Cisco Switching/Routing :: VPC Peer-link Between Nexus 5010 And 5020
Aug 7, 2012
I'm trying to create a vpc between a Nexus 5010 and Nexus 5020 switch. I recently upgraded the software so they are running the same version. I connect get a vpc link. Is there something wrong with my setup? Is a vpc between a 5010 and 5020 even possible? They are connected using a pair of Intel X520's in 802.3AD teaming mode. [code]
View 2 Replies
ADVERTISEMENT
Feb 23, 2011
We are facing issue of continous packet discards On nexus4001L link (int po2) to Nexus5020 switch. Nexus4001L is installed in IBM blade center server and we have FCOE enabled in this setup. [code]
View 2 Replies
View Related
Nov 23, 2011
I found intermittent link down(20~40 seconds average) occurred about 1~10 times every month. SAP reported a lot of active connections are disconnected and I used a batch to ping and found "requested time out" about 30 seconds.And Windows, SQL server, Nexus 5010 do not show any errors. We run cluster and cluster does not fail over.And I don't know which cables or nics cause this issue. When it happened, almost all servers are unreachable. For example, SQL server 1 -> SQL server 2, IBM HS22-1 -> SQL server 1. However, some connections are not dropped sometimes. It varies each time.PS: I run this topology last year without any problems but it started intermittent link down from 2011/1/7. Because there is no errors in Nexus 5010, it is difficult to troubleshoot. Cisco TAC recommended us to implement virtual port channel yesterday. Could I use "errdisable detect cause" to detect what caused the intermittent link down? Is there any error logs or switch parameters/status can use to troubleshoot?
View 18 Replies
View Related
May 5, 2013
Can you use twinax cables to connect two Nexus 7010 switches for VPC peer link? They would connect on F2 modules and have Sup2 on the chassis.
View 2 Replies
View Related
Apr 19, 2013
I have a pair of Nexus 5548UPs that have some high priority servers running on them. Servers are ESX hosts running Nexus 1000v's. Each host has multple connections in a VPC to both 5548s. We have been having intermittant ping loss and slowness of traffic to the VM's on these hosts. I was poking around trying to figure out what the issue could be and found that the peer-keepalive command was not set to send the heart beat across the mgmt0 interface. I would like to change this to point it accross the mgmt0 interface. Any tips or advice for me on making this change with production servers running on the switches? I do not want to cause any loss to any systems when I make this change. [Code] ..........
View 3 Replies
View Related
Mar 13, 2013
how the Nexus 5500s work ?currently we have two 6513 Core switches 6513-1 and 6513-2 running HSRP and RSTP. 6513-1 is currently the Root Bridge, 6513-2 is setup as our secondary root. We also have two 5548UPs setup with a peerlink between them. Picture attached. "Current Setup.jpg"
There is a 20gig port channel between the 6513s and also a 20gig port channel(peer link) between the 5548s. 5548-1 has a 10g fiber running back to 6513-1 and 5548-2 has a 10g fiber running back to 6513-2. Currently now Spanning tree is blocking the link from 6513-2 going to 5548-2 which is what we expect. We were working on moving some things to different racks the other day and moved switch 5548-2 to another rack and brought it back online without the peerlink fiber connected. We started to have issues and tried to plug the peer link back up, but still continued to have issues. We started to troubleshoot and noticed that both 5548s were acting like the master of the VPC domain and was not letting traffic pass accross the Peer Link. We then rebooted the 5548-2 with the thought that it would come back up as the secondary in the VPC domain. When it finally finished booting back up it then caused a huge loop in our network accross both uplinks to the 6513s and the 5548s peer link which in turn took our network down. Spanning tree did not work like it was suppose to and block the port going from 6513-2 to 5548-2 in time.
My thought was this didn't seem like a good setup. I went to the drawing board and decided we needed to have an uplink from both 5548-1 and 5548-2 going to 6513-1 setup as a port channel/VPC and also a uplink from 5548-1 and 5548-2 going to 6513-2 setup as a port channel/VPC. Picture Attached. "NewSetup.jpg" We are also planning on buying a "2K-C2224TP-1GE" to hang off the 5548s to use for ethernet.
how the Nexus 5ks work and haven't done a lot of research on them. Would this not be a better setup since both switches will have an active link to the root bridge? The links from the 5548s going to 6513-2 should always be in a block state until we loose both uplinks to 6513-1 or the entire switch itself correct? Also how will the 5548s reactive if I was to loose the Peer link fiber? Will they continue to work as normal? When it looses this Peer Link does it suspend all the VPCs for the servers on the secondary switch in the Domain so the network doesn't get confused on which link to send traffic up since there isn't a peer link active or is this not the case? Also with the peer link down will the 6513-1 know which 5548 to send the traffic to if there is only 1 device (not setup in a VPC) on one of the 5548s? What are your recommendations/best practice on the setup for the 2k?
View 6 Replies
View Related
May 27, 2012
The below nexus 5020 nx-os version and type/revision of my GLC-T is compatible with each other? I noticed also the "Transceiver calibration is invalid" when i do show int e1/8 transceiver details , what does it mean?
View 8 Replies
View Related
Oct 24, 2011
I have an alert from monitoring system about: “ fan for this system is not in the NORMAL state”. In the switch I found that the problem is with fex 3, see below:
Nexus5020# sh env fex 3 fan
Fan Fex: 3:
------------------------------------------------------
Fan Model Hw Status
------------------------------------------------------
Chassis N2K-C2148-FAN -- failure
PS-1 N2K-PAC-200W -- OK
PS-2 N2K-PAC-200W -- OK
Technician said: fans appear to be operational, BUT the only thing that appears abnormal is STAT light is amber (not sure what it means).
Also, if I compare the temperature from module 3 with module 2 (which doesn’t have an alert) is almost the same, this is why I think the fan is working fine, since module 3 is not hotter that module 2.
What I can do to reset this fan (chassis)?
View 2 Replies
View Related
Jan 22, 2012
I have two N5K (5020) switches with NX-OS - 5.0(3)N2(1). These two switches form VPC domain: peer-link = 2*10Gb ports (1/17-18) and peer-keepalive link over managements ports.Also I have two HP servers with two 10 Gb ports on each server.Each server conected by one link to each N5K switch (1/9-10). N5K downlinks configured as access ports with LACP Active mode.There is only one VLAN (1).When "no shut" command entered on N5K access ports - ports going in "not connected" status, begin flap and then going in "linkFlapErrDisabled" state.In attach - "sh run" from N5K.
View 1 Replies
View Related
May 6, 2013
We have two Nexus switches in our network, one of them is Nexus5020 other Nexus5596UP. System image is identical on both switches 5.2(1)N1(4). When we try to setup VPC between these switches we see that all configured vlans on VPC peer link between Nexus switches are blocked by spanning tree protocol with message "Bridge Assurance Inconsistent, VPC Peer-link Inconsistent". We still can't solve this problem.
Topology:
NEXUS_5020---Peer_link(Po2)---NEXUS_5596UP
/
/
Member_link (Po100) Member_link (Po100)
/
/
SERVER
Configuration:
NEXUS_5020:
speed 1000
interface Vlan2000
no shutdown
description VPC_keepalive_link
vrf member VPC_kepalive
ip address 10.55.55.2/30
View 2 Replies
View Related
May 29, 2012
Our customer is willing to have a Cisco Nexus 5020 to provide server connectivity and this Nexus would go connected to their core switch 6509. They are concern about Spanning tree compatibility between the Nexus and the 6509. Are they fully compatible for Spanning tree?
View 3 Replies
View Related
Mar 3, 2013
I have a customer who is having some issues with 5m passive HP twinax cables, 537965-001, with a Chelsio 10G NIC. Aside from NIC driver issue, if NX-OS recognizes this SFP+, should it be expected to work in a 5020 running 4.2(1)N1(1)? Whether Cisco has certified passive HP twinax cables? I have included output to 'transceiver details' to a Cisco twinax and the HP (WL GORE) cables.
Nexus5020# show interface eth 1/7 transceiver details
Ethernet1/7
sfp is present
name is CISCO-MOLEX
type is SFP-H10GB-CU3M
[code]....
View 2 Replies
View Related
Aug 12, 2012
I currenty have a Nexus 5010 connected to a core 3750X switch stack in a VPC trunk using 2 1Gbps links. I want to move this link to 2 10Gbps links without losing connectivity. So I want remove a 1G link and move it to 10G and then once that's up move the other 1G link to 10G hopefully without losing connectivity. So the question is, can I have a 1G and 10G link between the Nexus and 3750s in the same virtual port channel without causing problems?
View 3 Replies
View Related
Feb 9, 2013
Our Data Center Switch (5010) rebooted itself today, underneath the captured screen
NX5010-1(config-vlan)#
Broadcast message from root (console) (Sun Feb 10 14:22:41 2013):
The system is going down for reboot NOW!
NX5010-1# sh system reset-reason
----- reset reason for Supervisor-module 1 (from Supervisor in slot 1) ---
1) At 740938 usecs after Sun Feb 10 14:22:41 2013
Reason: Reset triggered due to HA policy of Reset
Service: nohms hap reset
Version: 5.0(2)N1(1)
[code]....
View 2 Replies
View Related
Nov 23, 2012
we have a old Nexus 5010 running version 5.0(3)N1(1)it is in a franckenblock(like frankenstein) ie . we bought the parts and create our own system design before VCE was created. He have since bought VCE V block for our production sites. we use the franc ken block to test before we migrate to the production v block 300 FIX the issue we have is the 5010 will only see two 1 Gb/s SFP fiber modules in the first 12 slots. All these slots are dual 1g/10G. If we add more than two, it claims not to see them. We tried swapping the sfp and using both sfg-GE-MM and GLC-SX-MM moduels, no difference at all 1g sfp are in the first 5 slots. only the first two slots are up.the others say "Link not connected" or "SFP not inserted"all five links are the same SFP and are plugged in other switches.the green link lights are on plugged in SFP, even when the CLI states they are not plugged uni tried both two types of 1 Gb/s SFP. sfg-GE-MM and GLC-SX-MM ,i move the sfp between slot 1,2 and 3,4,5. nothing changed,From "sh int brief" you can see that it can see the sfp ie they are all 1Gfrom "sh int status " it sees 1g but why does it say type 10G?why when i go to the "int e 1/5" and try switch port mode now, it can't mode and trunk at now there (;also how to i stop or clear EU51 %SYSMGR-2-TMP_DIR_FULL: System temporary directory usage is unexpectedly high at 87%.i put as much info in the attached file as i could.
View 1 Replies
View Related
Dec 11, 2011
We are looking for some latency in our net and I am trying to check if our STP implementations is running correctly - we have a simple flat network here and no blocked ports here - just two nx 5010 which are interconnected with two uplinks.A remote site - mirrored setup - with 2 10G dark fiber connections - one for each nx5010 - is connection a DR site. I have split the two sites in two stp domains by enabling bpdu-filter on the vpc between the two sites.
I have been running wireshark on the local segment for some time and see the STP RST ROOT announcement every 2. seconds - this is probably normal ? I was looking for some alternate root negotiation packets which would cause the mac tables to be flushed.
View 2 Replies
View Related
Jan 10, 2012
Can nexus 5010 supports inter v lan routing , as there is no core switch and router available in current network.
View 2 Replies
View Related
Jun 23, 2012
I am not able to create more than 256 VLAN in Cisco Nexus 5010 switch. While creating I am getting "No VLAN resources available for VLAN creation" Details below -
Switch model - 5010
Software : NX OS 4.0 (1a)
Error Message:
Nexus_5010(config)# vlan 417
ERROR: No VLAN resource available for VLAN creation.
View 5 Replies
View Related
Jul 20, 2010
My monitoring tool is reporting alerts for high cpu utilization on Nexus 5010.Image is 4.1(3)N1(1) Only command supported on this code is sh proc cpu.The output of which does not really tell what is the current cpu utilization.How do i troubleshoot the cause of high cpu on nexus switches.
View 12 Replies
View Related
Dec 6, 2011
I am trying to configure get the QLogic 8240 card to work properly in ESXi 5.0. I want to be able to send the iSCSI traffic down the iSCSI portion of the card and use the ethernet portion of the card to do NFS.
Here are my vlans I am working with..
vlan 420 = fcoe
vlan 500 = NFS
vlan 1000 = iSCSI
I have my interface currenly set as the following on the Nexus 5000.
interface Ethernet1/17
[Code]...
View 5 Replies
View Related
May 19, 2013
Basically I am trying to use Wireshark to do a packet capture on a Nexus 5010. I want to do a monitor session on on the switch so I can capture from a source port to a destination port on the same switch. I can configure the source port but when I go to configure the destination port I get "ERROR: Eth102/1/4: Configuration not allowed on fex interface". I have tried to reconfigure this port as a switchport but "switchport mode access" command does not take. I don't want to make any changes to any other ports but this one.
View 1 Replies
View Related
Feb 20, 2012
Here is an example of what each switch logs when a server drops offline. Sample logs taken between 5:32am and 5:35am on Feb 20. This particular one was having problems all weekend. Switch #1 encountered over 2000 interface resets. The corresponding VPC port on Switch #2 only had 13 resets.
NEXUS SWITCH #1
2012 Feb 20 05:32:09 q91-sw01-5010 %ETH_PORT_CHANNEL-5-FOP_CHANGED: port-channel10: first operational port changed
from Ethernet1/10 to none
2012 Feb 20 05:32:09 q91-sw01-5010 %ETH_PORT_CHANNEL-5-PORT_DOWN: port-channel10: Ethernet1/10 is down
2012 Feb 20 05:32:09 q91-sw01-5010 %ETH_PORT_CHANNEL-5-PORT_DOWN: port-channel10: port-channel10 is down
2012 Feb 20 05:32:09 q91-sw01-5010 %ETHPORT-5-IF_DOWN_PORT_CHANNEL_MEMBERS_DOWN: Interface port-channel10 is down (
No operational members)
[code].....
View 1 Replies
View Related
Feb 9, 2011
I'm not sure if I'm missing something basic here however i though that I'd ask the question. I recieved a request from a client who is trying to seperate traffic out of a IBM P780 - one set of VIO servers/clients (Prod) is tagged with vlan x going out LAG 1 and another set of VIO server/clients (Test) is tagged with vlan y and z going out LAG 2. The problem is that the management subnet for these devices is on one subnet.
The infrastructure is the host device is trunked via LACP etherchannel to Nexus 2148TP(5010) which than connects to the distribution layer being a Catalyst 6504 VSS. I have tried many things today, however I feel that the correct solution to get this working is to use an Isolated trunk (as the host device does not have private vlan functionality) even though there is no requirement for hosts to be segregated. I have configured:
1. Private vlan mapping on the SVI;
2. Primary vlan and association, and isolated vlan on Distribution (6504 VSS) and Access Layer (5010/2148)
3. All Vlans are trunked between switches
4. Private vlan isolated trunk and host mappings on the port-channel interface to the host (P780).
I haven't had any luck. What I am seeing is as soon as I configure the Primary vlan on the Nexus 5010 (v5.2) (vlan y | private-vlan primary), this vlan (y) does not forward on any trunk on the Nexus 5010 switch, even without any other private vlan configuration. I believe this may be the cause to most of the issues I am having. Has any one else experienced this behaviour. Also, I haven't had a lot of experience with Private Vlans so I might be missing some fundamentals with this configuration.
View 3 Replies
View Related
Sep 29, 2012
I have a 5010 that simply won't load any system image. Loads the kickstart image just fine, but once at the Switch(boot)# prompt just give me garbage when I enter "load bootflash:n5000-uk9.5.1.3.N2.1b.bin Restarting system.
Loader Version pr-1.3
loader> dirbootflash: lost+found n5000-uk9-kickstart.5.2.1.N1.1b.bin n5000-uk9.5.2.1.N1.1b.bin n5000-uk9-kickstart.5.1.3.N2.1b.bin n5000-uk9.5.1.3.N2.1b.bin
[Code]....
View 1 Replies
View Related
Nov 22, 2011
I attempted to enable jumbo frames on a Nexus 5010 (NX-OS version 4.2(1)N1(1)). I created the policy map below and lost access to the switch.
policy-map type network-qos jumbo
class type network-qos class-default
mtu 9216
After recovery I see from the logs that all vlans and interface were suspended. I've attempted to look for reasons for a compatibility issue but I am unable to find what is checked and what could have been incompatible. The other troubling thing is the adjacent switch suspended its interfaces too but no change was done there. What I need to look out for so that this does not happen again?
2011 Nov 22 23:43:09 phx-ipcg1dwfcma %ETHPORT-3-IF_ERROR_VLANS_SUSPENDED: VLANs 1,10,601 on Interface port-channel1 are being suspen
ded. (Reason: QoSMgr Network QoS configuration incompatible)
2011 Nov 22 23:43:09 phx-ipcg1dwfcma %ETHPORT-5-IF_TRUNK_DOWN: Interface port-channel1, vlan 1,10,601 down
2011 Nov 22 23:43:09 phx-ipcg1dwfcma %ETHPORT-3-IF_ERROR_VLANS_SUSPENDED: VLANs 10 on Interface port-channel508 are being suspended.
[code]....
View 9 Replies
View Related
Jan 2, 2013
We recently had a pair of Nexus 5k switches setup in our network. We had professional services handle the initial configuration but they weren't able to setup config sync for us. Each Fex is connected to each 5k, so we need a switch-profile to maintain a consistent setup on our interfaces. I went through the process in Configuring Switch-Profiles, but when I check the status of the peer, it says not reachable. [code]
View 1 Replies
View Related
Apr 18, 2012
we are planing to run HSRP on our Nexus 5ks (with L3 card) and we use VPC to connect the downstream UCS - Fabric Interconnects to the 5ks. I was wondering if the peer-gateway command is required under the vpc domain config? When you use HSRP with VPC, both the active and standby HSRP peers can forward layer3 traffic, isn`t that the same that peer-gateway would achieve?
View 1 Replies
View Related
Mar 25, 2012
I have an environment where i have two nexus 7010 switches, along with 2 nexus 5510's. I need to run OSPF as a layer 3 routing protocol between the vpc peer links. I have 1 link being used as a keep alive link, and 3 other links being used as a VpC link.
1) Is it best to configure a separate Vpc VLAN i.e 1010
2) Is it best to configure a vrf context keep-alive
3) just have the management address as the peer ip's.
View 2 Replies
View Related
Mar 17, 2013
I currently have Nexus 5596 pair with VPC peer link Po1 between them. My goal is to connect our new Nexus 7Ks to the 5K's using Fabric Path. My question is during this inital setup with the 7K's. Can I use the same port channel number on the 7K's as I did the 5K's? Is the port channel locally significat?
View 2 Replies
View Related
Apr 26, 2012
Trying to get the peer links to work and have them in interfaces E1/1-4 . When i do a show int status it looks like this and says sfp invalid. I see this on both sides. These same model gbics work fine attached to a FEX on these boxes.
Eth1/1 vpc peer link to T sfpInvali trunk full 10G Fabric Exte
Eth1/2 vpc peer link to T sfpInvali trunk full 10G Fabric Exte
Eth1/3 vpc peer link to T sfpInvali trunk full 10G Fabric Exte
Eth1/4 vpc peer link to T sfpInvali trunk full 10G Fabric Exte
Gbic in ports are this.
Ethernet1/1-4
transceiver is present
type is Fabric Extender Transceiver
name is CISCO-FINISAR
part number is FTLX8570D3BCL-C1
[code]....
View 5 Replies
View Related
Feb 25, 2013
I am working on wi-fi networks (ISP), So I need to block the peer to peer on my network.My network involves cisco switch 2950/2960, cisco 2800 routers and Access Points, config for peer to peer blocking, for this where I need to config either switches or router.My network basic setup is, The internet will pass from router to switch and then Access Points.
View 1 Replies
View Related
Feb 13, 2013
I am facing issues in blocking Peer to Peer applications in LAN. I am using 881 Cisco router and below is the config done. [code]
View 1 Replies
View Related
Jun 25, 2012
What is the function of the VPC peer-link? Should be the composite of all VPC links that are dual homed between switches? is it necessary to have 8 x 10G links as shown above. The links connecting the 7Ks to the 5Ks are VPC links.
View 3 Replies
View Related