Cisco Switching/Routing :: How To Show C4900M SFP Optical Power Level

Jul 4, 2012

I have an C4900M with twingig converter and SFP GLC-LX-SMD in. So the SFP supports DOM function. It is running on 12.2(53)SG2.
 
I would to the see the optical power level of the SFP, but it does not recognize 'show interface transceiver' command as showed in 4500 software guide.

View 5 Replies


ADVERTISEMENT

Cisco WAN :: Verify Optical Power Level In SFP Inserted In 3800?

Sep 14, 2012

I have a Cisco3800 with IOS Version 12.3(14)T2 and I have an HWIC-1GE-SFP module inserted on it.    
 
I need to know if there is a command to verify optical power level in this module inserted in the Cisco 3800 router?
 
Something similar to the following command that I can execute in an Cisco ASR9K:
 
show controllers Te0/0/0/1 phy | i Rx

View 4 Replies View Related

Cisco Switching/Routing :: WS-C3560-48PS-S Show Power Inline But No Power Available

Apr 14, 2013

We have two switches of the same model (WS-C3560-48PS-S) that are not providing PoE. I'm trying to remotely determine what the cause of the issue is.
 
Here is some output.
 
Hostname#show power inlineAvailable:0.0(w)  Used:0.0(w)  Remaining:0.0(w)
Interface Admin  Oper       Power   Device              Class Max                            (Watts)--------- ------ ---------- ------- ------------------- ----- ----Fa0/1     auto   off        0.0     n/a                 n/a   15.4Fa0/2     auto   off        0.0     n/a                 n/a   15.4Fa0/3     auto   off        0.0     n/a                 n/a   15.4Fa0/4     auto   off        0.0     n/a                 n/a   15.4Fa0/5     auto   off        0.0     n/a                 n/a   15.4Fa0/6     auto   off        0.0     n/a                 n/a   15.4Fa0/7     auto   off        0.0     n/a                 n/a   15.4Fa0/8     auto   off        0.0     n/a                 n/a   15.4Fa0/9     auto   off        0.0     n/a                 n/a   15.4Fa0/10    auto   off        0.0     n/a                 n/a   15.4(code)

View 1 Replies View Related

Cisco Switching/Routing :: Default IOS Image Of WS-C4900M

Jan 11, 2012

I'm not able to find in all the datasheets what's the default (out-of-the-box) IOS image of a WS-C4900M.When I buy a WS-C4900M I know that there is an IP-BASE IOS but which version?
 
On the datasheet there is a 12.2SG but is an IPBASE with SSH? W/O SSH? UPGRADE SSH? I'm trying to make a comparison between this image and a cat4500e-entservices-mz.150-2.SG2.bin (Advanced Enterprise Services) on the feature navigator to make sure the our customer need this last IOS Upgrade.

View 7 Replies View Related

Cisco Switching/Routing :: 2960S - Internal Power Supply Show Unavailing When Running Off RPS?

Feb 13, 2012

I have a 2960S connected to an RSP 2300.  The 2960S is currently running off of the RPS, and I would like to switch it back to the internal power supply.  Can I just run "power supply 1 on"?  Will this cause the switch to reboot?  Also I am concerned because when I do a show env power it shows: [code]
 
 Is it normal for the internal power supply to show Unavail when running off RPS?

View 1 Replies View Related

Cisco Switching/Routing :: Optical Transceiver For 5509 Switch?

Dec 18, 2011

I am looking for optical transceivers that are compatible with the Cisco 5509 switch. Preferably 1G.

View 3 Replies View Related

Cisco Switching/Routing :: 3750 - Show Interface Vlan (ID) Doesn't Show In / Out Traffic Rate

Mar 13, 2013

I have configured a vlan interface on a 3750 switch. there is aprox 4Mb active traffic flowing through the interface, but when I do a "show interface vlan (vlanid)" the output show zero bits in and zero bits out. Its a typical L3 config with one IP on the vllan interface acting as the gateway for the VLAN devices. Is this a normal behaviur ? and if so is there any way to get the traffic in/out stats. The end PC/devices are connected to this switch via an L2 TRUNK and I dont have access to the L2 switch on which the actual devices connect. so cant get the real time stats of those interfaces.

View 2 Replies View Related

Cisco Switching/Routing :: 3750 Switches With All Optical Fiber Ports?

Feb 14, 2013

We have a scenario where we want to connect 14 access layer  2950 switches to Core switch 3750 via optical fiber in a LAN.What model of 3750 Switch should we use to tackle this situation.I have learnt that WS-C3750X-24P should support it.Isnt it?
 
