Cisco Switching/Routing :: 2960S - Internal Power Supply Show Unavailing When Running Off RPS?
Feb 13, 2012
I have a 2960S connected to an RSP 2300. The 2960S is currently running off of the RPS, and I would like to switch it back to the internal power supply. Can I just run "power supply 1 on"? Will this cause the switch to reboot? Also I am concerned because when I do a show env power it shows: [code]
Is it normal for the internal power supply to show Unavail when running off RPS?
View 1 Replies
ADVERTISEMENT
Feb 25, 2013
I had a bad power surge yesterday that took out a 2960g switch and the APC UPS that it was connected too. when plugged in the fan comes on and the syst light stays amber and the rps, stat, duplex. and speed light stay lit and the port lights for ports 21-24 stay lit. plugging it into the console on boot I cant even see rommon, so i dont think its even booting. I would like to find a pinout and voltage guide for the connector comming off the power supply so I can check the voltages coming off the power supply to tell if it is a bad PSU or if it took out the main board.
View 2 Replies
View Related
Sep 4, 2012
After stacking two 3750X switches, with four equal power-supply's, with StackWise and PowerStack , still got the next message every few hours %PLATFORM_ENV-1-FRU_PS_ACCESS: FRU Power Supply is not responding (gn4m-rt1p08-04-2)( note that the message revers to the second switch in the stack ) although the stackwise and powerstack on the switches is oke and are working correctly. !
Config : Stack-power in power-sharing mode/strict With CLI on the switch : All the power supply's and stack-power details, prio look OK.
Only: LMS prime /inventory/cisco-view/configure/power supply status result : some power supply's are marked as disabled.with the command > power supply 2 slot a off/on I manage to get the status back to "normal", but after a few hours some power supply's are again marked as "disabled".
Looks like SNMP en IOS difference from opinion.
Hardware
WS-C3750X-24S-S
C3KX-PWR-350WAC
Software
15.0(2)SE
C3750E-UNIVERSALK9-M
View 5 Replies
View Related
Apr 4, 2012
In a stand alone 3750x switch configuration, can the secondary power supply only act as a redundant power supply (active/standby), or can it become a "pool" of power similar to power sharing mode for StackPower (somewhat active/active)? I understand there is no stack involved here but I'm curious if this functionality is possible.
View 1 Replies
View Related
Oct 2, 2012
I am looking to upgrade my home wifi from a Linksys WRT54G running DD-WRT to something that will handle .11n. I've been looking at the Unifi PoE APs. Their base model support N, but only on 2.4GHz, and only has a 100Mb port. I was concerned about that being a limiting factor. They've recently released a new line that supports Dual Band and has a Gig port, but it cost about 4 times as much. Here are my goals:
1.) PoE if possible. Currently the AP is my rack in the basement. I'l thinking of running an additional cable to somewhere central on the first floor and putting the AP there for better coverage/signal. Running just a CAT 5e cable is much easier than having to supply power as well. Second thought was to get two Unifi APs and setup a mesh with roaming, which it looks like they support, for best coverage. In that case I'd put one in a top floor room that already has CAT 5e.
2.) I'd really prefer access points to a router. I already have a pfsense box that does the routing. If this means getting something that will run DD-WRT, Tomato, or the like and turning it into an AP fine.
3.) I would like something that is dual band .11n.
4.) Something that support RADIUS
5.) Multiple SSID support and VLAN support. I want to be able to offer at least 2 separate networks.
So am I stuck buying the Unifi dual band AP? Or should I get something like the Asus RT-N66U and put Tomato on it?Does anyone have acutal expreience with the Unifi products?
View 19 Replies
View Related
May 27, 2012
Facing issue with 2960G switch , where its do not display "logging trap informational " in show running and show startup .where its showing all other levels from 0 to 5 and 7 after configuration and save commands. [code] after config getting saved , it do not shows in show runn or in show startup while for all other levels it do show the config lines .I tried the same on 12.55.SE release also but its same results . Is this a limitaion of this platform, is there any doc explaining the same for reference. [code]
View 1 Replies
View Related
Apr 14, 2013
We have two switches of the same model (WS-C3560-48PS-S) that are not providing PoE. I'm trying to remotely determine what the cause of the issue is.
Here is some output.
Hostname#show power inlineAvailable:0.0(w) Used:0.0(w) Remaining:0.0(w)
Interface Admin Oper Power Device Class Max (Watts)--------- ------ ---------- ------- ------------------- ----- ----Fa0/1 auto off 0.0 n/a n/a 15.4Fa0/2 auto off 0.0 n/a n/a 15.4Fa0/3 auto off 0.0 n/a n/a 15.4Fa0/4 auto off 0.0 n/a n/a 15.4Fa0/5 auto off 0.0 n/a n/a 15.4Fa0/6 auto off 0.0 n/a n/a 15.4Fa0/7 auto off 0.0 n/a n/a 15.4Fa0/8 auto off 0.0 n/a n/a 15.4Fa0/9 auto off 0.0 n/a n/a 15.4Fa0/10 auto off 0.0 n/a n/a 15.4(code)
View 1 Replies
View Related
Nov 20, 2011
The power supply on 6509 NEB A is not working with me . I have installed only one power supply on the box WS-CAC-3000W
It is showing me that "Input OK , Output fail " from the LCD
I tried with another WS-CAC-3000W , another power source but still same problem .
