I have Catalyst 6509 E with redudant SUP720-3B (and MSFC3) running 12.2(18)SXF6 IP Services Lan Only IOS (this IOS requires 512MB DRAM and 64MB of flash) SUP has 512MB DRAM (458720K/65536K) and 512MB sup-bootdisk:, but, there is65536K bytes of Flash internal SIMM (Sector size 512K).
My question is can I put 12.2(33)SXJ3 IP Services Lan Only IOS to this 6500 because this IOS requires 512MB DRAM and 512MB od flash?This is "sh ver" and "dir all-filesystems" of my 6500:
cat6500#sh verCisco Internetwork Operating System Software IOS (tm) s72033_rp Software (s72033_rp-IPSERVICESK9-M), Version 12.2(18)SXF6, RELEASE SOFTWARE (fc1)Technical Support: [URL] Copyright (c) 1986-2006 by cisco Systems, Inc.Compiled Mon 18-Sep-06 23:59 by tinhuangImage text-base: 0x40101040, data-base: 0x42D90000
ROM: System Bo
I have to upgrade two Cisco Catalyst 6509E from Catos to IOS. I would want to know the requirements hardware or software for upgrading. Which are the recommended images I must download? From cat6000-sup32pfc3k9.8-4-5 to the latest stable version of IOS, is it recomended to pass to another previously version before?
I have viewed the following links,[URL]but, it doesn`t mention anything about that. The image below is the result of the "show version" command of one of our Cisco Catalyst.
WS-C6509-E Software, Version NmpSW: 8.4(5) Copyright (c) 1995-2005 by Cisco Systems NMP S/W compiled on Aug 3 2005, 13:13:36
I have a couple of 6509-E combined in a VSS system. I need to upgrade them to support 8 (or 16 at max) 10G uplinks. I already used the two built-in VS-S720-10G fiber connectors for VSL links. Which Ethernet modules do you suggest to use? are there any related upgrades that I have to do?
have 3 Catalyst 3750 in same stack, the IOS version is 12.2(53)SE2. Today we can not telnet/ssh to this switch, but ping is ok, and switch function is ok. I try to access the console port, it show "low on memory, try again later". After I reboot the master switch in the stack, the master switch change to another switch, then I can telnet/ssh to this switch. I check the Ciscoworks server syslog report, there are many MAC address flapping error message, and I beleive the MAC address flapping occured before several weeks. ( the G2/0/15 & G3/0/15 is connect to a VMware ESX server and the EtherChannel config mismatch with this Catalyst 3750 switch ) How to mention the root cause of the "low on memory" problem and what is the abnormal memory usage ( free memory percentage below ?% )?
the problem shows an error in a switch catalyst 2900XL - its a 2924 -, i was copying the image of the ios via xmodem and before finished the the power energy in the facility shuts down, when the energy supply returns the switch get power energy normally but the flash memory doesn't initialized and the loader stuck when i try to initializy the flash or reset
after upgrading about 35 Catalyst 2960 and Catalyst 2960S to IOS 15.0(2)SE2, we experience a memory leak on several switches. After some days / weeks the switches are not accessible via Console/Telnet/SSH/Web any more. Only SNMP seems to work properly.Attached users do not experience any decrease in service.
Trying to connect to the console, we get following error message:
"% Low on memory; try again later"
The only (temporary) solution is to reboot the switch. The behavior is similar to Bug CSCts52797.With regards to the Bug notes this bug should only affect Catalyst 2960 with 64MB of RAM and should already be solved with IOS 15.0(2)SE2.
I have a WS-C3560G-24TS-S running 12.2(50)SE5 with IPBASE. I have been told that the functionality i seek (multicasting) is only available in the IPSERVICES version of the software. I was reading up on upgrading and saw that i needed to do a show license and get the UID and Serial number and get a license that is tied to my box. But the show license command doesnt work wtih my box. i then found something that said that the 3560's were special in that way. Im not sure how to get this box upgraded. I have a different 3560 running the IPSERVICES elsewhere in my organization. Can i take the IOS Version and update my switch to that?
I upgrade the IOS of my switch 3560 from C3560-IPBASE-M), Version 12.2(25)SEB4, To C3560-IPBASEK9-M), Version 12.2(55)SE5 after that the utilizatio of the memory increase to 80% I attached the output of show memory statistics history
We currently have 2 6509s with redundant Sup720-3b's and PFC3B daughter cards which are connected together over dark fibre using the Gb fibre connectivity built into the supervisors.
The requirement is to upgrade this connection to 10Gb as inexpensively as possible.
Do I need to purchase new supervisors in order to do this properly or can I use a separate 10Gbe module (we have a spare slot), i.e. can I get away without using the connectivity built into the supervisors?
