Cisco Switching/Routing :: Blades On Switch 4507R Keeps Blocked After IOS Downgrade

Jan 4, 2011

We made an IOS doBlades on switch 4507R keep block after an IOS downgradewngrade. Before to do it, the equipment comes with blades 1, 2, 3, 4 and we insert "X4418" and "X4548" on blades 5 and 6.[code]
 
After we made an IOS downgrade to a cisco 4507R from "cat4500e-ipbasek9-mz.122-54.SG.bin" to "cat4500e-entservicesk9-mz.122-53.SG2.bin" (comes with a redundancy supervisor blade WS-X45-SUP6L-E) the standby supervisor keep disable.We tried with the command "Switch(config)#boot system flash cat4500e-entservicesk9-mz.122-53.SG2.bin" then save configuration and "reload" comand but the switch runs with the "...54.SG.bin" IOS.
 
We erase the configuration with the command "erase/all non-default", before to apply the reload command insert the "entservicesk9-mz. 122- 53. SG2.bin" using the tftp command.The standby supervisory remains on disable state but the active supervisory runs with the desire IOS. In order to downgrade the IOS to the standby supervisory the active supervisore was removed temporarely (previously the switch was off) to make the standby as active, after that made the same procedure with command "erase/all non-default", "copy tftp://(....122-53.SG2.bin), and "reload" command.
 
The switch was off and re-insert the active supervisory and turn on the switch, after we made the procedure the blade "WS-X4548-RJ45" marks a fault as follows: [code]
 
The blades were reset but don't have access to them.

View 1 Replies


ADVERTISEMENT

Cisco Switching/Routing :: Downgrade Firmware On C3750 V2 Switch 24TS-S V07 To 12.2(35) SE5

Apr 10, 2012

Is there a way I can downgrade the firmware on a C3750 v2 switch 24TS-S v07 to 12.2(35) SE5. I have added this new switch to an existing stack but the FW is not compatable. I believe the answer is to upgrade the rest but I cannot afford any down time as they are used to run a CCTV securiy network 24/7. I have included details below to assist with my problem. Switch 4 is the one with a version miss match.

LNB-SWI3750-CTR-01#show verCisco IOS Software, C3750 Software (C3750-IPBASE-M), Version 12.2(35)SE5, RELEASE SOFTWARE (fc1)Copyright (c) 1986-2007 by Cisco Systems, Inc.Compiled Thu 19-Jul-07 19:15 by nachenImage text-base: 0x00003000, data-base: 0x01080000
ROM: Bootstrap program is C3750 boot loaderBOOTLDR: C3750 Boot Loader (C3750-HBOOT-M) Version 12.2(25r)SEE4, RELEASE SOFTWARE (fc1)
LNB-SWI3750-CTR-01 uptime is 19 weeks, 3 days, 22 hours, 46 minutesSystem returned to ROM by power-onSystem image file is "flash:c3750-ipbase-mz.122-35.SE5/c3750-ipbase-

[code]....

View 5 Replies View Related

Cisco Switching/Routing :: 4507R Switch SUP Cards

Apr 19, 2013

I have two types of 4507 switches

1. 4507R
2. 4507R-E
 
and SUP-V and SUP-6-E.So I want to test both SUP cards on both switches which SUP card support which switch?

View 1 Replies View Related

Cisco Switching/Routing :: Secon SUP Engine On 4507R Switch?

Mar 8, 2012

I need to add another SUP engine on Cat 4507R switch, with a new one. I have old SUP engine running in this switch. Sometime this switch is reloaded without any reason. So we want to add another sup engine for redundancy. What is the procedure to do this & also how much outage time would it cause? Which sup engine will be run as primary and which one should be redundancy?
 
SWITCH-4507#sh ver
Cisco IOS Software, Catalyst 4000 L3 Switch Software (cat4000-I9K91S-M), Version
12.2(25)EWA8, RELEASE SOFTWARE (fc1)
Technical Support: [URL]
Copyright (c) 1986-2007 by Cisco Systems, Inc.
Compiled Wed 24-Jan-07 15:28 by pwade

[code]....

