Cisco Firewall :: ASA 5512-X - Automatic Power-on After Power Failure?
Dec 5, 2012how can I enable an automatic power-on after a power failure on an ASA 5512-X?
View 5 Replieshow can I enable an automatic power-on after a power failure on an ASA 5512-X?
View 5 Replieshow can I enable an automatic power-on after a power failure on an ASA 5512-X?
View 12 Replies View RelatedI bougth a used ASA 5505 on ebay which is experiencing this problem [url]... LEVELS or at least the described problem, if i touch the appliance while it is running it will somtimes go to this non working state as well
View 11 Replies View RelatedFirmware asa805-k8 was installed and saved on an ASA5505. Upon power failure the ASA5505 reverts to an older firmware, asa724-k8. 1) Is it normal for ASA5505's to revert to older version upon power failure. 2) ASDM/web browser doesn't work using IE--username and password brings to empty screen. how to revert back to later image.
"
# sh ver
Cisco Adaptive Security Appliance Software Version 7.2(4)
Device Manager Version 5.2(4)
[Code]......
I have two RV180W's which are excellent units in almost all respects. The one really noticeable problem is that when I have a power outage (which I have quite a lot in rural France) my RV180W does not automatically restart when the power is restored. Is it not possible to fix this in the next firmware upgrade, or have I missed something in the router menu/setup which I should have set.....?
View 1 Replies View RelatedI've got the power cut while PC was running (w7). After rebooting I'm not able to connect to the internet anymore.
In Device Manager, under Network Adapters there is a "Realtek PCIe GBE..." device properly installed. But under Other Devices there are now more entries with exclamation mark:
- Network controller
- Multimedia controller
- PCI Communication controller
etc
I tried updating the drivers, then deleting and reinstalling but no success so far. Still can't connect to the internet. The browser can see the router, at 192.168.1.1 I don't know where the problem is.
We have several SF-300-48P switches, eveytime there is a power failure the switches need to reboot 2 or 3 times before they are able to route packets again.
View 1 Replies View RelatedWe have cisco wlc 2125 with 13 AP 1131g. All works good. But after power failure one AP can not join to controller, only reset work to recover connection AP to WLC. Additionally, we don't have access to rs-232 port on AP. In this moment on WLC we can see DISCOVERY request from AP and response from WLC to AP, but AP don't send JOIN to controller.
View 2 Replies View RelatedI have a WS-C6509-E (R7000) and am trying to implement some proactive monitoring for environmental alerts. What is the output from a Power Supply failure for the following “sh log” “sh environment alarm”.
View 1 Replies View RelatedI'm having the following issue with a couple of 1231's.
Some overall config info first:
This is a small office with 2x Catalyst 2950 (24-port, no PoE) switches and 4 AP1231G (autonomous). The APs get PoE from a PWRINJ3 each. The injectors are powered by the AP power supplies. Injectors and power supplies are mounted in the patch closet.
The 2 switches are connected together over 4 ports (20-23 on each switch), these ports are set to 1Q Trunk mode.
The APs are connected to the switches, 2 to each switch, on port 1-2. These ports again are configured as 1Q Trunk.
APs are connected to the switch as follows:
[switch] <- patch cable-> [injector] <- patch cable -> [patch panel] <- static cabling -> [outlet] <- patch cable -> [AP]
All this has been working without problems for a number of years.
A few weeks back, AP2 did not restart after a power cut (everything else did). All LEDs are off, port on switch has no LEDs lit. I did not get around to investigating this furtehr until last week. I unmounted (failed) AP2, took it to the spot where (working) AP3 hangs, and plugged it to the cable of AP3. AP2 came to life immediately. I unplugged it and plugged AP3 back in, which restarted immediately.
So I suspect a power supply issue on AP2. I took the injector and power supply that fed AP2 out of the patch closet. When connecting AP2 directly to the power supply, it came to life immediately. So I figure the injector is defective.
On the same day, I notice AP4 is also dead (again all LEDs off, no idea how long, could have been that day or could have been a few days - it has definitely been working after the power cut that appeared to have killed AP2).
So I order 2 new PWRINJ3s and for good measure 2 new power supplies. Later that day, I took the injector and power supply that fed AP4 out of the patch closet. When I try this combination (AP4, injector4 and P/S4), and connect it to a different wall outlet (and therefore a different port -16 - on the switch) IT WORKS! Should have triggered questions, but did not immediately.
Last Thursday I got the new injectors and power supplies. So I take one of each, hook them upto AP2 at my desk, and AP2 starts up. So I mount new injector2 and new P/S2 in the patch closet, put AP2 back in its place, connect all the cables - NOTHING. AP2 does not start. The "power" LED on the injecvtor lights up green, the "device status" LED remains off. I take AP2, new injector2 and new P/S2 to my desk, hook them upto a wall outlet (connected to switch port 17). AP2 starts immediately.
Meanwhile AP3 has (also) stopped working (no LEDs on at all). As far as I can tell, it stopped working after I briefly disconnected (and reconnected) the patch cable between injector3 and the patch panel in the patch closet. The LEDs on switch port 1 are off.
I have since tried to power cycle both switches (took power off both, waited a while, poewerd both back on). No change.
PS: the APs ran firmware 12.3(8)-JA until recently. AP1, AP3 and AP4 were upgraded to 12.3(8)-JEE after the the power cut that took AP2 out. THis is when I found out AP2 was dead. AP2 was still on 12.3(8)-JA. It was upgraded to 12.3(8)-JEE last week when it was on direct power on my desk.
We had power failure catalyst 6509 and after the device boot up ssh does not work any more below is error messages
line con 0
access-class 90 out
logging synchronous
[Code]....
Thinking back, about a month ago I updated the firmware (I can't check version at the moment). The switch has been working fine since then. Today I needed to move some power cables and the switch lost power. Now ALL of the LED lights are flashing green and I can't access the switch. I've tried setting a static IP on my laptop to 192.168.1.20, mask 255.255.255.0, and accessing the switch on 192.168.1.254, but there's no response. I've tried holding in the reset button for at least 30 seconds while the switch is powered on, AND while powering it on. None of that has worked. Also when I first power it on, the system LED flashes orange very quickly for a second or so, then all of the LEDS start flashing green.
View 5 Replies View RelatedAfter a recent power outage while my PC was in sleep mode, I don't have wired (Ethernet) connectivity.
I have new Dimension E510XP Media Center Edition, Version 2002, SP3 ver had an issue with wired connectivity on this PC after coming out of sleep mode. Of course, the power failure was unusual.
Observations:
- ipconfig /all shows that I have an IP address
- I can ping the DHCP server listed in ipconfig /all and I also can ping google.com.
- I was going to go a restore point set before the power outage. But, somehow system restore had gotten turned off. Oh, well. I did go ahead and turn system restore back on.
Things I've already tried that did not solve the issue:
- Reboot
- Uninstall/reinstall the network adapter driver. Device Manager says the network adapter card is working properly.
- Looked for an updated network adapter driver on Dell's website. Turns out that I have the latest driver already.
- Followed many of the steps from Microsoft at [URL]
- Checked McAfee Security Center firewall permissions list to see if something got changed. Everything looked okay. Also disabled the firewall just to be sure,
- Disabled SafeEyes internet filter.
- Reset the router. Also swapped router ports with a known good PC. The known good PC still had connectivity, the affected PC (the E510) did not.
Missing local area connection icon in network connection after power failure?
View 1 Replies View RelatedI have a switch 3560v2 with an IOS 12.2(50) SE1.All the lights ON and console error message below:POST: inline power post failed for port 0 up to port 15.Then, the system hanged and all lights (indicator) ON.
View 5 Replies View Related1、the router power led's emitting light very weak ,
2、client pc cannot get ip from connected router
these error perhaps happened after a plug power jack action. Dc-dc chip is ME5513,the voltage on its pin4 is about 11.94V,and the voltage on following electrolytic capacitor is 3.3V,its seem normal.
I have a ~3 month old e1000 v2. In the last 24 hours it appears to have died, all 4 ethernet lights plus the power light and the one to it's left are on continuously. Before I dispose of it, does anyone know if this really is a hardware fail or is there some way to recover it? I've tried a few resets, power cycles and leaving it off for a few hours in the hopes that would bring it back to life but to no avail.
View 5 Replies View RelatedI am receiving the following error on 3750 stack switches. have already verified the power status and found ok.
IOS used: Cisco IOS Software, C3750E Software (C3750E-UNIVERSALK9-M), Version 12.2(55)SE3, RELEASE SOFTWARE (fc1)
211540: Jun 10 10:45:17.935 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS: Switch 4's power stack has unbalanced power supplies
211541: Jun 10 10:46:18.045 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS:
[Code]....
After stacking two 3750X switches, with four equal power-supply's, with StackWise and PowerStack , still got the next message every few hours %PLATFORM_ENV-1-FRU_PS_ACCESS: FRU Power Supply is not responding (gn4m-rt1p08-04-2)( note that the message revers to the second switch in the stack ) although the stackwise and powerstack on the switches is oke and are working correctly. !
Config : Stack-power in power-sharing mode/strict With CLI on the switch : All the power supply's and stack-power details, prio look OK.
Only: LMS prime /inventory/cisco-view/configure/power supply status result : some power supply's are marked as disabled.with the command > power supply 2 slot a off/on I manage to get the status back to "normal", but after a few hours some power supply's are again marked as "disabled".
Looks like SNMP en IOS difference from opinion.
Hardware
WS-C3750X-24S-S
C3KX-PWR-350WAC
Software
15.0(2)SE
C3750E-UNIVERSALK9-M
I keep getting alerts from our WCS stating that our 1252s are drawing low power. Now I am aware that they require enhanced PoE (up to 20W) but as we only have standard PoE in that building we purchased the 1252 series power injectors to go with them.
However, even with the correct power injectors the WCS still reports the draws low power error.
Is this a bug? Running WCS 7.0.172 at the moment.
Forgot to say we are using the PWR-INJ4 and the injector status is enabled and you see the injector MAC address when you drill in to the AP status.
We have two switches of the same model (WS-C3560-48PS-S) that are not providing PoE. I'm trying to remotely determine what the cause of the issue is.
Here is some output.
Hostname#show power inlineAvailable:0.0(w) Used:0.0(w) Remaining:0.0(w)
Interface Admin Oper Power Device Class Max (Watts)--------- ------ ---------- ------- ------------------- ----- ----Fa0/1 auto off 0.0 n/a n/a 15.4Fa0/2 auto off 0.0 n/a n/a 15.4Fa0/3 auto off 0.0 n/a n/a 15.4Fa0/4 auto off 0.0 n/a n/a 15.4Fa0/5 auto off 0.0 n/a n/a 15.4Fa0/6 auto off 0.0 n/a n/a 15.4Fa0/7 auto off 0.0 n/a n/a 15.4Fa0/8 auto off 0.0 n/a n/a 15.4Fa0/9 auto off 0.0 n/a n/a 15.4Fa0/10 auto off 0.0 n/a n/a 15.4(code)
I have a 6500 chassis with 2 power supplies. At the moment I am using the default configuration:
power-redudancy mode redundant
The problem is that an inserted module is in "power deny" state due too insufficient power.
I know, that It's not a good idea to change into combined mode (loss of redundancy), but my customers requested this anyway.
So I will change to combined mode. So here's the 1 million dollar question: "Which modules will go into power deny, if one of my power supplies fails?"
The 6500 config guide states:
"Power supply is removed withredundancy disabled
• System log and syslog messages are generated.
• System power is decreased to the power capability of one supply.