Can we use optical fiber SFP module to connect 2950 switches to core switch?Does Cisco 2950 Switch support optical fiber sfp module?

View 2 Replies View Related

Cisco Switching/Routing :: 2960 Don't Display Logging Trap Informational In Show Running / Show Startup

May 27, 2012

Facing issue with 2960G switch , where its do not display "logging trap informational " in show running and show startup .where its showing all other levels from 0 to 5 and 7 after configuration and save commands. [code] after config getting saved , it do not shows in show runn or in show startup while for all other levels it do show the config lines .I tried the same on 12.55.SE release also but its same results . Is this a limitaion of this platform, is there any doc explaining the same for reference. [code]

View 1 Replies View Related

Cisco Wireless :: AP Power Level Assignment 1252

Sep 1, 2011

We are using WiSM WLCs and WCS to control a variety of 1131,1142 and 1252 APs utilising AP groups.
 
I've noticed on WCS that the power of certain APs is at a low setting, even though the APs surrounding them are also at a low setting. This is causing some gaps to appear on the heatmaps. I was under the impression that the WLCs would regulate the AP power to compensate for any gaps. Currently the global TX power level assignment method algorithm is set to automatic every 600 sec.
 
Now, obviously I could change this to fixed (not ideal as I may not want all my APs to run at max power all the time) or to on demand (also not ideal due to the increased admin).
 
Is there a way I can verify that the automatic power levels are adjusting as they should? Why are there gaps appearing in my heatmaps?
 
*NB It's not just the gaps on the heatmaps, I'm getting reports of dropping wireless signals from users hence me looking at the heatmaps and they just happen to correspond.
 
WLC version 6.0.199.4
WCS version  7.0.172.0

View 4 Replies View Related

Cisco Wireless :: Adjusting Maximum Power Level Assignment Value With AIR-CAP35021

May 1, 2012

I have a deployment of AIR-CAP35021 APs. They are in 2 buildings with multiple floors. They are installed in a row down the hallways. I want to increase the power levels by using the controller and not configuring the APs individually. I have set the TPC value to -50 but I still do not reach the outer walls of the floors in some areas. I need to know what to set the Max Power Level Assignment or Min Power Level Assignment to to get the APs to power up some more. If the MAX value is 30 and the default is 30 then how to adjust that value?

View 5 Replies View Related

Cisco Wireless :: 4402 - Setting Update Time For Auto Tx Power Level Assignment

Dec 1, 2011

We have a WLC 4402 controlling 40+ LWAPs.  Is there a way to keep Tx power level assignment dynamic, but set the time of day it does it?  I'd like to minimize user impact.  (Firmware v. is 7.0.116.0)

View 2 Replies View Related

Cisco Switching/Routing :: 3750 - Power Stack Has Unbalanced Power Supplies

Jun 9, 2013

I am receiving the following error on 3750 stack switches. have already verified the power status and found ok.
 
IOS used: Cisco IOS Software, C3750E Software (C3750E-UNIVERSALK9-M), Version 12.2(55)SE3, RELEASE SOFTWARE (fc1)

211540: Jun 10 10:45:17.935 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS: Switch 4's power stack has unbalanced power supplies
211541: Jun 10 10:46:18.045 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS:

[Code]....

View 1 Replies View Related

Cisco Switching/Routing :: Stack-power 3750x / FRU Power Supply Is Not Responding

Sep 4, 2012

After stacking two 3750X switches, with four equal power-supply's, with StackWise and PowerStack , still got the next message every few hours %PLATFORM_ENV-1-FRU_PS_ACCESS: FRU Power Supply is not responding (gn4m-rt1p08-04-2)( note that the message revers to the second switch in the stack ) although the stackwise and powerstack on the switches is oke and are working correctly. !
 
Config  : Stack-power in power-sharing mode/strict With CLI on the switch : All the power supply's and stack-power details, prio look OK.
 
Only: LMS prime /inventory/cisco-view/configure/power supply status  result :  some power supply's are marked as disabled.with the command  > power supply 2 slot a off/on I manage to get the status back to "normal", but after a few hours some power supply's are again marked as "disabled".
 
Looks like SNMP en IOS difference from opinion.
 
Hardware
WS-C3750X-24S-S
C3KX-PWR-350WAC
 
Software
15.0(2)SE
C3750E-UNIVERSALK9-M

View 5 Replies View Related

Cisco Switching/Routing :: 6500 - Power-Redundancy Mode Combined And Power Fail

Feb 28, 2011

I have a 6500 chassis with 2 power supplies. At the moment  I am using the default configuration:
 
power-redudancy mode redundant
 
The problem is that an inserted module is in "power deny" state due too insufficient power.
 
