Cisco Switching/Routing :: 6509 - After Power Failure SSH Does Not Work?
Nov 28, 2012
We had power failure catalyst 6509 and after the device boot up ssh does not work any more below is error messages
line con 0
access-class 90 out
logging synchronous
[Code]....
View 3 Replies
ADVERTISEMENT
Jan 31, 2012
I have a WS-C6509-E (R7000) and am trying to implement some proactive monitoring for environmental alerts. What is the output from a Power Supply failure for the following “sh log” “sh environment alarm”.
View 1 Replies
View Related
Jul 22, 2012
I have a switch 3560v2 with an IOS 12.2(50) SE1.All the lights ON and console error message below:POST: inline power post failed for port 0 up to port 15.Then, the system hanged and all lights (indicator) ON.
View 5 Replies
View Related
May 15, 2013
setting up VRF-lite on redundant 6509-E chassis to account for chassis failure? Let's say I have 2x 6509-Es configured with HSRP for 2 vlans, ServerA and ServerB. So
6509-A#
!
interface Vlan10
description ServerA VLAN
ip address 10.10.10.2 255.255.255.0
ip flow ingress
standby 1 ip 10.10.10.1
standby 1 priority 105
[code].....
I now need to create an environment where the Server VLANs can be provided for two customers and they need to be wholly separate. On 6509-A, I make VRF CustomerA and VRF CustomerB and I assign Vlan10 to VRF CustomerA and Vlan20 to CustomerB. Do I create the SAME VRFs on 6509-B with the same logic?
View 1 Replies
View Related
Nov 20, 2011
The power supply on 6509 NEB A is not working with me . I have installed only one power supply on the box WS-CAC-3000W
It is showing me that "Input OK , Output fail " from the LCD
I tried with another WS-CAC-3000W , another power source but still same problem .
View 2 Replies
View Related
Feb 19, 2012
I am trying to find a way using CLI that I can identify the amperage being used by a 6509 chassis. I have looked through all of the sh power and sh env commands and seem to only find the power being used on the DC side (since the output referemces 42V). Ddint know if there was something I was overlooking. To each things from the AC side will take getting an electrician in which is what I was hoping not to have to do.
View 4 Replies
View Related
Nov 21, 2011
I have a 6509 box with the following modules:
View 4 Replies
View Related
May 19, 2012
I have a 6509 that has dual SUP32's.Just want to make sure and give a reason(if there is one). Slot 6 always becomes the active hot on a full reboot. Meaning from no power to the whole switch to powered on. What is the election process for Supervisors?
View 5 Replies
View Related
Apr 16, 2012
i have one of my switch modules that shows PwrDown when i issue the command show mod.
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
1 9 Supervisor Engine 32 8GE (Active) WS-SUP32-GE-3B SAD09120263
2 48 48 port 10/100/1000mb EtherModule WS-X6148-GE-TX SAL1029VWZ5
[Code]....
i tried disabling the diagnostic monitor for the module, did a power enable module command and then reset it but it still fails. this is the third blade that i am replacing in a few weeks and i still get the same error. i am persuded that it is not a hardware since it is the third blade in a matter of weeks. after the module reset, i receive this error % module 3 is operationally off (FRU-power failed)
could an ios upgrade solve this issue? are there any ios related bugs?
View 10 Replies
View Related
Nov 28, 2012
We have a cisco catalyst 6509 with Supervisor Engine . After power outage, the switch always start in Rommon mode. Configuration register is 0X2102, we want to it always start in normal mode. What should i do?
View 3 Replies
View Related
Dec 5, 2012
how can I enable an automatic power-on after a power failure on an ASA 5512-X?
View 5 Replies
View Related
Mar 3, 2013
how can I enable an automatic power-on after a power failure on an ASA 5512-X?
View 12 Replies
View Related
Jun 9, 2013
I am receiving the following error on 3750 stack switches. have already verified the power status and found ok.
IOS used: Cisco IOS Software, C3750E Software (C3750E-UNIVERSALK9-M), Version 12.2(55)SE3, RELEASE SOFTWARE (fc1)
211540: Jun 10 10:45:17.935 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS: Switch 4's power stack has unbalanced power supplies
211541: Jun 10 10:46:18.045 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS:
[Code]....
View 1 Replies
View Related
Sep 4, 2012
After stacking two 3750X switches, with four equal power-supply's, with StackWise and PowerStack , still got the next message every few hours %PLATFORM_ENV-1-FRU_PS_ACCESS: FRU Power Supply is not responding (gn4m-rt1p08-04-2)( note that the message revers to the second switch in the stack ) although the stackwise and powerstack on the switches is oke and are working correctly. !
Config : Stack-power in power-sharing mode/strict With CLI on the switch : All the power supply's and stack-power details, prio look OK.
Only: LMS prime /inventory/cisco-view/configure/power supply status result : some power supply's are marked as disabled.with the command > power supply 2 slot a off/on I manage to get the status back to "normal", but after a few hours some power supply's are again marked as "disabled".
Looks like SNMP en IOS difference from opinion.
Hardware
WS-C3750X-24S-S
C3KX-PWR-350WAC
Software
15.0(2)SE
C3750E-UNIVERSALK9-M
View 5 Replies
View Related
Apr 14, 2013
We have two switches of the same model (WS-C3560-48PS-S) that are not providing PoE. I'm trying to remotely determine what the cause of the issue is.
Here is some output.
Hostname#show power inlineAvailable:0.0(w) Used:0.0(w) Remaining:0.0(w)
Interface Admin Oper Power Device Class Max (Watts)--------- ------ ---------- ------- ------------------- ----- ----Fa0/1 auto off 0.0 n/a n/a 15.4Fa0/2 auto off 0.0 n/a n/a 15.4Fa0/3 auto off 0.0 n/a n/a 15.4Fa0/4 auto off 0.0 n/a n/a 15.4Fa0/5 auto off 0.0 n/a n/a 15.4Fa0/6 auto off 0.0 n/a n/a 15.4Fa0/7 auto off 0.0 n/a n/a 15.4Fa0/8 auto off 0.0 n/a n/a 15.4Fa0/9 auto off 0.0 n/a n/a 15.4Fa0/10 auto off 0.0 n/a n/a 15.4(code)
View 1 Replies
View Related
Feb 28, 2011
I have a 6500 chassis with 2 power supplies. At the moment I am using the default configuration:
power-redudancy mode redundant
The problem is that an inserted module is in "power deny" state due too insufficient power.
I know, that It's not a good idea to change into combined mode (loss of redundancy), but my customers requested this anyway.
So I will change to combined mode. So here's the 1 million dollar question: "Which modules will go into power deny, if one of my power supplies fails?"
The 6500 config guide states:
"Power supply is removed withredundancy disabled
• System log and syslog messages are generated.
• System power is decreased to the power capability of one supply.
• If there is not enough power for all previously powered-up modules, some modulesare powered down and marked as power-deny in the show power oper state field."
Well, do you know if there's any way to configure some kind of priority? E.g. I definetly don't want by 10Gig Module or WiSM module to be in power deny. Can i statically make sure, those module will be powered on for sure? Like: "power enable module slot_number" How is this calculated? Or is random?
View 3 Replies
View Related
Apr 4, 2012
In a stand alone 3750x switch configuration, can the secondary power supply only act as a redundant power supply (active/standby), or can it become a "pool" of power similar to power sharing mode for StackPower (somewhat active/active)? I understand there is no stack involved here but I'm curious if this functionality is possible.
View 1 Replies
View Related
Nov 21, 2011
I currently have a couple of 6509 chassis (router/switches) with the following hardware blades:
x3 48 ports
x1 NAM
x2 Sup720
Running 12.2(18)SXF3
I am keeping the four Sup720 modules and have purchased new versions of the others blades including two new 6509-E chassis?Can I take my stand-by Sup720 out of the production machine and insert it into the new chassis?
View 2 Replies
View Related
Nov 21, 2011
I currently have a couple of 6509 chassis (router/switches) with the following hardware blades:
x3 48 ports
x1 NAM
x2 Sup720
Running 12.2(18)SXF3.I am keeping the four Sup720 modules and have purchased new versions of the others blades including two new 6509-E chassis. Can I take my stand-by Sup720 out of the production machine and insert it into the new chassis?
View 2 Replies
View Related
Apr 4, 2013
We have several SF-300-48P switches, eveytime there is a power failure the switches need to reboot 2 or 3 times before they are able to route packets again.
View 1 Replies
View Related
Apr 18, 2012
I've got the power cut while PC was running (w7). After rebooting I'm not able to connect to the internet anymore.
In Device Manager, under Network Adapters there is a "Realtek PCIe GBE..." device properly installed. But under Other Devices there are now more entries with exclamation mark:
- Network controller
- Multimedia controller
- PCI Communication controller
etc
I tried updating the drivers, then deleting and reinstalling but no success so far. Still can't connect to the internet. The browser can see the router, at 192.168.1.1 I don't know where the problem is.
View 4 Replies
View Related
Jan 13, 2013
We have cisco wlc 2125 with 13 AP 1131g. All works good. But after power failure one AP can not join to controller, only reset work to recover connection AP to WLC. Additionally, we don't have access to rs-232 port on AP. In this moment on WLC we can see DISCOVERY request from AP and response from WLC to AP, but AP don't send JOIN to controller.
View 2 Replies
View Related
Mar 18, 2013
I bougth a used ASA 5505 on ebay which is experiencing this problem [url]... LEVELS or at least the described problem, if i touch the appliance while it is running it will somtimes go to this non working state as well
View 11 Replies
View Related
Mar 25, 2012
I'm having the following issue with a couple of 1231's.
Some overall config info first:
This is a small office with 2x Catalyst 2950 (24-port, no PoE) switches and 4 AP1231G (autonomous). The APs get PoE from a PWRINJ3 each. The injectors are powered by the AP power supplies. Injectors and power supplies are mounted in the patch closet.
The 2 switches are connected together over 4 ports (20-23 on each switch), these ports are set to 1Q Trunk mode.
The APs are connected to the switches, 2 to each switch, on port 1-2. These ports again are configured as 1Q Trunk.
APs are connected to the switch as follows:
[switch] <- patch cable-> [injector] <- patch cable -> [patch panel] <- static cabling -> [outlet] <- patch cable -> [AP]
All this has been working without problems for a number of years.
A few weeks back, AP2 did not restart after a power cut (everything else did). All LEDs are off, port on switch has no LEDs lit. I did not get around to investigating this furtehr until last week. I unmounted (failed) AP2, took it to the spot where (working) AP3 hangs, and plugged it to the cable of AP3. AP2 came to life immediately. I unplugged it and plugged AP3 back in, which restarted immediately.
So I suspect a power supply issue on AP2. I took the injector and power supply that fed AP2 out of the patch closet. When connecting AP2 directly to the power supply, it came to life immediately. So I figure the injector is defective.
On the same day, I notice AP4 is also dead (again all LEDs off, no idea how long, could have been that day or could have been a few days - it has definitely been working after the power cut that appeared to have killed AP2).
So I order 2 new PWRINJ3s and for good measure 2 new power supplies. Later that day, I took the injector and power supply that fed AP4 out of the patch closet. When I try this combination (AP4, injector4 and P/S4), and connect it to a different wall outlet (and therefore a different port -16 - on the switch) IT WORKS! Should have triggered questions, but did not immediately.
Last Thursday I got the new injectors and power supplies. So I take one of each, hook them upto AP2 at my desk, and AP2 starts up. So I mount new injector2 and new P/S2 in the patch closet, put AP2 back in its place, connect all the cables - NOTHING. AP2 does not start. The "power" LED on the injecvtor lights up green, the "device status" LED remains off. I take AP2, new injector2 and new P/S2 to my desk, hook them upto a wall outlet (connected to switch port 17). AP2 starts immediately.
Meanwhile AP3 has (also) stopped working (no LEDs on at all). As far as I can tell, it stopped working after I briefly disconnected (and reconnected) the patch cable between injector3 and the patch panel in the patch closet. The LEDs on switch port 1 are off.
I have since tried to power cycle both switches (took power off both, waited a while, poewerd both back on). No change.
PS: the APs ran firmware 12.3(8)-JA until recently. AP1, AP3 and AP4 were upgraded to 12.3(8)-JEE after the the power cut that took AP2 out. THis is when I found out AP2 was dead. AP2 was still on 12.3(8)-JA. It was upgraded to 12.3(8)-JEE last week when it was on direct power on my desk.
View 3 Replies
View Related
Dec 15, 2012
Firmware asa805-k8 was installed and saved on an ASA5505. Upon power failure the ASA5505 reverts to an older firmware, asa724-k8. 1) Is it normal for ASA5505's to revert to older version upon power failure. 2) ASDM/web browser doesn't work using IE--username and password brings to empty screen. how to revert back to later image.
"
# sh ver
Cisco Adaptive Security Appliance Software Version 7.2(4)
Device Manager Version 5.2(4)
[Code]......
