Our customer is having C6513 running with 12.2(18)SXF15a . One of the module (ACE20-MOD-K9) got rebooted with following error:
Feb 22 10:41:41.155 GMT: %OIR-SP-3-PWRCYCLE: Card in module 6, is being power-cycled off (Reset - Module Reloaded During Download)Feb 22 10:41:41.183 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 6 set off (Reset - Module Reloaded During Download)Feb 22 10:41:53.686 GMT: %OIR-SP-3-PWRCYCLE: Card in module 6, is being power-cycled off (Module not responding to Keep Alive polling)Feb 22 10:41:53.686 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 6 set off (Module not responding to Keep Alive polling)
I have a Cisco WS-C6513 switch, with a couple of GBIC module cards in it. I am trying to display the part number (or model number) of the modules which are inserted into this module card. How to do that? I don't want to schedule down-time to pull the module(s) - just to read the label! :-)
This shows me info for the "module card": sh module 9 But this doesn't work: sh module 9/6
In my Cisco 3750 get rebooted and now the SFP module is not working.
It showing the following error message.
05:13:22: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP inte rface Gi1/0/26 05:13:22: %GBIC_SECURITY_CRYPT-4-ID_MISMATCH: Identification check failed for GB IC in port Gi1/0/26
What is the error message indicating and what is the solution for this.
I am on a call right now troubleshooting some latency issue. The CPU usage on the sup card is low. Don't see any drops or input errors. I am aware that the switch and its modules have capability limits. Is there command I can run which will tell me if any module is overloaded or if the fabric/backplane is over utilized?My chassis is WS-C6513 and sup card is WS-SUP720-3B.
Our Data Center Switch (5010) rebooted itself today, underneath the captured screen
NX5010-1(config-vlan)# Broadcast message from root (console) (Sun Feb 10 14:22:41 2013):
The system is going down for reboot NOW!
NX5010-1# sh system reset-reason ----- reset reason for Supervisor-module 1 (from Supervisor in slot 1) --- 1) At 740938 usecs after Sun Feb 10 14:22:41 2013 Reason: Reset triggered due to HA policy of Reset Service: nohms hap reset Version: 5.0(2)N1(1)
We have observed WS-C4507R-E got rebooted while creating the L3 VLAN ( while No shut).Is there any known bug for below IOS ?cat4500-entservicesk9-mz.122-40.SG.bin,
One switch of our stack of 8 3750 have reboot with no reason. Nobody was in the room server when it appears et there was'nt any electrical problem at this moment.
I am new to this and have ran into some problems. I butilt up my router I was able from the rom> prompt to get my router to boot from SLOT0:xxxxx
Then I did the copy command copy slot0:xxxxxxx bootflash:xxxxxxxMy router starts up fine. I did all my configurations and did my copy run start when I was done. As this is what I do on my 3750s.
My router lost power and rebooted and I lost everything it did not boot up to my last configuration.How do I save my configurations when I am done ? How do I get it to boot from that configuration every time?
I have a pair of N7K's in vPC topology with some FEXs attached. I am looking into enabling Jumbo frame on the N7K as well as the FEX. I understand Jumbo frame is enabled globally by default.
My question is I have some interfaces in a port-channel that I need jumbo frame enabled. Do I enable it at the port-channel interface or at the physical interface ? and is the change disruptive to the network ? I am running NX-OS 6.0.2.
My question is wrt policy-based routing on my network. Our switch is a 3560G 24PS running Adv Ip Services image. It is connected to an 1841 and an 1811 each with a dual-wan connection . The 3560 defines 6 vlans and we are using PBR to route some vlans via the 1841 and some vlans via the 1811.
From a client on one vlan a traceroute to a client on another vlan goes through the 1811 before being routed back to the 3560. Is it possible to use PBR to detect traffic that is destined for another vlan on the same switch and then route it directly?
I have a remote 3G Cisco router (Cisco 819) that occastionally drops it's EzyVPN and the local guys just reboot the device so when I log on and check the logs it is empty. My syslog server shows very little, can I keep the logs locally or up the logging to the syslog server?
I am having some issues on my network and i think i have narrowed them down to a single switch.
On this switch the following logs can be seen 2147482407 05-May-2012 15:40:54 Informational %AAA-I-CONNECT: New http connection for user admin, source 10.0.5.135 destination 10.0.5.172 ACCEPTED 2147482431 05-May-2012 09:03:31 Warning %STP-W-PORTSTATUS: g13: STP status Forwarding 2147482432 05-May-2012 09:03:01 Informational %LINK-I-Up: g13 [code]......
All other switches are OK and do not show anything in their logs. I am trying to figure out what could be going wrong. Spanning tree is enabled on all switches. The switch tihs is happening on, ends in the ip 172 and is where all building cables connect to. They also connect to 174. I have attached an image of the infrastructure so you can visually see what i mean.
May 16 12:45:09.000: %C4K_RKNOVA-4-INVALIDTOKENEXPIRED: STANDBY: Suppressed 302 times)Expired token 16490 in the invalid token list (NumEntries: 6) of type IrmPortId other id == 4294967287
May 16 12:45:09.000: %C4K_RKNOVA-4-INVALIDTOKENEXPIRED: STANDBY: Suppressed 302 times)Expired token 16490 in the invalid token list (NumEntries: 6) of type IrmPortId other id == 4294967287
It looks like both my HSRP Interfaces (VLAN 600 & 700) cycle through standby --> active ---> speak continuously on one of the two switches. What can be causing this?