I know, that It's not a good idea to change into combined mode (loss of redundancy), but my customers requested this anyway.
 
So I will change to combined mode. So here's the 1 million dollar question: "Which modules will go into power deny, if one of my power supplies fails?"
 
The 6500 config guide states:
 
"Power supply is removed withredundancy disabled
• System log and syslog messages are generated.
• System power is decreased to the power capability of one supply.
• If there is not enough power for all previously powered-up modules, some modulesare powered down and marked as power-deny in the show power oper state field."
 
Well, do you know if there's any way to configure some kind of priority? E.g. I definetly don't want by 10Gig Module or WiSM module to be in power deny. Can i statically make sure, those module will be powered on for sure? Like: "power enable module slot_number" How is this calculated? Or is random?

View 3 Replies View Related

Cisco Switching/Routing :: 3750X Stand Alone Secondary Power Supply Act As Pool Of Power

Apr 4, 2012

In a stand alone 3750x switch configuration, can the secondary power supply only act as a redundant power supply (active/standby), or can it become a "pool" of power similar to power sharing mode for StackPower (somewhat active/active)?  I understand there is no stack involved here but I'm curious if this functionality is possible.

View 1 Replies View Related

Cisco Switching/Routing :: Cat 6509E 6Kw PS AC Input Level Verification

Oct 27, 2011

I have a 6509E switch with dual 6Kw power supply that is logging "Power supply 1 input has changed.  Power capacity adjusted to 2671.20W" then will bounce back to normal at random times from 1sec to 10sec. Is there a command to check what each input level of the power supply to try to identify possibly which source is causing the problem? The power supply input lights remains green while this is occuring.

View 3 Replies View Related

Cisco Switching/Routing :: 3750x / IOS Upgrade And License Level?

Oct 7, 2012

I have two 3750x in a stack  running c3750e-universalk9-mz.122-55.SE3.bin with License Level: ipservices?I am planning to upgrade to c3750e-universalk9-mz.122-58.SE2.bin will this keep my ipservices licence or revert back to IPbase

View 3 Replies View Related

Cisco Switching/Routing :: IOS Level Support Required For WS-X6748-GE-TX?

Nov 21, 2012

currenly running a C6509E, with a WS-SUP720-3B running IOS level S72033-adventerprisek9_wan-MZ.122-22.SXH3.  I want to install a WS-X6748-GE-TX blade and would like NOT to have to upgrade IOS at this time.  Future migrations are planned.  Can this be done? 

View 6 Replies View Related

Cisco Switching/Routing :: C3950 - Intermittent Message / May Suspend At Level 4

Jul 16, 2012

For a week now, one of my Cisco 3945 routers displays, from time to time, the following message in its log:
 
2012-07-16T14:12:43.852017+00:00 cb00-r103 220: [syslog@9 s_sn="59"]: Jul 16 16:12:42 MEST: %SYS-2-INTSCHED: 'may_suspend' at level 4  -Process= "OSPF-100 Hello", ipl= 4, pid= 320
2012-07-16T14:12:43.852017+00:00 cb00-r103 221: [syslog@9 s_sn="60"]: -Traceback= 15CB073z 9081B7z 2851571z 11B7582z 11C275Ez 11C2906z 11C03E3z 1B907B5z 1B9064Cz 1BA5737z 172047Fz 47FFDCz 4D2EEDFz 4D2ED71z 4D2EA2Bz 4D30097z
2012-07-16T15:06:11.686817+00:00 cb00-r103 222: [syslog@9 s_sn="61"]: Jul 16 17:06:10 MEST: %SYS-2-INTSCHED: 'may_suspend' at level 4  -Process= "OSPF-100 Hello", ipl= 4, pid= 320
2012-07-16T15:06:11.686817+00:00 cb00-r103 223: [syslog@9 s_sn="62"]: -Traceback= 15CB073z 9081B7z 2851571z 11B7582z 11C275Ez 11C2906z 11C03E3z 1B907B5z 1B9064Cz 1BA5737z 172047Fz 47FFDCz 4D2EEDFz 4D2ED71z 4D2EA2Bz 4D30097z

[code]....
 
It never happened before and the configuration did not change. The only thing that happened, the WAN connection (point-to-point to a Cisco 3845) went down and the router rebooted while the WAN was down. When the WAN came up again, everything went fine, until about an hour later and the first occurrence of this mentioned log.This 3945 does establish an IPSec tunnel with its peer (the 3845) and all the traffic, including OSPF, is going through the tunnel. 

