Cisco Switching/Routing :: Switch 6509 In ROMmon Mode After Power Outage?
Nov 28, 2012
We have a cisco catalyst 6509 with Supervisor Engine . After power outage, the switch always start in Rommon mode. Configuration register is 0X2102, we want to it always start in normal mode. What should i do?
View 3 Replies
ADVERTISEMENT
Dec 16, 2012
I have 6509 E. Actually what happen it last 3-4 times it reload its self and got stuck in rommon mode, i tried to boot it with boot by connecting a console cable on supervisor 720 2b. What and where is problem and why is stuck in rommon after reload.
View 11 Replies
View Related
Jan 24, 2012
I have a 3550 switch that was replaced at a remote site with no IOS. This is a switch not a router so tftpdnld does not work.
[Code]...
The problem is the switches interface never comes up so try to connect to the tftp server. I read on google it can't be done on a switch to copy from tftp to flash in rommon mode on a switch and to use XMODEM. My problem is I do not have access to it, I ssh into a 3640 which is an access server for all devices and that is how I have console to it, how to use XMODEM over ssh.
But I'm fairly certain that there has to be a way to just copy it from tftp? I have a 3550 local and when I put it in rommon mode it stops the port check at port, port 1 goes from green when you plug it in to off then port 2 changes to amber and the rest green. So just by the look of this I would believe tftp would work; you just need to use port 1.
View 1 Replies
View Related
Oct 21, 2012
I have one cisco 4507R+E.My question is if the IOS of the acive SUP crushed and the switch is running through it's second SUP then how to restore the IOS of the first SUP.Also how to access the ROMON mode of the crushed SUP when switch is running through second SUP.
View 1 Replies
View Related
May 19, 2012
I have a 6509 that has dual SUP32's.Just want to make sure and give a reason(if there is one). Slot 6 always becomes the active hot on a full reboot. Meaning from no power to the whole switch to powered on. What is the election process for Supervisors?
View 5 Replies
View Related
Apr 16, 2012
i have one of my switch modules that shows PwrDown when i issue the command show mod.
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
1 9 Supervisor Engine 32 8GE (Active) WS-SUP32-GE-3B SAD09120263
2 48 48 port 10/100/1000mb EtherModule WS-X6148-GE-TX SAL1029VWZ5
[Code]....
i tried disabling the diagnostic monitor for the module, did a power enable module command and then reset it but it still fails. this is the third blade that i am replacing in a few weeks and i still get the same error. i am persuded that it is not a hardware since it is the third blade in a matter of weeks. after the module reset, i receive this error % module 3 is operationally off (FRU-power failed)
could an ios upgrade solve this issue? are there any ios related bugs?
View 10 Replies
View Related
May 18, 2012
The following discussion is based on cisco cat 6500 switches with two power supplies: p1 and p2. . Both power supplies are running in combined mode .Each power supplies is rated with 500 watts max( I just picked 500 watts for simplicity)Combined mode In combined mode, each power supply provides approximately 83% of its capacity to the chassis. This allows for greater utilization of the power supplies and potentially increased PoE densities
1) Let say our specific 6500 switch's configuration requires 1000 watts. We have two power supplies p1 and p2 ,each with rated power of 500 watts. Both power supplies must operate in combined mode. Will power supplies be able to meet the total load power requirement of 1000 watts?
Here is my understanding :The maximum power delivered by each power supplies is 83 percent of its rated power, assuming power supplies are running in combined mode.
So Maximum power delivered by power supplies
= 83% of p1+ 83% of p2
= 83% of 500 + 83% of 500
= 415 +415
=830 watts
Thus the required load of 1000 watts can not be met by our power supplies in combined mode.
2 )Suppose our switch's switch configuration needs 500 watts. Again our power supplies each rated with 500 watts, are configured for combined mode. How much power is being delivered by each power supply? Is it 83 percent of the total load i.e 500 watts?
View 4 Replies
View Related
Jan 2, 2012
All of our VoIP phones bounced (re-registered) in the middle of the work day and we do not know why. There is no maintenance going on at this time. The phones came back up right away. Upon further investigation, I only found one error message on our core switch (WS-6509 running IOS ver. 12.2(18)SXF13) and I'm wondering if that was the cause:
Jan 3 13:51:04.030: %SIBYTE-SP-5-SB_OUT_OF_RX_DSCR_CH1: Out of RX descriptors on mac 0 - channel 1 (count: 299)
I cannot find any other instances of this error message from the internet.
View 1 Replies
View Related
Oct 27, 2011
We had some problems with 3560G-48PS-S switches and PoE for our phones. IOS is 12.2(50)SE3. There were some problems after power outage. The switches didn't reboot because we have two eletric circuits. But after the problems we had no PoE on all ports.
The switches logged to following syslog message:
%ILPOWER-3-CONTROLLER_PORT_ERR: Controller port error, Interface Gi0/17: Power Controller reports power supply VDD under voltage
I can't find any informations in the error message decoder for that. But there was another thread here with quiet the same message, but another problem regarding RPS2300.
After reloading the device all works fine again. The workaround with the commands "power inline never" and "power inline auto" I didn't know till today.
Some information about that syslog message?
My guess is that there was a voltage swing and the switch powered down its supply? Is that possible?
View 5 Replies
View Related
Apr 22, 2013
I recently copied a configuration from a router 2800 to a 2900. After a power outage no one can connect outside of the network through the new router. Before the outage all was fine. I put back the old router and all is fine which eliminates any cable or switch error. I have the router totally disconnect. I notice the configuration is in place. My question is there any diagnostics that I can run to see if there is any hardware failure. It seems to boot up fine.
View 1 Replies
View Related
Oct 23, 2011
What is PIM? give me an example when I will use and not use the PIM command.
View 4 Replies
View Related
Jul 24, 2011
I am facing a problem with a cisco 6509 that goes into rommon every time i restart. If i give the command
rommon 1> boot
it will pick up the IOS on the sup-bootdisk: or bootdisk: and boots up but i dont understand why on reboot it wont pick up this IOS and boot itself and why do i have to write boot command everytime on rommon.
I have also explicitly given the command "boot system bootdisk:IOSNAME.bin" in the startup config file but still no luck.
View 36 Replies
View Related
Dec 12, 2012
I have ROM MON version 12.2(17r)S2 and I am trying to determine if I need to chnage this to 12.2(17r)SX7. It does not appear I need to with the upgrade to 12.2(33)SXI10. Is this correct?
View 1 Replies
View Related
Dec 27, 2012
Got a long lingering, year long issue that has spanned about 8 supervisor cards and a complete chassis swap. The 6509 acts as a ITN in our facility. The active sup card at random points of pipe usage boots into rommon mode, seriously inhibiting our company. I'm able to swap the 2 fiber pairs that we had going into the active supervisor card into the secondary and usually this works for another random amount of time, however, today it occured within minutes of hooking up the fiber links. Sitting there for about 5 minutes it booted into ROMMON. When this happens, I'm able to boot the sup card back to good status. Previous remedial actions, other than replacing sup cards/chassis, was checking the config register and making sure it was x2102. Previously, it was not, and we corrected and reloaded and it took, we thought this would fix the problem, until today.
[code]....
View 5 Replies
View Related
Dec 10, 2011
I'm currently pursuing to take my CCNA and am currently studying for it, but have recently encountered a problem with one of my 1760 routers that I can not solve.Yesterday I went to boot up my router like normal, however when I went into hyperterminal I noticed the router was in Rommon mode. Thinking I could change the configuration registry, I tried to bypass the NVRAM by using confreg 0x2142. However this still causes the router to go into Rommon mode. I am getting an error that states that there is insufficient memory to load the IOS image. [code]
I have used the dir flash: command and can see the IOS image, and try to boot from it (boot flash:iosimagename) but it will still go back into rommon mode. I also just swapped the RAM from my other 1760 into this 1760 and it booted up and went into normal configuraiton mode without any issues. However, the other router now will not load it's IOS image and I get the exact same error.I'm at a loss here, and have searched to figure out where or how I can just wipe the router clean to try and start fresh, but cannot get out or Rommon mode. The only thing I can think of is that the RAM went bad since it wont boot up either machine.
View 1 Replies
View Related
Oct 24, 2012
I'm fairly new to networking and need to migrate an old core to a new core. I have a 6509-e Switch that I had an RMA on one of my 720 sup cards. After receiving the sup card I swapped my slave out with the new one, expecting it to boot into ios. It booted into Roman. I tried to boot the image manually and it did the same thing. I also tried to boot from my flash and, again, booted into ROMmon.
Question: If i configure and change the boot to boot from image it tells me i need to reset or power cycle first. Will this reset the entire switch? As this is production I'd rather not.
I am at home now, but I can supply any logs/hardware model/configs tomorrow. I thought I would see if this is an easy fix.
View 23 Replies
View Related
Oct 5, 2008
I am trying normal password recovery for (cisco routers) for IAD 2400 but iam unable to get in rommon mode ?
View 3 Replies
View Related
Feb 28, 2011
I have a 6500 chassis with 2 power supplies. At the moment I am using the default configuration:
power-redudancy mode redundant
The problem is that an inserted module is in "power deny" state due too insufficient power.
I know, that It's not a good idea to change into combined mode (loss of redundancy), but my customers requested this anyway.
So I will change to combined mode. So here's the 1 million dollar question: "Which modules will go into power deny, if one of my power supplies fails?"
The 6500 config guide states:
"Power supply is removed withredundancy disabled
• System log and syslog messages are generated.
• System power is decreased to the power capability of one supply.
• If there is not enough power for all previously powered-up modules, some modulesare powered down and marked as power-deny in the show power oper state field."
Well, do you know if there's any way to configure some kind of priority? E.g. I definetly don't want by 10Gig Module or WiSM module to be in power deny. Can i statically make sure, those module will be powered on for sure? Like: "power enable module slot_number" How is this calculated? Or is random?
View 3 Replies
View Related
Dec 12, 2012
I have a Catalyst 4506e that works fine but if reload, it boots in rommon mode. I can start it with a boot command, but by default, i must type a command. My config-register is 0x2102.
View 5 Replies
View Related
Aug 7, 2012
I have a 512MB USB Flash device and was able to boot the IOS on the C2960 from it.After that i tried to Copy the IOS file from the USB to the system flash, but it could not find the USB Device.At plugging in the device the systems tells me: "Transfer type 2 not supported" I configured the USB device in NTFS and FAT both are able to boot with the ROMMON, but the normal system does not accept them and i know i can do the copy over a TFTP from my laptop, but it is strange that rommon accepts the usb device and the system does not?
View 1 Replies
View Related
Nov 22, 2011
I attempted to enable jumbo frames on a Nexus 5010 (NX-OS version 4.2(1)N1(1)). I created the policy map below and lost access to the switch.
policy-map type network-qos jumbo
class type network-qos class-default
mtu 9216
After recovery I see from the logs that all vlans and interface were suspended. I've attempted to look for reasons for a compatibility issue but I am unable to find what is checked and what could have been incompatible. The other troubling thing is the adjacent switch suspended its interfaces too but no change was done there. What I need to look out for so that this does not happen again?
2011 Nov 22 23:43:09 phx-ipcg1dwfcma %ETHPORT-3-IF_ERROR_VLANS_SUSPENDED: VLANs 1,10,601 on Interface port-channel1 are being suspen
ded. (Reason: QoSMgr Network QoS configuration incompatible)
2011 Nov 22 23:43:09 phx-ipcg1dwfcma %ETHPORT-5-IF_TRUNK_DOWN: Interface port-channel1, vlan 1,10,601 down
2011 Nov 22 23:43:09 phx-ipcg1dwfcma %ETHPORT-3-IF_ERROR_VLANS_SUSPENDED: VLANs 10 on Interface port-channel508 are being suspended.
[code]....
View 9 Replies
View Related
May 9, 2012
i have a Cisco 6513 it is used one, i have tryed to boot it but it did not work, it alwayes go to rommon mode and i am not able to know what is the issue,
when it boot i get the below outpot from the switch.
System Bootstrap, Version 8.1(3)
Copyright (c) 1994-2004 by cisco Systems, Inc.
Testing lower main memory - data equals address
[Code].....
View 3 Replies
View Related
Jan 28, 2011
How can i Upgrade Catalyst 2960 switch software in Rommon mode (switch:)
Right now flash is empty.
View 7 Replies
View Related
Nov 20, 2011
The power supply on 6509 NEB A is not working with me . I have installed only one power supply on the box WS-CAC-3000W
It is showing me that "Input OK , Output fail " from the LCD
I tried with another WS-CAC-3000W , another power source but still same problem .
View 2 Replies
View Related
Feb 19, 2012
I am trying to find a way using CLI that I can identify the amperage being used by a 6509 chassis. I have looked through all of the sh power and sh env commands and seem to only find the power being used on the DC side (since the output referemces 42V). Ddint know if there was something I was overlooking. To each things from the AC side will take getting an electrician in which is what I was hoping not to have to do.
View 4 Replies
View Related
Nov 21, 2011
I have a 6509 box with the following modules:
View 4 Replies
View Related
Nov 28, 2012
We had power failure catalyst 6509 and after the device boot up ssh does not work any more below is error messages
line con 0
access-class 90 out
logging synchronous
[Code]....
View 3 Replies
View Related
Oct 2, 2012
We have two 6500s. One is running in power redundant mode and the other is running in combined mode.We need to change the one running in combined mode to redundant mode to ensure it can run ok on one supply if needed but I have a couple of questions.
1. Assuming that we are not oversubscribed on the power allocated, does changing the mode cause any disruption?
2. The switch running in combined mode seems to have allocated some power for an "Inline Local-Pwr-Pool" which is not allocated on the switch running in redundant mode (see attached). Does this allocation will be needed if we change the power mode?
View 1 Replies
View Related
Mar 25, 2012
My current production network is setup using VTP in Client mode, and I am looking to enable VTP Transparent so I can enable the extended VLANs. My main question would be, would enabling VTP Transparent on my 6509 affect all of the access switches it is connected to? And if so, would changing all of the access switches to VTP Transparent allow them to regain connectivity quickly with little downtime? Or is there another way that I should be handling this situation to enable the extended VLANs?
View 2 Replies
View Related
Jan 14, 2013
I'm working at a company that has several 6509 switches running CatOS. They have two of the 6509's running in vtp server mode and the rest as clients. I set up a new vlan from one of the vtp servers and it propagated out. The problem comes when I try to assign a port on one of the vtp clients to this new vlan. It gives me an error that the switch must be in vtp server mode to add/delete vlans. I'm not trying to add/or delete a vlan just trying to add a port into an existing vlan. I'm hesitant to put the switch in vtp server mode. Is this a CatOS thing or is there a specific command to accomplish this?
View 5 Replies
View Related
Jun 11, 2012
We are facing to an annoying issue. We have a 6509 running in Catos 8.3(4) with WS-X6548-GE-TX, WS-X6348-RJ-45 and WS-X6148-RJ-45. When we configure the mode in auto negotiation, it comes up in half duplex. We need to configure the speed mode at 100Mbit/Full to make it work. But if the chassis or port restarts (not the server), the link becomes half duplex. This happens only on module in Gigabyte like WS-X6548-GE-TX.
Cable have been replaced but does not work. It is not happened on another chassis running on IOS 12.2(18)SXF17b with WS-X6548-GE-TX.
View 4 Replies
View Related
Oct 26, 2011
I'm having a problem with some new gear and can't seem to figure it out. I have a 3750X-48P-S with a C3KX-10G-NM using SFP-10G-LR transceivers and I'm trying to trunk that with a 6509 that has a X2-10G-LR transceiver over single mode fiber. This is not working. Cisco TAC says the SFP+'s that we just got brand new are both bad and we need to order new ones. I find that hard to believe but who knows.
The switch recognized the module and I tested all 4 ports in gigabit mode using GLC-SX-MM transceivers, all worked great. I have the SFP+'s in tengig1/1/1 and 1/1/2 as they should be. There are no other SFP's in the module either.
When I do a sho int tengig1/1/1 and 1/1/2 the media type doesn't show the transceiver that is installed like it does for the GLC-SX-MM ones. Maybe it's not supposed to or maybe it just doesn't recognize them and it's a hardware issue.
View 5 Replies
View Related
Apr 1, 2013
I am trying to use a Tekradius Windows2008 server to aaa authenticate switch admin logins. The Radius server and 6509 loop0 are in a management VRF "netman". I can happily ping to and from the Server and loopback0 interface without issue. I have also tested the radius server account using RadiusNT on a workstation. I get an accept reply with the following variables..
shell:priv-lvl=15
NAS-Prompt
Here are the relevant parts of my config as far as I can see..
aaa new-model
aaa group server radius SRADIUS
server-private 192.168.1.101 auth-port 1812 acct-port 1813 key cisco
ip vrf forwarding netman
ip radius source-interface Loopback0
!
aaa authentication login default group SRADIUS local
[code]...
View 1 Replies
View Related