Cisco Switching/Routing :: Nexus 5010 Rebooted Itself?
Feb 9, 2013
Our Data Center Switch (5010) rebooted itself today, underneath the captured screen
NX5010-1(config-vlan)#
Broadcast message from root (console) (Sun Feb 10 14:22:41 2013):
The system is going down for reboot NOW!
NX5010-1# sh system reset-reason
----- reset reason for Supervisor-module 1 (from Supervisor in slot 1) ---
1) At 740938 usecs after Sun Feb 10 14:22:41 2013
Reason: Reset triggered due to HA policy of Reset
Service: nohms hap reset
Version: 5.0(2)N1(1)
[code]....
View 2 Replies
ADVERTISEMENT
Aug 12, 2012
I currenty have a Nexus 5010 connected to a core 3750X switch stack in a VPC trunk using 2 1Gbps links. I want to move this link to 2 10Gbps links without losing connectivity. So I want remove a 1G link and move it to 10G and then once that's up move the other 1G link to 10G hopefully without losing connectivity. So the question is, can I have a 1G and 10G link between the Nexus and 3750s in the same virtual port channel without causing problems?
View 3 Replies
View Related
Nov 23, 2012
we have a old Nexus 5010 running version 5.0(3)N1(1)it is in a franckenblock(like frankenstein) ie . we bought the parts and create our own system design before VCE was created. He have since bought VCE V block for our production sites. we use the franc ken block to test before we migrate to the production v block 300 FIX the issue we have is the 5010 will only see two 1 Gb/s SFP fiber modules in the first 12 slots. All these slots are dual 1g/10G. If we add more than two, it claims not to see them. We tried swapping the sfp and using both sfg-GE-MM and GLC-SX-MM moduels, no difference at all 1g sfp are in the first 5 slots. only the first two slots are up.the others say "Link not connected" or "SFP not inserted"all five links are the same SFP and are plugged in other switches.the green link lights are on plugged in SFP, even when the CLI states they are not plugged uni tried both two types of 1 Gb/s SFP. sfg-GE-MM and GLC-SX-MM ,i move the sfp between slot 1,2 and 3,4,5. nothing changed,From "sh int brief" you can see that it can see the sfp ie they are all 1Gfrom "sh int status " it sees 1g but why does it say type 10G?why when i go to the "int e 1/5" and try switch port mode now, it can't mode and trunk at now there (;also how to i stop or clear EU51 %SYSMGR-2-TMP_DIR_FULL: System temporary directory usage is unexpectedly high at 87%.i put as much info in the attached file as i could.
View 1 Replies
View Related
Dec 11, 2011
We are looking for some latency in our net and I am trying to check if our STP implementations is running correctly - we have a simple flat network here and no blocked ports here - just two nx 5010 which are interconnected with two uplinks.A remote site - mirrored setup - with 2 10G dark fiber connections - one for each nx5010 - is connection a DR site. I have split the two sites in two stp domains by enabling bpdu-filter on the vpc between the two sites.
I have been running wireshark on the local segment for some time and see the STP RST ROOT announcement every 2. seconds - this is probably normal ? I was looking for some alternate root negotiation packets which would cause the mac tables to be flushed.
View 2 Replies
View Related
Jan 10, 2012
Can nexus 5010 supports inter v lan routing , as there is no core switch and router available in current network.
View 2 Replies
View Related
Jun 23, 2012
I am not able to create more than 256 VLAN in Cisco Nexus 5010 switch. While creating I am getting "No VLAN resources available for VLAN creation" Details below -
Switch model - 5010
Software : NX OS 4.0 (1a)
Error Message:
Nexus_5010(config)# vlan 417
ERROR: No VLAN resource available for VLAN creation.
View 5 Replies
View Related
Aug 7, 2012
I'm trying to create a vpc between a Nexus 5010 and Nexus 5020 switch. I recently upgraded the software so they are running the same version. I connect get a vpc link. Is there something wrong with my setup? Is a vpc between a 5010 and 5020 even possible? They are connected using a pair of Intel X520's in 802.3AD teaming mode. [code]
View 2 Replies
View Related
Jul 20, 2010
My monitoring tool is reporting alerts for high cpu utilization on Nexus 5010.Image is 4.1(3)N1(1) Only command supported on this code is sh proc cpu.The output of which does not really tell what is the current cpu utilization.How do i troubleshoot the cause of high cpu on nexus switches.
View 12 Replies
View Related
Dec 6, 2011
I am trying to configure get the QLogic 8240 card to work properly in ESXi 5.0. I want to be able to send the iSCSI traffic down the iSCSI portion of the card and use the ethernet portion of the card to do NFS.
Here are my vlans I am working with..
vlan 420 = fcoe
vlan 500 = NFS
vlan 1000 = iSCSI
I have my interface currenly set as the following on the Nexus 5000.
interface Ethernet1/17
[Code]...
View 5 Replies
View Related
Nov 23, 2011
I found intermittent link down(20~40 seconds average) occurred about 1~10 times every month. SAP reported a lot of active connections are disconnected and I used a batch to ping and found "requested time out" about 30 seconds.And Windows, SQL server, Nexus 5010 do not show any errors. We run cluster and cluster does not fail over.And I don't know which cables or nics cause this issue. When it happened, almost all servers are unreachable. For example, SQL server 1 -> SQL server 2, IBM HS22-1 -> SQL server 1. However, some connections are not dropped sometimes. It varies each time.PS: I run this topology last year without any problems but it started intermittent link down from 2011/1/7. Because there is no errors in Nexus 5010, it is difficult to troubleshoot. Cisco TAC recommended us to implement virtual port channel yesterday. Could I use "errdisable detect cause" to detect what caused the intermittent link down? Is there any error logs or switch parameters/status can use to troubleshoot?
View 18 Replies
View Related
May 19, 2013
Basically I am trying to use Wireshark to do a packet capture on a Nexus 5010. I want to do a monitor session on on the switch so I can capture from a source port to a destination port on the same switch. I can configure the source port but when I go to configure the destination port I get "ERROR: Eth102/1/4: Configuration not allowed on fex interface". I have tried to reconfigure this port as a switchport but "switchport mode access" command does not take. I don't want to make any changes to any other ports but this one.
View 1 Replies
View Related
Feb 20, 2012
Here is an example of what each switch logs when a server drops offline. Sample logs taken between 5:32am and 5:35am on Feb 20. This particular one was having problems all weekend. Switch #1 encountered over 2000 interface resets. The corresponding VPC port on Switch #2 only had 13 resets.
NEXUS SWITCH #1
2012 Feb 20 05:32:09 q91-sw01-5010 %ETH_PORT_CHANNEL-5-FOP_CHANGED: port-channel10: first operational port changed
from Ethernet1/10 to none
2012 Feb 20 05:32:09 q91-sw01-5010 %ETH_PORT_CHANNEL-5-PORT_DOWN: port-channel10: Ethernet1/10 is down
2012 Feb 20 05:32:09 q91-sw01-5010 %ETH_PORT_CHANNEL-5-PORT_DOWN: port-channel10: port-channel10 is down
2012 Feb 20 05:32:09 q91-sw01-5010 %ETHPORT-5-IF_DOWN_PORT_CHANNEL_MEMBERS_DOWN: Interface port-channel10 is down (
No operational members)
[code].....
View 1 Replies
View Related
Feb 9, 2011
I'm not sure if I'm missing something basic here however i though that I'd ask the question. I recieved a request from a client who is trying to seperate traffic out of a IBM P780 - one set of VIO servers/clients (Prod) is tagged with vlan x going out LAG 1 and another set of VIO server/clients (Test) is tagged with vlan y and z going out LAG 2. The problem is that the management subnet for these devices is on one subnet.
The infrastructure is the host device is trunked via LACP etherchannel to Nexus 2148TP(5010) which than connects to the distribution layer being a Catalyst 6504 VSS. I have tried many things today, however I feel that the correct solution to get this working is to use an Isolated trunk (as the host device does not have private vlan functionality) even though there is no requirement for hosts to be segregated. I have configured:
1. Private vlan mapping on the SVI;
2. Primary vlan and association, and isolated vlan on Distribution (6504 VSS) and Access Layer (5010/2148)
3. All Vlans are trunked between switches
4. Private vlan isolated trunk and host mappings on the port-channel interface to the host (P780).
I haven't had any luck. What I am seeing is as soon as I configure the Primary vlan on the Nexus 5010 (v5.2) (vlan y | private-vlan primary), this vlan (y) does not forward on any trunk on the Nexus 5010 switch, even without any other private vlan configuration. I believe this may be the cause to most of the issues I am having. Has any one else experienced this behaviour. Also, I haven't had a lot of experience with Private Vlans so I might be missing some fundamentals with this configuration.
View 3 Replies
View Related
Sep 29, 2012
I have a 5010 that simply won't load any system image. Loads the kickstart image just fine, but once at the Switch(boot)# prompt just give me garbage when I enter "load bootflash:n5000-uk9.5.1.3.N2.1b.bin Restarting system.
Loader Version pr-1.3
loader> dirbootflash: lost+found n5000-uk9-kickstart.5.2.1.N1.1b.bin n5000-uk9.5.2.1.N1.1b.bin n5000-uk9-kickstart.5.1.3.N2.1b.bin n5000-uk9.5.1.3.N2.1b.bin
[Code]....
View 1 Replies
View Related
Nov 22, 2011
I attempted to enable jumbo frames on a Nexus 5010 (NX-OS version 4.2(1)N1(1)). I created the policy map below and lost access to the switch.
policy-map type network-qos jumbo
class type network-qos class-default
mtu 9216
After recovery I see from the logs that all vlans and interface were suspended. I've attempted to look for reasons for a compatibility issue but I am unable to find what is checked and what could have been incompatible. The other troubling thing is the adjacent switch suspended its interfaces too but no change was done there. What I need to look out for so that this does not happen again?
2011 Nov 22 23:43:09 phx-ipcg1dwfcma %ETHPORT-3-IF_ERROR_VLANS_SUSPENDED: VLANs 1,10,601 on Interface port-channel1 are being suspen
ded. (Reason: QoSMgr Network QoS configuration incompatible)
2011 Nov 22 23:43:09 phx-ipcg1dwfcma %ETHPORT-5-IF_TRUNK_DOWN: Interface port-channel1, vlan 1,10,601 down
2011 Nov 22 23:43:09 phx-ipcg1dwfcma %ETHPORT-3-IF_ERROR_VLANS_SUSPENDED: VLANs 10 on Interface port-channel508 are being suspended.
[code]....
View 9 Replies
View Related
Nov 4, 2010
We have two Nexus 5010 to test the solution. As part of the testing we upgraded the boxes from 4.2.1.N1.1 to 5.0.2.N1.1 and after the reboot the switch lost all of the VLANs. We put the VLANs back and when we got to the private VLANs we got the following error:
%PRIVATE_VLAN-2-PVLAN_ASSOC_UP_FAILED: Failed to bring up the association between 530 & 531
View 4 Replies
View Related
May 20, 2013
We have observed WS-C4507R-E got rebooted while creating the L3 VLAN ( while No shut).Is there any known bug for below IOS ?cat4500-entservicesk9-mz.122-40.SG.bin,
View 4 Replies
View Related
Mar 19, 2012
In my Cisco 3750 get rebooted and now the SFP module is not working.
It showing the following error message.
05:13:22: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP inte
rface Gi1/0/26
05:13:22: %GBIC_SECURITY_CRYPT-4-ID_MISMATCH: Identification check failed for GB
IC in port Gi1/0/26
What is the error message indicating and what is the solution for this.
View 1 Replies
View Related
Jun 6, 2011
I am experiencing an issue where NX-OS on our 5010s is allowing both Local AND TACACS authentication concurrently. If I don't configure any aaa authorization commands, the locally logged in user has unmitigated access to the device. Once I enable aaa authroization, all commands issued by the locally logged in user are denied by ACS, but they can still log in to the device. When I comb through the logs on the ACS server, I see successful logins when TACACS credentials are used, and also the failed attempts when the locally configured credentials are used. On the switch, however, I receive "%TACACS-3-TACACS_ERROR_MESSAGE: All servers failed to respond" when using locally configured credentials on the switch itself. We are running ACS v4.2.
View 6 Replies
View Related
Oct 2, 2012
One switch of our stack of 8 3750 have reboot with no reason. Nobody was in the room server when it appears et there was'nt any electrical problem at this moment.
View 4 Replies
View Related
Feb 22, 2010
Our customer is having C6513 running with 12.2(18)SXF15a . One of the module (ACE20-MOD-K9) got rebooted with following error:
Feb 22 10:41:41.155 GMT: %OIR-SP-3-PWRCYCLE: Card in module 6, is being power-cycled off (Reset - Module Reloaded During Download)Feb 22 10:41:41.183 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 6 set off (Reset - Module Reloaded During Download)Feb 22 10:41:53.686 GMT: %OIR-SP-3-PWRCYCLE: Card in module 6, is being power-cycled off (Module not responding to Keep Alive polling)Feb 22 10:41:53.686 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 6 set off (Module not responding to Keep Alive polling)
Code...
View 4 Replies
View Related
May 14, 2012
I am new to this and have ran into some problems. I butilt up my router I was able from the rom> prompt to get my router to boot from SLOT0:xxxxx
Then I did the copy command copy slot0:xxxxxxx bootflash:xxxxxxxMy router starts up fine. I did all my configurations and did my copy run start when I was done. As this is what I do on my 3750s.
My router lost power and rebooted and I lost everything it did not boot up to my last configuration.How do I save my configurations when I am done ? How do I get it to boot from that configuration every time?
View 1 Replies
View Related
Oct 14, 2012
if I can use the encrypted port as unencrypted ethernet ports? url.. Each individual port on the Cisco Nexus 5010 switch is numbered, and groups of ports are numbered based on their function. The ports are numbered top to bottom and left to right.There are 20 to 28 ports on the Cisco Nexus 5010 switch, depending on which GEM is installed.
The 20 fixed ports form group 1 and are named 1/port_number. Ports 1 through 16 are unencrypted Ethernet ports. Of these, ports 1 through 8 are 10-Gigabit Ethernet and 1-Gigabit Ethernet-capable ports. Ports 17 through 20 are encryption-capable Ethernet ports.
View 1 Replies
View Related
Feb 23, 2011
We are facing issue of continous packet discards On nexus4001L link (int po2) to Nexus5020 switch. Nexus4001L is installed in IBM blade center server and we have FCOE enabled in this setup. [code]
View 2 Replies
View Related
Mar 15, 2013
I have been tasked to replace the existing Cat 6500 and 3750 switches by Nexus 7000 and Nexus 2000.I was told initially my boss plans to get 2 x Nexus 7000 and then eventually blow up to 4 x Nexus 7000s.For Nexus, is there a list of tasks / points that i need to consider for building the initial design?
Can i just link the Nexus 7000 like the following?
N7k-A ========= N7k-B
| |
lots of N2ks lots of N2ks
View 12 Replies
View Related
Dec 22, 2011
Struggle to find the SNMP MIBS of the Nexus 5000 FEX tranceivers.
View 3 Replies
View Related
Nov 13, 2012
we are planning a Nexus datacenter project with this layout:Our experiences with Nexus switches are not so large until now and the manuals are very extensive.Both N5K´s should be connected directly with all 4 N2K switches. I did not find a layout like this in the manuals. Only a design,where only 2 N2K are connected to one N5K, with this fex config:Now I´m not sure if it is right to make a config like this with the same slots and fex´s or with different slots and fex´s.
View 1 Replies
View Related
Apr 9, 2010
Does the nexus 7010 support virtual switching yet? All of the posts I have found from about a year ago say that it is going to be supported, but there were no dates listed. I heard the same thing from Cisco a while back, but haven't followed up with it.If it is supported finally are there any configuration guides available for it?
View 7 Replies
View Related
Oct 8, 2012
Lucien is a customer support engineer at the Cisco Technical Assistance Center. He currently works in the data center switching team supporting customers on the Cisco Nexus 5000 and 2000. He was previously a technical leader within the network management team. Lucien holds a bachelor's degree in general engineering and a master's degree in computer science from Ecole des Mines d'Ales. He also holds the following certifications: CCIE #19945 in Routing and Switching, CCDP, DCNIS, and VCP #66183
View 1 Replies
View Related
May 16, 2013
We have our Nexus as our default gateway (101.1) and the default VLAN1 is setup with two subnets 101.X and 102.X. The DHCP server is using a superscope setup to accomodate the overflow of devices requesting IPs on 101, so when 101 is consumed persons are able to obtain a 102.X IP address. The setup is basic on superscope. The issue is some times the routing to the firewall with a 102.X is not always 100%. Somedays all goes well and the 102 subnet is routed out to the firewall and its a good day. However, such as today a 102.X address is not routing as it did 24 hours ago. I am perplexed as to why this is behaving unpredicatable. Here is running-config for VLAN1 to show the 102 as secondary address to VLAN1.
View 2 Replies
View Related
Feb 16, 2011
you find attached my network architecture with 2 Nexus 7010 on core layer and 2 Nexus 5020 on distribution layer, each one with 1 N2148T fabric extender switch. PC-A1 and PC-A2 are connected to one N2148T, PC-B1 is connected to the other N2148T. Nexus-7000-1 is HSRP Active for all VLANs, Nexus-7000-2 is HSRP standby. PC-A1 and PC-A2 are connected to VLAN A, PC-B1 is connected to VLAN B. PC-A1 and PC-A2 have the same default gateway correspondent to IP HSRP on VLAN A. It happens that PC-A1 is able to ping PC-B1 while PC-A2 is unable to ping PC-B1. If I issue a traceroute from PC-A2 I see Nexus-7000-2’s physical IP address as the first hop even if Nexus-7000-2 is HSRP standby. After the first hop the traceroute is lost. If I shutdown Port-channel 20 on Nexus-5000-2, PC-A2 starts to ping PC-B1.I can’t understand what’s wrong in this architecture.
View 6 Replies
View Related
Mar 25, 2012
I have an environment where i have two nexus 7010 switches, along with 2 nexus 5510's. I need to run OSPF as a layer 3 routing protocol between the vpc peer links. I have 1 link being used as a keep alive link, and 3 other links being used as a VpC link.
1) Is it best to configure a separate Vpc VLAN i.e 1010
2) Is it best to configure a vrf context keep-alive
3) just have the management address as the peer ip's.
View 2 Replies
View Related
Feb 6, 2012
I have a pair of 5548P switches with the L3 daughter cards installed. Using the base license as I just need RIP routing. I have the two switches setup and have the RIP routing feature enabled. When I "turn on" routing using RIP I do not get any routes from my existing L3 switch (3750). I probably don't have routing setup correctly. With the 3750 IOS, I just turned on RIP with the router rip command and added a couple of network statements. On the nexus I have run router rip {instance} and left it at that. I am not getting any routes from my 3750. The 5548s are using the management ports and are connected to my existing network with L2 trunks. Does any know of a setup guide for RIP? I have used the Nexus 7000 RIP guide but still can't get it to work.
View 2 Replies