View 2 Replies
View Related
Mar 12, 2013
I would like to ask if how can we determine by mear physical inspection if the power supply of a CISCO2911/K9 router is AC, POE or DC? Do we have images of the actual spare power supply?
View 3 Replies
View Related
Jan 25, 2012
Just received our new 6513E chassis and I am setting it up in the lab for testing. For prod we would like to run..
1 maybe 2 6704 10 gig cards
3 - 5 6748 cards
1 6724 SFP card
Sup720 setup, possibly upgrading to Sup32's in a few years, Right now for power supplies, I am using 2 WS-CAC-2500W ,But I have to run the supplies in combined mode to get all of the cards online.What power supply should I be looking to purchase for this chassis ?
View 2 Replies
View Related
Nov 21, 2011
I have a 6509 box with the following modules:
View 4 Replies
View Related
Dec 12, 2012
While configuring PoE Ethernet EHWIC PoE modules with ISR G2 routers Cisco DCT gives a warning to select AC Power Supply with PoE ‘PWR-3900-POE’. Do we need to select the PoE power supply for Enhanced EtherSwitch SM PoE modules also (at present it does nt show any warnings)?
View 1 Replies
View Related
Apr 3, 2012
Currently I am using 1000W power supply in Cisco 4500 and I want to upgrade to 2800W power supply.My question is
1) Whether I have to change the power cord while upgrading power supply
2)Whether power cord comes along with the Power Supply while ordering from Cisco
View 1 Replies
View Related
Sep 3, 2012
I was wondering if there was a way to disable the RPS in a 3825? When I do a Sho Env All I get the following;
Redundant Power System is present.
RPS is in standby state
Redundant Power System is present.
RPS is in standby state
How ever there is no RPS in the system. At least not that I know of. There is only one power supply.
View 4 Replies
View Related
Dec 14, 2012
clarify whether this statement found after table 4 of the Cisco 819 4G router data sheet truly means that there will be a power supply to support 48VDC in Q1 of 2013? Here is the statement:
"* Future external reference for 24V, 52V, and 72V DC for railway applications Q1CY2013"
Here is the data sheet source:
[URL]
I would want to power this router from a -48VDC plant, which is common at remote telecom sites.
View 1 Replies
View Related
May 22, 2013
while the 3560 switch is running? Is it hot-pluggable?
WS-C3560X-48P is the switch and I would be adding a C3KX-PWR-1100WAC
View 1 Replies
View Related
Jul 11, 2012
Looking at the specs for the 3750 power supply - is the WS-C3750X-48P-S model with the 715W power supply referring to the amount for both power supplies per switch or just one power supply per switch? Meaning, is the 715 a accumulative number or, just the watts of one power supply. I would like to purchase a 3750x PoE switch with redundant power supplies. If this model is not the correct one?give me the model that offers 48 port PoE with redundant power supplies?
View 6 Replies
View Related
Dec 3, 2011
power supply problem...?Switch cisco WS-C3750-24P is showing "Unavail" from sh env all.Switch3750#sh env all FAN is OK,TEMPERATURE is OK,SW PID,Serial# Status Sys Pwr PoE Pwr Watts,Does it means that power supply 1 was removed? failed?,Do you know about another command to see more details?
View 3 Replies
View Related
Dec 8, 2012
I would like to check if it may be possible to hot-upgrade/swap the 4506E power supplies? Based on the configuration guide; I have summarized the steps as follows:
1. Switch has 2 existing power supplies to be upgraded
2. Remove right side/bay 2 power supply and install new power supply
3. At this point; the new power supply will be in err-disabled due to different power supplies on the switch
4. Remove the left side power supply and install new power supply
For item 4; during the removal of the old power supply in bay 1/left side and installation of the new power supply; I am wondering if the switch would lose power even though the new power supply is installed in bay 2?
View 1 Replies
View Related
Dec 23, 2012
I was wondering if I am able to add a redundant power supply to an asr 1001 router that is in production without losing connectivity or causing any diruption to the Users - is it hotswappable?
View 1 Replies
View Related
May 9, 2013
can I plug power supply from 4500 to 6500? more specifically we have power supply PWR-C45-1300ACV. And we need to place some power supply to 6500, which has only one active module. So 1300 should be enough for it. But we dont know if they are physically compatible, if it is possible to plug. I didnt find this power supply to be officially?
View 4 Replies
View Related
Apr 6, 2012
Having a strange issue here with an 7606-s chassis equipped with two sup720's, and two regular line cards. There is only one power supply, PWR-2700-AC. I recently builded this setup and powered it on last week for the first time. It ran fine for about 20 minutes while suddenly the chassis powered down.
I've checked the back of the chassis and noticed that the power supply had it's 'input ok' and 'power fail' led lit. I toggled the power switch and waited half an hour to power it on again. This time only 1 minute of joy. My first idea was the PSU due to the power fail led so I had it swapped by the supplier for another. Unfortunately, when I powered it on today, it didn't change a thing, still unexpected power downs.
