Cisco Switching/Routing :: Getting 4507R+E FE0 Management Port?
Nov 1, 2012
Is there some kind of trick to getting the fastethernet 0 management port to come up? My adjacent switch is up/up, but fe0 is down/down. I dont' see how this could be possible. I am getting all my info remotely, but I am pretty sure it's wired up correctly.
View 2 Replies
ADVERTISEMENT
May 3, 2013
i have 4507R with dual supervisors (WS-X4013+10GE) with IOS cat4500-ipbasek9-mz.122-46.SG.bin the supervisor module are in 3 and 4, and I want to connection port 5, but i have interface and line protocol down "inactive" error.
So I realized to use command "hw-module" to change the module to GE port. However, I am not able to use the command as" I cannot use the command "hw-module uplink" as well.
View 2 Replies
View Related
Oct 29, 2011
I read quite a few documents on configuring SPAN on a cisco switch but none of them mention any limitations or any kind of CPU load it can have on a switch. I need to configure this on one of our switches and would like to know if there are any implications related to SPAN.
View 5 Replies
View Related
Jan 30, 2012
I have an all gigE 3560. I don't use the management FE0 port on the back. I was thinking to use that for a 100Mbps WAN connection.
Seems to work just fine when I plugged in an test. But I am not routing across that link yet as I still need to setup the far end.
Is there any reason this would not work? I would like to not burn a gig port if the max throughput of the circuit is 100Mbps.
View 1 Replies
View Related
Apr 3, 2012
How does the IP address is assigned on management port of WS4507 R, syntax.
View 2 Replies
View Related
Nov 11, 2010
What is the point of it? It is not a remote console. If i reboot the switch i cannot get back to the out of band management port unless the switch is fully running. Is this only for security purposees? so all telnet/ssh is from an Out of band network?
View 15 Replies
View Related
Oct 25, 2012
I can not find any information about management port of Cisco ISR 2911, 2921 and so on. There is management port in specification of 2911 and 2921 and I do not know if this port can be as a simple Ethernet port – forward traffic in/out on L3.
View 2 Replies
View Related
Jun 19, 2012
I'm trying to get an IP_ADDR set on the management port in SWITCH: mode but for some reason the port seems disabled. PC shows connection unplugged. MGMT_INIT is not a valid command (not listed under '?' ). Bootloader version is 12.2(53R)SE2 FC1.
View 4 Replies
View Related
Mar 15, 2010
I have a 4507R-E chassis with Supervisor IV running IOS 12.2(50)SG. I am trying to configure "auto qos voip trust" on some of the uplink ports. When I try to configure it on a port that is in a channel group, I get the error "AutoQoS Error: AutoQoS can not be configured on member port(s) of a port-channel". I have also tried configuring it on the channel interface, but it is not an available command under the channel interface. Is there a way to do auto qos on the channel interfaces or their member ports or does it have to be configured manually?
View 12 Replies
View Related
Dec 15, 2011
I am facing high CPU utilzation for cisco4507R,
sup:
WS-X4516-V
ios version:
cat4500-entservices-mz.122-54.SG.bin
!
show process cpu
CPU utilization for five seconds: 97%/1%; one minute: 97%; five minutes: 97%
[code]....
View 8 Replies
View Related
Apr 19, 2013
I have two types of 4507 switches
1. 4507R
2. 4507R-E
and SUP-V and SUP-6-E.So I want to test both SUP cards on both switches which SUP card support which switch?
View 1 Replies
View Related
Feb 19, 2013
I received an replacement supervisor from Cisco to swap out the failed standby supervisor. I wanted to check if I can pull out the failed supervisor supervisor and insert the replacement supervisor while the switch is still on. In other words, is it hot swappable? Also, will this operation cause interruption of switching inside the 4507R switch?
View 6 Replies
View Related
Aug 2, 2010
We are planning for the office move and I need to estimate how much power we need to run a fully populated Cat4507R switch. The chassis include 2 Sups, one 6-port fiber line card, two 48-port Gig and two 48-port FastEthernet line cards. The switch also has redundant power supply (4200ACV 1400W). According to Cisco Power Calculator [URL], I need 49.5 amp 110-120V circuit. It seems to be too much higher than real world. How many 20amp circuit we would need when all the ports are fully utilized?
View 3 Replies
View Related
Mar 3, 2013
how to upgrade firmware on 4507 6L-E Sup. There is only 1 Sup on the switch. is there any special requirement to update the firmware when switch not running on redundancy mode?
-core-1#show redundancy states my state = 13 -ACTIVE peer state = 1 -DISABLED Mode = Simplex Unit = Primary Unit ID = 3
Redundancy Mode (Operational) = Stateful Switchover Redundancy Mode (Configured) = Stateful SwitchoverRedundancy State = Non Redundant
[Code] ......
