Cisco WAN :: Nexus 5010 Fixed Port - Group C (17-20) Encrypted Ethernet Port
Oct 14, 2012
if I can use the encrypted port as unencrypted ethernet ports? url.. Each individual port on the Cisco Nexus 5010 switch is numbered, and groups of ports are numbered based on their function. The ports are numbered top to bottom and left to right.There are 20 to 28 ports on the Cisco Nexus 5010 switch, depending on which GEM is installed.
The 20 fixed ports form group 1 and are named 1/port_number. Ports 1 through 16 are unencrypted Ethernet ports. Of these, ports 1 through 8 are 10-Gigabit Ethernet and 1-Gigabit Ethernet-capable ports. Ports 17 through 20 are encryption-capable Ethernet ports.
View 1 Replies
ADVERTISEMENT
Jan 23, 2013
When I read Nexus 5K install guide , I found the follow :The Cisco Nexus 5596UP switch has the following features: # •48 fixed 1- and 10-Gigabit Ethernet server connection ports on the back of the switch AND The 48 fixed ports support 8-, 4-, 2-, or 1-Gbps Fibre Channel transceivers and 1- or 10-Gigabit Ethernet transceivers. Does these is a conflict ?The 48 fixed port on this switch support only 1- and 10-Gigabit Ethernet or 8-, 4-, 2-, or 1-Gbps Fibre Channel and 1- or 10-Gigabit simultaneously ?
View 2 Replies
View Related
May 19, 2013
Basically I am trying to use Wireshark to do a packet capture on a Nexus 5010. I want to do a monitor session on on the switch so I can capture from a source port to a destination port on the same switch. I can configure the source port but when I go to configure the destination port I get "ERROR: Eth102/1/4: Configuration not allowed on fex interface". I have tried to reconfigure this port as a switchport but "switchport mode access" command does not take. I don't want to make any changes to any other ports but this one.
View 1 Replies
View Related
Feb 20, 2012
Here is an example of what each switch logs when a server drops offline. Sample logs taken between 5:32am and 5:35am on Feb 20. This particular one was having problems all weekend. Switch #1 encountered over 2000 interface resets. The corresponding VPC port on Switch #2 only had 13 resets.
NEXUS SWITCH #1
2012 Feb 20 05:32:09 q91-sw01-5010 %ETH_PORT_CHANNEL-5-FOP_CHANGED: port-channel10: first operational port changed
from Ethernet1/10 to none
2012 Feb 20 05:32:09 q91-sw01-5010 %ETH_PORT_CHANNEL-5-PORT_DOWN: port-channel10: Ethernet1/10 is down
2012 Feb 20 05:32:09 q91-sw01-5010 %ETH_PORT_CHANNEL-5-PORT_DOWN: port-channel10: port-channel10 is down
2012 Feb 20 05:32:09 q91-sw01-5010 %ETHPORT-5-IF_DOWN_PORT_CHANNEL_MEMBERS_DOWN: Interface port-channel10 is down (
No operational members)
[code].....
View 1 Replies
View Related
Jan 25, 2012
How to remove the config from an ethernet port on a Nexus 5548 - send it back to factory default.
View 1 Replies
View Related
Feb 9, 2012
I'm unable to assign port E2/1 to port channel. I get following error:
NEXUS5K(config)# int e2/1
NEXUS5K(config-if)# switchport mode trunk
NEXUS5K(config-if)# channel-group 14 mode active
[Code].....
View 2 Replies
View Related
Jun 15, 2011
We have recently purchased some Cisco 3750x switches and we are getting complaints from users that the performance is poor when both the PC's NIC and switch port are fixed at 100/Full?
There are no errors or collisions on the switch interfaces so there is no obvious problem on the switch. The PC's are standard DELL Optiplex 755/760's
or gx 520's.
Any performance issues when configuring the switchport to 100/FULL?
View 2 Replies
View Related
Apr 4, 2012
I have a Cisco 857 router which i used for Internet connection with RJ11 connectior (ADSL0 POTS) but now the ISP has changed the internet link with PPOE type and the ONT connection is RJ45 , Is there a possibility to configure one os the Fast Ethernet ports as WAN port for internet.
View 2 Replies
View Related
Jul 3, 2012
There is no "blinking light" indication on my E3000 at the Internet (Yellow label) and Ethernet port no 4. I tried plugging in 2 cables at all of the ports. I got the blinking indication at Port 1 through 3. The same cable's have no response at Port 4 and Internet port. As a result my I am not able to connect to the internet.
View 2 Replies
View Related
Mar 24, 2011
We have configuration of Etherchannel in Cisco 6509 connecting to Cisco 6513 switch, both running on CatOS. This is a group of 8 ports in 6509, due to some reasons one port in Etherchannel group went bad. I have disabled that bad port now. Now I have to delete that bad port from etherchannel group (First task) and add a new port to the group ( 2nd task). I have tried many cisco documents to completely delete the etherchannel port, but no use.
View 8 Replies
View Related
Jul 19, 2011
How can I add devices onto the customizable group1? I am trying to creat a group of trunk ports and monitor just the up/down.
View 1 Replies
View Related
Nov 4, 2010
We have two Nexus 5010 to test the solution. As part of the testing we upgraded the boxes from 4.2.1.N1.1 to 5.0.2.N1.1 and after the reboot the switch lost all of the VLANs. We put the VLANs back and when we got to the private VLANs we got the following error:
%PRIVATE_VLAN-2-PVLAN_ASSOC_UP_FAILED: Failed to bring up the association between 530 & 531
View 4 Replies
View Related
Mar 8, 2012
Is there a way to view the utilization on a WS-X6148A-RJ-45 ASIC/port group?
View 7 Replies
View Related
May 27, 2012
I have two servers behind the RV180 and a list of ports I would like to open to the public (80, 443, 21, 3389).In that case, I have to setup 8 Access Rules. I am OK in the first time setting up.But later on, if I would like to change the external IP <-> internal IP mapping, I have to change the Access Rules one by one for all related ports.
Does it has a setting for grouping the ports together so that I can set the Access Rules by one time only ?BTW, the summary view of the Access Rules in RV180 is not very clear, I can't differentiate the Rules for different Destination NATs ... I have to click into the details one by one ...
View 1 Replies
View Related
Aug 12, 2012
I currenty have a Nexus 5010 connected to a core 3750X switch stack in a VPC trunk using 2 1Gbps links. I want to move this link to 2 10Gbps links without losing connectivity. So I want remove a 1G link and move it to 10G and then once that's up move the other 1G link to 10G hopefully without losing connectivity. So the question is, can I have a 1G and 10G link between the Nexus and 3750s in the same virtual port channel without causing problems?
View 3 Replies
View Related
Feb 9, 2013
Our Data Center Switch (5010) rebooted itself today, underneath the captured screen
NX5010-1(config-vlan)#
Broadcast message from root (console) (Sun Feb 10 14:22:41 2013):
The system is going down for reboot NOW!
NX5010-1# sh system reset-reason
----- reset reason for Supervisor-module 1 (from Supervisor in slot 1) ---
1) At 740938 usecs after Sun Feb 10 14:22:41 2013
Reason: Reset triggered due to HA policy of Reset
Service: nohms hap reset
Version: 5.0(2)N1(1)
[code]....
View 2 Replies
View Related
Dec 26, 2011
I've had trouble connecting to my own internet and have no wireless. I'm using my neighbor's wireless and it's really slowing her's down. I've tried restarting my laptop (it usually works) and then reinstalled the device under "device manager". It's not the cord, I've checked with my neighbor's laptop and it works fine.I use a Sony Vaio VGN-NS140E with Windows Vista SP2.
------------------------------------------------------------------------
{ipconfig /all} This is while I only have an ethernet plugged in and no wifi connection.
Windows IP Configuration
Host Name . . . . . . . . . . . . : FairyHo
[code]....
View 7 Replies
View Related
Nov 23, 2012
we have a old Nexus 5010 running version 5.0(3)N1(1)it is in a franckenblock(like frankenstein) ie . we bought the parts and create our own system design before VCE was created. He have since bought VCE V block for our production sites. we use the franc ken block to test before we migrate to the production v block 300 FIX the issue we have is the 5010 will only see two 1 Gb/s SFP fiber modules in the first 12 slots. All these slots are dual 1g/10G. If we add more than two, it claims not to see them. We tried swapping the sfp and using both sfg-GE-MM and GLC-SX-MM moduels, no difference at all 1g sfp are in the first 5 slots. only the first two slots are up.the others say "Link not connected" or "SFP not inserted"all five links are the same SFP and are plugged in other switches.the green link lights are on plugged in SFP, even when the CLI states they are not plugged uni tried both two types of 1 Gb/s SFP. sfg-GE-MM and GLC-SX-MM ,i move the sfp between slot 1,2 and 3,4,5. nothing changed,From "sh int brief" you can see that it can see the sfp ie they are all 1Gfrom "sh int status " it sees 1g but why does it say type 10G?why when i go to the "int e 1/5" and try switch port mode now, it can't mode and trunk at now there (;also how to i stop or clear EU51 %SYSMGR-2-TMP_DIR_FULL: System temporary directory usage is unexpectedly high at 87%.i put as much info in the attached file as i could.
View 1 Replies
View Related
Dec 11, 2011
We are looking for some latency in our net and I am trying to check if our STP implementations is running correctly - we have a simple flat network here and no blocked ports here - just two nx 5010 which are interconnected with two uplinks.A remote site - mirrored setup - with 2 10G dark fiber connections - one for each nx5010 - is connection a DR site. I have split the two sites in two stp domains by enabling bpdu-filter on the vpc between the two sites.
I have been running wireshark on the local segment for some time and see the STP RST ROOT announcement every 2. seconds - this is probably normal ? I was looking for some alternate root negotiation packets which would cause the mac tables to be flushed.
View 2 Replies
View Related
Jun 23, 2012
I am not able to create more than 256 VLAN in Cisco Nexus 5010 switch. While creating I am getting "No VLAN resources available for VLAN creation" Details below -
Switch model - 5010
Software : NX OS 4.0 (1a)
Error Message:
Nexus_5010(config)# vlan 417
ERROR: No VLAN resource available for VLAN creation.
View 5 Replies
View Related
Aug 7, 2012
I'm trying to create a vpc between a Nexus 5010 and Nexus 5020 switch. I recently upgraded the software so they are running the same version. I connect get a vpc link. Is there something wrong with my setup? Is a vpc between a 5010 and 5020 even possible? They are connected using a pair of Intel X520's in 802.3AD teaming mode. [code]
View 2 Replies
View Related
Jun 6, 2011
I am experiencing an issue where NX-OS on our 5010s is allowing both Local AND TACACS authentication concurrently. If I don't configure any aaa authorization commands, the locally logged in user has unmitigated access to the device. Once I enable aaa authroization, all commands issued by the locally logged in user are denied by ACS, but they can still log in to the device. When I comb through the logs on the ACS server, I see successful logins when TACACS credentials are used, and also the failed attempts when the locally configured credentials are used. On the switch, however, I receive "%TACACS-3-TACACS_ERROR_MESSAGE: All servers failed to respond" when using locally configured credentials on the switch itself. We are running ACS v4.2.
View 6 Replies
View Related
Jul 20, 2010
My monitoring tool is reporting alerts for high cpu utilization on Nexus 5010.Image is 4.1(3)N1(1) Only command supported on this code is sh proc cpu.The output of which does not really tell what is the current cpu utilization.How do i troubleshoot the cause of high cpu on nexus switches.
View 12 Replies
View Related
Apr 30, 2011
I have a Dell XPS M1530 with Vista 32 bit. When i plug in a cable i get nothing, no error, and the comp does not recognize that a cable has been plugged in. I think that this started after my Hard drive failed and Dell replaced it but i'm not positive. No errors (? or !) in Device Manager and I can't find the Marvell 88E80XX 10/100 Ethernet Controller in device manager. I have attempted to Reinstall the drivers. The wireless is still working. I have one Light to the right of the port that is on all the time solid but no flashing with the cable in or out.
View 14 Replies
View Related
Dec 6, 2011
I am trying to configure get the QLogic 8240 card to work properly in ESXi 5.0. I want to be able to send the iSCSI traffic down the iSCSI portion of the card and use the ethernet portion of the card to do NFS.
Here are my vlans I am working with..
vlan 420 = fcoe
vlan 500 = NFS
vlan 1000 = iSCSI
I have my interface currenly set as the following on the Nexus 5000.
interface Ethernet1/17
[Code]...
View 5 Replies
View Related
Nov 23, 2011
I found intermittent link down(20~40 seconds average) occurred about 1~10 times every month. SAP reported a lot of active connections are disconnected and I used a batch to ping and found "requested time out" about 30 seconds.And Windows, SQL server, Nexus 5010 do not show any errors. We run cluster and cluster does not fail over.And I don't know which cables or nics cause this issue. When it happened, almost all servers are unreachable. For example, SQL server 1 -> SQL server 2, IBM HS22-1 -> SQL server 1. However, some connections are not dropped sometimes. It varies each time.PS: I run this topology last year without any problems but it started intermittent link down from 2011/1/7. Because there is no errors in Nexus 5010, it is difficult to troubleshoot. Cisco TAC recommended us to implement virtual port channel yesterday. Could I use "errdisable detect cause" to detect what caused the intermittent link down? Is there any error logs or switch parameters/status can use to troubleshoot?
View 18 Replies
View Related
Feb 9, 2011
I'm not sure if I'm missing something basic here however i though that I'd ask the question. I recieved a request from a client who is trying to seperate traffic out of a IBM P780 - one set of VIO servers/clients (Prod) is tagged with vlan x going out LAG 1 and another set of VIO server/clients (Test) is tagged with vlan y and z going out LAG 2. The problem is that the management subnet for these devices is on one subnet.
The infrastructure is the host device is trunked via LACP etherchannel to Nexus 2148TP(5010) which than connects to the distribution layer being a Catalyst 6504 VSS. I have tried many things today, however I feel that the correct solution to get this working is to use an Isolated trunk (as the host device does not have private vlan functionality) even though there is no requirement for hosts to be segregated. I have configured:
1. Private vlan mapping on the SVI;
2. Primary vlan and association, and isolated vlan on Distribution (6504 VSS) and Access Layer (5010/2148)
3. All Vlans are trunked between switches
4. Private vlan isolated trunk and host mappings on the port-channel interface to the host (P780).
I haven't had any luck. What I am seeing is as soon as I configure the Primary vlan on the Nexus 5010 (v5.2) (vlan y | private-vlan primary), this vlan (y) does not forward on any trunk on the Nexus 5010 switch, even without any other private vlan configuration. I believe this may be the cause to most of the issues I am having. Has any one else experienced this behaviour. Also, I haven't had a lot of experience with Private Vlans so I might be missing some fundamentals with this configuration.
View 3 Replies
View Related
Sep 29, 2012
I have a 5010 that simply won't load any system image. Loads the kickstart image just fine, but once at the Switch(boot)# prompt just give me garbage when I enter "load bootflash:n5000-uk9.5.1.3.N2.1b.bin Restarting system.
Loader Version pr-1.3
loader> dirbootflash: lost+found n5000-uk9-kickstart.5.2.1.N1.1b.bin n5000-uk9.5.2.1.N1.1b.bin n5000-uk9-kickstart.5.1.3.N2.1b.bin n5000-uk9.5.1.3.N2.1b.bin
[Code]....
View 1 Replies
View Related
Nov 22, 2011
I attempted to enable jumbo frames on a Nexus 5010 (NX-OS version 4.2(1)N1(1)). I created the policy map below and lost access to the switch.
policy-map type network-qos jumbo
class type network-qos class-default
mtu 9216
After recovery I see from the logs that all vlans and interface were suspended. I've attempted to look for reasons for a compatibility issue but I am unable to find what is checked and what could have been incompatible. The other troubling thing is the adjacent switch suspended its interfaces too but no change was done there. What I need to look out for so that this does not happen again?
2011 Nov 22 23:43:09 phx-ipcg1dwfcma %ETHPORT-3-IF_ERROR_VLANS_SUSPENDED: VLANs 1,10,601 on Interface port-channel1 are being suspen
ded. (Reason: QoSMgr Network QoS configuration incompatible)
2011 Nov 22 23:43:09 phx-ipcg1dwfcma %ETHPORT-5-IF_TRUNK_DOWN: Interface port-channel1, vlan 1,10,601 down
2011 Nov 22 23:43:09 phx-ipcg1dwfcma %ETHPORT-3-IF_ERROR_VLANS_SUSPENDED: VLANs 10 on Interface port-channel508 are being suspended.
[code]....
View 9 Replies
View Related
Aug 15, 2012
I think I may have a bad port on a 5548, does the NX-OS has any sort of self-diagnostic test on its port?
View 6 Replies
View Related
Jan 16, 2011
I have configured my Nexus 7018 and 5548 as follow (see diag attached).Both 7000 and 5500 are vPC pair(po1and po2). Now I have created port-chanel between 7018and 5548 as port channel PO3 on 5500. Would it give me 20g bandwidth as PO3?or 10g only uplink to 7018? Do I need to config all four 10g links in PO3 on both 5500 and 7000 switches to achieve max b/w and failover?
View 4 Replies
View Related
May 22, 2012
I have port-channel configured on Nexus 5K (version 5.0.3) with below configuration.
interface Ethernet1/9
switchport mode trunk
switchport trunk allowed vlan 60
speed 1000
channel-group 105 mode active
[code]....
We have added GLC-SX-LH module to E1/1 and E1/10 and speed is set to 1000 (1Gig) Now other side of E1/9 and E1/10 are not connected. Port-channel status is down
Po105 1 eth trunk down No operational members 1000(D) lacp
show interface port-channel 105 shows different bandwidth (100) MTU 1500 bytes, BW 100000 Kbit, DLY 10 usec,question is under interface port-channel105 speed 1000 command inserted automatically.Now if we connect otherisde of interface, during port-channel comes up.what will be the port-channel interface bandwidth ? will it change to 2Gig(2000). Why speed 1000 command inserted automatically on port-channel.Since it is migration, we want to be more specific on the port-channel configuration?
View 1 Replies
View Related
Jun 29, 2011
I am going to install new Nexus 7K. Installed SUP and one 32-Port 10Gb module. When I open the box to install this 10Gb module, I saw that there is a carbon paper is tighted with ***** on the top of the module. confirm either it will insert in Switch with carbon paper or have to remove this carbon paper?
View 1 Replies
View Related