View 4 Replies View Related

Cisco Switching/Routing :: 4507R-E How To Implement Same Configuration On New Switch

Feb 26, 2013

I'm in the process of upgrading my 4507R core to a new 4507R-E. The old switch has Sup IV engines (WS-X4515) running IOS 12.2(40)SG and the new switch has Sup 6L-E engines running 15.1(2)SG. I'm trying to "move" my configuration from the old switch to the new. Below shows the commands configured in the old switch. I'm trying to determine how to implement the same configuration on the new switch since these commands are no longer available.

View 2 Replies View Related

Cisco Switching/Routing :: 4507R+E Switch / SVI Interface Not Pinging?

Aug 4, 2012

last day i went to one client for the installation of C(WS-C4507R+E)
 
current ios :cat4500e-ipbase-mz.122-53.SG2.bin
 
there is only one sup engine installed and  redundant slot is empty.
 
I installed one ethernet module in the slot 6 and it get detected working fine. I also want to install one fiber module but that module is only supported by 12.2 54 sg or later ios version.so i need an ios upgrade.
 
For the ios upgrade I decide to do it through svi interface For that i igive an ip address to vlan 1 (192.168.1.2) and plug cable in gigabit 6/1 and added that port into valn 1.
 
my laptop's ip is 192.168.1.1 @ this point i faced a rare problem the PING IS NOT WORKING.(switch is directly connected to my laptop).
 
Then i create another VLAN (2) and add that port into vlan 2 still ping is not getting.last thing i tried is that making that gigabit port into a routed port and result is same.

View 4 Replies View Related

Cisco Switching/Routing :: Effects Of SPAN Port Configuration On 4507R+E Switch?

Oct 29, 2011

I read quite a few documents on configuring SPAN on a cisco switch but none of them mention any limitations or any kind of CPU load it can have on a switch. I need to configure this on one of our switches and would like to know if there are any implications related to SPAN.

View 5 Replies View Related

Cisco Switching/Routing :: Can Put Module On 4507R Switch Running On Live Production

May 2, 2012

Can we put a module on a 4507R switch running on a live production? The module will come from a 4506 switch.

View 8 Replies View Related

Cisco Switching/Routing :: 4507R-E Switch - How To Add Extra 10 Gbps Fiber Link

Sep 30, 2012

We are using CISCO 4507R-E switch as our core/distribution switch. Out of the 7 available slots, 3 are currently being used. Descriptions is as follows:

       Slot 1: 6 Port Fiber Line Card
 
       Slot 2: 6 Port Fiber Line Card
 
       Slot 3: Supervisor Engine
 
       Slot 4: Empty
 
       Slot 5: 48 Port Copper Line Card
 
       Slot 6: Empty
 
       Slot 7: Empty
 
We want to add extra 10 Gbps fiber links (approximately 12) using slot 6 and 7.

View 6 Replies View Related

Cisco Switching/Routing :: 4507R-E / No ARP Virus - Switch Can't Response Ping And Telnet

Apr 10, 2012

We got a switch issue here for 4507R-E with two sup6l-e supervisor running sso redudant. and we found that sometimes client can't ping through the local vlan ip add on the switch , can't logon the cli by telnet too. In the direct connected network device such as access switch and ASA , can't ping or telnet the 4507R too. when we made a forceswitch to sso standby supervisor from console , the problem solve and everything get fine . after that, we switch angin back to the origin supervisor , fine too.
 
before we made the supervisor forceswitch , we had check the system cpu usage is 15 - 20 % from console . also we had creat a new vlan 200,  attach the notebook to 4507's vlan 200 port , the notebook can't ping or telnet the vlan 200 ip interface too.

View 1 Replies View Related

Cisco Switching/Routing :: 4507R+E - Access ROMmon Mode Of Crushed SUP When Switch Running Through Second One

Oct 21, 2012

I have one cisco 4507R+E.My question is if the IOS of the acive SUP crushed and the switch is running through it's second SUP then how to restore the IOS of the first SUP.Also how to access the ROMON mode of the crushed SUP when switch is running through second SUP.

