Cisco Switching/Routing :: 4507R+E Switch / SVI Interface Not Pinging?
Aug 4, 2012
last day i went to one client for the installation of C(WS-C4507R+E)
current ios :cat4500e-ipbase-mz.122-53.SG2.bin
there is only one sup engine installed and redundant slot is empty.
I installed one ethernet module in the slot 6 and it get detected working fine. I also want to install one fiber module but that module is only supported by 12.2 54 sg or later ios version.so i need an ios upgrade.
For the ios upgrade I decide to do it through svi interface For that i igive an ip address to vlan 1 (192.168.1.2) and plug cable in gigabit 6/1 and added that port into valn 1.
my laptop's ip is 192.168.1.1 @ this point i faced a rare problem the PING IS NOT WORKING.(switch is directly connected to my laptop).
Then i create another VLAN (2) and add that port into vlan 2 still ping is not getting.last thing i tried is that making that gigabit port into a routed port and result is same.
In my preparation for my coming CCNA certification I am experimenting with different network configurations. In my test network I am currently working with a "Router on a stick" setup. A Cisco 2611 router connecting a Cisco 2950 switch. VLANs configured on the switch and subinterfaces + dot1q encapsulation configured on the router. Switch only supports dot1q.Router's Eth0/1 is connected to the Switch Fa0/24 port which is also set to trunk mode. I am using a normal Cat5e twisted pair cable to connect the 2 devices.
VLANs are working since I can connect a workstation to an access port for example fa0/2 (vlan2) and get Internet access.I can also ping any of the subinterfaces of the router from the workstation.With the current setup I am not able to ping the switch from the router, or the other way around, so in other words I can't remote manage the switch from a telnet or SSH session with this setup. What I am missing?Just to be clear I am pinging the switch directly from the router (Router2611#ping 172.16.100.2), so please ignore all static routes and OSPF. [code]
I need to add another SUP engine on Cat 4507R switch, with a new one. I have old SUP engine running in this switch. Sometime this switch is reloaded without any reason. So we want to add another sup engine for redundancy. What is the procedure to do this & also how much outage time would it cause? Which sup engine will be run as primary and which one should be redundancy?
SWITCH-4507#sh ver Cisco IOS Software, Catalyst 4000 L3 Switch Software (cat4000-I9K91S-M), Version 12.2(25)EWA8, RELEASE SOFTWARE (fc1) Technical Support: [URL] Copyright (c) 1986-2007 by Cisco Systems, Inc. Compiled Wed 24-Jan-07 15:28 by pwade
I'm in the process of upgrading my 4507R core to a new 4507R-E. The old switch has Sup IV engines (WS-X4515) running IOS 12.2(40)SG and the new switch has Sup 6L-E engines running 15.1(2)SG. I'm trying to "move" my configuration from the old switch to the new. Below shows the commands configured in the old switch. I'm trying to determine how to implement the same configuration on the new switch since these commands are no longer available.
We made an IOS doBlades on switch 4507R keep block after an IOS downgradewngrade. Before to do it, the equipment comes with blades 1, 2, 3, 4 and we insert "X4418" and "X4548" on blades 5 and 6.[code]
After we made an IOS downgrade to a cisco 4507R from "cat4500e-ipbasek9-mz.122-54.SG.bin" to "cat4500e-entservicesk9-mz.122-53.SG2.bin" (comes with a redundancy supervisor blade WS-X45-SUP6L-E) the standby supervisor keep disable.We tried with the command "Switch(config)#boot system flash cat4500e-entservicesk9-mz.122-53.SG2.bin" then save configuration and "reload" comand but the switch runs with the "...54.SG.bin" IOS.
We erase the configuration with the command "erase/all non-default", before to apply the reload command insert the "entservicesk9-mz. 122- 53. SG2.bin" using the tftp command.The standby supervisory remains on disable state but the active supervisory runs with the desire IOS. In order to downgrade the IOS to the standby supervisory the active supervisore was removed temporarely (previously the switch was off) to make the standby as active, after that made the same procedure with command "erase/all non-default", "copy tftp://(....122-53.SG2.bin), and "reload" command.
The switch was off and re-insert the active supervisory and turn on the switch, after we made the procedure the blade "WS-X4548-RJ45" marks a fault as follows: [code]
The blades were reset but don't have access to them.
I read quite a few documents on configuring SPAN on a cisco switch but none of them mention any limitations or any kind of CPU load it can have on a switch. I need to configure this on one of our switches and would like to know if there are any implications related to SPAN.
We are using CISCO 4507R-E switch as our core/distribution switch. Out of the 7 available slots, 3 are currently being used. Descriptions is as follows:
Slot 1: 6 Port Fiber Line Card
Slot 2: 6 Port Fiber Line Card
Slot 3: Supervisor Engine
Slot 4: Empty
Slot 5: 48 Port Copper Line Card
Slot 6: Empty
Slot 7: Empty
We want to add extra 10 Gbps fiber links (approximately 12) using slot 6 and 7.
We got a switch issue here for 4507R-E with two sup6l-e supervisor running sso redudant. and we found that sometimes client can't ping through the local vlan ip add on the switch , can't logon the cli by telnet too. In the direct connected network device such as access switch and ASA , can't ping or telnet the 4507R too. when we made a forceswitch to sso standby supervisor from console , the problem solve and everything get fine . after that, we switch angin back to the origin supervisor , fine too.
before we made the supervisor forceswitch , we had check the system cpu usage is 15 - 20 % from console . also we had creat a new vlan 200, attach the notebook to 4507's vlan 200 port , the notebook can't ping or telnet the vlan 200 ip interface too.
I have one cisco 4507R+E.My question is if the IOS of the acive SUP crushed and the switch is running through it's second SUP then how to restore the IOS of the first SUP.Also how to access the ROMON mode of the crushed SUP when switch is running through second SUP.
I am getting RTO while pinging my L3 switch 3750 that happened after restarting switch,i have restarted it because I am not able to browse internet through URL,i am able to do it trough ip address, so I restarted it not I am getting RTO.
I'm a networking newbie, but I bought the SG 200-08 switch to do Link Aggregation with and I can't access the web interface. I'm on a mac running 10.7.3, and I've tried Firefox and Safari. I've also tried on a friends PC with Internet Explorer 8.On the mac, I can go into the terminal and can see that the switch has the correct IP address and is seen on both ethernet ports.
I'm a networking newbie, but I bought the SG 200-08 switch to do Link Aggregation with and I can't access the web interface. I'm on a mac running 10.7.3, and I've tried Firefox and Safari. I've also tried on a friends PC with Internet Explorer 8.
On the mac, I can go into the terminal and can see that the switch has the correct IP address and is seen on both ethernet ports:
? (192.168.1.254) at 2c:36:f8:4f:fc:8 on en0 ifscope [ethernet] ? (192.168.1.254) at 2c:36:f8:4f:fc:8 on en1 ifscope [ethernet]
either accessing the web interface or with setting up the Link Aggregation on the switch some other way.
Is there a way to change interface numbers on a 3750 stack but, still retain the config of the physical port?
For instance:
I would like to take the top switch, which has the ports numbered g2/0/1 - 52 and change them to be g1/0/1 - 52. And the bottom switch, which has ports numbered g1/0/1 - 52 and change them to be g2/0/1 - 52. Basically, just swap the interface numbers but, not effect any interface configurations.
I am trying to configure 802.1x wired on a 3560 switch and don't see the required commands under the interface. I am running c3560-ipbasek9-mz.122-55.SE6.bin. I was thinking it might not be available on the ipbase image, but I do have the commands on a 3750g running the ipbase image, so I'm not sure about that.
I have an Issue.In my networks, 1 single user is facing Network Slowness issue. i needs to check to which port user is coneected in switch to CHeck whether that port has any errors.But problem is, i am providing support from remote location.And my concern LAN segment is Very big,I have only user Ip address details,when i ping the Ip address from Core switch it is pinging. but when i give show ip arp & give Ip address then its not learning and listing out the Mac address to trace down to the specific port.
We have a Cisco 3640 router running c3640-is-mz.123-3g.bin Switching ports are devided into several VLans. Each VLan has its own IP subnet. We can't ping IP address X in subnet A from subnet B unless we log into the router and ping it from there first. (and then the IP address will show up in "show ip arp" command. Then we can ping X in subnet A from subnet B, and browse web on device X from subnet B, etc. )
I am trying to make my LAN to work at home. Its pretty small but I am bearly an smart user, noobie if so.I have a Motorola Cable Modem model SB5101 receiving the internet from Shaw Cable.from there I have an ethernet cable to my switch (Cisco SE2500) from there I have two ethernet cables coming out, one goes to my PC and the other one goes to an Airport Extreme so our laptop.I am just here double checking this info... sice this is an unmanaged switch I guess there is no way of accesng an interface to make this happen.I just hate spending the money in something I wont be using just because I dont know whats going on.