*May 4 06:41:24.883: %HSRP-5-STATECHANGE: Vlan700 Grp 0 state Speak -> Standby *May 4 06:41:33.671: %HSRP-5-STATECHANGE: Vlan700 Grp 0 state Standby -> Active *May 4 06:41:33.671: %HSRP-5-STATECHANGE: Vlan700 Grp 0 state Active -> Speak *May 4 06:41:34.251: %HSRP-5-STATECHANGE: Vlan700 Grp 0 state Speak -> Standby *May 4 06:41:47.691: %HSRP-5-STATECHANGE: Vlan700 Grp 0 state Standby -> Active *May 4 06:41:47.703: %HSRP-5-STATECHANGE: Vlan700 Grp 0 state Active -> Speak
I have got a l2 link of 512 kbps from two different ISP. I want to aggegrate the bandwidth of this connection so that I can feel like having 1 mbps connection. I am not actually talking about load balancing, but bandwidth/link aggegration. Can we have the solution of failover with different vlan from different isp ? Can we be able to make the link as a single link.
I am not getting interface up/down logs in my switch console through show logging command. Switch model cisco WS-C4506-E and IOS :- cat4500e-ipbasek9-mz.122-53.SG3.bin. I have done below mention configurations, we can't configure logging level beyond informational. [code]
We are getting some error logs on Nexus VDC,as follows:2012 Nov 23 08:49:11 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 6 times 2012 Nov 23 08:50:21 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 7 times 2012 Nov 23 08:49:11 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 6 times2012 Nov 23 08:50:21 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 7 times.
We use C2950G switches with IOS 12.1(22)EA12 . Switches are set up to send logs to a server (informationnal level). On this server, we receive many of logs from those switches, but none about interfaces errors (even if interfaces statistics show interfaces errors). On C3548 switches it's work fine.How should I be sure the set up of switches is correct ? Why do I never receive messages as %LINK-4-ERROR:[char] is experiencing errors ?
Below memory status alerts of are seen on our syslog server for Nexus 7K switch(Default VDC).
PLATFORM-2-MEMORY_ALERT_RECOVERED: Memory Status Alert : CRITICAL ALERT RECOVERED PLATFORM-2-MEMORY_ALERT_RECOVERED: Memory Status Alert : MINOR ALERT RECOVERED PLATFORM-2-MEMORY_ALERT_RECOVERED: Memory Status Alert : SEVERE ALERT RECOVERED
Memory threshold Not created on Nexus. Can we ignore this alert or does it impact our current network traffic?
Aug 12 15:30:57.127 IST: %ENVIRONMENT-3-RPS_FAILED: Faulty internal power supply detected Aug 12 15:31:02.175 IST: %ENVIRONMENT-3-RPS_FAILED: Faulty internal power supply detected Aug 12 15:31:08.219 IST: %ENVIRONMENT-3-RPS_FAILED: Faulty internal power supply detected Aug 12 15:31:10.239 IST: %ENVIRONMENT-3-RPS_FAILED: Faulty internal power supply detected
there is no error messages related to PSU in "show env all " log .
here is show version - ------------------ show version ------------------
Cisco Internetwork Operating System Software IOS (tm) C2950 Software (C2950-I6K2L2Q4-M), Version 12.1(22)EA13, RELEASE SOFTWARE (fc2) Technical Support: [URL] Copyright (c) 1986-2009 by cisco Systems, Inc. [Code] ....
We are getting some error logs on Nexus switch 7K.
Loggs: ---------- 2012 Oct 30 22:36:07 SWITCH %CMPPROXY-STANDBY-2-LOG_CMP_UP: Connectivity Management processor(on module 6) is now UP 2012 Oct 30 22:36:40 SWITCH %SYSMGR-2-GSYNC_SNAPSHOT_SRVFAILED: Service "ipqosmgr" on active supervisor failed to sto re its snapshot (error-id 0x40480005). 2012 Oct 30 22:36:40 SWITCH %SYSMGR-2-STANDBY_BOOT_FAILED: Standby supervisor failed to boot up. 2012 Oct 30 22:36:42 SWITCH %PLATFORM-2-MOD_REMOVE: Module 6 removed (Serial number JAF1550ATBR) 2012 Oct 30 22:42:08 SWITCH %BOOTVAR-5-NEIGHBOR_UPDATE_AUTOCOPY: auto-copy supported by neighbor supervisor, starting
i have a cisco router (3900 series) and a add on module (4 x 1 Gig port module). For some reason i cant seem to port channel them and cant do routing (can set an ip address on those ports). I can do port channel and routing on on-board ports. Do i have to enable any commands to do this ?
we have 4 department Finance, Marketing, HR, contracts. All are in different subnet. We need to install a single DHCP server to provide IP for all subnets.
We have one Layer 3 switch Cisco WS-C6513-E; Windows server 2003 DHCP server.
Was wondering if anyone has ever hot ADDED, not swapped, an expansion module in a 5548up. Is a switch reboot required?I looked at the H/W install guide and it does not mention anything.
My C6506 USING ws-sup720-3B, i upgrade the IOS to the latest release of 12.2(33) SXJ1 IOS version. After upgrade and reload the machine got one module cannot be detect..WS-X6416-GE-MT, 16 port 1000mb MTRK ethernet module. The version of this are:
-HW 1.0 -FW 5.3 (1)1 -SW 8.5 (0.46) RFW
Question 1: Any tools available on cisco to check out the hardware/software compabiity feature?
Question 2: Any release note, compability matrix table etc resources.
Recently we ha a Nexus 7010 with a module frozen that was OIR (Online Remote and Insert) but do not work until reload the Nexus 7k.The command "show tech-support" has the following:
Can the encryption module (DES/ 3DES/AES/SSL VPN Encrytion/compression) for Cisco Router 3845 able to support the external connection from other high end router, for example cisco 7200? What is the maximum bandwidth, load and concurrent connection it can support?