Cisco Switching/Routing :: 3750X / 6509 - Trunking Over Single Mode Fiber
Oct 26, 2011
I'm having a problem with some new gear and can't seem to figure it out. I have a 3750X-48P-S with a C3KX-10G-NM using SFP-10G-LR transceivers and I'm trying to trunk that with a 6509 that has a X2-10G-LR transceiver over single mode fiber. This is not working. Cisco TAC says the SFP+'s that we just got brand new are both bad and we need to order new ones. I find that hard to believe but who knows.
The switch recognized the module and I tested all 4 ports in gigabit mode using GLC-SX-MM transceivers, all worked great. I have the SFP+'s in tengig1/1/1 and 1/1/2 as they should be. There are no other SFP's in the module either.
When I do a sho int tengig1/1/1 and 1/1/2 the media type doesn't show the transceiver that is installed like it does for the GLC-SX-MM ones. Maybe it's not supposed to or maybe it just doesn't recognize them and it's a hardware issue.
View 5 Replies
ADVERTISEMENT
Oct 22, 2011
Prior we only had 62.5u multi mode.I've got 3750x switches and new SM SFP and yellow fiber patch cables. None of my links show connected. No lights and trunk port interfaces show down/down.
Is there a special command you have to do on a port when using SM fiber? Do you think I need cross over fibers?
Also, should I be able to see a laser signal light like MM or is SM a different frequency so it's not as visible as MM?
View 8 Replies
View Related
May 23, 2012
Using SFP-10G-LRM with single mode fiber? We have 1310nm.
View 2 Replies
View Related
Mar 5, 2012
I'm looking for switches that support single mode fiber connections and would like to know if "WS-C3750-FS-S Catalyst 3750 24 100BaseFX + 2 SFP" and "WS-C3750G-12S-S Catalyst 3750 12 SFP" can serve the purpose?
View 6 Replies
View Related
Jul 18, 2012
The module WS-X4306, support fibber fiber single mode ó fiber multi mode? what GBIC is for fiber single mode or fiber multi mode?
View 1 Replies
View Related
Feb 8, 2012
We've just purchased a WS-C3750-24FS-S, only to find that the 100baseFX ports will not work over Single Mode fibre, backhaul links. Any way or a device that convert from MM to SM?
View 2 Replies
View Related
Aug 4, 2012
connecting a Cisco 3945 Router to an Ethernet WAN Link. The service provider has provided a 100M Ethernet Single Mode Fiber handoff to the customer premises with SC Connector. The CPE configuration proposed for this setup is like this. [code]
Since the SFP has LC Connector, i suppose i need to have an SC-LC Cable for connecting the Ethernet link. Do i need anything else, apart from above?
View 1 Replies
View Related
Apr 10, 2013
Attempting to trunk an Avaya POE switch to a Cisco 3750X switch. Here's the Cisco port config: [code]
Cannot PING Avaya switch at 10.89.0.5. I have Cisco switches at .1,.2 and .3. I can PING those and access them. Any additional config needed on Cisco trunk port?
View 1 Replies
View Related
Apr 29, 2013
I am working on a project to connect 2 switch stacks via 10 Gb fiber. I am told that the 3750Xs do not natively receive the 10 GB SFPs. What part numbers do i need to order to make this work? Is there any IOS image requirements?
View 14 Replies
View Related
Mar 18, 2013
I have 3 Data centres which I am linking up via Single Mode Single Strand Fibre.The switches at each data centre are WS-C4948-E
-Distance between Data Centre 1 and Data Centre 2 is 60km single mode single strand
-Distance between Data Centre 2 and Data Centre 3 is 70km single mode single strand
What type of SFP do I need to use in each Data Centre for the WS-C4948-E switches for these distances.
View 1 Replies
View Related
Jun 4, 2013
I'm working with a customer who has an SGE2000P and a Catalyst 2960 to setup and configure a single mode fiber link. The SGE2000P has an MFELX1 fiber GBIC and the 2960 has a GLC-LH-SMD GBIC. When I have the customer plug in his fiber, there is a power light that comes on on the MFELX1 GBIC. Neither GBICs/switches show that a link or activity is occurring, but the presence of that light makes me think that they are connecting somehow. Are these two switches/GBICs compatible?
View 1 Replies
View Related
May 14, 2012
I have a 7206vxr with a NPE-G1 card in it. I am planning to add some PA-GE card with a ws-g5486 to light single mode Gigabit dark fibre.
it seems that users are experiencing throughput of around 200Mbps. Is this per card, or for the entire chasis? I have 6 free slots, if i were to fill 3 of them up with PA-GE card would i get 200Mbps on each card ?
View 3 Replies
View Related
Nov 30, 2012
I have a requirement to connect two 3750 switch with 10G speed between two sites with 150km distance. We will lay-out our own fiber (48 core) between two sites. I just want to consult the following:
1. Could i use two core switch 6500 with single mode fiber as a transport equipment?
2. Or i need to use SDH equipment because of the distance concern? If so do i need a repeater?Could i use Cisco Metro Core ONS, which one?
3. Any other option to achieve this requirement?
View 4 Replies
View Related
Mar 8, 2012
I have a 3750X 24 port switch (with NM-1G network module) running IOS 15.0(1). Is there any benefit or reason to plug in the included Stack Wise cable and loop it back to itself in a single switch installation?
I don't see any recommendation in the documentation. The data sheet indicates a single switch is a non-blocking device so I'd think there's no bandwidth advantage like there is when connecting an actual multi-switch stack and needing to close the loop for the full 32 Gbps stack bandwidth.
View 2 Replies
View Related
Apr 27, 2013
I have the following connectivity :Nexus(7004) - M1 8Port card with x2-10GB-SR <----------------------> 6509 -- 6704 card -- xenpak-10GB-SR ,The fiber link is not coming up.
View 4 Replies
View Related
Jul 10, 2012
Can I use the SFP-10G-SR 10g interface woth Multi - Mode fiber?
View 3 Replies
View Related
Jan 6, 2012
below is the current config of link that is already up. I need to add another fiber redundant link between 6509 and 2960 stack. How to work on config Spanning side by not taking 6509 down after the change. 6509 is in distribution.
---------------X-ALPHA-IDF-1FORMS-2960S-0# (SIDE)
!interface GigabitEthernet1/0/52description X-ALPHA-F-6509-0 uplinkswitchport trunk native vlan 18switchport mode trunksrr-queue bandwidth share 1 50 30 19priority-queue out mls qos trust dscpmacro description cisco-routerauto qos trust spanning-tree portfast disablespanning-tree guard loopip dhcp snooping trust!
-----------------X-ALPHA-F-6509-0# (SIDE)
!interface GigabitEthernet3/10description 1st floor POC2 Forms IDFswitchportswitchport trunk encapsulation dot1qswitchport trunk native vlan 18switchport mode trunkno ip addressmls qos trust dscpspanning-tree guard loop!
View 1 Replies
View Related
Apr 2, 2013
I am trying to convince our Technical Lead that dual VSL links between our 6509-E chassis is a VERY good idea but he is fully convinced that the setup will work perfectly fine with only one VSL link. As I do agree that we can do this, I am looking for more concrete evidence that shows this would be a bad setup.
I know that we will lose the High Availably that comes with VSS, what I don't know is what will happen to all of the downstream switches that are connected and what will happen to the two 6509-E chassis..
View 5 Replies
View Related
Jan 2, 2012
I am doing an small project, I have to connect 4 cisco switches SF 302-08 (1 GBIC each one) to a core switch SGE 2000 (4 GBICs). Because of cable length I have go connect all 5 switches with fiber. The fiber termination is multimode LC duplex. My confusion is on the mini GBICs. There is compatibilities issues i been reading. [code]
View 3 Replies
View Related
May 21, 2013
Has anyone configured Layer 3 port channel on Cisco 6509 switches which are connected over dark fiber between two buildings?
View 3 Replies
View Related
Dec 2, 2012
We have a project in which we are using 34 Cisco SG200-18's each with a MGBLX1 (LC Single Mode Fiber) SFP mini-GBIC.All the fiber's come back to one building where we must "bridge" all 34 fiber connections. What hardware should be used to accomplish this? A L2 switch? For example, a 12 port SFP Switch with Fiber SFP's accepting the first 12 fiber connections, then other switch with SFP for the next 12 and so on, until there is a overall capacity of 36 and having patch cables between the 3 switches?
what cisco or non cisco hardware would work with these SF200-18's to accomplish this?
View 9 Replies
View Related
Nov 18, 2012
Two Cisco 3750X can be stacked together to ensure redundancy.Is the attached topology feasible for access layer redundancy?
View 5 Replies
View Related
Oct 11, 2012
I have a new building to add to our campus and I have been encouraged to run single mode fiber. All of my other buildings are connected with multi-mode fiber. I just want to make sure i will not have an issue if I run single mode to the new building with SM SFP's.
View 2 Replies
View Related
May 29, 2013
I have a stack of 8 3750x switches connected via Stackwise. In addition, I have these switches configured as two Powerstacks. When I look at the Powerstacks, they are showing as being in power-sharing mode. When I look at the individual switches, they show as standalone. Right now, I have 1 switch in each powerstack that has two power supplies, and then the other three have a single power supply. Below is the output for "Show stack-power detail" as well as the Powerstack configurations.
Power Stack Stack Stack Total Rsvd Alloc Unused Num NumName Mode Topolgy Pwr(W) Pwr(W) Pwr(W) Pwr(W) SW PS-------------------- ------ ------- ------ ------ ------ ------ --- ---Powerstack_1 SP-PS Ring 2145 45 570 1530 3 3Powerstack_2 SP-PS Ring 2860 60 760 2040 4 4Powerstack_1-1 SP-PS Stndaln 1430 520 190 720 1 2
Power stack name: Powerstack_1 Stack mode: Power sharing Stack topology: Ring Switch 4: Power budget: 700 Power allocated: 190 Low port priority value: 20 High port
[code].....
View 1 Replies
View Related
Jun 19, 2012
I'm trying to get an IP_ADDR set on the management port in SWITCH: mode but for some reason the port seems disabled. PC shows connection unplugged. MGMT_INIT is not a valid command (not listed under '?' ). Bootloader version is 12.2(53R)SE2 FC1.
View 4 Replies
View Related
Jun 4, 2012
I am troubleshooting a fiber connectivity issue.Now I have two switches, one is 3750, and another is small biz 300 series switch. Both switch has a single mode smf gbic. Now I have two swtiches face to face and connect with a single mode cable. Do you think if I would get a link light on? Both ports are no shutdown.
View 3 Replies
View Related
Oct 4, 2012
I am struggling to find an SFP transceiver, single mode, that operates at 100Mbps in a 1000Mbps port in an ME3600 or ME3800.
View 5 Replies
View Related
Dec 16, 2012
I have 6509 E. Actually what happen it last 3-4 times it reload its self and got stuck in rommon mode, i tried to boot it with boot by connecting a console cable on supervisor 720 2b. What and where is problem and why is stuck in rommon after reload.
View 11 Replies
View Related
Mar 25, 2012
My current production network is setup using VTP in Client mode, and I am looking to enable VTP Transparent so I can enable the extended VLANs. My main question would be, would enabling VTP Transparent on my 6509 affect all of the access switches it is connected to? And if so, would changing all of the access switches to VTP Transparent allow them to regain connectivity quickly with little downtime? Or is there another way that I should be handling this situation to enable the extended VLANs?
View 2 Replies
View Related
Jan 14, 2013
I'm working at a company that has several 6509 switches running CatOS. They have two of the 6509's running in vtp server mode and the rest as clients. I set up a new vlan from one of the vtp servers and it propagated out. The problem comes when I try to assign a port on one of the vtp clients to this new vlan. It gives me an error that the switch must be in vtp server mode to add/delete vlans. I'm not trying to add/or delete a vlan just trying to add a port into an existing vlan. I'm hesitant to put the switch in vtp server mode. Is this a CatOS thing or is there a specific command to accomplish this?
View 5 Replies
View Related
Nov 28, 2012
We have a cisco catalyst 6509 with Supervisor Engine . After power outage, the switch always start in Rommon mode. Configuration register is 0X2102, we want to it always start in normal mode. What should i do?
View 3 Replies
View Related
Jun 11, 2012
We are facing to an annoying issue. We have a 6509 running in Catos 8.3(4) with WS-X6548-GE-TX, WS-X6348-RJ-45 and WS-X6148-RJ-45. When we configure the mode in auto negotiation, it comes up in half duplex. We need to configure the speed mode at 100Mbit/Full to make it work. But if the chassis or port restarts (not the server), the link becomes half duplex. This happens only on module in Gigabyte like WS-X6548-GE-TX.
Cable have been replaced but does not work. It is not happened on another chassis running on IOS 12.2(18)SXF17b with WS-X6548-GE-TX.
View 4 Replies
View Related
Oct 23, 2011
What is PIM? give me an example when I will use and not use the PIM command.
View 4 Replies
View Related