View 1 Replies
View Related
Dec 28, 2011
I have a bootflash in 4507R with the size of 60MB. I upgraded the ios from cat4500-ipbasek9-mz.122-37.SG1.bin (12.8MB Size) to cat4500-entservices-mz.122-37.SG1.bin (13.8 MB SIZE) and deleted the previous IOS.But previous IOS is still getting shown in sh bootflash: command. Furthermore, dir bootflash: commands shows there is only one IOS , which is running. How I can free the space from bootflash , as I again have to upgrade the another new IOS ( of 16MB), which I tried through solarwinds tftp and couldn't upload successfully because of its limitation. Now, If I try to upload the new IOS through FTP, it gives me memory space error. How I can free the space captured by old IOS and also how I can delete the 3rd unknown entry of IOS (shown below output of commands)?
View 4 Replies
View Related
Jun 5, 2012
Need to confirm on 4507 R switch should i set config reg to 0x2102 or 0x2101?
View 4 Replies
View Related
May 27, 2012
We have a Cisco 4507R switch with sup V. This switch fan tray has partial problem .No light in fan tray. We got another fan tray. Can any one tells me is it hot swappable?
What procedure should I flow without any interruption our live network?
View 4 Replies
View Related
Jan 4, 2012
Configuring a 4507R classic chassis with redundant Sup 6L-E? TAC told me the Supervisor 6LE was only supported on the 4507R+E or 4507R-E chassis but I have found in Cisco documentation several places that indicate that the Sup 6LE is supported in the classic chassis.
View 1 Replies
View Related
Mar 4, 2013
I'm unable to pass the required vlans networks to my firewall I have different vlans configured for each floor of the building, All these floors have Nortel switches which are connected to the core switch through fiber link.
I have a Cisco 4507R-E core switch. Config for the core switch below: what else has to be done in order to pass the vlans to my firewalls.
Current configuration : 18527 bytes
hostname HQ_Prim_Core_Swt
boot-start-marker
boot-end-marker
enable secret 5 $1$xj2Z$TmV9chRtQWCuXYMsCtBVW/
enable password 7 13521317135C0729
[code]....
View 5 Replies
View Related
May 30, 2013
i tried a stab and multicasting a FOG image to 4 machines the other day, and i had experienced odd and strange issues.
here is what i encountered:,100% cpu usage on our core switch,core4507#sh processes cpu hist
9999999999999999999999999999999999999999999999999999999999
7777888888888877777888888888888887777788888888888888888887
100 **********************************************************
[Code]...
pinging the SVI on the core and or pinging on the core to other devices resulted in MAJOR latencies, packet loss due to the cpu usage, etc.... no other network operations were affected, i could communicate with the rest of the network, and under 1-2ms latencies. i noticed it due to my opsview server flagging the core as down (SNMP OID's wouldnt return a value)
it lasted the whole time i was multicasting, i kept a close eye on it. i highly considered canceling my job, but everything ran smooth.when i looked at the cpu sorted history i saw 2 processes, IP Input, and cat4k mgmnt hipri
View 1 Replies
View Related
Apr 3, 2008
We're trying to configure our Cisco 4507 (Supervisor Engine IV) to allow a new Dell server with a pair of Broadcom 5708 GigE NIC's to aggregate its NIC's to give us a 2gbps link to the switch.
So far we seem to have got the team and LACP up and enabled, but the adaptor that the Broadcom Admin Util creates for the team is only showing a 1gbps connection where I would have expected it to show as 2gbps.
The individual NICs show as connected at 1gbps. We're not Cisco experts so are struggling on how to get the 2 NICs to aggregate.
On the server side we've done nothing other than create a team using 802.3ad LINk Aggregation using LACP.
This is what I think the relevent output from "sho conf" is, more available if needed.
version 12.2
boot system flash bootflash:cat4000-i9s-mz.122-18.EW1.bin
!
interface Port-channel2
[Code].....
View 3 Replies
View Related
Apr 2, 2012
If i replace a card of the same type in the same slot will I lose the configuration for that card or does it live in the backplane of the device?Is there any special command I need to run to replace the card or can i shutdown the 4507r-e and just swap out the blade?
View 3 Replies
View Related
Jul 21, 2012
I had an issue today on a 4507r today where when I formatted the compact flash in slot0: (512mb) it caused the CPU to spike to 100% this took about 1.5 hours and did not cause adjacency loss or any thing, but was worrisome. This was a sup IV is this normal and should u let it complete like I did? Also when I copied the os to it from boot flash it caused the same behavior. I have done this a bunch in 6500 sup 720 without this issue?
View 3 Replies
View Related
Oct 31, 2012
Why rpr is the only available redundancy mode option available to me. I'm running a 4507R+E with twin SUP7-E's.