• If there is not enough power for all previously powered-up modules, some modulesare powered down and marked as power-deny in the show power oper state field."
Well, do you know if there's any way to configure some kind of priority? E.g. I definetly don't want by 10Gig Module or WiSM module to be in power deny. Can i statically make sure, those module will be powered on for sure? Like: "power enable module slot_number" How is this calculated? Or is random?
In a stand alone 3750x switch configuration, can the secondary power supply only act as a redundant power supply (active/standby), or can it become a "pool" of power similar to power sharing mode for StackPower (somewhat active/active)? I understand there is no stack involved here but I'm curious if this functionality is possible.
View 1 Replies View RelatedIs there a way through the CLI to have the ASA 5515-x power back on after a power failure? Currently, the only way to restore power is to press the power button. The X series does not have a power switch the same as the 5500 series.
View 1 Replies View RelatedMy ASA 5505 getting pretty hot after a while and so I used a wattmeter to find out what´s happening.
260 watts is quite a lot if the device is running in idle mode and has no active device attached nor any config has been installed.
What's your experience of the ASA 5505 power consumption ?
I have three pairs of ASA5510 firewalls, each pair configured as a failover pair. When each pair boots up, even if I boot up the primary first, when they are both up and the primary/active syncs to the secondary/standby, the primary always switches to standby and the secondary thus becomes active.
What would cause this? It happens on all three pairs. Does failover look for the highest ID or IP address to determine which of the pair will be active?
I'm looking to make a possible configuration for a customer. They need a device to provide :- firewalling- bandwidth limiting based on protocols, IP, users- web content filtering- good reporting to see which device/users are consuming most of the bandwidth.I used to use cisco ASA as firewall but it's a while I last installed on and I'm nt uptodate which current state.So I thought of using an ASA 5512-X but I'd like to know if it comply with all the requirements .Most important being the reporting and bandwidth limiting capability. It would be great to have some configuration example regarding bandwidth management.
View 1 Replies View RelatedI have a windows 2003 server and an ASA 5512
I'm trying to use SSLVPN and it was all working, and I don't believe any configs on either box have been changed.
On Friday people were connecting, but now I get a message "Login Error" in the browser. In the ASDM home 'latest ADSM Syslog Messsages' I get "AAA authentication server not accessible", followed by two messsages AAA Marking LDAP server in group as FAILED AAA Marking LDAP server in group as ACTIVE
When I go to configuration --> Remote Access VPN --> AAA/Local Users AAA server groups and click on my RADIUS server and click Test, it takes a while and says ERROR: AD agent Server not responding: No error
If I stop my IAS server on my Windows box i get the same error but much more quickly.
I have a sonciwall set up doing the same thing, and RADIUS seems to work happily, so I don't think it's the server config...
My collegue and I have been trying to figure out why we are unable to get this ASA to NAT Overload correctly. I'm sure it is something stupid, and the config may have gotten a little dirty as we tried to change options and make it work. FYI, we can ssh from the WAN into the device to configure it. It is communicating externally, but it isn't natting.
ASA Version 8.6(1)2
!
hostname ASA5512-X-Remote
enable password ********** encrypted
passwd ********** encrypted
names(code)
I have a customer who needs a 5512-X set up with two ports on the "Outside" interface and act like a switch on the outside. This is very easy to do with the way the ASA 5505 works just by creating vlans and treating the ports as members of the vlan.
View 3 Replies View RelatedI am having soem difficulty getting documentation and setup procedures for the new ASA 5512-X (or X models in general) firewalls.I know the IPS sensor is a software-based one, but I'm not sure how much different the setup in than with a 5510 and IPS module.
Also, is the IOS upgrade procedure different?
I'm new on this version and I don't know how to create a Monitor/Alarm to detect that a power supply has gone down. I want to send a message.
View 1 Replies View RelatedI'm trying to access our ASA 5512-X via the Management port, but the address https://192.168.1.1/admin can't be displayed.
View 35 Replies View Related