View 1 Replies View Related

Cisco Switching/Routing :: 6513 Compatibility With 10GE Blades

Jun 4, 2012

I am getting conflicting info about this, and need to get confirmations.Is the older 6513 (non E) model compatible with WS-X6407-10GE blade?The switch we're getting this for have WS-SUP720-3B, 6000W power supply, and WS-C6K-13SLT-FAN2.From what I read they are compatible if entered in slot 9-13, but I also heard that 10GE modules are not compatible with the non E chassis.

View 1 Replies View Related

Cisco Switching/Routing :: Catalyst 4500 Versus 4500E Series - Blades Interchangeable?

Feb 6, 2013

What's the difference between a Catalyst 4500 and a Catalyst 4500E series chassis? I believe it has to to do with supporting PoE+? Are the blades in both series interchangeable?                   

View 1 Replies View Related

Cisco Switching/Routing :: Nexus 7K Downgrade Failure

Feb 2, 2012

After trying to downgrade a Nexus 7K from 5.2.1 to  5.1.5 by updating the boot & kickstart boot statements and reloading, I'm now stuck in an endless cycle of reloading. See below:

Is there a break sequence which will allow me to modify the boot statement back to the original via ROMMON or something similar?

[code]....

View 3 Replies View Related

Cisco Switching/Routing :: 3750x / How To Downgrade The Microcode

Mar 22, 2012

Since upgrading a 3750x switch stack to version 15, PC's on the network do not get a DHCP lease. The only way to get them to work is disable and re-enable the NIC card.
 
Downgrading the IOS does not downgrade the microcode on the switches.Is there anyway to downgrade the microcode?

View 3 Replies View Related

Cisco Switching/Routing :: Auto QoS On 4507R-E?

Mar 15, 2010

I have a 4507R-E chassis with Supervisor IV running IOS 12.2(50)SG.  I am trying to configure "auto qos voip trust" on some of the uplink ports.  When I try to configure it on a port that is in a channel group, I get the error "AutoQoS Error: AutoQoS can not be configured on member port(s) of a port-channel".  I have also tried configuring it on the channel interface, but it is not an available command under the channel interface.  Is there a way to do auto qos on the channel interfaces or their member ports or does it have to be configured manually?

View 12 Replies View Related

Cisco Switching/Routing :: 4507R - CPU Utilization 90%?

Dec 15, 2011

I am facing high CPU utilzation for cisco4507R,

sup:
WS-X4516-V
ios version:
cat4500-entservices-mz.122-54.SG.bin
!
show process cpu
CPU utilization for five seconds: 97%/1%; one minute: 97%; five minutes: 97%

[code]....

View 8 Replies View Related

Cisco Switching/Routing :: Catalyst 2960S / Downgrade 10GB Twinax CU SFP Cable To 1GB?

Oct 30, 2012

specifying Cisco devices and I've made an error.I have 2 Catalyst 2960S switches (C2960S-24PS-L).Based on this snippet of web copy from the Cisco website:What's new for the Cisco Catalyst 2960-S Series Switches with LAN Base Software: # 10 and 1 Gigabit Ethernet uplink flexibility with Small Form-Factor Pluggable Plus (SFP+), providing business continuity and fast transition to 10 Gigabit Ethernet I bought a cable assembly "SFP-H10GB-CU3M" (3 meter copper twinax cable with 10GB SFPs on each end).  Unfortunately, it appears after more careful reasearch that my specific model 2960S's are not directly compatible.  , can I force these 10GB SFPs down to 1GB and get them to work with my switches or do I need to return and repurchase?

View 1 Replies View Related

Cisco Switching/Routing :: Are Cat 4507R Supervisors Hot Swappable

Feb 19, 2013

I received an replacement supervisor from Cisco to swap out the failed standby supervisor.  I wanted to check if I can pull out the failed supervisor supervisor and insert the replacement supervisor while the switch is still on.  In other words, is it hot swappable?  Also, will this operation cause interruption of switching inside the 4507R switch?

View 6 Replies View Related

Cisco Switching/Routing :: Power Consumption On 4507R

Aug 2, 2010

We are planning for the office move and I need to estimate how much power we need to run a fully populated Cat4507R switch. The chassis include 2 Sups, one 6-port fiber line card, two 48-port Gig and two 48-port FastEthernet line cards. The switch also has redundant power supply (4200ACV 1400W). According to Cisco Power Calculator [URL], I need 49.5 amp 110-120V circuit. It seems to be too much higher than real world. How many 20amp circuit we would need when all the ports are fully utilized?

View 3 Replies View Related

Cisco Switching/Routing :: Upgrade On 4507R+E Single SUP?

Mar 3, 2013

how to upgrade firmware on 4507 6L-E Sup. There is only 1 Sup on the switch. is there any special requirement to update the firmware when switch not running on redundancy mode?
 
-core-1#show redundancy states   my state = 13 -ACTIVE peer state = 1  -DISABLED Mode = Simplex Unit = Primary Unit ID = 3
Redundancy Mode (Operational) = Stateful Switchover Redundancy Mode (Configured)  = Stateful SwitchoverRedundancy State = Non Redundant 
[Code] ......

View 1 Replies View Related

Cisco Switching/Routing :: 4507R Bootflash Memory

Dec 28, 2011

I have a bootflash in 4507R with the size of 60MB. I upgraded the ios from cat4500-ipbasek9-mz.122-37.SG1.bin (12.8MB Size) to cat4500-entservices-mz.122-37.SG1.bin (13.8 MB SIZE) and deleted the previous IOS.But previous IOS is still getting shown in sh bootflash: command. Furthermore,  dir bootflash: commands shows there is only one IOS , which is running. How I can free the space from bootflash , as I again have to upgrade the another new IOS ( of 16MB), which I tried through solarwinds tftp and couldn't upload successfully because of its limitation. Now, If I try to upload the new IOS through FTP, it gives me memory space error. How I can free the space captured by old IOS and also how I can delete the 3rd unknown entry of IOS (shown below output of commands)?

View 4 Replies View Related

Cisco Switching/Routing :: Config Register On 4507R

Jun 5, 2012

Need to confirm on 4507 R switch should i set config reg to 0x2102  or 0x2101?

View 4 Replies View Related

Cisco Switching/Routing :: Is 4507R FAN Tray Hot Swappable

May 27, 2012

We have a Cisco 4507R switch with sup V. This switch fan tray has partial problem .No light in fan tray. We got another fan tray. Can any one tells me is it hot swappable?

What procedure should I flow without any interruption our live network?

View 4 Replies View Related

Cisco Switching/Routing :: Getting 4507R+E FE0 Management Port?

Nov 1, 2012

Is there some kind of trick to getting the fastethernet 0 management port to come up? My adjacent switch is up/up, but fe0 is down/down. I dont' see how this could be possible. I am getting all my info remotely, but I am pretty sure it's wired up correctly.

View 2 Replies View Related

Cisco Switching/Routing :: 4507R Classic Chassis With Sup 6L-E

Jan 4, 2012

Configuring a 4507R classic chassis with redundant Sup 6L-E?  TAC told me the Supervisor 6LE was only supported on the 4507R+E or 4507R-E chassis but I have found in Cisco documentation several places that indicate that the Sup 6LE is supported in the classic chassis.

View 1 Replies View Related

Cisco Switching/Routing :: 4507R-E - Configuration For VLans

Mar 4, 2013

I'm unable to pass the required vlans networks to my firewall I have different vlans configured for each floor of the building, All these floors have Nortel switches which are connected to the core switch through fiber link.

I have a Cisco 4507R-E core switch. Config for the core switch below: what else has to be done in order to pass the vlans to my firewalls. 
 
Current configuration : 18527 bytes
hostname HQ_Prim_Core_Swt
boot-start-marker
boot-end-marker
enable secret 5 $1$xj2Z$TmV9chRtQWCuXYMsCtBVW/
enable password 7 13521317135C0729
[code]....

View 5 Replies View Related

Cisco Switching/Routing :: Multicast Hogging 4507R

May 30, 2013

i tried a stab and multicasting a FOG image to 4 machines the other day, and i had experienced odd and strange issues.
 
here is what i encountered:,100% cpu usage on our core switch,core4507#sh processes cpu hist
 
    9999999999999999999999999999999999999999999999999999999999
    7777888888888877777888888888888887777788888888888888888887
100 **********************************************************
[Code]...
 
pinging the SVI on the core and or pinging on the core to other devices resulted in MAJOR latencies, packet loss due to the cpu usage, etc.... no other network operations were affected, i could communicate with the rest of the network, and under 1-2ms latencies. i noticed it due to my opsview server flagging the core as down (SNMP OID's wouldnt return a value) 
 
it lasted the whole time i was multicasting, i kept a close eye on it.  i highly considered canceling my job, but everything ran smooth.when i looked at the cpu sorted history i saw 2 processes, IP Input, and cat4k mgmnt hipri 

View 1 Replies View Related

Cisco Switching/Routing :: Configuring 4507R For LACP And Trunking?

Apr 3, 2008

We're trying to configure our Cisco 4507 (Supervisor Engine IV) to allow a new Dell server with a pair of Broadcom 5708 GigE NIC's to aggregate its NIC's to give us a 2gbps link to the switch.
 
So far we seem to have got the team and LACP up and enabled, but the adaptor that the Broadcom Admin Util creates for the team is only showing a 1gbps connection where I would have expected it to show as 2gbps.
 
The individual NICs show as connected at 1gbps. We're not Cisco experts so are struggling on how to get the 2 NICs to aggregate.
 
On the server side we've done nothing other than create a team using 802.3ad LINk Aggregation using LACP.
 
This is what I think the relevent output from "sho conf" is, more available if needed.
 
version 12.2
boot system flash bootflash:cat4000-i9s-mz.122-18.EW1.bin
!
interface Port-channel2

[Code].....

View 3 Replies View Related

Cisco Switching/Routing :: Shutdown 4507r-e And Just Swap Out Blade?

Apr 2, 2012

If i replace a card of the same type in the same slot will I lose the configuration for that card or does it live in the backplane of the device?Is there any special command I need to run to replace the card or can i shutdown the 4507r-e and just swap out the blade?

View 3 Replies View Related

Cisco Switching/Routing :: 4507r / Format Of Flash Caused 100% CPU?

Jul 21, 2012

I had an issue today on a 4507r today where when I formatted the compact flash in slot0: (512mb) it caused the CPU to spike to 100% this took about 1.5 hours and did not cause adjacency loss or any thing, but was worrisome. This was a sup IV  is this normal and should u let it complete like I did?  Also when I copied the os to it from boot flash it caused the same behavior.   I have done this a bunch in 6500 sup 720 without this issue?

View 3 Replies View Related

Cisco Switching/Routing :: 4507R+E / SSO Not Available As Redundancy Mode Option

Oct 31, 2012

Why rpr is the only available redundancy mode option available to me.  I'm running a 4507R+E with twin SUP7-E's.
 
Abbreviated show ver Cisco IOS Software, IOS-XE Software, Catalyst 4500 L3 Switch Software (cat4500e-UNIVERSALK9-M), Version 03.03.01.SG RELEASE SOFTWARE (fc2)Technical Support: [URL]/techsupportCopyright (c) 1986-2012 by Cisco Systems, Inc.Compiled Sun 26-Aug-12 13:45 by prod_rel_team
ROM: 15.0(1r)SG2gp08401 uptime is 6 weeks, 6 days, 4 hours, 59 minutesUptime for this control processor is 6 weeks, 3 days, 2 hours, 21 minutesSystem returned to ROM by RPR SwitchoverSystem image file is "bootflash:/cat4500e-universalk9.SPA.03.03.01.SG.151-1.SG1.bin"Jawa Revision 7, Snowtrooper Revision 0x0.0x1C

[code]....

View 3 Replies View Related

Cisco Switching/Routing :: VISIO Icon For WS-X45-SUP7-E And 4507R+E?

Mar 21, 2011

I´m looking for the VISIO icon for WS-X45-SUP7-E and 4507R+E.

View 13 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved