Cisco Switching/Routing :: Enabling Jumbo Frame On N7K With FEX Attached
Oct 4, 2012
I have a pair of N7K's in vPC topology with some FEXs attached. I am looking into enabling Jumbo frame on the N7K as well as the FEX. I understand Jumbo frame is enabled globally by default.
My question is I have some interfaces in a port-channel that I need jumbo frame enabled. Do I enable it at the port-channel interface or at the physical interface ? and is the change disruptive to the network ? I am running NX-OS 6.0.2.
I've had a read through the docs for the 3750 series switches, but nothing that definately says that jumbo frame routing will work on a SVI.One part specifically I'd like clarification on is:The default maximum transmission unit (MTU) size for frames received and sent on all interfaces on the switch or switch stack is 1500 bytes. You can change the MTU size to support switched jumbo frames on all Gigabit Ethernet and 10-Gigabit Ethernet interfaces and to support routed frames on all routed ports. It says supported routed frames on all routed ports, but this in the past has meant physical ports, and not Virtual ones.
I would like to configure Ethernet jumbo frame setting in a C6509E switch with WS-X6548-GE-TX and WS-X6516A-GBIC port modules, and IOS 12.2(33)SXJ1. whether any of these modules can support jumbo ethernet frames up to 9000 per port bases.Also, if none of these modules support port-based jumbo frame MTU then would the switch allow jumbo frames on Ethernet trunks from an access switch (say a C3560)?
I have a pair of Catalyst 3560 GB switches that are trunked with two of the standard ports, and that have trunk ports connecting to a failover pair of PIX 515e's. We're considering adding a pair of cluster database nodes and an iSCSI SAN, both of which would need a dedicated interconnect VLAN that I'd like to employ Jumbo frames on. I don't necessarily need the VLANs to traverse the firewall trunks since they're private interconnects, but I need each host to traverse the switch trunks.
Since it seems I can only enable Jumbo frames on the entire switch (current standard frame size is 1500 and jumbo is also 1500), when I enable it what kind of possible negative impact could this have on my trunked ports as well as my host connections? I've read mixed reviews of users with iSCSI SAN devices seeing terrible performance when enabling jumbo frames so I'm apprehensive about enabling them on an existing network.
I attempted to enable jumbo frames on a Nexus 5010 (NX-OS version 4.2(1)N1(1)). I created the policy map below and lost access to the switch.
policy-map type network-qos jumbo class type network-qos class-default mtu 9216
After recovery I see from the logs that all vlans and interface were suspended. I've attempted to look for reasons for a compatibility issue but I am unable to find what is checked and what could have been incompatible. The other troubling thing is the adjacent switch suspended its interfaces too but no change was done there. What I need to look out for so that this does not happen again?
2011 Nov 22 23:43:09 phx-ipcg1dwfcma %ETHPORT-3-IF_ERROR_VLANS_SUSPENDED: VLANs 1,10,601 on Interface port-channel1 are being suspen ded. (Reason: QoSMgr Network QoS configuration incompatible) 2011 Nov 22 23:43:09 phx-ipcg1dwfcma %ETHPORT-5-IF_TRUNK_DOWN: Interface port-channel1, vlan 1,10,601 down 2011 Nov 22 23:43:09 phx-ipcg1dwfcma %ETHPORT-3-IF_ERROR_VLANS_SUSPENDED: VLANs 10 on Interface port-channel508 are being suspended.
I currently have 4 3560 switches connected in a Mesh topology. These are all set to use Jumbo Frames and so are all the Servers that are connected to these.I now need to connect a 2950 switch to 2 of the 3560's which will have only desktop computers connected to it but i do not want to configure Jumbo Frames on this and any of the desktops.
I have a Nexus 7000 plus 6 boxes NX2000 on backbone.I have configured on 7000 :
conf t system jumbomtu 9000 exitERROR: Ethernet111/1/1: requested config change not allowed ... ERROR: Ethernet122/1/48: requested config change not allowed 1/111/14 is a NX2000 port conf tinterface ethernet 1/111/14 switchport mtu 9000 exit
I have gotten this message : Error: MTU cannot be configured on satellite port(s) - Eth122/1/11 ?I have tried on a NX7000 TP port:ERROR: Ethernet10/45: MTU on L2 interfaces can only be set to default or system-jumboMTU ?Does JUMBOMTU configuration can be done only when there are no NX2000 configured ?
I've to enable it on 3750 and nexus 7K switches. what are the steps involved? can we enable jumbo frame per port instead of enabling globally? i.e. we will only have few ports that will be using jumbo frames, rest of the ports will be using default 1500 MTU size.
on some of our ports on Nexu 5000 and on the connected FEX we can see a lot of Jumbo Packets though there is not enableed any JumboFrame on the Switch, all Interface and system MTU is set to 1500.
DBE-LINZ-XX41# sh int Eth113/1/27 Ethernet113/1/27 is up Hardware: 100/1000 Ethernet, address: d0d0.fd1b.b69c (bia d0d0.fd1b.b69c)
We have a requirement to send span traffic to a destination port for monitoring purposes on two 5000s with some 2000 fex boxes attached. Some of the servers are making use of frames larger than 1500. we have not changed any mtu configuration on the 5000 since installation, and I can see the policy maps is still on 1500.
My first assumption would be that frames larger than 1500 will not be dropped, but it seemingly not (see below). is there a reason why the switch would forward jumbo frames? Also, is there a limitation on MTU for span traffic? There is a MTU command under the span session, but the maximum is 1518. From what I can read the frame will be truncated if it exceeds this. Does that mean the fragments will be dropped?
I believe i've enable jumbo frames on our Nexus 7010, one in each data-centre.
system jumbomtu 9216. Also on the interfaces mtu 9216. And can see MTU 9216 bytes, BW 20000000 Kbit, DLY 10 usec on the port-channel between them. Though when i ping between vlans at each site with large packets i get 30% drops and if i set the DF bit in IP header to yes - 100% loss.
8798 bytes from 10.200.12.2: icmp_seq=19 ttl=254 time=8.024 ms --- 10.200.12.2 ping statistics ---20 packets transmitted, 14 packets received, 30.00% packet loss
I understand that jumbo frames need to be enabled end-to-end. I have two ESX hosts connected at each site. I want to enable jumbo frames for those ports, but what if not all host on the ESX are using jumbo frames, will I have drops and connection failures? So if i have two sites, each with a 6509 connected via a trunk and need to enable jumbo frames for a vlan between the sites how do I accomplish this?If I enable jumbo frames on the trunk link how does that impact other traffic between the sites?
I have a switch that I have configured for jumbo packets, but they don't seem to be functioning. I have set system mtu jumbo 9000. The hosts are connected via 2x EtherChannel links. The hosts are jumbo frame enabled, and can ping their own local address using jumbo packets & do-not-fragment flags on the pings. They cannot, however, ping each other or the switch that way - it always says that the packet requires fragmentation. I know the attached machines (they're all VMs) and virtual switches support jumbos because I can ping within the virtual interfaces of the VMs. It's just traffic that goes over the switch that fragments.The switch is a WS-2960G-48TC. Here are the various outputs, with a section of config at the end.
hrnacancwtdevs3#show system mtu System MTU size is 1500 bytes System Jumbo MTU size is 9000 bytes System Alternate MTU size is 1500 bytes Routing MTU size is 1500 bytes
I have a Cisco Nexus 3064 that I am using as part of a flat network for the Lab. I have 30 Virtualization Servers(MS HyperV and VMware vSphere) connected to this switch and I want to enable jumbo frames. The Virtualization Servers are able to ping the local VM's using 8K bytes. However I am unable to ping from server to server using 8K bytes. I have configuration (in abbreviation). All the servers are in the same network which I configured as L2 ports with the "switchport" command. However, the interface "MTU" command is unavailable in L2 mode. I am only able to get the interface "MTU" command only in L3 mode with the "no switchport" command on the interface.
# int eth1/2-45 # no switchport # mtu 9216 # no shut
I can ping the servers with less than 1500 bytes, but anything larger fails.
I have a Cisco Catalyst 3100 blade in a Dell server chassis that is trunked to a 6509.
When doing a protocol capture, I see large frames being sent from one of the servers in the chassis.
