Cisco Switching/Routing :: Getting Continuous Logs On 4500 Switch?
May 15, 2013
I am getting continous logs on my 4507 Switch :
May 16 12:45:09.000: %C4K_RKNOVA-4-INVALIDTOKENEXPIRED: STANDBY: Suppressed 302 times)Expired token 16490 in the invalid token list (NumEntries: 6) of type IrmPortId other id == 4294967287
May 16 12:45:09.000: %C4K_RKNOVA-4-INVALIDTOKENEXPIRED: STANDBY: Suppressed 302 times)Expired token 16490 in the invalid token list (NumEntries: 6) of type IrmPortId other id == 4294967287
does it lead to high CPU utilisation as well ??
View 1 Replies
ADVERTISEMENT
May 4, 2012
I am having some issues on my network and i think i have narrowed them down to a single switch.
On this switch the following logs can be seen
2147482407 05-May-2012 15:40:54 Informational %AAA-I-CONNECT: New http connection for user admin, source 10.0.5.135 destination 10.0.5.172 ACCEPTED
2147482431 05-May-2012 09:03:31 Warning %STP-W-PORTSTATUS: g13: STP status Forwarding
2147482432 05-May-2012 09:03:01 Informational %LINK-I-Up: g13
[code]......
All other switches are OK and do not show anything in their logs. I am trying to figure out what could be going wrong. Spanning tree is enabled on all switches. The switch tihs is happening on, ends in the ip 172 and is where all building cables connect to. They also connect to 174. I have attached an image of the infrastructure so you can visually see what i mean.
View 5 Replies
View Related
Feb 7, 2013
I am not getting interface up/down logs in my switch console through show logging command. Switch model cisco WS-C4506-E and IOS :- cat4500e-ipbasek9-mz.122-53.SG3.bin. I have done below mention configurations, we can't configure logging level beyond informational. [code]
View 4 Replies
View Related
Nov 21, 2012
We are getting some error logs on Nexus VDC,as follows:2012 Nov 23 08:49:11 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 6 times 2012 Nov 23 08:50:21 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 7 times 2012 Nov 23 08:49:11 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 6 times2012 Nov 23 08:50:21 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 7 times.
View 1 Replies
View Related
Oct 29, 2012
We are getting some error logs on Nexus switch 7K.
Loggs:
----------
2012 Oct 30 22:36:07 SWITCH %CMPPROXY-STANDBY-2-LOG_CMP_UP: Connectivity Management processor(on module 6) is now UP
2012 Oct 30 22:36:40 SWITCH %SYSMGR-2-GSYNC_SNAPSHOT_SRVFAILED: Service "ipqosmgr" on active supervisor failed to sto
re its snapshot (error-id 0x40480005).
2012 Oct 30 22:36:40 SWITCH %SYSMGR-2-STANDBY_BOOT_FAILED: Standby supervisor failed to boot up.
2012 Oct 30 22:36:42 SWITCH %PLATFORM-2-MOD_REMOVE: Module 6 removed (Serial number JAF1550ATBR)
2012 Oct 30 22:42:08 SWITCH %BOOTVAR-5-NEIGHBOR_UPDATE_AUTOCOPY: auto-copy supported by neighbor supervisor, starting
[code]....
View 8 Replies
View Related
Dec 14, 2011
Why Cisco 4500 R switch PBR tracking Command not working , I found just route-map next-hop ?
View 3 Replies
View Related
Jul 22, 2012
We are going to be rolling the 4500 switches out and I wanted to know more about how to use the wireshark featue. Any documentation on how to use this?
View 2 Replies
View Related
Dec 2, 2012
We've ordered a 4500 core switch and 4948 Server Farm switch for our client, but the switch box does not include a IOS image CD or anything related to IOS image and now the client is asking us why is this item missing as the IOS
-S45UK9-32-1502SGCAT4500e SUP7e Universal Crypto Image
-S49IPB-12253SGCisco CAT4900 IOS IP BASE W/O CRYPTO
View 4 Replies
View Related
Jun 2, 2013
i configure the uplinks as etherchannel, i configure two svi interface on core switch int vlan 51(192.168.51.1) and int vlan 50(192.168.50.0) for this two svi int i configured two dhcp pool , when any of the pc is requesting for dhcp add i am getting dhcp request failed/
View 7 Replies
View Related
Feb 24, 2013
I have a Cisco 4500. Recently some of the ports seem to have "died"/ will not supply Poe to phones. Some work for data only. Other do not work at all. The switch has been restarted, this made no difference.