Abbreviated show ver Cisco IOS Software, IOS-XE Software, Catalyst 4500 L3 Switch Software (cat4500e-UNIVERSALK9-M), Version 03.03.01.SG RELEASE SOFTWARE (fc2)Technical Support: [URL]/techsupportCopyright (c) 1986-2012 by Cisco Systems, Inc.Compiled Sun 26-Aug-12 13:45 by prod_rel_team
ROM: 15.0(1r)SG2gp08401 uptime is 6 weeks, 6 days, 4 hours, 59 minutesUptime for this control processor is 6 weeks, 3 days, 2 hours, 21 minutesSystem returned to ROM by RPR SwitchoverSystem image file is "bootflash:/cat4500e-universalk9.SPA.03.03.01.SG.151-1.SG1.bin"Jawa Revision 7, Snowtrooper Revision 0x0.0x1C
[code]....
View 3 Replies
View Related
Mar 8, 2012
I need to add another SUP engine on Cat 4507R switch, with a new one. I have old SUP engine running in this switch. Sometime this switch is reloaded without any reason. So we want to add another sup engine for redundancy. What is the procedure to do this & also how much outage time would it cause? Which sup engine will be run as primary and which one should be redundancy?
SWITCH-4507#sh ver
Cisco IOS Software, Catalyst 4000 L3 Switch Software (cat4000-I9K91S-M), Version
12.2(25)EWA8, RELEASE SOFTWARE (fc1)
Technical Support: [URL]
Copyright (c) 1986-2007 by Cisco Systems, Inc.
Compiled Wed 24-Jan-07 15:28 by pwade
[code]....
View 4 Replies
View Related
Feb 26, 2013
I'm in the process of upgrading my 4507R core to a new 4507R-E. The old switch has Sup IV engines (WS-X4515) running IOS 12.2(40)SG and the new switch has Sup 6L-E engines running 15.1(2)SG. I'm trying to "move" my configuration from the old switch to the new. Below shows the commands configured in the old switch. I'm trying to determine how to implement the same configuration on the new switch since these commands are no longer available.
View 2 Replies
View Related
Mar 21, 2011
I´m looking for the VISIO icon for WS-X45-SUP7-E and 4507R+E.
View 13 Replies
View Related
Feb 5, 2013
we have 2 Supervisor IV modules in our 4507, i want to upgrade the IOS as its still on 12.2 and i am going to upgrade it to the latest.
my first question is, if i update the IOS on the bootflash will it replicate to the secondarybootflash?
secondly, can i force a reboot of the secondary supervisor, then the primary after the secondary is up? i'm just trying to minimise downtime and get a plan going.
is there a difference in 12 vs 15 that would impact my current config that i should be aware of?
View 2 Replies
View Related
Feb 18, 2012
I am trying to do policy on the interfaces of my switch WS-4507R, below the configuration I used to shap the traffic to 1 Mbps. However, when I tested it the traffic excceded the 1 Mbps.
class-map match-all 1MB
match access-group name 1MB
!
policy-map 1MB
class 1MB
[code]...
how I can restrict my bandwidth on the interface on 1 Mbps.
View 2 Replies
View Related
Aug 4, 2012
last day i went to one client for the installation of C(WS-C4507R+E)
current ios :cat4500e-ipbase-mz.122-53.SG2.bin
there is only one sup engine installed and redundant slot is empty.
I installed one ethernet module in the slot 6 and it get detected working fine. I also want to install one fiber module but that module is only supported by 12.2 54 sg or later ios version.so i need an ios upgrade.
For the ios upgrade I decide to do it through svi interface For that i igive an ip address to vlan 1 (192.168.1.2) and plug cable in gigabit 6/1 and added that port into valn 1.
my laptop's ip is 192.168.1.1 @ this point i faced a rare problem the PING IS NOT WORKING.(switch is directly connected to my laptop).
Then i create another VLAN (2) and add that port into vlan 2 still ping is not getting.last thing i tried is that making that gigabit port into a routed port and result is same.
View 4 Replies
View Related
Nov 7, 2011
I have an 4507R with one Supervisor Engin V card. I want to add a redundant supervisor engin card to my 4507R Chassis.
Can i use supervisor engin 6-E for redundant or i must use Supervisor Engin V ?
Witch model of Supervisor Engines Supported with this chasis?
View 2 Replies
View Related
Dec 26, 2012
When i have configured the 4507R switch but the configure is not sync with the standby module..... I have doing some troubleshooting
1. type the command "show redundancy" no standby module is showing
2. type the command " redundancy force-switchover" showing the message " no standby module is present"
3. type the command "hw-module module 2 reset" then the standby module is reset and status light is blinking like it is booting..
View 6 Replies
View Related
Dec 5, 2011
I have a 4507R with a WS-X4515 supervisor V. It was booting into rommon mode, so I attempted to boot to an IOS image from TFTP. The boot process hangs at at the end of the below output and the then the status light blinks orange. I left it sit like this overnight, and it remained the same.
rommon 23 >boot tftp://x.x.x.x/cat4500-entservicesk9-mz.122-53.SG2.bin
Tftp Session details are ....
Filename : /cat4500-entservicesk9-mz.122-53.SG2.bin
[Code]......
View 9 Replies
View Related