Cisco Switching/Routing :: Power Supply Error Switch 3750
Dec 3, 2011
power supply problem...?Switch cisco WS-C3750-24P is showing "Unavail" from sh env all.Switch3750#sh env all FAN is OK,TEMPERATURE is OK,SW PID,Serial# Status Sys Pwr PoE Pwr Watts,Does it means that power supply 1 was removed? failed?,Do you know about another command to see more details?
View 3 Replies
ADVERTISEMENT
Mar 17, 2013
We are getting below errors on our Cisco 4500 Switche PS after Power Down activity.
Switch1
------------------ show power detail ------------------
Power Fan Inline
Supply Model No Type Status Sensor Status
------ ---------------- --------- ----------- ------- -------
PS1 PWR-C45-4200ACV AC 4200W good good good
PS1-1 off
PS1-2 220V good
PS2 PWR-C45-4200ACV AC 4200W err-disable good good
PS2-1 220V good
PS2-2 220V good
*** Power Supplies of different type have been detected***
00:01:02: %C4K_CHASSIS-3-MIXINPOWERDETECTED: Power supplies in the chassis are of different types (AC/DC) or wattage(code)
View 1 Replies
View Related
Dec 8, 2012
I would like to check if it may be possible to hot-upgrade/swap the 4506E power supplies? Based on the configuration guide; I have summarized the steps as follows:
1. Switch has 2 existing power supplies to be upgraded
2. Remove right side/bay 2 power supply and install new power supply
3. At this point; the new power supply will be in err-disabled due to different power supplies on the switch
4. Remove the left side power supply and install new power supply
For item 4; during the removal of the old power supply in bay 1/left side and installation of the new power supply; I am wondering if the switch would lose power even though the new power supply is installed in bay 2?
View 1 Replies
View Related
Nov 6, 2012
I have a 3750x 48port POE switch that I installed a second power supply in. But it doesnt power on. Am I supposed to enable it in the switch somewhere? I've plugged it into a couple different outlets so I know that's not the problem.
View 4 Replies
View Related
Dec 3, 2011
I need a L2 switch with dual AC power supply and RJ45 uplink The optin I got was WS-C3560X-48T-L + C3KX-PWR-350WAC , but the problem is with uplink . There is no RJ45 1G uplink , there is only option for SFP uplink The another option was WS-C2960G-48TC-L , but there is no dual AC power supply option a good model ( Dual AC power supply , RJ 45 uplink ports (Gig) , with 48 port 100/1000 UTP)
View 3 Replies
View Related
Sep 4, 2012
After stacking two 3750X switches, with four equal power-supply's, with StackWise and PowerStack , still got the next message every few hours %PLATFORM_ENV-1-FRU_PS_ACCESS: FRU Power Supply is not responding (gn4m-rt1p08-04-2)( note that the message revers to the second switch in the stack ) although the stackwise and powerstack on the switches is oke and are working correctly. !
Config : Stack-power in power-sharing mode/strict With CLI on the switch : All the power supply's and stack-power details, prio look OK.
Only: LMS prime /inventory/cisco-view/configure/power supply status result : some power supply's are marked as disabled.with the command > power supply 2 slot a off/on I manage to get the status back to "normal", but after a few hours some power supply's are again marked as "disabled".
Looks like SNMP en IOS difference from opinion.
Hardware
WS-C3750X-24S-S
C3KX-PWR-350WAC
Software
15.0(2)SE
C3750E-UNIVERSALK9-M
View 5 Replies
View Related
Apr 4, 2012
In a stand alone 3750x switch configuration, can the secondary power supply only act as a redundant power supply (active/standby), or can it become a "pool" of power similar to power sharing mode for StackPower (somewhat active/active)? I understand there is no stack involved here but I'm curious if this functionality is possible.
View 1 Replies
View Related
Jan 16, 2012
I have 4 switches in a 3750-X stack.Here is the output from the stack why are the switches out of order and I'm not able to bring up switch 1 port 1.
switch 4 port 2 shows not connect it is I've checked the cables.
Power stack name: Powerstack-4
Stack mode: Power sharing
Switch 1:
Power budget: 695
Low port priority value: 22
High port priority value: 13
Switch priority value: 4
Port 1 status: Shut
Port 2 status: Connected
Neighbor on port 1: 0000.0000.0000
Neighbor on port 2: c471.fe84.e100
Switch 2:
Power budget: 713
Low port priority value: 21
High port priority value: 12
Switch priority value: 3
Port 1 status: Connected
Port 2 status: Connected
Neighbor on port 1: c471.fe85.3000
Neighbor on port 2: c471.fe80.2800
Switch 4:
Power budget: 697
Low port priority value: 19
High port priority value: 10
Switch priority value: 1
Port 1 status: Connected
Port 2 status: Not connected
Neighbor on port 1: c471.fe80.2800
Neighbor on port 2: 0000.0000.0000
Switch 3:
Power budget: 710
Low port priority value: 20
High port priority value: 11
Switch priority value: 2
Port 1 status: Connected
Port 2 status: Connected
Neighbor on port 1: c471.fe84.e100
Neighbor on port 2: c471.fe7f.eb00s
View 2 Replies
View Related
May 20, 2013
I want to know how much minimum power required for swicth catalyst 3750.I want to know cause in my building place, the power in unstable so it make my switch corrupt/damage even i add power consistancy....
How much amount power to the ups and ups to switch?
View 5 Replies
View Related
Sep 21, 2012
We have 3750-X's with dual power supplies. When one of them is disconnected the NMS/Netcool is not picking up the trap. What MIB is needed to monitor the power supplies?
View 1 Replies
View Related
Nov 20, 2011
The power supply on 6509 NEB A is not working with me . I have installed only one power supply on the box WS-CAC-3000W
It is showing me that "Input OK , Output fail " from the LCD
I tried with another WS-CAC-3000W , another power source but still same problem .
View 2 Replies
View Related
Mar 12, 2013
I would like to ask if how can we determine by mear physical inspection if the power supply of a CISCO2911/K9 router is AC, POE or DC? Do we have images of the actual spare power supply?
View 3 Replies
View Related
Jan 25, 2012
Just received our new 6513E chassis and I am setting it up in the lab for testing. For prod we would like to run..
1 maybe 2 6704 10 gig cards
3 - 5 6748 cards
1 6724 SFP card
Sup720 setup, possibly upgrading to Sup32's in a few years, Right now for power supplies, I am using 2 WS-CAC-2500W ,But I have to run the supplies in combined mode to get all of the cards online.What power supply should I be looking to purchase for this chassis ?
View 2 Replies
View Related
Nov 21, 2011
I have a 6509 box with the following modules:
View 4 Replies
View Related
Dec 12, 2012
While configuring PoE Ethernet EHWIC PoE modules with ISR G2 routers Cisco DCT gives a warning to select AC Power Supply with PoE ‘PWR-3900-POE’. Do we need to select the PoE power supply for Enhanced EtherSwitch SM PoE modules also (at present it does nt show any warnings)?
View 1 Replies
View Related
Apr 3, 2012
Currently I am using 1000W power supply in Cisco 4500 and I want to upgrade to 2800W power supply.My question is
1) Whether I have to change the power cord while upgrading power supply
2)Whether power cord comes along with the Power Supply while ordering from Cisco
View 1 Replies
View Related
Sep 3, 2012
I was wondering if there was a way to disable the RPS in a 3825? When I do a Sho Env All I get the following;
Redundant Power System is present.
RPS is in standby state
Redundant Power System is present.
RPS is in standby state
How ever there is no RPS in the system. At least not that I know of. There is only one power supply.
View 4 Replies
View Related
Dec 14, 2012
clarify whether this statement found after table 4 of the Cisco 819 4G router data sheet truly means that there will be a power supply to support 48VDC in Q1 of 2013? Here is the statement:
"* Future external reference for 24V, 52V, and 72V DC for railway applications Q1CY2013"
Here is the data sheet source:
[URL]
I would want to power this router from a -48VDC plant, which is common at remote telecom sites.
View 1 Replies
View Related
May 22, 2013
while the 3560 switch is running? Is it hot-pluggable?
WS-C3560X-48P is the switch and I would be adding a C3KX-PWR-1100WAC
View 1 Replies
View Related
Jul 11, 2012
Looking at the specs for the 3750 power supply - is the WS-C3750X-48P-S model with the 715W power supply referring to the amount for both power supplies per switch or just one power supply per switch? Meaning, is the 715 a accumulative number or, just the watts of one power supply. I would like to purchase a 3750x PoE switch with redundant power supplies. If this model is not the correct one?give me the model that offers 48 port PoE with redundant power supplies?
View 6 Replies
View Related
Dec 23, 2012
I was wondering if I am able to add a redundant power supply to an asr 1001 router that is in production without losing connectivity or causing any diruption to the Users - is it hotswappable?
View 1 Replies
View Related
May 9, 2013
can I plug power supply from 4500 to 6500? more specifically we have power supply PWR-C45-1300ACV. And we need to place some power supply to 6500, which has only one active module. So 1300 should be enough for it. But we dont know if they are physically compatible, if it is possible to plug. I didnt find this power supply to be officially?
View 4 Replies
View Related
Apr 6, 2012
Having a strange issue here with an 7606-s chassis equipped with two sup720's, and two regular line cards. There is only one power supply, PWR-2700-AC. I recently builded this setup and powered it on last week for the first time. It ran fine for about 20 minutes while suddenly the chassis powered down.
I've checked the back of the chassis and noticed that the power supply had it's 'input ok' and 'power fail' led lit. I toggled the power switch and waited half an hour to power it on again. This time only 1 minute of joy. My first idea was the PSU due to the power fail led so I had it swapped by the supplier for another. Unfortunately, when I powered it on today, it didn't change a thing, still unexpected power downs.
So I've checked the following documentation: [URL] and followed the suggestion to power the chassis on without any modules in the slots. So I did that and it ran for 8 minutes only. However, the fan tray did respond properly when I removed the small thermal module in the upper right by increasing the fans to full speed.
Following above documentation, it points to the chassis (there is not much left). Now the real question comes, isn't there anything else that could be the cause of this?
View 1 Replies
View Related
Jul 21, 2012
When quoting a Catalyst 3750X with PoE (WS-C3750X-48P-E) the Dynamic Configurator Tool allows to include as the secondary power supply option the Catalyst 3K-X 350W AC Secondary Power Supply (C3KX-PWR-350WAC/2), but the default included primary power supply is the Catalyst 3K-X 715W AC Power Supply (C3KX-PWR-715WAC). My questions are the following:
1. Will this combination of power supply work?
2. Will the C3KX-PWR-350WAC/2 be able to power up the switch if the primary power supply of 715W fails?
3. Will the PoE will be lost if the primary power supply fails and only the secondary power supply of 350W keeps working?
4. If this secondary power supply of 350W is not suitable for PoE, why it is available as a secondary power supply option in the Dynamic Configurator Tool for a PoE switch?
View 4 Replies
View Related
Mar 6, 2013
I understand that 8700W enhanced AC power supply is Compatible with 6-, 9-, and 13- slot chassis
Based on 8700W Enhanced PS datasheet, it can be installed into existing Cisco Catalyst 6500 Series Switch chassis: both E- and non-E series Cisco Catalyst 6500 Series Switch chassis.
Can we use 8700W enhanced AC power supply with 6513 externally / internally (within one of the chassis slots like 6513-E ?
View 1 Replies
View Related
Feb 13, 2012
I have a 2960S connected to an RSP 2300. The 2960S is currently running off of the RPS, and I would like to switch it back to the internal power supply. Can I just run "power supply 1 on"? Will this cause the switch to reboot? Also I am concerned because when I do a show env power it shows: [code]
Is it normal for the internal power supply to show Unavail when running off RPS?
View 1 Replies
View Related
Feb 25, 2013
I had a bad power surge yesterday that took out a 2960g switch and the APC UPS that it was connected too. when plugged in the fan comes on and the syst light stays amber and the rps, stat, duplex. and speed light stay lit and the port lights for ports 21-24 stay lit. plugging it into the console on boot I cant even see rommon, so i dont think its even booting. I would like to find a pinout and voltage guide for the connector comming off the power supply so I can check the voltages coming off the power supply to tell if it is a bad PSU or if it took out the main board.
View 2 Replies
View Related
Jun 9, 2013
I am receiving the following error on 3750 stack switches. have already verified the power status and found ok.
IOS used: Cisco IOS Software, C3750E Software (C3750E-UNIVERSALK9-M), Version 12.2(55)SE3, RELEASE SOFTWARE (fc1)
211540: Jun 10 10:45:17.935 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS: Switch 4's power stack has unbalanced power supplies
211541: Jun 10 10:46:18.045 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS:
[Code]....
View 1 Replies
View Related
Apr 29, 2011
On my D-link routher the power supply broke. I instal another one but it has 2.5A as output instead of 2A as the broken one has. Is it dangerous.
View 2 Replies
View Related
Nov 5, 2012
I am really stuck in enabling ip routing though a simple task. I have configured 10 v LAN's in stacked 3750 switches have ip base image. I want to enable ip routing for inter V LAN communication but it is giving this error:
%COMMON_FIB-4-ISSUENCODEWRONGLEN: Message IPv6 global features, rev B for slots 2 (0x4) is wrong length (10, should be 7).
View 5 Replies
View Related
Oct 31, 2012
I recently bought a bunch of cisco 3750-x switches. I configured them all and started deploying them. A day later, some of the switches started failing on me. When I connect the power cord to the AC main, the power supply module on the back shows "AC OK" LED Green but the "PS OK" LED shows Red. I started referring to the installation guide and it told me that "PS OK" LED turns RED when output has failed. Guessing this I checked with another power supply module that was working, but still I get the same LED indicators.The original power supply module works with other switches.IOS crash...?
View 5 Replies
View Related
Apr 21, 2013
What will be the recommended connectivity of stack power cable in 6 number of 3750x switches ?
Is it similar to the stack cable ?
View 3 Replies
View Related
Feb 12, 2012
Cisco IP phones attached to a Moduke in one of my Cat6500 access Switches suddenly went down. Upon closer inspection of the Switch Sys log, I observed the following Sys log error messages: [Module 9 is experiencing the following error: Inline Power Module - PS Voltage bad. ]A sh Mod output indicates the PoE daughter card and Main Module are "ok" - see attached output. It appears issue is related to the the actual Power Supply module and not the blade module and installed PoE Daughter card. I am inclined to open a TAC case for a PS replacement, but wanted to see if this can be resolved without a hardware replacement. At this time all 48 IP phones attached to this module are out of Service.
View 2 Replies
View Related