View 3 Replies
View Related
May 5, 2012
Thinking back, about a month ago I updated the firmware (I can't check version at the moment). The switch has been working fine since then. Today I needed to move some power cables and the switch lost power. Now ALL of the LED lights are flashing green and I can't access the switch. I've tried setting a static IP on my laptop to 192.168.1.20, mask 255.255.255.0, and accessing the switch on 192.168.1.254, but there's no response. I've tried holding in the reset button for at least 30 seconds while the switch is powered on, AND while powering it on. None of that has worked. Also when I first power it on, the system LED flashes orange very quickly for a second or so, then all of the LEDS start flashing green.
View 5 Replies
View Related
Dec 17, 2011
After a recent power outage while my PC was in sleep mode, I don't have wired (Ethernet) connectivity.
I have new Dimension E510XP Media Center Edition, Version 2002, SP3 ver had an issue with wired connectivity on this PC after coming out of sleep mode. Of course, the power failure was unusual.
Observations:
- ipconfig /all shows that I have an IP address
- I can ping the DHCP server listed in ipconfig /all and I also can ping google.com.
- I was going to go a restore point set before the power outage. But, somehow system restore had gotten turned off. Oh, well. I did go ahead and turn system restore back on.
Things I've already tried that did not solve the issue:
- Reboot
- Uninstall/reinstall the network adapter driver. Device Manager says the network adapter card is working properly.
- Looked for an updated network adapter driver on Dell's website. Turns out that I have the latest driver already.
- Followed many of the steps from Microsoft at [URL]
- Checked McAfee Security Center firewall permissions list to see if something got changed. Everything looked okay. Also disabled the firewall just to be sure,
- Disabled SafeEyes internet filter.
- Reset the router. Also swapped router ports with a known good PC. The known good PC still had connectivity, the affected PC (the E510) did not.
View 6 Replies
View Related
Sep 29, 2011
Missing local area connection icon in network connection after power failure?
View 1 Replies
View Related
Nov 20, 2012
1、the router power led's emitting light very weak ,
2、client pc cannot get ip from connected router
these error perhaps happened after a plug power jack action. Dc-dc chip is ME5513,the voltage on its pin4 is about 11.94V,and the voltage on following electrolytic capacitor is 3.3V,its seem normal.
View 1 Replies
View Related
Aug 7, 2011
I have a ~3 month old e1000 v2. In the last 24 hours it appears to have died, all 4 ethernet lights plus the power light and the one to it's left are on continuously. Before I dispose of it, does anyone know if this really is a hardware fail or is there some way to recover it? I've tried a few resets, power cycles and leaving it off for a few hours in the hopes that would bring it back to life but to no avail.
View 5 Replies
View Related
Nov 4, 2011
I am trying to update a switch I bought to the latest IOS using the Cisco Network Assistant but the it is failing becasue it's saying I dont have the space.
In the CLI I get,
Switch#dir all-filesystemsDirectory of flash:/
2 -rwx 109 Mar 01 1993 00:01:47 +00:00 info 3 -rwx 270 Jan 01 1970 00:01:37 +00:00 env_vars 7 -rwx 3081999 Mar 01 1993 00:03:23 +00:00 c2950-
[Code]....
View 5 Replies
View Related
Feb 2, 2012
After trying to downgrade a Nexus 7K from 5.2.1 to 5.1.5 by updating the boot & kickstart boot statements and reloading, I'm now stuck in an endless cycle of reloading. See below:
Is there a break sequence which will allow me to modify the boot statement back to the original via ROMMON or something similar?
[code]....
View 3 Replies
View Related
Mar 11, 2013
I have a cable from an SFP module in a WS-C3750-48P with 12.2(55)SE1 running to a Gigabit port on a Cisco WLC. After the switch recovers from a power failure, the gigabit autonegotiation fails. The cure is a long drive to unplug and reseat the SFP. Note this happens at too many similar sites for this to be a loose connection. Interface shutdown then 'no shutdown' is not sufficient. The state is 'line protocol is down (not connected)'. Interface is configured for switchport mode trunk (auto speed, auto duplex). Command 'switchport nonegotiate' makes no difference. Is there a more powerful command than 'shutdown' which might toggle the interface signals? Is there some way of resetting the SFP? sh int gi 1/0/1 displays 'media type is 10/100/1000BaseTX SFP' and zero packets received.
View 4 Replies
View Related