Cisco Switching/Routing :: Minimum Power / Voltage Of Switch 3750
May 20, 2013
I want to know how much minimum power required for swicth catalyst 3750.I want to know cause in my building place, the power in unstable so it make my switch corrupt/damage even i add power consistancy....
How much amount power to the ups and ups to switch?
View 5 Replies
ADVERTISEMENT
Feb 25, 2013
I had a bad power surge yesterday that took out a 2960g switch and the APC UPS that it was connected too. when plugged in the fan comes on and the syst light stays amber and the rps, stat, duplex. and speed light stay lit and the port lights for ports 21-24 stay lit. plugging it into the console on boot I cant even see rommon, so i dont think its even booting. I would like to find a pinout and voltage guide for the connector comming off the power supply so I can check the voltages coming off the power supply to tell if it is a bad PSU or if it took out the main board.
View 2 Replies
View Related
Dec 3, 2011
power supply problem...?Switch cisco WS-C3750-24P is showing "Unavail" from sh env all.Switch3750#sh env all FAN is OK,TEMPERATURE is OK,SW PID,Serial# Status Sys Pwr PoE Pwr Watts,Does it means that power supply 1 was removed? failed?,Do you know about another command to see more details?
View 3 Replies
View Related
Jan 16, 2012
I have 4 switches in a 3750-X stack.Here is the output from the stack why are the switches out of order and I'm not able to bring up switch 1 port 1.
switch 4 port 2 shows not connect it is I've checked the cables.
Power stack name: Powerstack-4
Stack mode: Power sharing
Switch 1:
Power budget: 695
Low port priority value: 22
High port priority value: 13
Switch priority value: 4
Port 1 status: Shut
Port 2 status: Connected
Neighbor on port 1: 0000.0000.0000
Neighbor on port 2: c471.fe84.e100
Switch 2:
Power budget: 713
Low port priority value: 21
High port priority value: 12
Switch priority value: 3
Port 1 status: Connected
Port 2 status: Connected
Neighbor on port 1: c471.fe85.3000
Neighbor on port 2: c471.fe80.2800
Switch 4:
Power budget: 697
Low port priority value: 19
High port priority value: 10
Switch priority value: 1
Port 1 status: Connected
Port 2 status: Not connected
Neighbor on port 1: c471.fe80.2800
Neighbor on port 2: 0000.0000.0000
Switch 3:
Power budget: 710
Low port priority value: 20
High port priority value: 11
Switch priority value: 2
Port 1 status: Connected
Port 2 status: Connected
Neighbor on port 1: c471.fe84.e100
Neighbor on port 2: c471.fe7f.eb00s
View 2 Replies
View Related
Jun 9, 2013
I am receiving the following error on 3750 stack switches. have already verified the power status and found ok.
IOS used: Cisco IOS Software, C3750E Software (C3750E-UNIVERSALK9-M), Version 12.2(55)SE3, RELEASE SOFTWARE (fc1)
211540: Jun 10 10:45:17.935 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS: Switch 4's power stack has unbalanced power supplies
211541: Jun 10 10:46:18.045 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS:
[Code]....
View 1 Replies
View Related
Dec 18, 2011
My Dir-615 stopped working some weeks ago and I switched to another router until I had time to look at it. Tonight I checked the ps voltage and it read exactly +5v but just for a test I tried another 5v ps (which tested a little higher) and it worked. The ps that works reads about link +7vdc. Before this the power light came on with the occasional blink but I could't connect.
View 5 Replies
View Related
Oct 31, 2012
I recently bought a bunch of cisco 3750-x switches. I configured them all and started deploying them. A day later, some of the switches started failing on me. When I connect the power cord to the AC main, the power supply module on the back shows "AC OK" LED Green but the "PS OK" LED shows Red. I started referring to the installation guide and it told me that "PS OK" LED turns RED when output has failed. Guessing this I checked with another power supply module that was working, but still I get the same LED indicators.The original power supply module works with other switches.IOS crash...?
View 5 Replies
View Related
Jun 18, 2012
I have the follow error in a SW3750:
%SFF8472-5-THRESHOLD_VIOLATION: Te2/0/1: Voltage low alarm; Operating value: 0.00 V, Threshold value: 3.07 V.
I used the command:
#sho interfaces transceiver
If device is externally calibrated, only calibrated values are printed.
++ : high alarm, + : high warning, - : low warning, -- : low alarm.