I am looking for a way to bind between a switch interface (cat 3750X) and a DHCP server reply.The switch can operate as the DHCP server .a PC connected to interface Gi 1/0/1 will lways get IP address 10.0.0.1 because it is connected to interface Gi 1/0/1, a PC connected to interface Gi 1/0/5 will lways get IP address 10.0.0.5 because it is connected to interface Gi 1/0/5 and so on... (no matter the source MAC address who sends the DHCP request).
I am not getting interface up/down logs in my switch console through show logging command. Switch model cisco WS-C4506-E and IOS :- cat4500e-ipbasek9-mz.122-53.SG3.bin. I have done below mention configurations, we can't configure logging level beyond informational. [code]
We are using Cisco Router 1841 and users reporting issue related to VoIP. After investigation, seeing input errors on Router LAN interface, but there is no error on connected switch interface. [code]
I'm having an issue routing between vlans. I have vlan 1, and 2. I want to ping something on vlan 2, from vlan 1. I cannot ping from a computer on vlan 1 to a computer on vlan 2. I can ping each computer from the ASA 5505. I get an error on the ASA when I try to ping from the computers. The error is Failed to locate egress interface for UDP from voice:192.168.0.199/137 to 192.168.1.200/137. I can't understand why it even mentions IP 192.168. 1.200/ 137... I reset the unit configuring it from scratch and still no go. I have no given a static route to the out yet.. I need to get inter-vlan routing working first. [code]
i configured the VLAN810, with DHCP services, while i try to ping the host which is connected to gi 1/0/2 from my gi 1/0/1 , i can't ping the same vlan host , while i try to debug ip icmp its showing ,
C3750XB11#sh running-config Building configuration... Current configuration : 12053 bytes ! version 12.2 no service pad service timestamps debug datetime msec
I have got new cisco ASA 5580 running 7.2(4) on it when i am trying to configured Virtual interface on vlan 400 in Gi0/0.400 to LBASE.now the problem is from my MZ zone 10.242.107.17 to Lbase virtual interface 10.242.103.1 iam not able to ping.
One of my Catalyst 3750 switch have many out drops, I execute "sh mls qos int g2/0/3 statist" command, there are many output drops in queue3 threshold3. [code]
On a router I can use IP Accounting or Netflow to see what kind of traffic is moving over an interface. Are there any tools on a 3750 switch with a routed interface which would tell you who is hogging the bandwidth on that interface?
i have a stack of 3750x, with minimal configuration. there are two vlans, and two vlan interfaces with IP addresses. when i ping out from this switch to another host, it picks vlan1's ip address as the source automatically. i tested this by doing two pings with extended options using each vlan's interface as the source, and got different results. how the switch decided to use the first vlan's ip address as a source.
I have a 4507R-E chassis with Supervisor IV running IOS 12.2(50)SG. I am trying to configure "auto qos voip trust" on some of the uplink ports. When I try to configure it on a port that is in a channel group, I get the error "AutoQoS Error: AutoQoS can not be configured on member port(s) of a port-channel". I have also tried configuring it on the channel interface, but it is not an available command under the channel interface. Is there a way to do auto qos on the channel interfaces or their member ports or does it have to be configured manually?
sup: WS-X4516-V ios version: cat4500-entservices-mz.122-54.SG.bin ! show process cpu CPU utilization for five seconds: 97%/1%; one minute: 97%; five minutes: 97%
I received an replacement supervisor from Cisco to swap out the failed standby supervisor. I wanted to check if I can pull out the failed supervisor supervisor and insert the replacement supervisor while the switch is still on. In other words, is it hot swappable? Also, will this operation cause interruption of switching inside the 4507R switch?
We are planning for the office move and I need to estimate how much power we need to run a fully populated Cat4507R switch. The chassis include 2 Sups, one 6-port fiber line card, two 48-port Gig and two 48-port FastEthernet line cards. The switch also has redundant power supply (4200ACV 1400W). According to Cisco Power Calculator [URL], I need 49.5 amp 110-120V circuit. It seems to be too much higher than real world. How many 20amp circuit we would need when all the ports are fully utilized?
how to upgrade firmware on 4507 6L-E Sup. There is only 1 Sup on the switch. is there any special requirement to update the firmware when switch not running on redundancy mode?
-core-1#show redundancy states my state = 13 -ACTIVE peer state = 1 -DISABLED Mode = Simplex Unit = Primary Unit ID = 3 Redundancy Mode (Operational) = Stateful Switchover Redundancy Mode (Configured) = Stateful SwitchoverRedundancy State = Non Redundant [Code] ......