Cisco Switching/Routing :: Memory Status Alert Logs On Nexus 7K?
Mar 22, 2012
Below memory status alerts of are seen on our syslog server for Nexus 7K switch(Default VDC).
PLATFORM-2-MEMORY_ALERT_RECOVERED: Memory Status Alert : CRITICAL ALERT RECOVERED
PLATFORM-2-MEMORY_ALERT_RECOVERED: Memory Status Alert : MINOR ALERT RECOVERED
PLATFORM-2-MEMORY_ALERT_RECOVERED: Memory Status Alert : SEVERE ALERT RECOVERED
Memory threshold Not created on Nexus. Can we ignore this alert or does it impact our current network traffic?
We are getting some error logs on Nexus VDC,as follows:2012 Nov 23 08:49:11 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 6 times 2012 Nov 23 08:50:21 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 7 times 2012 Nov 23 08:49:11 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 6 times2012 Nov 23 08:50:21 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 7 times.
We are getting some error logs on Nexus switch 7K.
Loggs: ---------- 2012 Oct 30 22:36:07 SWITCH %CMPPROXY-STANDBY-2-LOG_CMP_UP: Connectivity Management processor(on module 6) is now UP 2012 Oct 30 22:36:40 SWITCH %SYSMGR-2-GSYNC_SNAPSHOT_SRVFAILED: Service "ipqosmgr" on active supervisor failed to sto re its snapshot (error-id 0x40480005). 2012 Oct 30 22:36:40 SWITCH %SYSMGR-2-STANDBY_BOOT_FAILED: Standby supervisor failed to boot up. 2012 Oct 30 22:36:42 SWITCH %PLATFORM-2-MOD_REMOVE: Module 6 removed (Serial number JAF1550ATBR) 2012 Oct 30 22:42:08 SWITCH %BOOTVAR-5-NEIGHBOR_UPDATE_AUTOCOPY: auto-copy supported by neighbor supervisor, starting
One of our Nexus 7000 modules failed and generated the status below. Could this possibly be a hardware issue?
# show module Mod Ports Module-Type Model Status --- ----- ----------------------------------- ------------------ ---------- 1 0 10 Gbps Ethernet XL Module powered-dn Mod Power-Status Reason --- ------------ --------------------------- 1 powered-dn Unable to power up card (Power_OK not set)
I have a doubt about upgrading Memory in Redundant Supervisor Modules Nexus 7K18, i read the Cisco Nexus 7000 Series Hardware Installation and Reference Guide, and the process for upgrading the memory in redundant supervisors do not says that i can have a lose of service, but it also says that both supervisor modules must have the same amount of memory for redundancy to work;If the switch has two supervisor modules, both must have the same amount of memory. If you upgrade the standby supervisor module to 8 GB of memory, you must then switch the active supervisor to standby and upgrade the new standby supervisor to 8 GB of memory.
OK, so just mooching around in the pages of my switch, a 24 port switch and it has in the logs:
268InfoMay 15 22:43:51NIMInterface 26 is Link Down 269InfoMay 15 22:43:51NIMInterface 26 is Link Down 270InfoMay 15 22:43:51NIMevent(39),intf(26),component(2), on non-existent interface
Now, correct me if I`m wrong but my switch only has 24 ports and two of those (23 and 24) are dual personality jobbies!?Where the hell is port 26? Where did it come from? and why did it need to show up only for the switch to realise that it doesn`t really exist?
I have a few new ASR 1001s throwing false environmental alerts.According to the logs, the inlet temp is in excess of 100 degrees C.When I telnet to the routers, they're well within tolerance (30-32C),Running 15.1(1)S and bug toolkit shows no related issues or caveats.
We are using almost 10 Nexus 5k in our DC currently we are getting same error logs in all Nexus 5k." ntpd[4746]: ntp:time reset +0.279670 s " ,Is it major error or just for reset time?
We are facing issue of continous packet discards On nexus4001L link (int po2) to Nexus5020 switch. Nexus4001L is installed in IBM blade center server and we have FCOE enabled in this setup. [code]
I have been tasked to replace the existing Cat 6500 and 3750 switches by Nexus 7000 and Nexus 2000.I was told initially my boss plans to get 2 x Nexus 7000 and then eventually blow up to 4 x Nexus 7000s.For Nexus, is there a list of tasks / points that i need to consider for building the initial design?
Can i just link the Nexus 7000 like the following?
N7k-A ========= N7k-B | | lots of N2ks lots of N2ks
we are planning a Nexus datacenter project with this layout:Our experiences with Nexus switches are not so large until now and the manuals are very extensive.Both N5K´s should be connected directly with all 4 N2K switches. I did not find a layout like this in the manuals. Only a design,where only 2 N2K are connected to one N5K, with this fex config:Now I´m not sure if it is right to make a config like this with the same slots and fex´s or with different slots and fex´s.
I have a remote 3G Cisco router (Cisco 819) that occastionally drops it's EzyVPN and the local guys just reboot the device so when I log on and check the logs it is empty. My syslog server shows very little, can I keep the logs locally or up the logging to the syslog server?
I am having some issues on my network and i think i have narrowed them down to a single switch.
On this switch the following logs can be seen 2147482407 05-May-2012 15:40:54 Informational %AAA-I-CONNECT: New http connection for user admin, source 10.0.5.135 destination 10.0.5.172 ACCEPTED 2147482431 05-May-2012 09:03:31 Warning %STP-W-PORTSTATUS: g13: STP status Forwarding 2147482432 05-May-2012 09:03:01 Informational %LINK-I-Up: g13 [code]......
All other switches are OK and do not show anything in their logs. I am trying to figure out what could be going wrong. Spanning tree is enabled on all switches. The switch tihs is happening on, ends in the ip 172 and is where all building cables connect to. They also connect to 174. I have attached an image of the infrastructure so you can visually see what i mean.
May I know how to monitor temperature status of below device by SNMP.How to find the exact oid of those devices? I can only find the mib file of Nexus 5000 at url...Cisco Nexus 5010PCisco UCS 6120XP Cisco ASR 1002F
According to my boss every 3 to 4 months he has to restart our 2821 with a 16-esw module installed because of a low memory issue dealing with CEF. Here is the exact error message.
%% Low on memory; try again laterJun 8 11:18:51.777: %FIB-2-FIBDOWN: CEF has been disabled due to a low memory condition. It can be re-enabled by configuring "ip cef [distributed]" Jun 8 11:19:51.823: %FIB-2-FIBDOWN: CEF has been disabled due to a low memory condition. It can be re-enabled by configuring "ip cef [distributed]" %%
Low on memory; try again later %% Low on memory; try again later %% Low on memory; try again later
Jun 8 11:20:51.868: %FIB-2-FIBDOWN: CEF has been disabled due to a low memory condition. It can be re-enabled by configuring "ip cef [distributed]" Jun 8 11:21:51.914: %FIB-2-FIBDOWN: CEF has been disabled due to a low memory condition. It can be re-enabled by configuring "ip cef [distributed
Today, one of our Cisco 3750 got unmanaged from NOC, we were able to ping the switch, also, traffic was flowing fine but not able to telnet or local login.On trying to login through console following messages were coming:
%% Low on memory; try again later %% Low on memory; try again later %% Low on memory; try again later %% Low on memory; try again later %% Low on memory; try again later %% Low on memory; try again later
[code].....
We given power on reset, after which we were able to login switch again. I wanted to know the actual reason behind it and if there is any other way to recover switch other than power reset.?
May 16 12:45:09.000: %C4K_RKNOVA-4-INVALIDTOKENEXPIRED: STANDBY: Suppressed 302 times)Expired token 16490 in the invalid token list (NumEntries: 6) of type IrmPortId other id == 4294967287
May 16 12:45:09.000: %C4K_RKNOVA-4-INVALIDTOKENEXPIRED: STANDBY: Suppressed 302 times)Expired token 16490 in the invalid token list (NumEntries: 6) of type IrmPortId other id == 4294967287
It looks like both my HSRP Interfaces (VLAN 600 & 700) cycle through standby --> active ---> speak continuously on one of the two switches. What can be causing this?
*May 4 06:41:24.883: %HSRP-5-STATECHANGE: Vlan700 Grp 0 state Speak -> Standby *May 4 06:41:33.671: %HSRP-5-STATECHANGE: Vlan700 Grp 0 state Standby -> Active *May 4 06:41:33.671: %HSRP-5-STATECHANGE: Vlan700 Grp 0 state Active -> Speak *May 4 06:41:34.251: %HSRP-5-STATECHANGE: Vlan700 Grp 0 state Speak -> Standby *May 4 06:41:47.691: %HSRP-5-STATECHANGE: Vlan700 Grp 0 state Standby -> Active *May 4 06:41:47.703: %HSRP-5-STATECHANGE: Vlan700 Grp 0 state Active -> Speak
I have got a l2 link of 512 kbps from two different ISP. I want to aggegrate the bandwidth of this connection so that I can feel like having 1 mbps connection. I am not actually talking about load balancing, but bandwidth/link aggegration. Can we have the solution of failover with different vlan from different isp ? Can we be able to make the link as a single link.
We recently connected a RPS 2300 to our switch WS-C3750G-48PS-E with IOS c3750-ipservicesk9-mz.122-53.SE2.bin.However i do not see any RPS details in the"show env" output.I believe i should get the RPS Name and its Serial and the port number in the output, but i am not finding it in the output. I did reload the switch but still couldnot get this udpated.
We had to transport one of our 4948 10 GE to another Data Centre and when we got it there and tried to power up its System Status LED was red and we cannot even get console to the device.
We can try to see if the switch is completely dead and needs replacing or is there something we can do to get it back up and running again?
have 3 Catalyst 3750 in same stack, the IOS version is 12.2(53)SE2. Today we can not telnet/ssh to this switch, but ping is ok, and switch function is ok. I try to access the console port, it show "low on memory, try again later". After I reboot the master switch in the stack, the master switch change to another switch, then I can telnet/ssh to this switch. I check the Ciscoworks server syslog report, there are many MAC address flapping error message, and I beleive the MAC address flapping occured before several weeks. ( the G2/0/15 & G3/0/15 is connect to a VMware ESX server and the EtherChannel config mismatch with this Catalyst 3750 switch ) How to mention the root cause of the "low on memory" problem and what is the abnormal memory usage ( free memory percentage below ?% )?
i have a Ws-C3550-24-Emi switch and i need to upgrade its flash memory to 32Mb. I couldn't find any documents in cisco website about the memory upgrade guideline. Possible to upgrade this switch to 32Mb? If so, what's the max of memory i can upgrade? and the part number for this type of memory?
I have a bootflash in 4507R with the size of 60MB. I upgraded the ios from cat4500-ipbasek9-mz.122-37.SG1.bin (12.8MB Size) to cat4500-entservices-mz.122-37.SG1.bin (13.8 MB SIZE) and deleted the previous IOS.But previous IOS is still getting shown in sh bootflash: command. Furthermore, dir bootflash: commands shows there is only one IOS , which is running. How I can free the space from bootflash , as I again have to upgrade the another new IOS ( of 16MB), which I tried through solarwinds tftp and couldn't upload successfully because of its limitation. Now, If I try to upload the new IOS through FTP, it gives me memory space error. How I can free the space captured by old IOS and also how I can delete the 3rd unknown entry of IOS (shown below output of commands)?
I have a 3560 connected to an edge device and I keep etting this error. I have turned off proxy arp and turned off ip cef under the interface, however I lot connectivity to the internet when I did that. I can't seem to find any documentation on this error. I understand what it means, I just don't know how to resolve the problem.
I have a 3560 connected to an edge device and I keep etting this error. I have turned off proxy arp and turned off ip cef under the interface, however I lot connectivity to the internet when I did that. I can't seem to find any documentation on this error. [code]
I am not getting interface up/down logs in my switch console through show logging command. Switch model cisco WS-C4506-E and IOS :- cat4500e-ipbasek9-mz.122-53.SG3.bin. I have done below mention configurations, we can't configure logging level beyond informational. [code]
Our customer is having C6513 running with 12.2(18)SXF15a . One of the module (ACE20-MOD-K9) got rebooted with following error: Feb 22 10:41:41.155 GMT: %OIR-SP-3-PWRCYCLE: Card in module 6, is being power-cycled off (Reset - Module Reloaded During Download)Feb 22 10:41:41.183 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 6 set off (Reset - Module Reloaded During Download)Feb 22 10:41:53.686 GMT: %OIR-SP-3-PWRCYCLE: Card in module 6, is being power-cycled off (Module not responding to Keep Alive polling)Feb 22 10:41:53.686 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 6 set off (Module not responding to Keep Alive polling)
We use C2950G switches with IOS 12.1(22)EA12 . Switches are set up to send logs to a server (informationnal level). On this server, we receive many of logs from those switches, but none about interfaces errors (even if interfaces statistics show interfaces errors). On C3548 switches it's work fine.How should I be sure the set up of switches is correct ? Why do I never receive messages as %LINK-4-ERROR:[char] is experiencing errors ?