The other idea I had was putting a couple of 3750-X switches at each end to sit in front of the 6509s and provide the 10Gb connectivity between sites. I could then use the existing Gb uplinks on the supervisors whilst also providing connectivity for some devices that currently connect to the 6509s but could just as well connect here.
Has any come across show ver memory details on 3750G-48PS as below, One of our Catalyst 3750G running software 12.2(44)SE2 shows unexpected DRAM as below:
cisco WS-C3750G-48PS (PowerPC405) processor (revision F0) with 0K/12280K bytes of memory. This would equate to around 11MB memory which does not seem right... Is it a known IOS bug?
I am trying to find out what the most upto date IOS I can put in my Cisco Catalyst 3500 XL switch, and I'm not sure if this the newest software. I have a lab setup at my house to study for the CCNP certs and this IOS doesn't have all the commands I need, well it might but all depracated commands.
I need to upgrade a Catalyst IOS, but I got a bit confused. The catalyst is currently running "c2960-lanbase-mz.122-35.SE5.bin", but I want to upgrade to "c2960-lanbasek9-mz.122-35.SE5.bin", in order to enable ssh. [code] What are the appropriate steps in order to upgrade to "c2960-lanbasek9-mz. 122- 35. SE5.bin". I have downloaded the tar file (c2960-lanbasek9-tar.122-35.SE5.tar)
1) Do I have to delete the old directory (drwx 192 Mar 1 1993 02:07:21 +02:00 c2960-lanbase-mz.122-35.SE5)? 2) Are these the correct steps to download and extract the IOS? 3) Where will the tar files be extracted? Will an new directory be made or do I have to make one manually?
Got 2 pcs. of C2950G-24-EI which are both running 12.1(9)EA1. Now I was thinking to upgrade them to the latest available (12.1.22-EA14), but before I do this task I'd like to know if there's a way to check in advance if those images will run. Any way to check about available memory or memory needs?
I have upgraded my Catalyst 3750X-switches to software-version 15.0(2)SE2, but I cannot upgrade the 10G servicemodule to the same version. I use the archive download-sw command to load the c3kx-sm10g-tar.150-2.SE2.tar. The file is loaded to the switch, but when the process starts to transfer the file to the module it fails with the following messages:
Error 2: Unable to transfer image to FRU Modul on switch 1Error: Failed to update FRU Module image
The modules is now running with in-compatible versions as shown below:
Switch# H/W Status (CPU/FPGA) CPU Link Version ----------------------------------------------------------------- 1 OK 77C/71C ver-mismatch 03.00.41 2 OK 73C/73C ver-mismatch 03.00.41
i want upgrade my catalyst 2960S and 3560x at midnight, but i am worried about config loss. If i upgrade my switch throught web interface, will need I reconfigure the switch?
I want to run rolling-stack upgrades on several stacks containing Catalyst 3750X-switches. I have done as follows: Configured the redundant uplinks as active and stand-by.Started to upgrade by using archive download-sw /rolling-stack-upgrade /overwrite /reload The upgrade starts as expected BUT switch number 2 in the stack is reloaded BEFORE switch 1 is finnished, the result is of course downtime for the stack. The documentation says something about the command "boot time", but what is this command doing? The default seems to be 7 minutes, it this parameter the time the upgrade-process waits before booting the next switch in the stack? I would expect that switch number 2 is reloaded when switch 1 is up again after reload, and not after an absolute number of minutes, is the rolling-stack-upgrade not working this way ?
I have read that the 3750-X supports upgrading with minimal traffic lost with RSU feature, on the configuration guide the scnario is with the end user connected to the 3750-X stack with LACP and the uplinks to the network running STP, one uplink is forwarding and the other is blocked. I have the same scenario but for the network uplink i also have LACP. When i tried to configured the RU stanby one of the uplink LACP the switch gives an error.
we have installed and implemented a FWSM on cisco catalyst 6509E and defined two virtual contexts.one of contexts work as datacenter firewall. initially it is configured to allow all traffic to datacenter VLAN. (permit any any) on test, it worked fine, except for one problem: all web services had degradation in performance, all server-client (non web) services worked very fine. additionally all https servies worked well.
Users connect to the web server bypassing the proxy, web services are expected to act just like other ones.
I am looking at upgrading an HA pair of ASA5520's from 8.2(2) to 8.3(1), and am just wondering why the huge upgrade in memory is needed. How are Cisco justifying where the additional memory is going to? Are there supposed to be some massive improvements in performance?
I have a new 6509E with 2 sup 2T cards. The 10GE ports on both sup cards will connect to 2 5548s. Can i connect the management interface on the new 6509E to the old 6509 until i free up space to bring the line cards over?
I want to migrate a Cat 6503-E VSS to Cat 6509E VSS. We plan to use the same supervisor that we have on the Cat6503E, for minimizing the configuration change on the Doing this, the vss link will need to be changed, due to the fact that the supervisor slot will change with the Cat 6509, slot 5 instead of 1.
Question: is there a way to just change the vsl-link interface on a existing VSS ?
I'm migrating from a failover pair of FWSM modules across to a failover pair of ASA Service Modules. In order to avoid a "big bang" switchover I intend to migrate subnets from one to the other over a protracted period.With that in mind, whether there is any restriction on having FWSM and ASASM modules in the same chassis? A trawl of the relevant documentation hasn't revealed anything.In this specific case it is Catalyst 6509E VSS chassis pairs with Sup-2T.
I have VLAN X with MTU 9216 on Switch-A. I also have VLAN Y with MTU 9216 on Switch-B. But not their SVIs are MTU 9216.They are not communicating to each other on packet size of above 1500. This is because SVI VLAN X and SVI VLAN Y connect to each other through SVI VLAN Z (Point-to-point Layer-3 connection between two switches). Although SVI VLAN X and SVI VLAN Y communicate through SVI VLAN Z, this inter-link port is a trunk port carrying other VLANs but VLAN Z is a native vlan for which SVI VLAN Z is defined.In order to make it work.
1. Do I need to change SVI VLAN X and SVI VLAN Y to 9216? 2. Change MTU for VLAN Z and SVI VLAN Z to 9216? 3. DO I need to change MTU sizes for other VLANs that are on TRUNK port?
I have a pair of Core VSS 6509E SUP 2T. Two different LANs, two diff. Subnets. larger LAN has been connected to the VSS pair usng normal SVI and Post-Channles (has lots of closets 3750 stacks) and no problem. Second LAN, two closets, stacked and connected to each other via Port channel and trunk + SVI interfaces. Now, I have SVI interfaces for both LANs on teh VSS pair and that is causing traffic from one LAN to jump over to the other VLAN and rightly so because the VSS pair see both subnets as directly connected subnets. I was wondring if I delete the SVI for the second LAN and only keep the L2 VLAN this will be resolved> The reason for the second LAN to connect to the VSs pair is only that It has to go through the VSS pair to get to the WAN router (both LANs will go out through this Same WAN router) but WAN router is not my concern at this time. I need to isolate these two LANs/subnets traffic so no one VLAM traffic jumps over the other.I have also thought about VRF but at this point I am not sure if teh 3750 stacks supports VRF and if it does how to implement VRF on the second and samller LAN to just allow it go through the VSS pair in order to get to the WAn router.
I have a 6509E switch with dual 6Kw power supply that is logging "Power supply 1 input has changed. Power capacity adjusted to 2671.20W" then will bounce back to normal at random times from 1sec to 10sec. Is there a command to check what each input level of the power supply to try to identify possibly which source is causing the problem? The power supply input lights remains green while this is occuring.
Trying to find documentation on the proper procedure for installing a second sup720 into our 6509-E chassis for sup redundancy. I have found documents that tout how 'cool' and 'awesome' NSF/SSO, and all that is, but haven't found any docs on installing a second sup720 into a chassis that is currently in production and is only running one sup720. In all the years that this chassis has been out, there must me a documented procedure out here to explain this.I have been through the following pages, and have found nothing to this effect.
upgrade experience with the 6509E on what IOS version to use. This is a new install, so I want the most current version that supports SSH and works with dual supervisors.
Here is some information: WS-C5609-E with 983008K/65536K bytes of memory Current version 12.2(18)SXF17b Slot 5 Supervisor 720 (Active) Slot 6 Supervisor 720 (Hot)
Just need a strong base code, no advanced services. Let me know if you any additional information.
Looking at the specs for WS-X6704-10GE, it shows the port buffers at 16M per port. This doesn't seem like very much for a 10G port. Is this upgradable or related to how much RAM is in the blade?
We are experiencing with high CPU input due to ARP input between 20:30 and 22:30 every day At this time we have a lot of backup operations. When I look the netflow report, I can't see anything anormal.
We are changing our backup server's NIC card from 1gig to 10Gig. The backup operation's traffic is high (approx 2Gbps level) but 6509 has to be handle this size of traffic.
We are using two 6509E in VSS mode and our image version is s72033-adventerprisek9_wan-mz.122-33.SXJ.bin
20:00 show ip arp summary -------------- 2588 IP ARP entries, with 166 of them incomplete