NA or N/A: not applicable, Tx: transmit, Rx: receive.
[Code]....
View 1 Replies
View Related
Apr 21, 2013
What will be the recommended connectivity of stack power cable in 6 number of 3750x switches ?
Is it similar to the stack cable ?
View 3 Replies
View Related
Oct 22, 2012
I am connecting power cable (series power cables) on 3750 stacks. i have connected them the same way the stack cables are connected i.e. fo rexample on a stack with 3 3750s:
1- fitst slot on fist switch connected the second slot last switch in the stack.
2- second slot/ port on the first switch to the first on second and seoncd on teh second switch to first on the third switch.
this how they are alway been stacked.Now, I need to connect power cables and I have followed the same method for stacks up to 4 switches. it seems that if a stack has more tham 4 switches, then the cabling will be dofferent!?I was wondering what will be on the cabling scheme for stacks more than 4 switches.
View 3 Replies
View Related
May 14, 2012
I am new to this and have ran into some problems. I butilt up my router I was able from the rom> prompt to get my router to boot from SLOT0:xxxxx
Then I did the copy command copy slot0:xxxxxxx bootflash:xxxxxxxMy router starts up fine. I did all my configurations and did my copy run start when I was done. As this is what I do on my 3750s.
My router lost power and rebooted and I lost everything it did not boot up to my last configuration.How do I save my configurations when I am done ? How do I get it to boot from that configuration every time?
View 1 Replies
View Related
Nov 2, 2011
i have an issue to connect a trunk between cisco switch and extreme switch i have many vlans that i want to cross via a link between cisco 3750 switch and a Extreme Alpine 3800 switch
View 12 Replies
View Related
Nov 18, 2012
I have two 3750-X configured to be a stack and I am planning to re-rack these somewhere else. What I would like to know is what are the effects of having the master switch itself lose power? Does it immediately just make the member take over master (there should be no election since there are only 2 switches??) and there would be no loss of connectivity?
View 1 Replies
View Related
Jan 27, 2012
recently a Cisco 3560E switch went down due to a power surge. the switch is getting power but i am only seeing the below message continously. it is keep on rebooting. i try to reset to factory settings/ safe boot nothing worked. is there any way i can bring the switch up or it is hardware failure.Using driver version 1 for media type 2Base ethernet MAC Address: 00:23:33:af:1b:00Xmodem file system is available.The password-recovery mechanism is enabled.Using driver version 1 for media type 2Base ethernet MAC Address: 00:23:33:af:1b:00Xmodem file system is available.The password-recovery mechanism is enabled.
View 5 Replies
View Related
May 31, 2012
we need to relocate our core switch 6500 with sup 720 to another bldg
what is the command to gracefully shut it down I mean power off
I was told one can just switch off the power
View 4 Replies
View Related
Apr 28, 2012
We have Communication Media Module (WS-SVC-CMM) mounted on 6513 switch. It went down twice and we brought it up by applying "power enable module".
View 4 Replies
View Related
Jun 1, 2012
Can a Cisco SG300-10P switch power a Cisco SG200-08 switch over POE? Or an SG200-08P power an SG200-08 via POE? I have an area where I'd like to put a small switch, but would like to avoid having to have electrical power run to it. Or will the SG300 and SG200 POE switches only power endpoint devices such as cameras and IP phones?
View 4 Replies
View Related
May 19, 2012
I have a 6509 that has dual SUP32's.Just want to make sure and give a reason(if there is one). Slot 6 always becomes the active hot on a full reboot. Meaning from no power to the whole switch to powered on. What is the election process for Supervisors?
View 5 Replies
View Related
Sep 26, 2011
I have an issue with a 3560 in my network, after sometimes it fails to give out power to some ip phones,while others are not affected and below is the message i get
"Power given, but Power Controller does not report Power Good"
output of sh power inline and sh env all : everything seems to be ok on the switch
#sh power inline
Available:450.0(w) Used:48.0(w) Remaining:402.0(w)
Interface Admin Oper Power Device Class Max
(Watts)
--------- ------ ---------- ------- ------------------- ----- ----
Gi0/1 auto off 0.0 n/a n/a 15.4
Gi0/2 auto off 0.0 n/a n/a 15.4
Gi0/3 auto off 0.0 n/a n/a 15.4
[code].....
It's solved by a reboot of the switch, i could have suspected a power environnment issue but it's the only equipement disturbing in the network.