Example:
TCP:[Continuation to #1701] [Bad CheckSum]Flags=...AP..., SrcPort=HTTP(80), DstPort=2667, PayloadLen=2831, Seq=1489611217 - 1489614048, Ack=1719592331, Win=65535 I see lengths up to 6900+ bites coming from the server.
The switch has the global MTU set to 1500
system mtu routing 1500
and I can't seem to set this at the interface level. The server is configured to send 1500 length frames. Why am I seeing these jumbos? (the server is Windows 2003)
The server team has asked me to implement jumbo frames on a single VLAN, the one they use for v motion. We have two pairs of 5548s, each pair running VPC for most connections. I am aware of many postings that describe how to enable jumbo frames globally, like this:
policy-map type network-qos jumbo class type network-qos class-default [code].....
I am not clear how I can extend this principle to one VLAN only.
Also, I am aware of a posting [URL], that shows some pitfalls of implementing jumbo frames in a VPC configuration. Pretty well all my connections are VPC, including all the FEXes, which are all dual-homed. In many cases, the VPC extends through to the servers so that the servers run port.channels across two FEXes. I am unclear whether the pitfalls are still valid, or whether I have to wait until my next maintenance slot (6 months away) to implement jumbo frames. Can jumbo frames be implement safely on the fly? How does enabling jumbo frames fit in with "conf sync" mode?
I am trying to determin if Jumbo frames are enabled on out Nexus 7000, and I am getting mixed info back from the swtich.I looks like the system jumbo MTU size is 9216 by default, but the interfaces all say the MTU of the interface is 1500 bytes. According to this article, the interface MTU should read 9216 is the jumbo frames are enabled globally. Is this correct. Is there a way to verify if Jumbo frame support is turned on? [code]
We have a number of sites which have high-speed L2 links which terminate on our L3 switches at each site. The ports are between the sites are placed in routed mode.
I would like to use Jumbo frame between two of the network which will communicate across sites and 1500 mtu on the rest, is this something which is possible?
From my understanding is the mtu is set on the interface therefore if I set the mtu on the L2 link ports on both sites to 9000 then would this cause a problem for the 1500?
My question is wrt policy-based routing on my network. Our switch is a 3560G 24PS running Adv Ip Services image. It is connected to an 1841 and an 1811 each with a dual-wan connection . The 3560 defines 6 vlans and we are using PBR to route some vlans via the 1841 and some vlans via the 1811.
From a client on one vlan a traceroute to a client on another vlan goes through the 1811 before being routed back to the 3560. Is it possible to use PBR to detect traffic that is destined for another vlan on the same switch and then route it directly?
We are currently using two Nexus 5548UP's as our Datacenter Network Core. I have a pretty simple objective: I would like to enable Jumbo Frames on a single VLAN only(VLAN 65). This VLAN is used strictly for backups. I do not want to enable Jumbo Frames on the other VLANs(VLANs 1-10). Im not sure what the best way to do this is.....or if it is even possible but I am hoping to get some configuration examples.
Our customer is having C6513 running with 12.2(18)SXF15a . One of the module (ACE20-MOD-K9) got rebooted with following error: Feb 22 10:41:41.155 GMT: %OIR-SP-3-PWRCYCLE: Card in module 6, is being power-cycled off (Reset - Module Reloaded During Download)Feb 22 10:41:41.183 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 6 set off (Reset - Module Reloaded During Download)Feb 22 10:41:53.686 GMT: %OIR-SP-3-PWRCYCLE: Card in module 6, is being power-cycled off (Module not responding to Keep Alive polling)Feb 22 10:41:53.686 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 6 set off (Module not responding to Keep Alive polling)
Is there a way to configure a switch (3550, 3560,3750) to disable a switch port if it has not been used for a specified time period such as weeks or months. Say you want the switch to disable switch ports that have been "abandoned".
Lets say i have 2 3750 switches stacked via backend stack cables. Now if a packet needs to go from 1 switch in the stack to second switch in the stack, will it travel via stack cable or do we need to connect both switches via uplink ports (ethernet or sfp). I tried reading datasheet but it no wheres mention the actual frame path between switches in stack.