View 2 Replies
View Related
Oct 16, 2012
is it possible to run a Catalyst 4500 as pure Layer 2 Switch, i.e. disabling "ip routing", but still managing the switch via Fa1, i.e. the defautl mgmtVrf vrf ?I tried the following:
!
no ip routing
!
interface FastEthernet1
ip vrf forwarding mgmtVrf
ip address 192.168.1.1 255.255.255.0
!
ip route vrf mgmtVrf 0.0.0.0 0.0.0.0 192.168.1.254
ip default-gateway 192.168.1.254
I was not able to reach the Switch even from the same subnet. Only after enabling ip routing I could manage the Switch. I haven't found any command to set ip default-gateway for a vrf. Any workaround to keep routing disabled, but still manageable via VRF?
View 3 Replies
View Related
Apr 1, 2013
We are facing cold start issue on 4500 series switch. The switch is restarting automatically almost weekly twice or thrice.As per show tech. output , there is "cold start log".Please find the attached logs for your reference.After time change , auto restart happening & am not found any log for power failure also.
View 6 Replies
View Related
Sep 19, 2012
How can I find out the firmware versions for IOS, modules and components of Cisco catalyst 4500 series switch. I can see the firmware version of IOS in show version command but how can I find it out for the modules or components of the switch.
View 4 Replies
View Related
Oct 14, 2012
We have a 4500 series switch that is running around 39% cpu utilization but seems to be dragging a bit. I did a show platform health and GalChassisVp-review has a target of 3% but an actual of 17%. All other actual values were at or below target values. I then went to show platform cpu packet statistics and in the "Packets received by Packet Queue" all queue packet values at 5 sec, 1 min, 5 min and 1 hour avg were either 0 or 1 with the exception of Esmp - that averaged 351/377/317 and 313 respectively. I then checked show platform hardware acl input entries static and the entry type InputEsmpToCPU had a whopping 10121370 hit count. All other entry types were well under that number.
View 2 Replies
View Related
Apr 3, 2012
i am trying to configure my HP 420 access point. I have configure different SSID on it, This access point is connected to cisco 4500 switch, i have configure trunk on up link to access point.my problem is the client are not able to get an IP address form the correct vlan if i tagged the SSID to it.
in the following the output of show run int in cisco 4500 switch:
interface GigabitEthernet3/13
description ==== HP ACCess point ====
switchport trunk allowed vlan 99,130,132
switchport mode trunk
[code]....
View 1 Replies
View Related
Apr 24, 2012
I was checking some things on my Cisco 4500 and spot checking some of the ports. Using CNA it says it is at 10. The web browser to the switch says Full-duplex, 1000Mb/s, link type is auto, media type is 10/100/1000-TX on port 6i/18 The CNA says, so what would cause the difference?
View 3 Replies
View Related
Jun 4, 2012
switch catalyst 4500 with ios cat4500e-universal.SPA.03.02.00.XO.150-2.XO.bin. I need to configure modules 3 and 4 of supervision, the problem is that I need the 4-port module 3 are active but only the first turn on both the module 3 and the first port on the module 4. [code]
View 1 Replies
View Related
Oct 31, 2012
I have the attached setup. now i would like to limit my ftp transfer to 10 mb from a specific vlan to ftp server on the STM-4 (622) link. what would be the best way to limit ftp traffic to 10 mb .Video_Main#sh verCisco IOS Software, IOS-XE Software, Catalyst 4500 L3 Switch Software (cat4500e-UNIVERSAL-M), Version 03.02.00.SG RELEASE SOFTWARE (fc4)Technical Support:
[URL] Copyright (c) 1986-2011 by Cisco Systems, Inc.Compiled Tue 26-Apr-11 18:09 by prod_rel_team
Image text-base: 0x100A0994, data-base: 0x13CAB728
ROM: 15.0(1r)SG1Jawa Revision 7, Snowtrooper Revision 0x0.0x116
Video_Main uptime is 15 weeks, 3 days, 23 hours, 53 minutesSystem returned to ROM by power-onSystem restarted at 16:38:21 UTC Wed Nov 23 2011Running default software
License Information for 'WS-X45-SUP7-E' License Level: entservices Type: Permanent Next reboot license Level: entservices
cisco WS-C4506-E (MPC8572) processor (revision 8) with 2097152K/20480K bytes of memory.Processor board ID FOX1502GZHFMPC8572 CPU at 1.5GHz, Supervisor 7Last reset from PowerUp9 Virtual Ethernet interfaces204 Gigabit Ethernet interfaces10 Ten Gigabit Ethernet interfaces511K bytes of non-volatile configuration memory.
Configuration register is 0x2101
Video_Main#
View 6 Replies
View Related
Aug 15, 2012
I have seen links out there for a conversion tool to convert commands on a Catalyst type switch (6509) to newer IOS type switches(4500-e) switches but they all error out on me on a 404. Any link where I can get this conversion tool?
View 1 Replies
View Related
Aug 14, 2012
4500 switch is connected to 2960 switch.
4500 config
Vlan 10
name Data
It has ip helper configured that points to DHCP.From 4500 switch port - port x connects to 2960 port.Port x is configured as trunk between 4500 and 2960.
