got brand new 3560X with LANBASE license installed. Wanted to confirm with a "show license"
To my surprice (output below) I hav IP Services evaluation. I tried to test with an "show ip route" and "ip route..." in configuration mode with no success. How do I use the trial license?
Switch#show license
Index 1 Feature: ipservices
Period left: 8 weeks 4 days
License Type: Evaluation
License State: Active, Not in Use, EULA not accepted
License Priority: None
[Code]...
View 1 Replies
View Related
Mar 17, 2013
if a connect to the switch via Internet Explorer or every other browser I can't enter configuration because I receive a screen as you can view in image below. And I can view those errors:
message: 're_preFlt_txt33' is not defined
Linea: 31
Carattere: 1
Codice: 0
URI:
[URL]
If I connect in HTTPS with IE8 in compatibility mode I view the image as in attachment with_https.jpg.
View 1 Replies
View Related
Nov 1, 2011
why Cisco make 3560x switches with Lan Base(no routing functions)? What happen if I load an Image L3, previously downloaded? my device lost the warranty? or it doesn matter?
View 1 Replies
View Related