View 4 Replies View Related

Cisco Switching/Routing :: 881w - ISR Invalid Memory Action At Interrupt Level

Feb 7, 2013

My company has an 881-w ISR that provides wireless and wired network functions for our small office (about 20 users).  I was attempting to create a new V LAN (another story), and was able to create the V LAN (4) and assign it a new IP.  However, when i came in today, and when i attempted to connect to the ISR, the serial console started spewing this over and over:
 
*Feb  8 13:31:32.479: %SYS-2-MALLOCFAIL: Memory allocation of 8 bytes failed from 0x81528DF0, alignment 0
Pool: Processor  Free: 131305952  Cause: Interrupt level allocation
Alternate Pool: I/O  Free: 17850656   Invalid memory action (malloc) at interrupt level -Traceback= 0x820168A0z 0x82E4
-Process= "<interrupt level>", ipl= 4 -Traceback= 0x81FF6FC8z 0x820168D0z 0x82E49944z 0x81528DF4z 0x800C3AF8z 0x800C4760z 0x810A1208z 0x810A6F8Cz 0x810BA9E0z 0x810BACBCz 0x80241A24z 0x8025ADE8z 0x8025E2F8z 0x8030ACD4z 0x804E1518z 0x80310368z

[code]....
 
Now, I did leave the console session up overnight, as that's the only thing that I can think of.  As expected, our service contract had expired.  I did reboot the ISR, and I am looking to see if this can be fixed, or symptomatic of a larger issue, and time to replace?  At this point i can't even get it to stop, and thus cannot log in.

View 1 Replies View Related

Cisco Switching/Routing :: IE2000 Industrial Ethernet Device Level Ring Support

May 3, 2012

Have a potential customer that is looking at the IE2000 series switch and at the Rockwell Allen Bradley switch
 
Question is does it support Device Level Ring (DLR) capability.  I do not see this specifically mentioned in the Data Sheets but it talks about a
Resilient Ethernet Protocol (REP) and I am wondering if this is the same thing?

View 1 Replies View Related

Cisco :: 3550 - Show Power Usage For Devices

Jan 27, 2013

Is there anyway I can see the power usage on either a 3550 switch and/or 7301 router? I have some far away I wish to see the usage off.
 
Devices with module power supplies like cat 4500s/6500s/7600 etc all have commands like "show power ...", which will show me input voltage, current and power usage in watts. Is there anything like this for devices without module power supplies?

View 2 Replies View Related

Cisco Switching/Routing :: 877 / Show DSL Interface ATM?

Aug 30, 2010

i've got a Cisco 877 router connected to an ADSL link. i'm using the show dsl interface atm just to have a look on its performance. i've tried to search on Cisco website on how to interpret the output but a blog gave me more info [URL]. My question now is, what readings do i consider? is it on the left (ATU-R) or on the right (ATU-C)?
 
877ROUTER#sh dsl int atm0                ATU-R (DS)                      ATU-C (US)Modem Status:    Showtime (DMTDSL_SHOWTIME)DSL Mode:        ITU G.992.1 (G.DMT)ITU STD NUM:     0x01                            0x01Vendor ID:       'ALCB'                          'ALCB'Vendor Specific: 0x0000                          0x0000Vendor Country:  0x00                            0x0FCapacity Used:   31%                             85%Noise Margin:    34.0 dB                         10.0 dBOutput Power:    16.0 dBm                        12.0 dBmAttenuation:     10.0 dB                          6.0 dBDefect Status:   None                            None                        Last Fail Code:  NoneSelftest Result: 0x00Subfunction:     0x15Interrupts:      1453 (2

[code]....

View 3 Replies View Related

Cisco Switching/Routing :: Show Version On VSS 6509?

Apr 7, 2013

Is there a way I can check the version of each device on two Cisco 6509 if they are Virtually connected (VSS)? When I enter the command show version, it only shows one result, unlike show module, you have an option to choose which switch by entering 1 or 2.

View 3 Replies View Related

Cisco Switching/Routing :: 805 Show IP Interface Brief Protocol Down

Feb 24, 2013

I have encounterd a broplem on my Cisco 805 model.
 
When i use the command "show ip interface brief" the status shows "up" but the protocol is "down" on my serial interface.
 
The link between my to sites is down after this happend.

View 1 Replies View Related

Cisco Switching/Routing :: Sh Inv Does Not Show All PSUs - Cat 3750X IOS 12.2(58)SE2

Sep 3, 2012

I did a sh inv on my newly built 2x Cat 3750X + Cat 3750-24FS stack running 12.2(58)SE2). It only showed 3 of the 4 Cat 3750X PSUs - Sw1 PSU 0, Sw2 PSU 0 and Sw2 PSU 1.
 