So I've checked the following documentation: [URL] and followed the suggestion to power the chassis on without any modules in the slots. So I did that and it ran for 8 minutes only. However, the fan tray did respond properly when I removed the small thermal module in the upper right by increasing the fans to full speed.
Following above documentation, it points to the chassis (there is not much left). Now the real question comes, isn't there anything else that could be the cause of this?
View 1 Replies
View Related
Mar 17, 2013
We are getting below errors on our Cisco 4500 Switche PS after Power Down activity.
Switch1
------------------ show power detail ------------------
Power Fan Inline
Supply Model No Type Status Sensor Status
------ ---------------- --------- ----------- ------- -------
PS1 PWR-C45-4200ACV AC 4200W good good good
PS1-1 off
PS1-2 220V good
PS2 PWR-C45-4200ACV AC 4200W err-disable good good
PS2-1 220V good
PS2-2 220V good
*** Power Supplies of different type have been detected***
00:01:02: %C4K_CHASSIS-3-MIXINPOWERDETECTED: Power supplies in the chassis are of different types (AC/DC) or wattage(code)
View 1 Replies
View Related
Nov 6, 2012
I have a 3750x 48port POE switch that I installed a second power supply in. But it doesnt power on. Am I supposed to enable it in the switch somewhere? I've plugged it into a couple different outlets so I know that's not the problem.
View 4 Replies
View Related
Jul 21, 2012
When quoting a Catalyst 3750X with PoE (WS-C3750X-48P-E) the Dynamic Configurator Tool allows to include as the secondary power supply option the Catalyst 3K-X 350W AC Secondary Power Supply (C3KX-PWR-350WAC/2), but the default included primary power supply is the Catalyst 3K-X 715W AC Power Supply (C3KX-PWR-715WAC). My questions are the following:
1. Will this combination of power supply work?
2. Will the C3KX-PWR-350WAC/2 be able to power up the switch if the primary power supply of 715W fails?
3. Will the PoE will be lost if the primary power supply fails and only the secondary power supply of 350W keeps working?
4. If this secondary power supply of 350W is not suitable for PoE, why it is available as a secondary power supply option in the Dynamic Configurator Tool for a PoE switch?
View 4 Replies
View Related
Mar 6, 2013
I understand that 8700W enhanced AC power supply is Compatible with 6-, 9-, and 13- slot chassis
Based on 8700W Enhanced PS datasheet, it can be installed into existing Cisco Catalyst 6500 Series Switch chassis: both E- and non-E series Cisco Catalyst 6500 Series Switch chassis.
Can we use 8700W enhanced AC power supply with 6513 externally / internally (within one of the chassis slots like 6513-E ?
View 1 Replies
View Related
Dec 3, 2011
I need a L2 switch with dual AC power supply and RJ45 uplink The optin I got was WS-C3560X-48T-L + C3KX-PWR-350WAC , but the problem is with uplink . There is no RJ45 1G uplink , there is only option for SFP uplink The another option was WS-C2960G-48TC-L , but there is no dual AC power supply option a good model ( Dual AC power supply , RJ 45 uplink ports (Gig) , with 48 port 100/1000 UTP)
View 3 Replies
View Related
Aug 29, 2012
is there a command available to run diagnostics in ASR port/SPA? the one below is from a juniper remote device. i was only able to find 'test interface' but haven't run this yet (currently in production).
View 5 Replies
View Related
Jul 4, 2012
I have an C4900M with twingig converter and SFP GLC-LX-SMD in. So the SFP supports DOM function. It is running on 12.2(53)SG2.
I would to the see the optical power level of the SFP, but it does not recognize 'show interface transceiver' command as showed in 4500 software guide.
View 5 Replies
View Related
Aug 4, 2011
I'm new on this version and I don't know how to create a Monitor/Alarm to detect that a power supply has gone down. I want to send a message.
View 1 Replies
View Related
Mar 13, 2013
I have configured a vlan interface on a 3750 switch. there is aprox 4Mb active traffic flowing through the interface, but when I do a "show interface vlan (vlanid)" the output show zero bits in and zero bits out. Its a typical L3 config with one IP on the vllan interface acting as the gateway for the VLAN devices. Is this a normal behaviur ? and if so is there any way to get the traffic in/out stats. The end PC/devices are connected to this switch via an L2 TRUNK and I dont have access to the L2 switch on which the actual devices connect. so cant get the real time stats of those interfaces.
View 2 Replies
View Related
Jul 1, 2012
I need 3925 router and i want to install SM-ES3G-16-P etherswitch module with PoE into it. So my question is do I need PoE power supply or not? Will PoE ports on this module work with basic AC power supply?
View 2 Replies
View Related
Oct 8, 2012
We are trying to monitor two stacks of CISCO WS-c3750X running IOS 12.2.(58)SE.
We can get the state of the power supplies, but after a power cycle or reboot of the switches the identifier of ONE of the Power supplies ALWAYS change. The OIDs for the rest of the PS do not vary. The problem happens in the two stacks.
View 6 Replies
View Related