View 20 Replies
View Related
Feb 22, 2013
We have configured Cisco 3750X POE series switchs with Stack.WS-C3750X-48P each with Redundant 1100W & 715 W PSU's. They are configured with Stack-Power in Sharing mode and the switches are Smart Stacked as well.IP Phone and Access points are connected its working in last two years,
Now we are facing some issue on Cisco IP Phone and Access point, When i have problem if unplug (disconnect & Reconnect) the IP Phone from Switch port,Power is not comming on switch port.Plug it into another switchport of the same Switch it may not power in any port.I tried shut & no shut and reconfigured on switch port , I have verified multiple switch ports same issue on the switch I have changed cable.
View 2 Replies
View Related
Mar 9, 2012
I have upgraded my C3560-PS-S switch to the latest IOS version 12(2)55-SE4 and it is not providing PoE anymore? It used to work before this upgrade? I searched Cisco bugtrack and there is bug defined for this IOS/Switch.
Switch(config-if)#do show power inline Available:370.0(w) Used:0.0(w) Remaining:370.0(w)
Interface Admin Oper Power Device Class Max
(Watts)
--------- ------ ---------- ------- ------------------- ----- ----
Fa0/1 auto off 0.0 n/a n/a 15.4
Fa0/2 auto off 0.0 n/a n/a 15.4
Fa0/3 auto off 0.0 n/a n/a 15.4
Fa0/4 auto off 0.0 n/a n/a 15.4
Fa0/5 auto off 0.0 n/a n/a 15.4
Fa0/6 auto off 0.0 n/a n/a 15.4
Fa0/7 auto off 0.0 n/a n/a 15.4
Fa0/8 auto off 0.0 n/a n/a 15.4
Fa0/9 auto off 0.0 n/a n/a 15.4
Fa0/10 auto off 0.0 n/a n/a 15.4
Fa0/11 auto off 0.0 n/a n/a 15.4
Fa0/12 auto off 0.0 n/a n/a 15.4
Fa0/13 auto off 0.0 n/a n/a 15.4
Fa0/14 auto off 0.0 n/a n/a 15.4
Fa0/15 auto off 0.0 n/a n/a 15.4
Fa0/16 auto off 0.0 n/a n/a 15.4
Fa0/17 auto off 0.0 n/a n/a 15.4
Fa0/18 auto off 0.0 n/a n/a 15.4
Fa0/19 auto off 0.0 n/a n/a 15.4
Fa0/20 auto off 0.0 n/a n/a 15.4
Fa0/21 auto off 0.0 n/a n/a 15.4
Fa0/22 auto off 0.0 n/a n/a 15.4
Fa0/23 auto off 0.0 n/a n/a 15.4
Fa0/24 auto off 0.0 n/a n/a 15.4
View 3 Replies
View Related
Nov 13, 2011
We have one switch 4510R which could have total 300 cisco GE color phone connected. That means 300x15.4=4620W. Considering the 89% effiency for the PoE line cards, that means each line card needs 5191W input power from chasis power supply. Based on the 6000W power supply specs, only up to 4800W is allocated for PoE purpose. But we need 5191W from power supply which redundant mode can't offer. We don't want to go with combined mode. So should we add external power shelf to add more power?Another question will be how much power we need from utility or UPS. For example, the efficency of cisco power supply is 75% and we use two 6000W power supplies in redudant mode. Then we need 8000W. The voltage is 220V. Then the AMP we need is 36.4A from UPS or utility power.
View 2 Replies
View Related
Apr 16, 2012
i have one of my switch modules that shows PwrDown when i issue the command show mod.
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
1 9 Supervisor Engine 32 8GE (Active) WS-SUP32-GE-3B SAD09120263
2 48 48 port 10/100/1000mb EtherModule WS-X6148-GE-TX SAL1029VWZ5
[Code]....
i tried disabling the diagnostic monitor for the module, did a power enable module command and then reset it but it still fails. this is the third blade that i am replacing in a few weeks and i still get the same error. i am persuded that it is not a hardware since it is the third blade in a matter of weeks. after the module reset, i receive this error % module 3 is operationally off (FRU-power failed)
could an ios upgrade solve this issue? are there any ios related bugs?
View 10 Replies
View Related
Oct 28, 2012
We have 9 x 3750x switches with 5-nonPOE and 5-POE. There is a limitation with 4 POE per stack with Stack Power.
Can we combine all 9 to one stack since there are only 4 POE?
Or, is the 4-switch limitation applied regardless if they are mixed with POE and non-POE?
View 7 Replies
View Related
Dec 8, 2012
I would like to check if it may be possible to hot-upgrade/swap the 4506E power supplies? Based on the configuration guide; I have summarized the steps as follows:
1. Switch has 2 existing power supplies to be upgraded
2. Remove right side/bay 2 power supply and install new power supply
3. At this point; the new power supply will be in err-disabled due to different power supplies on the switch
4. Remove the left side power supply and install new power supply
For item 4; during the removal of the old power supply in bay 1/left side and installation of the new power supply; I am wondering if the switch would lose power even though the new power supply is installed in bay 2?
View 1 Replies
View Related
May 18, 2012
The following discussion is based on cisco cat 6500 switches with two power supplies: p1 and p2. . Both power supplies are running in combined mode .Each power supplies is rated with 500 watts max( I just picked 500 watts for simplicity)Combined mode In combined mode, each power supply provides approximately 83% of its capacity to the chassis. This allows for greater utilization of the power supplies and potentially increased PoE densities
1) Let say our specific 6500 switch's configuration requires 1000 watts. We have two power supplies p1 and p2 ,each with rated power of 500 watts. Both power supplies must operate in combined mode. Will power supplies be able to meet the total load power requirement of 1000 watts?
Here is my understanding :The maximum power delivered by each power supplies is 83 percent of its rated power, assuming power supplies are running in combined mode.
So Maximum power delivered by power supplies
= 83% of p1+ 83% of p2
= 83% of 500 + 83% of 500
= 415 +415
=830 watts
Thus the required load of 1000 watts can not be met by our power supplies in combined mode.
2 )Suppose our switch's switch configuration needs 500 watts. Again our power supplies each rated with 500 watts, are configured for combined mode. How much power is being delivered by each power supply? Is it 83 percent of the total load i.e 500 watts?
View 4 Replies
View Related
May 10, 2012
My cisco 3550 EMI switch is not responding to power connection. I have checked and changed power cable. its still not working.fan is not running and no lights on front panel
View 3 Replies
View Related
Nov 6, 2012
I have a 3750x 48port POE switch that I installed a second power supply in. But it doesnt power on. Am I supposed to enable it in the switch somewhere? I've plugged it into a couple different outlets so I know that's not the problem.
View 4 Replies
View Related
Oct 1, 2012
What is the minimum distance to be maintained while laying Power cable ( light and fan power points) and Data cable?
View 1 Replies
View Related
Apr 7, 2012
After a power problem at our data centre we find Module 11 of our Cisco 6513 Core Switch in PWR Down state.Show Module 11 returns: Status: PWRDownShow Power Status Module 11 returns: OperStatus Off (Module Reset due to an exception or user request).The command:
Power enable Module 11 was issued and returned the following: %PM_SCP-SP-1-LCP_FW_ERR: System resetting module 11 to recover from error: Linecard received system exception. Errcode = 2509000001.%OIR-SP-3-PWRCYCLE: Card in module 11 is being powercycled Öff (Module reset due to exception or user request%C6KPWR-SP-4-DISABLED: Power to module in slot 11 set off (Module Reset due to exception or user request),We have restarted the switch twice. The module is currently not passing traffic causing downtime to services.
View 6 Replies
View Related
Dec 7, 2011
I am facing switch reboot issue when power of switch restore from RPS to AC.
View 1 Replies
View Related
Dec 11, 2011
i recently deployed cat4507e switch along with 3 nos of WS-X4748-RJ45V+E - 48 port gigabit PoE modules. I am using polycom IP560 phones.
I am facing issue of some switch ports (randomly) stops supplying power to phone at random time. So far there are about 4 incident and i have been plugging those connection to different - usused ports. I am planning to RESET the switch module during weekend and i think it might fix issues with those ports.
But what would be quick and easy way to fix this issue when the issue is faced? How/what to check on switch port interface wrt to power? If switch module is falling short of overall power requirement, is there a way to boost the power?
View 17 Replies
View Related
Nov 28, 2012
We have a cisco catalyst 6509 with Supervisor Engine . After power outage, the switch always start in Rommon mode. Configuration register is 0X2102, we want to it always start in normal mode. What should i do?
View 3 Replies