Cisco Switching/Routing :: Insert Secondary Power Supply To 3560?

May 22, 2013

while the 3560 switch is running?  Is it hot-pluggable?   
 
WS-C3560X-48P is the switch and I would be adding a C3KX-PWR-1100WAC

View 1 Replies


ADVERTISEMENT

Cisco Switching/Routing :: 3750X Stand Alone Secondary Power Supply Act As Pool Of Power

Apr 4, 2012

In a stand alone 3750x switch configuration, can the secondary power supply only act as a redundant power supply (active/standby), or can it become a "pool" of power similar to power sharing mode for StackPower (somewhat active/active)?  I understand there is no stack involved here but I'm curious if this functionality is possible.

View 1 Replies View Related

Cisco Switching/Routing :: Catalyst 3750X With PoE Secondary Power Supply Options?

Jul 21, 2012

When quoting a Catalyst 3750X with PoE (WS-C3750X-48P-E) the Dynamic Configurator Tool allows to include as the secondary power supply option the Catalyst 3K-X 350W AC Secondary Power Supply (C3KX-PWR-350WAC/2), but the default included primary power supply is the Catalyst 3K-X 715W AC Power Supply (C3KX-PWR-715WAC). My questions are the following:
 
1. Will this combination of power supply work?

2. Will the C3KX-PWR-350WAC/2 be able to power up the switch if the primary power supply of 715W fails?

3. Will the PoE will be lost if the primary power supply fails and only the secondary power supply of 350W keeps working?

4. If this secondary power supply of 350W is not suitable for PoE, why it is available as a secondary power supply option in the Dynamic Configurator Tool for a PoE switch?

View 4 Replies View Related

Cisco Switching/Routing :: Stack-power 3750x / FRU Power Supply Is Not Responding

Sep 4, 2012

After stacking two 3750X switches, with four equal power-supply's, with StackWise and PowerStack , still got the next message every few hours %PLATFORM_ENV-1-FRU_PS_ACCESS: FRU Power Supply is not responding (gn4m-rt1p08-04-2)( note that the message revers to the second switch in the stack ) although the stackwise and powerstack on the switches is oke and are working correctly. !
 
Config  : Stack-power in power-sharing mode/strict With CLI on the switch : All the power supply's and stack-power details, prio look OK.
 
Only: LMS prime /inventory/cisco-view/configure/power supply status  result :  some power supply's are marked as disabled.with the command  > power supply 2 slot a off/on I manage to get the status back to "normal", but after a few hours some power supply's are again marked as "disabled".
 
Looks like SNMP en IOS difference from opinion.
 
Hardware
WS-C3750X-24S-S
C3KX-PWR-350WAC
 
Software
15.0(2)SE
C3750E-UNIVERSALK9-M

View 5 Replies View Related

Cisco Switching/Routing :: 6509 NEB A Power Supply Not Working

Nov 20, 2011

The power supply on 6509 NEB A is not working with me . I have installed only one power supply on the box  WS-CAC-3000W
 
It is showing me that "Input OK , Output fail " from the LCD
 
 I tried with another WS-CAC-3000W , another power source but still same problem .

View 2 Replies View Related

Cisco Switching/Routing :: 2911 / K9 How To Determine If Power Supply Is AC / POE

Mar 12, 2013

I would like to ask if how can we determine by mear physical inspection if the power supply of a CISCO2911/K9 router is AC, POE or DC?  Do we have images of the actual spare power supply?

View 3 Replies View Related

Cisco Switching/Routing :: 6513E Power Supply Recommendations

Jan 25, 2012

Just received our new 6513E chassis and I am setting it up in the lab for testing. For prod we would like to run..
 
1 maybe 2 6704 10 gig cards
3 - 5 6748 cards
1 6724 SFP card

Sup720 setup, possibly upgrading to Sup32's in a few years, Right now for power supplies, I am using 2 WS-CAC-2500W ,But I have to run the supplies in combined mode to get all of the cards online.What power supply should I be looking to purchase for this chassis ?

View 2 Replies View Related

Cisco Switching/Routing :: 6509 Power Supply Incompatible With Fan

Nov 21, 2011

I have a 6509 box with the following modules:

View 4 Replies View Related

Cisco Switching/Routing :: AC Power Supply With PoE For Ethernet Modules In ISR G2

Dec 12, 2012

While configuring PoE Ethernet EHWIC PoE modules with ISR G2 routers Cisco DCT gives a warning to select AC Power Supply with PoE ‘PWR-3900-POE’. Do we need to select the PoE power supply for Enhanced EtherSwitch SM PoE modules also (at present it does nt show any warnings)?

View 1 Replies View Related

Cisco Switching/Routing :: Power Supply Cord For 4500?

Apr 3, 2012

Currently I am using 1000W power supply in Cisco 4500 and I want to upgrade to 2800W power supply.My question is
 
1) Whether I have to change the power cord while upgrading power supply

2)Whether power cord comes along with the Power Supply while ordering from Cisco

View 1 Replies View Related

Cisco Switching/Routing :: 3825 Redundant Power Supply?

Sep 3, 2012

I was wondering if there was a way to disable the RPS in a 3825? When I do a Sho Env All I get the following;

Redundant Power System is present.
RPS is in standby state
Redundant Power System is present.
RPS is in standby state
 
How ever there is no RPS in the system. At least not that I know of. There is only one power supply.

View 4 Replies View Related

Cisco Switching/Routing :: 48VDC Power Supply For 819 4G LTE Router In Q1 2013?

Dec 14, 2012

clarify whether this statement found after table 4 of the Cisco 819 4G router data sheet truly means that there will be a power supply to support 48VDC in Q1 of 2013?  Here is the statement:
 
"* Future external reference for 24V, 52V, and 72V DC for railway applications Q1CY2013"
 
Here is the data sheet source: 
 
[URL] 
 
I would want to power this router from a -48VDC plant, which is common at remote telecom sites.

View 1 Replies View Related

Cisco Switching/Routing :: Finding Specification For 3750x PoE Power Supply?

Jul 11, 2012

Looking at the specs for the 3750 power supply - is the WS-C3750X-48P-S model with the 715W power supply referring to the amount for both power supplies per switch or just one power supply per switch? Meaning, is the 715 a accumulative number or, just the watts of one power supply. I would like to purchase a 3750x PoE switch with redundant power supplies. If this model is not the correct one?give me the model that offers 48 port PoE with redundant power supplies?

View 6 Replies View Related

Cisco Switching/Routing :: Power Supply Error Switch 3750

Dec 3, 2011

power supply problem...?Switch cisco WS-C3750-24P is showing "Unavail" from sh env all.Switch3750#sh env all FAN is OK,TEMPERATURE is OK,SW  PID,Serial#     Status Sys Pwr  PoE Pwr  Watts,Does it means that power supply 1 was removed? failed?,Do you know about another command to see more details?

View 3 Replies View Related

Cisco Switching/Routing :: 4506E Switch Power Supply Upgrade

Dec 8, 2012

I would like to check if it may be possible to hot-upgrade/swap the 4506E power supplies? Based on the configuration guide; I have summarized the steps as follows:

1. Switch has 2 existing power supplies to be upgraded

2. Remove right side/bay 2 power supply and install new power supply

3. At this point; the new power supply will be in err-disabled due to different power supplies on the switch

4. Remove the left side power supply and install new power supply

For item 4; during the removal of the old power supply in bay 1/left side and installation of the new power supply; I am wondering if the switch would lose power even though the new power supply is installed in bay 2?

View 1 Replies View Related

Cisco Switching/Routing :: ASR 1001 - Adding Redundant Power Supply?

Dec 23, 2012

I was wondering if I am able to add a redundant power supply to an asr 1001 router that is in production without losing connectivity or causing any diruption to the Users  - is it hotswappable?

View 1 Replies View Related

Cisco Switching/Routing :: Power Supply Compatibility From 4500 To 6500

May 9, 2013

can I plug power supply from 4500 to 6500? more specifically we have power supply PWR-C45-1300ACV. And we need to place some power supply to 6500, which has only one active module. So 1300 should be enough for it. But we dont know if they are physically compatible, if it is possible to plug. I didnt find this power supply to be officially?

View 4 Replies View Related

Cisco Switching/Routing :: 7606s Power Coming From Single Supply

Apr 6, 2012

Having a strange issue here with an 7606-s chassis equipped with two sup720's, and two regular line cards. There is only one power supply, PWR-2700-AC. I recently builded this setup and powered it on last week for the first time. It ran fine for about 20 minutes while suddenly the chassis powered down.
 
I've checked the back of the chassis and noticed that the power supply had it's 'input ok' and 'power fail' led lit. I toggled the power switch and waited half an hour to power it on again. This time only 1 minute of joy. My first idea was the PSU due to the power fail led so I had it swapped by the supplier for another. Unfortunately, when I powered it on today, it didn't change a thing, still unexpected power downs.
 
So I've checked the following documentation: [URL] and followed the suggestion to power the chassis on without any modules in the slots. So I did that and it ran for 8 minutes only. However, the fan tray did respond properly when I removed the small thermal module in the upper right by increasing the fans to full speed.
 
Following above documentation, it points to the chassis (there is not much left). Now the real question comes, isn't there anything else that could be the cause of this?

View 1 Replies View Related

Cisco Switching/Routing :: 4510 Power Supply Error - PWR-C45-4200ACV

Mar 17, 2013

We are getting below errors on our Cisco 4500 Switche PS after Power Down activity.
 
Switch1
 
------------------ show power detail ------------------
 
Power                                             Fan      Inline
Supply  Model No          Type       Status       Sensor   Status
------  ----------------  ---------  -----------  -------  -------
PS1     PWR-C45-4200ACV   AC 4200W   good         good     good  
PS1-1                                off         
PS1-2                         220V   good        
PS2     PWR-C45-4200ACV   AC 4200W   err-disable  good     good  
PS2-1                         220V   good        
PS2-2                         220V   good        

*** Power Supplies of different type have been detected***
 
00:01:02: %C4K_CHASSIS-3-MIXINPOWERDETECTED: Power supplies in the chassis are of different types (AC/DC) or wattage(code)

View 1 Replies View Related

Cisco Switching/Routing :: Enable Second Power Supply On 3750x Switch

Nov 6, 2012

I have a 3750x 48port POE switch that I installed a second power supply in. But it doesnt power on. Am I supposed to enable it in the switch somewhere? I've plugged it into a couple different outlets so I know that's not the problem.

View 4 Replies View Related

Cisco Switching/Routing :: 8700W Enhanced AC Power Supply With 6513 Chassis

Mar 6, 2013

I understand that 8700W enhanced AC power supply is Compatible with 6-, 9-, and 13- slot chassis
 
Based on 8700W Enhanced PS datasheet, it can be installed into existing Cisco Catalyst 6500 Series Switch chassis: both E- and non-E series Cisco Catalyst 6500 Series Switch chassis.

Can we use 8700W enhanced AC power supply with 6513 externally / internally (within one of the chassis slots like 6513-E ?

View 1 Replies View Related

Cisco Switching/Routing :: RJ45 Uplink / Layer 2 Switch With Dual AC Power Supply?

Dec 3, 2011

I need a L2 switch with dual AC power supply and RJ45 uplink The optin I got was   WS-C3560X-48T-L + C3KX-PWR-350WAC , but the problem is with uplink . There is no RJ45 1G uplink , there is only option for SFP uplink The another option was  WS-C2960G-48TC-L , but there is no dual AC power supply option a good model ( Dual AC power supply , RJ 45 uplink ports (Gig) , with 48 port 100/1000 UTP)

View 3 Replies View Related

Cisco Switching/Routing :: 2960S - Internal Power Supply Show Unavailing When Running Off RPS?

Feb 13, 2012

I have a 2960S connected to an RSP 2300.  The 2960S is currently running off of the RPS, and I would like to switch it back to the internal power supply.  Can I just run "power supply 1 on"?  Will this cause the switch to reboot?  Also I am concerned because when I do a show env power it shows: [code]
 
 Is it normal for the internal power supply to show Unavail when running off RPS?

View 1 Replies View Related

Cisco Switching/Routing :: 3560 - Secondary Network Configuration

Jun 2, 2013

How many secondary network config possible???

Switch - Cat3560
IOS Ver 12.2(50)se5

View 6 Replies View Related

Cisco Switching/Routing :: Routing Secondary Network On 3560 Switch

Jun 4, 2013

I am trying to get my workstation to talk to a workstation on a different sub-net through a Cisco 3560 switch.  The switch is running the following IOS version: [code]
 
My primary network is 172.16.0.0 and I am trying to connect to a device on a 192.168.111.0 sub-net. [code]
 
What would be the best way to get the two workstations talking via the switch?

View 3 Replies View Related

Cisco Switching/Routing :: 2960g-24tc-l Internal Power Supply Pinout / Voltage Check

Feb 25, 2013

I had a bad power surge yesterday that took out a 2960g switch and the APC UPS that it was connected too. when plugged in the fan comes on and the syst light stays amber and the rps, stat, duplex. and speed light stay lit and the port lights for ports 21-24 stay lit. plugging it into the console on boot I cant even see rommon, so i dont think its even booting. I would like to find a pinout and voltage guide for the connector comming off the power supply so I can check the voltages coming off the power supply to tell if it is a bad PSU or if it took out the main board.

View 2 Replies View Related

Cisco Switching/Routing :: What Is Power Consumption Of 3560

Jan 4, 2012

I have 2 x 3560e-24td-s
          2 x ASA5510
          2 x 2821(no modules)
          2 x 2901
 
I'm trying to figure out power draw in Amps for my new cabinet. I looked at the data sheet for the 2821 and it says 3A for the 110V under the row AC Input Current, Would that be accurate if I did that for all the models and then just added up the total?

View 3 Replies View Related

Cisco Switching/Routing :: Switch 3560 Not Giving Out Power?

Sep 26, 2011

I have an issue with a 3560 in my network, after sometimes it fails to give out power to some ip phones,while others are not affected and below is the message i get
 
"Power given, but Power Controller does not report Power Good"

output of sh power inline and sh env all : everything seems to be ok on the switch

#sh power  inline
Available:450.0(w)  Used:48.0(w)  Remaining:402.0(w)
 Interface Admin  Oper       Power   Device              Class Max
                            (Watts)
--------- ------ ---------- ------- ------------------- ----- ----
Gi0/1     auto   off        0.0     n/a                 n/a   15.4
Gi0/2     auto   off        0.0     n/a                 n/a   15.4
Gi0/3     auto   off        0.0     n/a                 n/a   15.4

[code].....
 
It's solved by a reboot of the switch, i could have suspected a power environnment issue but it's the only equipement disturbing in the network.

View 20 Replies View Related

Cisco Switching/Routing :: 3560 Switch Doesn't Provide PoE Power

Mar 9, 2012

I have upgraded my C3560-PS-S switch to the latest IOS version 12(2)55-SE4 and it is not providing PoE anymore? It used to work before this upgrade? I searched Cisco bugtrack and there is bug defined for this IOS/Switch.
 
Switch(config-if)#do show power inline Available:370.0(w)  Used:0.0(w)  Remaining:370.0(w)
 
Interface Admin  Oper       Power   Device              Class Max
                            (Watts)
--------- ------ ---------- ------- ------------------- ----- ----
Fa0/1     auto   off        0.0     n/a                 n/a   15.4
Fa0/2     auto   off        0.0     n/a                 n/a   15.4
Fa0/3     auto   off        0.0     n/a                 n/a   15.4
Fa0/4     auto   off        0.0     n/a                 n/a   15.4
Fa0/5     auto   off        0.0     n/a                 n/a   15.4
Fa0/6     auto   off        0.0     n/a                 n/a   15.4
Fa0/7     auto   off        0.0     n/a                 n/a   15.4
Fa0/8     auto   off        0.0     n/a                 n/a   15.4
Fa0/9     auto   off        0.0     n/a                 n/a   15.4
Fa0/10    auto   off        0.0     n/a                 n/a   15.4
Fa0/11    auto   off        0.0     n/a                 n/a   15.4
Fa0/12    auto   off        0.0     n/a                 n/a   15.4
Fa0/13    auto   off        0.0     n/a                 n/a   15.4
Fa0/14    auto   off        0.0     n/a                 n/a   15.4
Fa0/15    auto   off        0.0     n/a                 n/a   15.4
Fa0/16    auto   off        0.0     n/a                 n/a   15.4
Fa0/17    auto   off        0.0     n/a                 n/a   15.4
Fa0/18    auto   off        0.0     n/a                 n/a   15.4
Fa0/19    auto   off        0.0     n/a                 n/a   15.4
Fa0/20    auto   off        0.0     n/a                 n/a   15.4
Fa0/21    auto   off        0.0     n/a                 n/a   15.4
Fa0/22    auto   off        0.0     n/a                 n/a   15.4
Fa0/23    auto   off        0.0     n/a                 n/a   15.4
Fa0/24    auto    off        0.0     n/a                 n/a   15.4

View 3 Replies View Related

Cisco Switching/Routing :: Catalyst 3560-X Proprietary AC Power Cable

Jul 22, 2012

I just recieved a new 3560-x switch with the C3KX-PWR-715WAC. It looks like Cisco is now using a different AC power cable. Not the StackPower connector, but the standard AC power cable. My data center is setup to supply 208v using C13 power cables. The switch uses a C15 power cable, and comes with a standard NEMA 5 to C13 power cable. Does Cisco make, or officially support a C13 to C15 power cable? Can I still use a 208v power supply with these switches?

I'm using an APC AP8861 power distribution unit, see [URL]

View 1 Replies View Related

Cisco Switching/Routing :: 3560 - Portable Redundant Power System For Catalyst Switches?

May 10, 2012

Does a portable RPS device either from Cisco or another manufacturer exists, that would allow you to move primary power for a switch without causing an outage? I realize that for the Catalyst 3560 for example, you can get an RPS 2300 or 675, but my understanding is that these are made for a more permanent installation, not to mention rather costly.
 
It looks like the RPS 675 is rather inexpensive after all, especially in the secondary market, but still rather large for toting around.

View 1 Replies View Related

Cisco Switching/Routing :: 3560 Port Security Triggers With Valid Mac Address During Power On

Feb 28, 2013

I have 2 3560 switches that are running 12.2(25)SEE2. Port security is enabled on some of the ports. Whenever there is a power failure, when power is restored, 1 port on each switch goes to err-disabled. The mac address that causes this is a valid address for that port. Below is the configuration on one of the ports.

View 1 Replies View Related

Cisco :: Power Supply In LMS 4?

Aug 4, 2011

I'm new on this version and I don't know how to create a Monitor/Alarm to detect that a power supply has gone down. I want to send a message.

View 1 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved