Cisco Switching/Routing :: IOS Installation For Switch 2960G 48TC-L?
Oct 23, 2012
i had made a software upgarde on the switch 2960G series have no any passwords, when I fished the upgrade process after rebooting the device i found it need a UserPw to access device manager. i tried to use the default PW "cisco" but it dosen't work too.. after that i tried the password recovery process to rest the PW, but noway, but now i have addition problem, when i try the cmd orders "flash_init , load_helper , dir flash" to beginning the password recovery process it shows the following:
The system has been interrupted prior to initializing theflash filesystem. The following commands will initializethe flash filesystem, and finish loading the operatingsystem software:
flash_init boot
switch: flash_initInitializing Flash...flashfs[0]: 554 files, 19 directoriesflashfs[0]: 0 orphaned files, 0 orphaned directoriesflashfs[0]: Total bytes: 32514048flashfs[0]: Bytes used: 15540224flashfs[0]: Bytes available: 16973824flashfs[0]: flashfs fsck took 10 seconds....done Initializing Flash.
switch: load_helperUnknown cmd: load_helper
switch: load_helperUnknown cmd: load_helper
switch: load_helperUnknown cmd: load_helper
[code]....
After that the problem updated
because I tried to install the IOS by Xmodem to reload the missing flash file.After finsh the TAR file loading and reboot the switch.......the LEDs of mode and Giga ports are lighted amber and not blinking, i tried many times to follow the steps to connect the switch by the emulator and consol cable by holding mode button and connecting the power cable at same time the device does not work, the switch now still not blinking, now i try to read and understand how can i remove the corrupted files and install a new IOS for this switch?What shall i do.
View 1 Replies
ADVERTISEMENT
Jun 26, 2012
I have a few 24-port Cisco 2960G Switches (model WS-C2960G-24TC-L) that I upgraded to IOS Release 15.0(1)SE2 using the web interface. I am now trying to upgrade those switches with the new release, 15.0(1)SE3, however I seem unable to do it, I have tried this on two switches so far, both have been upgraded to SE2 just a couple months ago or so, and both of them will not accept the SE3 upgrade, basically, I can select the tar file in the web browser and click "Upgrade" but when I do the status never changes from "Loading the tar file to the switch". I have tried multiple times from multiple computers using many different web browsers, including IE6 which is listed as supported. I have let it go for as long as 1.5 hours but to no avail.I also had a few idential switches here that had never been upgarded to SE2, I have had no problems loading SE3 onto them using the same method so it would seem that the tar file I have downloaded is valid.
View 5 Replies
View Related
Jun 11, 2013
I recently changed jobs and at the new location we are primarily running Catalyst 2960G series switches with the exception of one 3750. All of the switches are setup in a cluster with the 3750 being the cluster master. My question is what is the benefit of switch clustering? The entire network seems to be a bit over engineered for the our needs and I am hoping to scale it back a bit. For example, the the network was setup with VOIP QoS when there were no plans to even use VOIP. Also what procedures would I want to follow to disable the cluster to avoid any major outages? Assuming there is no real need for a cluster.
View 1 Replies
View Related
Jun 7, 2012
I'm trying to decide what switch to use as a core for 500 users. I'm currently looking at either 2 x 3750X stacks or 2 x 4500s with dual SUPs and PSUs, both options will provide the number of switchports required without the need for additonal access layer swiches. Which switch option is best to go for here? All of our services will be located in our data centre which will be connected using 2 1000Mbps MPLS circuits. I wont need any advanced L3 features and we are not likley to scale over 450 users. Also is it ok to use the dual switch stacks or chassis to provide the collapsed core/access layer or is it best to have a dedicated core (using one of the above options with less switchports) and having a dedicated accesss layer using 2960Gs for example. Our structured cabling terminates in a single comms room so we wont need to distribute switches throughout the office.
View 3 Replies
View Related
Oct 23, 2011
I have used all the ports on my 24 port 2960G and need to extend it with another 2960G. These switches do not have trunk ports so what is the best way to stack them and have all 5 vlans on both switches.Can I just use a port Channel trunk etherchannel ?
View 7 Replies
View Related
Jun 20, 2012
I have a Cisco 2960G switch and one of the ports was configured with srr-queue bandwidth limit 90 - I need to remove this bandwidth limiting from this interface. [code]
View 2 Replies
View Related
Dec 5, 2011
I have a requirement to monitor downstream data feed from a remote site and feed it to multiple destination devices for recording. The source data will be fed into a port on a Cisco 2960G switch then, using the monitor function, be forwarded to multiple interfaces. This works fine for normal Etherent II traffic. We tried a test using a device that generates IEEE 802.3 Raw packets ('type' field is used as a 'length' field) but found that while the traffic appeared to be accepted by the input port with no errors it was not forwarded to the destination ports, even when using the monitor function. I did try the 'encapsulation replicate' feature with no luck. It does not forward these packets even if I set all the ports into a common VLAN and let the switch just perform a normal switch function (non monitor).
if it is possible to get the IEEE 802.3 raw packets to pass through the switch and if it is, how to or what I need to do to make it work?
View 13 Replies
View Related
Jul 4, 2012
I am unable to access a series of switches connected together through a management vlan. I receive the message "The server xx.xx.xx.xx at level_15_access requires a username and password." Entering the username and password fails and the same username and password message returns. I am able to ssh into the switch with the username and password that fails trying to access the switch with the browser.
How can I check the username and password for access with the browser?
I am trying to monitor switch performance. Is there a good way to monitor switch performance with the command line interface?
View 2 Replies
View Related
Feb 11, 2013
I just got a Cisco 2960G 24-port gigabit switch so that our HP servers can have a Gigabit connection to the network. I moved 2 servers to it (HP Proliant DL380's) but they don't actually seem to be able to achieve even close to 1000Gbps. I ran same some LAN bandwidth tests and it was showing only around 200-300 Mbps between all of them. I also ran a network stress test utility, LAN Tornado, and it was showing packet loss as high as 60% when on gigabit, and only .07% when on 100Mbps.
-Both the NIC's and the switch ports are set to 1000/Full
-Currently using Cat5e cabling no more than 25Ft in length (I know Cat6 would be better but Cat5e is supposed to support Gigabit)
-All servers are on the same VLAN
Here are the port statistics when running just a stress test @ 10Mbps that had a 45% packet loss. What's odd though is when I set the servers and switches to 100Mbps, I get less than 1% packet loss.
GigabitEthernet1/0/16 is up, line protocol is up (connected)
Hardware is Gigabit Ethernet, address is 203a.07ff.7e90 (bia 203a.07ff.7e90)
MTU 9000 bytes, BW 1000000 Kbit/sec, DLY 10 usec,
[Code].....
View 2 Replies
View Related
Jan 16, 2013
I managed to upgrade this C2960G-48TC-L from 12.2.35-SE5 to 15.0.2-SE1 and now I can't connect anymore via telnet nor ssh. Console output simply shows
%% Low on memory; try again later
View 8 Replies
View Related
Jan 29, 2013
Switch A is: WS-C2960-48TC-S
Switch B is: SG 300-10MP
Neither switch supports a similiar transceiver module. We are looking at transceiver GLC-SX-MM for Switch A, and MGBSX1 for Switch B all the Layer-1 information (SX / wavelength, Multi Mode, etc.) I am able to find out about the two transceivers seems to match, so would there be any issue by having these 2 "different" transceivers at either end?
View 1 Replies
View Related
Jan 26, 2013
I have routing enabled, can build a static route, and go back and see it (sh ip route), but I don't know how to get the route right. I have one host (Host A) on Vlan 20 w/192.168.20.2/24 dg 192.168.20.11 (the vlan ip) and (Host B) on Vlan 30 w/192.168.30.2/24 dg 192.168.30.11 (the vlan ip). I can't ping them from any host man. I can ping the Vlans but not the host.
View 19 Replies
View Related
Feb 26, 2013
I have a 3com 2948 switch and is needing to put the configuration on a Cisco WS C2960 48 port switch. I am attaching the config to heck if that is correct. I know my IP will need to change to .123
View 7 Replies
View Related
Feb 3, 2013
one of our switches (WS-C2960G-24TC-L). When I try to turn on the lanbase-routing feature using sdm prefer lanbase-routing, it gives me an error (Unknown command). I tried "sdm prefer ?", and lanbase-routing wasn't there (only qos, default and dual IPv4 & IPv6). The switch is running on image C2960-LANBASEK9-M version 12.2(50)SE5.We have another switch (WS-C2960S-24TS-L), running on image C2960S-UNIVERSALK9-M version 12.2(55)SE5, and I can enable lanbase-routing feature. If I upgrade the WS-C2960G-24TC-L to version 12.2(55)SE5, will it be able to do inter-vlan routing? Or is the switch itself totally limited to VLAN configuration only?
View 4 Replies
View Related
Jun 14, 2012
i have a cisco catalyst 2960g and for some reason out of the blue, some interfaces go down and then up. It started doing it after a power cycle.
View 1 Replies
View Related
Dec 30, 2011
I have 2960G that in rommon status.I need that the switch work in 0x2102 (regular mode).I don't have a backup to configutratuio in my PC.I do wr before the switch go to rommon (startup config).What to do in order to the switch will be in 0x2102 (regular mode) with the same configuration( before the switch go to rommon)?
View 1 Replies
View Related
Oct 24, 2011
I have got a catalyst cisco 2960G series switch and via this switch I want to creat serveral vlans. I am getting a dhcp IP from a router and I want to setup my own vlan networks.
I plugged in the Ethernet cable that came from the dhcp router to port 16 of the cisco switch and configured the ports 1,2 and 3 for vlan 1, 2 and 3
the dhcp router has given me this IP 192.168.10.158 defautl gateway is : 192.168.10.1
when I plug in a PC to port 1 or 2 of the cisco switch I still receiving the IP from range 192.168.10.* but not from the range that I configured for the vlan 1 or 2.
Below is my startup configuration:
no file verify auto
spanning-tree mode pvst
spanning-tree extend system-id
[code].....
View 28 Replies
View Related
Jun 7, 2012
I have a 2960G that I keep on the bench as a work switch. I assigned an IP address to it. The techs have had trouble imaging workstations using GHOST. Do any config changes need to be made to enable multicast to work? Everything is in VLAN1 at this point and the GHOST server is also the DHCP server.
View 1 Replies
View Related
Dec 20, 2011
I got problem with wake on LAN software.. The software unable to ON all pc's remotely if sitting under different vlan. Everything is ok if using the same vlan. Below are the network diagram & switch configuration.
Layer 3 switch Intervlan routing configuration
ip forward-protocol udp 7
!
interface Vlan4
description vlan Client-WOL
ip address 172.22.51.253 255.255.254.0
ip access-group Deny_HTTP_Vlan1 in
ip helper-address 172.20.1.246
[code].....
After configured all the switches with the above setting, the software still cannot wake all the pc's using LAN. Base on sniffing, i can't find UDP port usage by the software. Attached here with print screen from wireshark.
View 7 Replies
View Related
Jun 21, 2012
I am unable to configure an interface using the "ip igmp filter <profile #>" command on a 2960G running 12.2(58)SE2. The switch allows me to create a profile using the "ip igmp profile <profile #>" global configuration command. It also lets me enable filtering with the global "ip igmp filter" command (which I didn't see in the documentation). But, the command is not accepted when configuring an interface. "ip igmp ?" does not even show "filter" as a valid auto-complete when in configure interface mode, and the command is rejected if I try to enter it.
I verified the command worked on a much earlier version of IOS, so it must have broken somewhere along the line. I'm wary of moving up to 15.0(1)SE. Is that a major IOS change?
View 5 Replies
View Related
Jul 24, 2012
My Cisco Catalyst 2960G-24TC-L is broken.Yes,I think it's broken.
1.Always dispaly : “ !!! WARNING: The switch is not usable !!! ” “Unable to create l2trace server process, socket_open() failed”.
2.All GigabitEthernet is missing .
Switch(config)#interface ?
Async Async interface
Auto-Template Auto-Template interface
[Code].....
View 5 Replies
View Related
Mar 27, 2012
Our database server is connected on cisco swich 2960G gigabitEthernet 0/38.while showing the interface command the total output drops is a large value..Is there any issue with this value.I think this is one of the reason for slow access of the server.
cisco6#show interfaces gigabitEthernet 0/38
GigabitEthernet0/38 is up, line protocol is up (connected)
Hardware is Gigabit Ethernet, address is 58bc.2746.45a6 (bia 58bc.2746.45a6)
[Code].....
View 5 Replies
View Related
Aug 8, 2012
Multicasting. The configuration is I have a 6506 as my core switch receiving multicasts from an interface assigned to VLAN10. I have a monitor port setup with a PC running Observer which says multicasts are being received on the core switch. On a different interface on the core switch I have a 2960G switch connected to it and this interface is on VLAN 10. The 2960G switch has a workstation connected to it that needs to receive the multicasts. How do I configure the 6506 and/or the 2960G to process the multicast traffic?
View 0 Replies
View Related
Mar 25, 2013
i have 2 no of 3560G in our core, now my requirement is to establish the redunent network like for the edge 2960G using stack or some other way ...
View 6 Replies
View Related
Jul 5, 2012
We run a network of several 2960G and 3650G switches in a network with a number of VLANs. One one particular VLAN (let's call it VLAN 10) it appears that non-broadcast traffic (i.e. normal unicast traffic) is being copied to every port in VLAN 10 only on one switch . The traffic is not crossing trunk ports and does not appear on other switches that have ports in VLAN 10. We first spotted this by noticing that a UPS port had an unusual amount of activity on our port througput graphs:
This traffic at 4 am is not expected and this profile is repeated across all ports in VLAN 10 on this switch (a WS-C2960S-48TD-L stack running IOS 15.0(1)SE3)\iffed one port using local SPAN (the UPS port) and discovered that this traffic was not broadcast, which was running at a normal low rate at all times. The traffic appeared to be unicast traffic from other ports of the sort you might see on a hub. It was from various hosts that live on VLAN 10, most (not all) of the conversations had one end station homed on the 'problem' switch. There are about 800 non-broadcast packets per hour and this is a busy VLAN so it does not account for all the traffic on the VLAN.
View 3 Replies
View Related
Feb 25, 2013
I had a bad power surge yesterday that took out a 2960g switch and the APC UPS that it was connected too. when plugged in the fan comes on and the syst light stays amber and the rps, stat, duplex. and speed light stay lit and the port lights for ports 21-24 stay lit. plugging it into the console on boot I cant even see rommon, so i dont think its even booting. I would like to find a pinout and voltage guide for the connector comming off the power supply so I can check the voltages coming off the power supply to tell if it is a bad PSU or if it took out the main board.
View 2 Replies
View Related
Aug 13, 2012
We have a switch in our IT office, Cisco 2960G. It plugs into the wall and goes to the server room and connects somewhere. This weekend we redid almost the whole server room and now this switch can connect to the rest of the network. The uplink has a link light but can get anything.
I have rebooted the switch, used scanning on our other switches to try and find the MAC of the switch but for the life of me I cant see it. Is there a command I can run from the command line of the switch to see where its pointing?
View 11 Replies
View Related
Jun 4, 2012
In our premises i want to configure cisco 2960G 24 port switch using hyper terminal commands.
View 1 Replies
View Related
Mar 1, 2012
I have 7 POE switches that have ESI IP phones attached. I have two VLANS, 1 and 2. VLAN 2 is used for voice and is defined in each switch.The ESI IP phones connect to my POE switch ports and the pc attaches through the ESI IP phone.
I have had voice quality issue between floors in my building. Talking to others on my floor via the IP phone, there are no voice quality issues. [code]
View 1 Replies
View Related
May 21, 2012
I have established dual-rlans on different segments.I have a 2960g switch. I created vl2 (management) and vl3 (data).I connected rlan1 (port4) to vl2 and rlan2 (port3) to vl3.My laptop receives a dhcp address on vl3 and the switch (in dhcp mode) receives it's proper address on vl2.Unfortunately a MAC is assigned to each vl and to the management interface. Thats 3 out of the 2 sets of 4.
So a managed switch is NOT the desired device to have on the back side of an OEAP600.In any case doing a show mac address-table revealed that all the vl2 MAC addresses were duplicated on vl3.To the tune of 216 addresses. 108 in each vlan. Which is a close match to the current host counts for each segment 98 + 18.Obviously this application is not what was envisioned by the OEAP team during work-up.The goal of 4 host devices on the rlan is proving difficult to achieve.The client wants 2 pc's and 2 digi-port servers.
View 1 Replies
View Related
Sep 24, 2012
A site that i am responsible for has the following equipment installed:
2 x 3750G Switches configured as a stack using Stackwise - Collapsed Core/Distribution Layer
5 x 2960G Switches as Access Layer switches
WAN connections into the Core/Distribution Layer are all Gigabit Ethernet over Fibre.This is a dedicated CCTV Network with 50 Cameras all streaming video into the Core (decoders connected to access switches)Each 2960G has 2 links to the Core/Distribution 3750G Switches, 1 to each switch - Gigabit.I'm running rapid-pvst on all switches, so spanning tree is blocking one of the ports and effectively halving the 2 gig bandwidth. Next year our customer is going to add in a further 50 - 60 cameras.After monitoring the current loading on the ports in use, we have suggested to the customer that the 2 connections to each should be Ether-channeled together. [code]
First interface takes commands no problem, keep getting the message that etherchannel cannot be configured across different switches in a stack when i try to put the second interface commands on.
View 8 Replies
View Related
Feb 1, 2012
What is the installation time for the Network Processor engine is:
NPE-G2=7200 series NPE-G2 engine with 3 GE/FE/E ports ,Do you reckon it can be done in two hours?
View 1 Replies
View Related
Apr 24, 2013
I have L3 switch 3560 v2 cisco switch. If i connect the switch via the console cable in XP system i am not getting any responce. I think i need to install via XY mode.
how can i install the ISO iamge via XY mode in cisco switch 3560 v2.Cisco Model: WS-C3560v2-48tS-S.
View 10 Replies
View Related