2960 config
vlan 10
name data
All user ports are configured under vlan 10 and as access ports.Port x is trunk port connected frpm 2960 to 4500 switch allowing vlan 1 and 10 only.This switch has no default gateway configured.
We connected user PC on 2960 switchports and they were able to get the IP from DHCP server and were able to access the network? My question is how users on 2960 switch are able to access the network without ip default-gateway configured on 2960 switch?
View 6 Replies
View Related
Jun 3, 2013
I have configured a SVI in my 4500 ( Sup 7-E 10GE,,,,,,and,,,,,cat4500e-universalk9.SPA.03.02.00.SG.150-2.SG.bin) switch and it is showing Down Down, because there were no active switch port in the vlan, I added one switch port to this vlan but this port also in the down state, so i added the SWITCH PORT AUTO STATE EXCLUDE command under this port, even after this also the SVI never came up, So i added one systen to the port so both the switch port and the SVI came up...So why SWITCH PORT AUTO STATE EXCLUDE command have no effect in this model of the switch..
View 4 Replies
View Related
Oct 31, 2011
we have a 4510r-e running 12.2(50)SG1 w/ various rj45 line cards and a 24 port glc card.at any given time, i see 10's of ports in 10/full.i go to the station, and find the station in 100/full or 1000/full.
i go to the switch w/ my fluke, connect it directly to the switch w/o any intermediate infrastructure except a 50cm cat6 patch cable.the fluke reports 1000/full, but THE SWITCH PORT REPORTS STILL 10/FULL.all ports are config'd 'speed auto' and 'duplex auto'.
the switch seems to be erroneously reporting 10/full.there are no errors logged on any of the ports and there is successful communications even when the station and switch port report different speeds.even though there are no errors logged nor reported by 'show int [port]' nor 'sho int count error' certain killer applications crash on some stations. (the applications are GHOST (which dumps disk images from a server to multiple stations) and NETOP (which i sused in a classroom to transmit an instructors screen to a room full of stations) both of which broadcast and/or multicast.all nodes involved in the above 2 applics are on the same vlan and same phyiscal subnet.
the ports which report 10/full vary and occur even when the above applics are not in use.the only way i found to clear this 10/full report is by either a hardware reset of the entire module or by unplugging the cable, the execute on the port shutdown, speed auto, no shutdown, reconnect cable.then it's just a matter of time until it pops back to 10/full in a few minutes,hours or days.
how to address the killer applic problems besides restructuring the whole net by defining separate vlan for each lab of 20 or so stations?
View 7 Replies
View Related
Dec 10, 2012
I have Nexus 7K installations in 2 locations. Both of them have multiple VDCs. In default VDC there are continous tacacs error message though tacacs is not configured. The requests are from various public IPs where thsi VDC is not exposed to Internet at all. What would be t he cause of it?
%AUTHPRIV-3-SYSTEM_MSG: pam_aaa:Authentication failed for user root from 195.2.219.2
2012 Dec 11 16:25:28 IDC-FBDTB-AMR2-CN7K-01 %AUTHPRIV-3-SYSTEM_MSG: pam_aaa:Authentication failed for user nagios from 67.78.206.226
- sshd[25797]
2012 Dec 11 16:25:34 IDC-FBDTB-AMR2-CN7K-01 %AUTHPRIV-3-SYSTEM_MSG: pam_aaa:Authentication failed for user nagios from 67.78.206.226
- sshd[25799]
[code]....
View 1 Replies
View Related
Apr 3, 2012
We are running a stack of 2 WS-C3750X-24S-E's with IOS version 12.2(58)SE2 and we are seeing continuous high processor utilization involving the hl3mm process. The stack is configured for PIM Sparse mode, with 2 upstream Nexus 5596'es acting as both RP candidates and as BSRs. The hl3mm process generally runs at about 19% but can spike up into the 60% range.Symptoms on the 3750X are spiking latency and sluggish CLI perfformance. I thought at first that we might be running into SDM limits, but the "show platform tcam utilization" show that we are far under the limits of the default SDM template. Performing the "show ip pim (vrf name) bsr-router" command freezes the system and takes 20-30 seconds to return results. Similiarly configured WS-C3750G-12S running 12.2(55)SE3 does not exhibit these same issues.
View 4 Replies
View Related
Apr 16, 2013
I have a remote 3G Cisco router (Cisco 819) that occastionally drops it's EzyVPN and the local guys just reboot the device so when I log on and check the logs it is empty. My syslog server shows very little, can I keep the logs locally or up the logging to the syslog server?
View 1 Replies
View Related
Feb 3, 2012
%SYSTEM_CONTROLLER-SP-3-ERROR: Error condition detected: TM_DATA_PARITY_ERROR Feb 2 10:57:09.602 EST: %SYSTEM_CONTROLLER-SP-3-EXCESSIVE_RESET: System Controller is getting reset so frequently
Cisco Internetwork Operating System Software
IOS (tm) s222_rp Software (s222_rp-IPSERVICES_WAN-M), Version 12.2(18)SXF15a, RELEASE SOFTWARE (fc1)
Technical Support: [URL]
Copyright (c) 1986-2008 by cisco Systems, Inc.
Compiled Mon 20-Oct-08 19:20 by kellythw
Image text-base: 0x40101040, data-base: 0x42951080
[code]....
View 1 Replies
View Related
May 3, 2012
It looks like both my HSRP Interfaces (VLAN 600 & 700) cycle through standby --> active ---> speak continuously on one of the two switches. What can be causing this?
*May 4 06:41:24.883: %HSRP-5-STATECHANGE: Vlan700 Grp 0 state Speak -> Standby
*May 4 06:41:33.671: %HSRP-5-STATECHANGE: Vlan700 Grp 0 state Standby -> Active
*May 4 06:41:33.671: %HSRP-5-STATECHANGE: Vlan700 Grp 0 state Active -> Speak
*May 4 06:41:34.251: %HSRP-5-STATECHANGE: Vlan700 Grp 0 state Speak -> Standby
*May 4 06:41:47.691: %HSRP-5-STATECHANGE: Vlan700 Grp 0 state Standby -> Active
*May 4 06:41:47.703: %HSRP-5-STATECHANGE: Vlan700 Grp 0 state Active -> Speak
View 1 Replies
View Related
Nov 18, 2012
I have got a l2 link of 512 kbps from two different ISP. I want to aggegrate the bandwidth of this connection so that I can feel like having 1 mbps connection. I am not actually talking about load balancing, but bandwidth/link aggegration. Can we have the solution of failover with different vlan from different isp ? Can we be able to make the link as a single link.
View 2 Replies
View Related
Feb 22, 2010
Our customer is having C6513 running with 12.2(18)SXF15a . One of the module (ACE20-MOD-K9) got rebooted with following error:
Feb 22 10:41:41.155 GMT: %OIR-SP-3-PWRCYCLE: Card in module 6, is being power-cycled off (Reset - Module Reloaded During Download)Feb 22 10:41:41.183 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 6 set off (Reset - Module Reloaded During Download)Feb 22 10:41:53.686 GMT: %OIR-SP-3-PWRCYCLE: Card in module 6, is being power-cycled off (Module not responding to Keep Alive polling)Feb 22 10:41:53.686 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 6 set off (Module not responding to Keep Alive polling)
Code...
View 4 Replies
View Related
Sep 30, 2012
We use C2950G switches with IOS 12.1(22)EA12 . Switches are set up to send logs to a server (informationnal level). On this server, we receive many of logs from those switches, but none about interfaces errors (even if interfaces statistics show interfaces errors). On C3548 switches it's work fine.How should I be sure the set up of switches is correct ? Why do I never receive messages as %LINK-4-ERROR:[char] is experiencing errors ?
View 2 Replies
View Related
Mar 22, 2012
Below memory status alerts of are seen on our syslog server for Nexus 7K switch(Default VDC).
PLATFORM-2-MEMORY_ALERT_RECOVERED: Memory Status Alert : CRITICAL ALERT RECOVERED
PLATFORM-2-MEMORY_ALERT_RECOVERED: Memory Status Alert : MINOR ALERT RECOVERED
PLATFORM-2-MEMORY_ALERT_RECOVERED: Memory Status Alert : SEVERE ALERT RECOVERED
Memory threshold Not created on Nexus. Can we ignore this alert or does it impact our current network traffic?
View 5 Replies
View Related
Aug 15, 2011
I m getting below error messages in show logs -
Aug 12 15:30:57.127 IST: %ENVIRONMENT-3-RPS_FAILED: Faulty internal power supply detected
Aug 12 15:31:02.175 IST: %ENVIRONMENT-3-RPS_FAILED: Faulty internal power supply detected
Aug 12 15:31:08.219 IST: %ENVIRONMENT-3-RPS_FAILED: Faulty internal power supply detected
Aug 12 15:31:10.239 IST: %ENVIRONMENT-3-RPS_FAILED: Faulty internal power supply detected
there is no error messages related to PSU in "show env all " log .
here is show version -
------------------ show version ------------------
Cisco Internetwork Operating System Software
IOS (tm) C2950 Software (C2950-I6K2L2Q4-M), Version 12.1(22)EA13, RELEASE SOFTWARE (fc2)
Technical Support: [URL]
Copyright (c) 1986-2009 by cisco Systems, Inc.
[Code] ....
View 8 Replies
View Related
Dec 2, 2011
How i can transfer the router logs to email address.Wev are using the router 2600.
View 5 Replies
View Related