Cisco Switching/Routing :: 3750x / Stackpower Switches Show In Standalone Mode?
May 29, 2013
I have a stack of 8 3750x switches connected via Stackwise. In addition, I have these switches configured as two Powerstacks. When I look at the Powerstacks, they are showing as being in power-sharing mode. When I look at the individual switches, they show as standalone. Right now, I have 1 switch in each powerstack that has two power supplies, and then the other three have a single power supply. Below is the output for "Show stack-power detail" as well as the Powerstack configurations.
Power Stack Stack Stack Total Rsvd Alloc Unused Num NumName Mode Topolgy Pwr(W) Pwr(W) Pwr(W) Pwr(W) SW PS-------------------- ------ ------- ------ ------ ------ ------ --- ---Powerstack_1 SP-PS Ring 2145 45 570 1530 3 3Powerstack_2 SP-PS Ring 2860 60 760 2040 4 4Powerstack_1-1 SP-PS Stndaln 1430 520 190 720 1 2
Power stack name: Powerstack_1 Stack mode: Power sharing Stack topology: Ring Switch 4: Power budget: 700 Power allocated: 190 Low port priority value: 20 High port
[code].....
View 1 Replies
ADVERTISEMENT
Mar 18, 2012
I can run the Cisco AIR-LAP1142n-a-k9 access point in standalone mode? I don't want it to look for a controller when it boots up.
View 3 Replies
View Related
Sep 3, 2012
I did a sh inv on my newly built 2x Cat 3750X + Cat 3750-24FS stack running 12.2(58)SE2). It only showed 3 of the 4 Cat 3750X PSUs - Sw1 PSU 0, Sw2 PSU 0 and Sw2 PSU 1.
Switch#sh invNAME: "1", DESCR: "WS-C3750X-24"PID: WS-C3750X-24T-S , VID: V02 , SN: FDO*******D
NAME: "Switch 1 - Power Supply 0", DESCR: "FRU Power Supply"PID: C3KX-PWR-350WAC , VID: V01D , SN: DTN1533L00N
NAME: "2", DESCR: "WS-C3750X-24"PID: WS-C3750X-24T-S , VID: V02 , SN: FDO*******6
NAME: "Switch 2 - Power Supply 0", DESCR: "FRU Power Supply"PID: C3KX-PWR-350WAC , VID: V01D , SN: DTN1533L08M(code)
View 8 Replies
View Related
Oct 22, 2011
Prior we only had 62.5u multi mode.I've got 3750x switches and new SM SFP and yellow fiber patch cables. None of my links show connected. No lights and trunk port interfaces show down/down.
Is there a special command you have to do on a port when using SM fiber? Do you think I need cross over fibers?
Also, should I be able to see a laser signal light like MM or is SM a different frequency so it's not as visible as MM?
View 8 Replies
View Related
Feb 2, 2012
We just received two Catalyst 3750X switches. Cisco's documentation provides cabling installs for StackPower in a three or more switch example. Need to clarify the cabling of the two cables between two switches? Having two cables with green and yellow on either side and a switch with both colors signified beside it is a little confusing especially when considering electricity.
View 1 Replies
View Related
Feb 27, 2013
I am looking for 10 GE copper 24 ports switch. After any time I come N2K-C2232TM-10GE. However, this switch is fabric extender and it is used with Nexus 5K series switches.
My question is Can I use this Nexus 2K standalone as other L2 switches?
View 4 Replies
View Related
Nov 18, 2012
Two Cisco 3750X can be stacked together to ensure redundancy.Is the attached topology feasible for access layer redundancy?
View 5 Replies
View Related
Jun 19, 2012
I'm trying to get an IP_ADDR set on the management port in SWITCH: mode but for some reason the port seems disabled. PC shows connection unplugged. MGMT_INIT is not a valid command (not listed under '?' ). Bootloader version is 12.2(53R)SE2 FC1.
View 4 Replies
View Related
Oct 26, 2011
I'm having a problem with some new gear and can't seem to figure it out. I have a 3750X-48P-S with a C3KX-10G-NM using SFP-10G-LR transceivers and I'm trying to trunk that with a 6509 that has a X2-10G-LR transceiver over single mode fiber. This is not working. Cisco TAC says the SFP+'s that we just got brand new are both bad and we need to order new ones. I find that hard to believe but who knows.
The switch recognized the module and I tested all 4 ports in gigabit mode using GLC-SX-MM transceivers, all worked great. I have the SFP+'s in tengig1/1/1 and 1/1/2 as they should be. There are no other SFP's in the module either.
When I do a sho int tengig1/1/1 and 1/1/2 the media type doesn't show the transceiver that is installed like it does for the GLC-SX-MM ones. Maybe it's not supposed to or maybe it just doesn't recognize them and it's a hardware issue.
View 5 Replies
View Related
Nov 26, 2012
We recently purchased two 3750-X 48-port switches. We are in the process of connecting the Data Stack and StackPower cables. The question we have is what is the recommended Data Stack and Power Stack cable configuration if you only have two switches? All of the documentation that we have seen is for three or more switches.
Data Stack: Our assumption is that we will go from Stack 1 on the top switch to Stack 2 on the bottom switch. Do we need to then connect another cable from Stack 2 on the top switch to Stack 1 on the bottom switch? We would think not, but figure we should check. We plan on adding another three in the next budget year, which starts in May.
StackPower: Our assumption is that we will go from S-PWR on the top switch to S-PWR XPS on the bottom switch. Do we need to then connect another cable from S-PWR XPS on the top switch to S-PWR on the bottom switch? We would think not, but figure we should check.
View 1 Replies
View Related
Aug 22, 2012
As I understand Cisco Catalyst 3750-x supports stackwise and stackpower technology.Do I need to purchase a seperate module to enable stackwise and stackpower? Or are stackwise and stackpower modules included be default on the switch already?
View 4 Replies
View Related
Aug 19, 2012
Can I implement MACsec betwen two Cisoc 3750X using the C3KX-NM-1G? 3750x (C3KX-NM-1G) -------------------MMF------------------(C3KX-NM-1G) 3750x.
View 1 Replies
View Related
Jan 25, 2012
How to get vlans working properly between sub-interfaces on a ASA and a trunk port on a switch.There seems to be issue with the VLAN's being assigned to the correct VLAN and this information being properly sent to the ASA over the trunk.
We seem to be unable to ping most of the interfaces except for one on the switch. Sometimes if we are lucky we are able to ping a host on a different vlan that is on the switch. This seems sparadic at best.
Logs on the ASA show traffic does not seem to be assigned properly to the correct sub interface. We have access rules on the ASA disallowing traffic not part of the same vlan. For example you will see networkA blocked on networkB when it really should be directed through networkA's sub interface.
Any example commands for the ASA and Switch for at least the basic requirements to enable all the VLAN's to communicate properly with the ASA?
View 5 Replies
View Related
Dec 27, 2012
I'm trying to get some clarity on power stacking 3750X switches. I have a new stack of 6 switches. I know I can only have 4 in a power stack and all 6 in the data stack with a max of 8. I'm trying to find the proper way to connect the power stack cables for the 4 switch power stack.
View 1 Replies
View Related
Sep 4, 2012
I need to know if is possible to do a LACP using 2 x 10GB between 3750X and 2960S (WS-C2960S-48LPD-L) switches.
View 1 Replies
View Related
Apr 9, 2013
What is the difference between IP Base and Universal for 3750X switches?
View 2 Replies
View Related
Aug 16, 2012
I'm building a wired closet to aggregate user's connections, Im planning to have 5x 3750X stacked switches and there is a need to run EIGRP, I'm thinking to order one switch with IP service image while the rest will run IP base image, is it workable scenario and what are the drawbacks of such combination of images ?
View 5 Replies
View Related
Feb 25, 2013
I have two 3750x stacked switches , both with the latest firmware on them. I enter the configuration onto one switch and it obviously copies over onto the other switch. Although in the configuration I have both a console username and password and an enable password, when I try to log onto the initial switch that I entered the configuration on, I am prompted for a username and password, which works fine, but when I try to enter enable mode i get an error stating that no password has been set. However when logging onto the other switch I am not prompted for a username or password but when I try to enter enable mode I am prompted for a password and can access it with no problems.
View 1 Replies
View Related
Dec 11, 2012
We purchased a number of 3750X 48 and 24 port switches for the College Campus. Am finally getting around to getting them inserted on the network. Working with a WS-3750X-48PF-S and a WS-3750X-24P-L. Have them stacked with the 10Gb uplink on the 48 port switch. Have not been having fun.In the boot sequence, the switches recognize they are stacked, but as soon as they finish boot, I get the message on the 48 port switch: “Stack Port 1 Switch 1 has changed to state down.” Then “Stack Port 2 Switch1 has changed to state down.” Am noticing that I have a message preceding that: “Major version mismatch with stack neighbor.”The 48 port is running c3750e-universalk9-mz.150-1.SE3, HBOOT 12.2(53r)SE2.The 24 port is running c3750e-unversalk9-mz.122-55.SE3, HBOOT 12.2(53r)SE2Most of our 3750X and older switches are running 122-55 or 122.58 code. IP base or Universal. There is speculation that the problem is the 24 Port is Lan base, as the part number might indicate. (WS-C3750X-24-P-L.... I think that is the part number) and the 48 is IP base. Both switches are Universal, and my understanding is that they don't care about LAN or IP Base until you enable a function that falls in the IP Base domain. Then I have to call Cisco Licensing.For these switches, LAN Base is fine, based on the boot message, I feel the real problem is 122-55 versus 150-1 in the stack. So.. the question is: Do I downgrade the 48 port to match what we have in our environment, and what is on the 24 port switch. Or... Upgrade the 24 port switch to match the 48 port switch and have an installation that is not consistent with our environment? I do have two more edge closets to install with this purchase of 3750X 48 port switches.
View 2 Replies
View Related
Mar 28, 2012
In my office we bought 7 cisco 3750X - 48PS switches. We configured Data Stacking between those switches. We also want to configure Power Stacking between those 7 devices.
I found in the Data Sheet that we can only configure 4 devices in power stacking at a time. If it is like that how to configure the rest of 3 devices. Need configuring power stacking between those devices in a better way..
power stack cable part no we have is
CAB-SPWR-30CM
View 2 Replies
View Related
May 9, 2013
We have a remote site that is using 3750X switches as layer 2 switches back to our home site. The uplink port is showing dropped packets but the utilization on the link is never about 10%. We have a 100Mb circuit to this site. Our speed tests and iperf tests are not showing any issues that we can see. However the port is still droping packets. It is not dropping at a high rate but they are dropping.
switch#sh platform port-asic stats drop gi1/1/4
Interface Gi1/1/4 TxQueue Drop Statistics Queue 0 Weight 0 Frames 0 Weight 1 Frames 0 Weight 2 Frames 0 Queue 1 Weight 0 Frames 52876 Weight 1 Frames 2 Weight 2 Frames 0 Queue 2 Weight 0 Frames 0 Weight 1 Frames 0 Weight 2 Frames 0 Queue 3 Weight 0 Frames 0 Weight 1 Frames 0 Weight 2 Frames 1330874 Queue 4 Weight 0 Frames 0 Weight 1 Frames 0 Weight 2 Frames 0 Queue 5 Weight 0 Frames 0 Weight 1 Frames 0 Weight 2 Frames 0 Queue 6 Weight 0 Frames 0 Weight 1 Frames 0 Weight 2 Frames 0 Queue 7 Weight 0 Frames 0 Weight 1 Frames 0 Weight 2 Frames 0switch#
Is there a way to capture these dropped packets to see what they are? We do have VOIP phones at the site and are using Qos.
View 5 Replies
View Related
Jul 30, 2011
I'm building a wired closet to aggregate user's connections, Im planning to have 5x 3750X stacked switches and there is a need to run EIGRP, I'm thinking to order one switch with IP service image while the rest will run IP base image, is it workable scenario and what are the drawbacks of such combination of images ?
View 1 Replies
View Related
Jun 7, 2012
I have a bunch of 3750x switches that each have a 10 gig routed link back to a central 4507 (loopback = 172.30.255.255).We carved up a /24 (of course, the /24 doesn't really exist except in our address tracking spreadsheet) into a bunch of /30's for routed WAN links and /32's for loopback addresses.We started on the low end for /30 subnets (ie 172.30.255.0/30, 172.30.255.4/30, etc.).We started at the high end for the /32 loopbacks (ie 172.30.255.255/32, 172.30.255.254/32, etc.)
Well, when I try pinging 172.30.255.255 from the access layer 3750x switches, the 3750x seems to be treating it as a broadcast ping where it lists each member that responds instead of the regular !!!!! response (this makes think something is odd with the 3750x). Of course, only one member responds (the core). But even the core seems to respond with the other end of the /30 instead of the actual /32 loopback (which makes me think something is odd in the core). I could have sworn that I've setup similar topologies without problems (ie, using 10.0.0.0/32, 10.255.255.255/32, etc as loopbacks) and as long as the mask is a /32, it should work.Also, I can ping/ssh to that loopback if my laptop is on a directly connected subnet. But I can't do it from any of the 3750x switches (which are also directly connected).I've double checked for overlapping subnets, but nope. I don't see any. Routing looks fine. The actual /32 is being propagated everywhere properly.
View 3 Replies
View Related
Sep 8, 2012
What are the options avilable to add a cat3560 g switch to a stack of 3750x switches.?is there a connector avilable ?or is it possible to trunk via fiber ? cat 3560 has 4 sfps and 224 10/100/1000 ports with poe. cat 3750 stack has a 10 gb up link . What are the possible options?
View 6 Replies
View Related
Dec 12, 2011
Is there a chart to show what modules will fit what swithches for fiber applications ex 2950 and 3560 switches
View 1 Replies
View Related
Mar 13, 2013
I have configured a vlan interface on a 3750 switch. there is aprox 4Mb active traffic flowing through the interface, but when I do a "show interface vlan (vlanid)" the output show zero bits in and zero bits out. Its a typical L3 config with one IP on the vllan interface acting as the gateway for the VLAN devices. Is this a normal behaviur ? and if so is there any way to get the traffic in/out stats. The end PC/devices are connected to this switch via an L2 TRUNK and I dont have access to the L2 switch on which the actual devices connect. so cant get the real time stats of those interfaces.
View 2 Replies
View Related
May 27, 2012
Facing issue with 2960G switch , where its do not display "logging trap informational " in show running and show startup .where its showing all other levels from 0 to 5 and 7 after configuration and save commands. [code] after config getting saved , it do not shows in show runn or in show startup while for all other levels it do show the config lines .I tried the same on 12.55.SE release also but its same results . Is this a limitaion of this platform, is there any doc explaining the same for reference. [code]
View 1 Replies
View Related
Mar 5, 2012
I'm looking for switches that support single mode fiber connections and would like to know if "WS-C3750-FS-S Catalyst 3750 24 100BaseFX + 2 SFP" and "WS-C3750G-12S-S Catalyst 3750 12 SFP" can serve the purpose?
View 6 Replies
View Related
Mar 27, 2013
I faced with a strange behavior of ME3600.For testing purposes I linked Cat3550 and ME3600 switches via trunk mode. All interfaces are in Up state. But I couldn't ping SVI200 of Cat switch from ME3600 and vice versa. [cde]
This scheme perfectly works with another L3 swithes. For example Catalist3750. I know that ME doesn't support VTP, DTP and so on. Also, I've tried latest software.
View 0 Replies
View Related
Jun 4, 2012
I am troubleshooting a fiber connectivity issue.Now I have two switches, one is 3750, and another is small biz 300 series switch. Both switch has a single mode smf gbic. Now I have two swtiches face to face and connect with a single mode cable. Do you think if I would get a link light on? Both ports are no shutdown.
View 3 Replies
View Related
Feb 20, 2013
I need to support a bunch of security cameras mounted on poles in our parking lot and an IP intercom system mounted on some gates. Because of environmental factors the switches at the poles need to be hardened and the spec from the vendor installing the gear is for GarretCom Industrial unmanaged switches which would make sense.
However when Information Security got wind of this scheme they (probably correctly) are requiring me to secure the ports that these unmanaged switches connect to. I have 2 choices: port security w/ MAC filtering or 802.1x. Because all the devices at the poles and gates support 802.1x and because I may need to go out there to troubleshoot stuff (and will invariably forget to add the MAC of whatever device I am using) I would prefer 802.1X multi-auth mode.
Problem:
When I ran a quick test on a test 3560 running some 15.0.1 code I could get a laptop to connect via 802.1x EAP-TLS successfully if it was directly connected but when I connected the same laptop via a dumb Netgear switch I confiscated from a luser it would not connect. The 3560 error said that the laptop never responded.
Question:
Before I spend a whole lot of time on this, is this something that should work? I don't see any practical use for the feature if it won't however the documentation I am using specifically mentions downstream hubs but I am not sure if they mean real hubs (which I don't think are even made anymore) or if they mean unmanaged switches.
I plan to try a couple of different unmanaged switches tomorrow and digg a little but I would like to know if I am wasting my time on something that will never work or if there is a little gotcha somewhere.
View 2 Replies
View Related
Mar 21, 2012
I have two 5548's in sync mode: I have an existing ACL and I want to add a new line to it, but after I do and try to commit it states the verify failed. [code]
I have to add access list to both switches not in config sync mode.
View 1 Replies
View Related
Feb 18, 2013
I have to set up the AP in a standalone mode to support voice and data traffic through the wireless network. for this, i was trying to look for the config guide so i know how to go about it, but all the doc was refering to controller based setup. i followed this link URL
I have never worked on wireless in a standalone mode, so this is the first time i will be doing it.
View 22 Replies
View Related