Switch#sh invNAME: "1", DESCR: "WS-C3750X-24"PID: WS-C3750X-24T-S   , VID: V02  , SN: FDO*******D
 
NAME: "Switch 1 - Power Supply 0", DESCR: "FRU Power Supply"PID: C3KX-PWR-350WAC   , VID: V01D , SN: DTN1533L00N
 
NAME: "2", DESCR: "WS-C3750X-24"PID: WS-C3750X-24T-S   , VID: V02  , SN: FDO*******6
 
NAME: "Switch 2 - Power Supply 0", DESCR: "FRU Power Supply"PID: C3KX-PWR-350WAC   , VID: V01D , SN: DTN1533L08M(code)

View 8 Replies View Related

Cisco Switching/Routing :: C3640 / Show Ip Protocols Not Showing Anything

Apr 14, 2012

For an assignment in a class I am taking I created a simple network using GNS3 and set up static routing. Everything works fine, I can ping all of the hosts. One of the questions I am supposed to fill out is what happens when I use the "show ip route" and "show ip protocols" commands. When I use "show ip route" I get what seems to be the correct output. However when I use the "show ip protocols" command nothing happens. No output, no error, no nothing. It just goes right back to the prompt. This happens exactly the same on both routers in my network. incase it matters the router is c3640.
 
PS. would the output be non-existent because I have not set up any ip protocols. In a similar assignment I set up rip and when I used "show ip protocols" i did get what appeared to be the correct output. However I didn't write it down and when I put in the command again about an hour later after I took a break I also did not get an output until I re-entered the rip related commands.

View 2 Replies View Related

Cisco Switching/Routing :: 3845 Show Version Interpretation

Mar 25, 2012

I change only a chasis in a router 3845, but the "show version" command should be the same , except for the serial number and other parameter of time..  however, the number of serial interface change from 4 up to 2.The hardware module of 3845 are 3.

1.- VWIC E1/T1 with 2 port
2.- Fastethernet 36 port
3.- Supervisor engine with 2 Gigabit port

View 7 Replies View Related

Cisco Switching/Routing :: 3750 Show Interface Options

Jan 16, 2012

I'm troubleshooting a 3750 switch stack problem where computers are showing input and CRC errors.  I'd like to be able to execute a "show interface" command that will show me only the line showing the switch port and the line showing the input errors, but so far I can't figure out a way of combining those two parameters. 
 
If I do "show interface | include Ethernet[0-9]�" I get all the lines showing the port numbers:
 
GigabitEthernet1/0/1 is up, line protocol is up (connected)
GigabitEthernet1/0/2 is up, line protocol is up (connected)
GigabitEthernet1/0/3 is up, line protocol is up (connected)

[Code].....

View 9 Replies View Related

Cisco Switching/Routing :: 6509 FWSM VLANs Do Not Show Up

Feb 7, 2012

Configuring FWSM in a 6509.  When I set "firewall vlan-group 40  40-42,251", it results in: "No more than one svi is allowed. Command rejected.". 
 
I had "firewall multiple-vlan-interfaces" set for a previous use of this module, but took that off with the "no" command.  Suspect that is the issue, but do not see how to resolve.  Seems similar to bug CSCsr48563, but I am at the fixed code for that bug.

View 1 Replies View Related

Cisco Switching/Routing :: SG300 CLI Show ARP Returns Bad Parameter Value

May 7, 2013

I'm trying to examine the ARP table on specific phy ports on a SG300 switch.  The Cisco CLI guide shows this syntax:
 
show arp [ip-address ip-address] [mac-address mac-address] [interface-id]
 
Using the CLI and the "?" key to get assistance, I'm not successful:
 
switch3#show arp                  
  configuration        Display ARP related configuration
  ip-address           Filter ARP show by IP
  mac-address          Filter ARP show by MAC
 [Code]...
 
I don't have http server enabled, I prefer SSH and CLI to do my work.

View 3 Replies View Related

Cisco Switching/Routing :: Power Connect 6224 With Routing Enabled With Several VLAN Setup

Jan 19, 2013

I have a power conncet 6224 with routing enabled with several VLANs setup.VLAN Database: 6,8,10,90-254VLAN 6 is our management vlan10 is for our core network services (DNS, Domain, Exchange etc)90-254 are isolated vlans.What I need to accomplish is to prevent vlans 90-254 from communicating with each other and only allow communication to VLAN 10 and the internet. All internet firewall work will be handled by our Sonicwall. [code]

View 1 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved