Cisco Switching/Routing :: 3750 Router Lost Power And Rebooted
May 14, 2012
I am new to this and have ran into some problems. I butilt up my router I was able from the rom> prompt to get my router to boot from SLOT0:xxxxx
Then I did the copy command copy slot0:xxxxxxx bootflash:xxxxxxxMy router starts up fine. I did all my configurations and did my copy run start when I was done. As this is what I do on my 3750s.
My router lost power and rebooted and I lost everything it did not boot up to my last configuration.How do I save my configurations when I am done ? How do I get it to boot from that configuration every time?
View 1 Replies
ADVERTISEMENT
Mar 19, 2012
In my Cisco 3750 get rebooted and now the SFP module is not working.
It showing the following error message.
05:13:22: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP inte
rface Gi1/0/26
05:13:22: %GBIC_SECURITY_CRYPT-4-ID_MISMATCH: Identification check failed for GB
IC in port Gi1/0/26
What is the error message indicating and what is the solution for this.
View 1 Replies
View Related
Oct 2, 2012
One switch of our stack of 8 3750 have reboot with no reason. Nobody was in the room server when it appears et there was'nt any electrical problem at this moment.
View 4 Replies
View Related
Jun 9, 2013
I am receiving the following error on 3750 stack switches. have already verified the power status and found ok.
IOS used: Cisco IOS Software, C3750E Software (C3750E-UNIVERSALK9-M), Version 12.2(55)SE3, RELEASE SOFTWARE (fc1)
211540: Jun 10 10:45:17.935 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS: Switch 4's power stack has unbalanced power supplies
211541: Jun 10 10:46:18.045 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS:
[Code]....
View 1 Replies
View Related
Oct 31, 2012
I recently bought a bunch of cisco 3750-x switches. I configured them all and started deploying them. A day later, some of the switches started failing on me. When I connect the power cord to the AC main, the power supply module on the back shows "AC OK" LED Green but the "PS OK" LED shows Red. I started referring to the installation guide and it told me that "PS OK" LED turns RED when output has failed. Guessing this I checked with another power supply module that was working, but still I get the same LED indicators.The original power supply module works with other switches.IOS crash...?
View 5 Replies
View Related
May 2, 2013
I have lost the "ENABLE" password on my 3750 switch.
View 5 Replies
View Related
Apr 21, 2013
What will be the recommended connectivity of stack power cable in 6 number of 3750x switches ?
Is it similar to the stack cable ?
View 3 Replies
View Related
Oct 22, 2012
I am connecting power cable (series power cables) on 3750 stacks. i have connected them the same way the stack cables are connected i.e. fo rexample on a stack with 3 3750s:
1- fitst slot on fist switch connected the second slot last switch in the stack.
2- second slot/ port on the first switch to the first on second and seoncd on teh second switch to first on the third switch.
this how they are alway been stacked.Now, I need to connect power cables and I have followed the same method for stacks up to 4 switches. it seems that if a stack has more tham 4 switches, then the cabling will be dofferent!?I was wondering what will be on the cabling scheme for stacks more than 4 switches.
View 3 Replies
View Related
Dec 3, 2011
power supply problem...?Switch cisco WS-C3750-24P is showing "Unavail" from sh env all.Switch3750#sh env all FAN is OK,TEMPERATURE is OK,SW PID,Serial# Status Sys Pwr PoE Pwr Watts,Does it means that power supply 1 was removed? failed?,Do you know about another command to see more details?
View 3 Replies
View Related
Jan 16, 2012
I have 4 switches in a 3750-X stack.Here is the output from the stack why are the switches out of order and I'm not able to bring up switch 1 port 1.
switch 4 port 2 shows not connect it is I've checked the cables.
Power stack name: Powerstack-4
Stack mode: Power sharing
Switch 1:
Power budget: 695
Low port priority value: 22
High port priority value: 13
Switch priority value: 4
Port 1 status: Shut
Port 2 status: Connected
Neighbor on port 1: 0000.0000.0000
Neighbor on port 2: c471.fe84.e100
Switch 2:
Power budget: 713
Low port priority value: 21
High port priority value: 12
Switch priority value: 3
Port 1 status: Connected
Port 2 status: Connected
Neighbor on port 1: c471.fe85.3000
Neighbor on port 2: c471.fe80.2800
Switch 4:
Power budget: 697
Low port priority value: 19
High port priority value: 10
Switch priority value: 1
Port 1 status: Connected
Port 2 status: Not connected
Neighbor on port 1: c471.fe80.2800
Neighbor on port 2: 0000.0000.0000
Switch 3:
Power budget: 710
Low port priority value: 20
High port priority value: 11
Switch priority value: 2
Port 1 status: Connected
Port 2 status: Connected
Neighbor on port 1: c471.fe84.e100
Neighbor on port 2: c471.fe7f.eb00s
View 2 Replies
View Related
May 20, 2013
I want to know how much minimum power required for swicth catalyst 3750.I want to know cause in my building place, the power in unstable so it make my switch corrupt/damage even i add power consistancy....
How much amount power to the ups and ups to switch?
View 5 Replies
View Related
Feb 9, 2013
Our Data Center Switch (5010) rebooted itself today, underneath the captured screen
NX5010-1(config-vlan)#
Broadcast message from root (console) (Sun Feb 10 14:22:41 2013):
The system is going down for reboot NOW!
NX5010-1# sh system reset-reason
----- reset reason for Supervisor-module 1 (from Supervisor in slot 1) ---
1) At 740938 usecs after Sun Feb 10 14:22:41 2013
Reason: Reset triggered due to HA policy of Reset
Service: nohms hap reset
Version: 5.0(2)N1(1)
[code]....
View 2 Replies
View Related
May 20, 2013
We have observed WS-C4507R-E got rebooted while creating the L3 VLAN ( while No shut).Is there any known bug for below IOS ?cat4500-entservicesk9-mz.122-40.SG.bin,
View 4 Replies
View Related
Feb 22, 2010
Our customer is having C6513 running with 12.2(18)SXF15a . One of the module (ACE20-MOD-K9) got rebooted with following error:
Feb 22 10:41:41.155 GMT: %OIR-SP-3-PWRCYCLE: Card in module 6, is being power-cycled off (Reset - Module Reloaded During Download)Feb 22 10:41:41.183 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 6 set off (Reset - Module Reloaded During Download)Feb 22 10:41:53.686 GMT: %OIR-SP-3-PWRCYCLE: Card in module 6, is being power-cycled off (Module not responding to Keep Alive polling)Feb 22 10:41:53.686 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 6 set off (Module not responding to Keep Alive polling)
Code...
View 4 Replies
View Related
May 20, 2012
We have got 2 3750 switches in the stack which are connected to access switches with 2 uplink ports . each 1 uplink from each physical stack switch .
Due to some power issue our member switch got rebooted. After the reboot the access switches were not reachable through ping , but i was abe to see access switches in "show cdp neighbour" . Then i rebooted the master switch and member switch one after other . after which i was able to ping the access switches.
IOS Version : c3750-ipservices-mz.122-35.SE5.bin
View 3 Replies
View Related
Jun 13, 2012
recently bought a new Linksys EA3500 that is connected to my SB5120 cable modem. For two weeks it's been running smoothly but when my cable modem is in need of a power cycle.I power cycle both the router and modem but my connection is lost. it's after countless hours of messing with the two I'll get the connection back but I'm afraid it'll lose connection again, that and I fear I may have enabled bad options.
View 10 Replies
View Related
Sep 4, 2012
After stacking two 3750X switches, with four equal power-supply's, with StackWise and PowerStack , still got the next message every few hours %PLATFORM_ENV-1-FRU_PS_ACCESS: FRU Power Supply is not responding (gn4m-rt1p08-04-2)( note that the message revers to the second switch in the stack ) although the stackwise and powerstack on the switches is oke and are working correctly. !
Config : Stack-power in power-sharing mode/strict With CLI on the switch : All the power supply's and stack-power details, prio look OK.
Only: LMS prime /inventory/cisco-view/configure/power supply status result : some power supply's are marked as disabled.with the command > power supply 2 slot a off/on I manage to get the status back to "normal", but after a few hours some power supply's are again marked as "disabled".
Looks like SNMP en IOS difference from opinion.
Hardware
WS-C3750X-24S-S
C3KX-PWR-350WAC
Software
15.0(2)SE
C3750E-UNIVERSALK9-M
View 5 Replies
View Related
Apr 14, 2013
We have two switches of the same model (WS-C3560-48PS-S) that are not providing PoE. I'm trying to remotely determine what the cause of the issue is.
Here is some output.