We have the port on the switch set like this: switchport port-security maximum 25 switchport port-security switchport port-security aging time 2 switchport port-security violation restrict switchport port-security aging type inactivity
In case a device connected to the port is inactive for more than 2 minues ( aging time ) the first frame/packet the device generates arrives to the port on the switch, but the switch does not forward it to the appropriate port ( discards it or whatever ).
So far I tested on 1 30 WS-C3750E-24PD 15.0(2)SE2 C3750E-IPBASEK9-M 2 30 WS-C3750E-24PD 15.0(2)SE2 C3750E-IPBASEK9-M 3 52 WS-C3750G-48PS 15.0(2)SE2 C3750-IPBASEK9-M
[Code].....
When we remove port security from the port, it works perfectly fine, as expected.
It seems this is not HW or IOS version related. It seems it is not a stack synchronization issue, it does not matter if a device is connected to the first or other stack member. I tested on C3560 too, here there are no problems, so seems it is 3750 related.
I have catalyst 3750 I want to controle traffics on every port I have tried Frame-Relay Traffice shaping and Quality of service but there is no support for these commands in the switch.do we have any way to limit traffic on every port in catalyst 3750 and 2960 switches ?
I need to get some low volume, interactive data, prioritized on frame relay PVCs across our network. I have followed the CBWFQ examples from cisco.com, but my test packets are still showing latency over 1 second. My lab set up has a corporate connected gateway router linked via FE to testrouter 50. TR51 has a T1 frame relay loop to another router acting as a frame relay switch. The other side of the FR switch has a 56k link to testrouter51. I am sourcing test pings from my desktop PC, that are marked as AF43, and leave at a rate of 1/second, when the response comes back in time. I am using a Smartbits to generate some default class traffic at a rate of about 56Kbps only in the 'outbound' direction, toward TR51, as this emulates a file copy from corporate to remote sites, that is causing the AF43 traffic to suffer. Here is the relevant config on the TR50 device:
class-map match-all rtu-data match ip dscp af43 ! policy-map frame-56 class rtu-data priority percent 20 class network-mgt-data bandwidth percent 5(code)
I have an 881 router here in house and am attempting to enable the gui interface on the router.
I have tried the steps to enable http but have not had any success. Below is the IOS Version and the portion of the show config that reflects the http allow:
ROM: System Bootstrap, Version 12.4(15r)XZ2, RELEASE SOFTWARE (fc1) Cisco 881 (MPC8300) processor (revision 0x100) with 249856K/12288K bytes of memory. Processor board ID FTX1249Y16Q
after installation of demo versions of 2900-SEC-TEMP & 2911-2921-SSLVPN-TEMP & rebooting the 2911 router I do not have access SSL commands.Show license indicates that 2900-SEC-TEMP & 2911-2921-SSL-TEMP licenses are active but NOT IN USE.
I have two WS-C2960-24TC-L Switch with Software Ver 12.2(25r)SEE6 with image c2960-lanbase-mz.122-35.SE5.bin and 12.2(25r)SEE1 with image c2960-lanbase-mz.122-25.SEE2.bin currently on it.
I want to enable SSH connections on the switches and believe I need to import the cryto image onto the switch. I would like to upgrade it to new version that can also support ssh connection but not sure which image to download from cisco. The switches are now live.
System image file is "flash:c2960-lanbase-mz.122-35.SE5/c2960-lanbase-mz.122-35.SE5.bin" cisco WS-C2960-24TC-L (PowerPC405) processor (revision H0) with 61440K/4088K
I met a strange problem after enabling flow-control in 2960s.my enviroment,
- 2 cisco 2960s 24ts-l have been created a stack - IOS is 12.2(58)se2 - all ports have been enabled flowcontrol receive dersied
via show flowcontrol, I can see each Gigabyte Port have been enabled "flowcontrol receive desired" but, when I do the following tests
- connect equallogic ps4000xv to the port 21, I found the status of port is "input flow-control is off"
- connect one server with Broadcom Gigabyte Network adapter, which has been enable TX ON RX ON, or Auto, the status of the port is still "input flow-control is off"
I guess, the port status should be ""input flow-control is on". Test them with another port, I got the same result. why?