Hostname#show power inlineAvailable:0.0(w) Used:0.0(w) Remaining:0.0(w)
Interface Admin Oper Power Device Class Max (Watts)--------- ------ ---------- ------- ------------------- ----- ----Fa0/1 auto off 0.0 n/a n/a 15.4Fa0/2 auto off 0.0 n/a n/a 15.4Fa0/3 auto off 0.0 n/a n/a 15.4Fa0/4 auto off 0.0 n/a n/a 15.4Fa0/5 auto off 0.0 n/a n/a 15.4Fa0/6 auto off 0.0 n/a n/a 15.4Fa0/7 auto off 0.0 n/a n/a 15.4Fa0/8 auto off 0.0 n/a n/a 15.4Fa0/9 auto off 0.0 n/a n/a 15.4Fa0/10 auto off 0.0 n/a n/a 15.4(code)
View 1 Replies
View Related
Feb 28, 2011
I have a 6500 chassis with 2 power supplies. At the moment I am using the default configuration:
power-redudancy mode redundant
The problem is that an inserted module is in "power deny" state due too insufficient power.
I know, that It's not a good idea to change into combined mode (loss of redundancy), but my customers requested this anyway.
So I will change to combined mode. So here's the 1 million dollar question: "Which modules will go into power deny, if one of my power supplies fails?"
The 6500 config guide states:
"Power supply is removed withredundancy disabled
• System log and syslog messages are generated.
• System power is decreased to the power capability of one supply.
• If there is not enough power for all previously powered-up modules, some modulesare powered down and marked as power-deny in the show power oper state field."
Well, do you know if there's any way to configure some kind of priority? E.g. I definetly don't want by 10Gig Module or WiSM module to be in power deny. Can i statically make sure, those module will be powered on for sure? Like: "power enable module slot_number" How is this calculated? Or is random?
View 3 Replies
View Related
Apr 4, 2012
In a stand alone 3750x switch configuration, can the secondary power supply only act as a redundant power supply (active/standby), or can it become a "pool" of power similar to power sharing mode for StackPower (somewhat active/active)? I understand there is no stack involved here but I'm curious if this functionality is possible.
View 1 Replies
View Related
Apr 6, 2011
I lost my power adapter for the WRT54G router. I have a 12V / 1000 mA brick adapter.
View 5 Replies
View Related
Jan 1, 2013
i have a cisco 1900 series router from the isp and we connect it the our router the rv042 small biz, and we have here a cisco catalyst 2950 switch with just default configuration connected to the hosts.
my problem is from time to time that the connection is lost there is no connection with the router and the only solution is to turn off and on the cisco 1900 router and the connection will be back.
do we need to configure the routers and switches? what do you need to configure?
View 2 Replies
View Related
Dec 14, 2012
clarify whether this statement found after table 4 of the Cisco 819 4G router data sheet truly means that there will be a power supply to support 48VDC in Q1 of 2013? Here is the statement:
"* Future external reference for 24V, 52V, and 72V DC for railway applications Q1CY2013"
Here is the data sheet source:
[URL]
I would want to power this router from a -48VDC plant, which is common at remote telecom sites.
View 1 Replies
View Related
Apr 22, 2013
I recently copied a configuration from a router 2800 to a 2900. After a power outage no one can connect outside of the network through the new router. Before the outage all was fine. I put back the old router and all is fine which eliminates any cable or switch error. I have the router totally disconnect. I notice the configuration is in place. My question is there any diagnostics that I can run to see if there is any hardware failure. It seems to boot up fine.
View 1 Replies
View Related
Apr 10, 2013
I have a peculiar issue with a router whering I get the message in the Show Environment as below.
sh environment out
Redundant Power System is not present.
SYS PS1 is present.
Type: AC
AUX(-48V) PS1 is absent.
Fan 1 OK
Fan 2 OK
Fan 3 OK
Fan Speed Setting: Normal
Alert settings:
Intake temperature warning: Enabled, Threshold: 55
Core temperature warning: Enabled, Threshold: 70 (CPU: 95)
Board Temperature: Normal
Internal-ambient temperature = 22, Normal
CPU temperature = 37, Normal
Intake temperature = 22, Normal
Voltage 1(3300) is Normal, Current voltage = 3300 mV
Voltage 2(5150) is Normal, Current voltage = 5210 mV
Voltage 3(2500) is High/Low, Current voltage = 2168 mV
[Code]...
View 4 Replies
View Related
Jun 30, 2012
Do I need the Universal image to perform stftp on a 3750 or 3750-X?
View 8 Replies
View Related
Feb 15, 2011
Any trouble with IOS XR licenses dissapearing after a power off ?I was able to add them correctly, but after the power off "show licenses" gives and empty message, but the logs states the licenses are already there.I'm working with a CRS-3 with IOS XR version 4.0.1.
View 1 Replies
View Related
Jun 27, 2011
I had lost power to my apartment and when everything came back on everything was working as normal...until about an hour later when my internet connection was sporadic at best. I called the ISP and they confirmed that the modem is fine. My other computers can connect to it via ethernet cable and wifi so it doesn't appear to be the router.
When I try to ping anything it seems to time out randomly.. (ran "ping Yahoo! -t1" and let it go for a while..times out every 10 requests or so).
I swapped out the ethernet cable but the LEDs on the NIC are Orange(Amber) for both cables. The wifi on the computer works fine. I reinstalled the driver for the NIC.
Computer:
Lenovo H320
Windows 7 64-bit
View 12 Replies
View Related
Feb 28, 2012
Within our small lan we have a core 3750, that handles our intervlan routing and is the core of the network. I recently looked into multicasting and set up a lab test with a 3550 with an EMI image and got the config to multicast to all vlans from one vlan, ready to go, at which point I found that our 3750 is IPBASE and doesn’t support multicasting. Currently upgrading the switch or image is not an option due to funding. My question is would it be possible and advisable to install our lab 3550 as a leg off the core, and in some way route multicasting traffic through that?I just cant get my head around the concept of having a core switch essentially routing all vlans, and then having another switch route the same vlan traffic again for multicasting to all the vlans again.
View 1 Replies
View Related
Jan 13, 2013
I've created a scenario using a 3750 cisco as core switch ad other 6 switch model 2900 in access level.my problem is this, the router is not a cisco router, and this router is not able to make NAT on more than one subnet.Into the core switch I've created 4 VLAN and I must to give internet access to 3 of them, 192.168.0.0/24 (vlan1), 172.16.0.0/24 (vlan2), 172.17.0.0/24 (vlan3).I've connected the switch to router via gigabit ethernet 0/1 and I've assigned to this interface ip address 192.168.10.2, the router ip address is 192.168.10.1, Switch ip default-gateway is router ip address 192.168.10.1, ip default route is 0.0.0.0 0.0.0.0 192.168.10.1 I've enabled ip routing feature and I've set no switchport feature to interface gigabit ethernet 0/1.From core switch I can ping router ip address but I can't make it from all other user, and the users not able to have internet access.
Below the switch configuration (only necessary strings)
version 12.1
no service pad
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
[code].....
View 6 Replies
View Related
Jun 26, 2011
So today all my remote offices can't connect to my server.
Looking as my asa 5510 in my main office it appears that the connections to the other offices is not working..So could this be from the power outage.I don't know how or why it would change no setting have been changed..
But staff at remote offices cannot connect to the server..The error they see is the primary dns is not responding.
View 2 Replies
View Related
Apr 3, 2013
1. How I can manage those devices, the Switch and the router? What is the BEST SOLUTION to manage this devices?
2. I want to monitor the traffic on this environment, how I can do it? How I can monitor the traffic from customer A, Customer B, and my own LAN traffic, in terms of bandwidth that has passed throught my devices? Is it possible to monitor on MY LAN, or I have to monitor from the EXTERNAL switch?
3. How I can limit the bandwidth? I was trying to configure it using access list, with policy-map, etc....and limit this on each interface. [code]
The interface does not support the specified policy configuration and/or parameter values.Assigning a policy map to the output side of an interface not supported.With I few reading, I could see that the SWITCH 3750 doesnt support this configs.My INTERNET LINK is 30 Mbps, the ports on the Switch (WS-C3750X-48P-L) are Gigabit Ethernet.How I can limit the bandwidth here? For example, How I can limit a interface to 3Mbps..I was thinking about this:
- Limit the interface to 10Mbps: speed 10
- and limit the interface with 30% of this speed: srr-queue bandwidth limit 30
Does this work for both UPLOAD and DOWNLOAD?When the packets passes that 3Mbps limitation, will they be droped?
View 28 Replies
View Related
Jan 20, 2012
If it's possible, how do you protect/block a unauthorized DHCP SOHO router with NAT form a Cisco 3750?
View 16 Replies
View Related