Cisco Wireless :: WRVS4400N - Power Supply Does Not Go Up To 240V

Jun 30, 2011

I just purchased the Cisco Small Business Wireless-N Gigabit Security Router with VPN (WRVS4400N). I'm moving overseas (to Israel) and noticed that the power supply does not go up to 240V. I then called the Cisco Customer Support and they told me that they don't have another power supply. Although they mentioned that I could probably get the unit in the country I'm going where it would already have the right power supply. Now, what I'm wonder, should I just send this back and figure it out when I get there? Or bring it with the hope of finding the right power supply?

View 1 Replies


ADVERTISEMENT

Cisco Switching/Routing :: Stack-power 3750x / FRU Power Supply Is Not Responding

Sep 4, 2012

After stacking two 3750X switches, with four equal power-supply's, with StackWise and PowerStack , still got the next message every few hours %PLATFORM_ENV-1-FRU_PS_ACCESS: FRU Power Supply is not responding (gn4m-rt1p08-04-2)( note that the message revers to the second switch in the stack ) although the stackwise and powerstack on the switches is oke and are working correctly. !
 
Config  : Stack-power in power-sharing mode/strict With CLI on the switch : All the power supply's and stack-power details, prio look OK.
 
Only: LMS prime /inventory/cisco-view/configure/power supply status  result :  some power supply's are marked as disabled.with the command  > power supply 2 slot a off/on I manage to get the status back to "normal", but after a few hours some power supply's are again marked as "disabled".
 
Looks like SNMP en IOS difference from opinion.
 
Hardware
WS-C3750X-24S-S
C3KX-PWR-350WAC
 
Software
15.0(2)SE
C3750E-UNIVERSALK9-M

View 5 Replies View Related

Cisco Switching/Routing :: 3750X Stand Alone Secondary Power Supply Act As Pool Of Power

Apr 4, 2012

In a stand alone 3750x switch configuration, can the secondary power supply only act as a redundant power supply (active/standby), or can it become a "pool" of power similar to power sharing mode for StackPower (somewhat active/active)?  I understand there is no stack involved here but I'm curious if this functionality is possible.

View 1 Replies View Related

Cisco Wireless :: Find EOS / EOL For 1130 Power Supply And Not For AP Itself

May 1, 2012

When is 1130 AP going eos/eol? I have tried searching, but could just find eos/eol for 1130 power supply and not for the AP itself.

View 6 Replies View Related

TL-WR740N - Wireless Connection Slow When Power Supply Not Plugged In

Oct 3, 2012

I have been using a Dell N5110 laptop with a wireless router from my internet provider for years without issues.I recently had the internet connected at my cottage. I am using a TP-Link router model TL-WR740N.All of my wireless devices function perfectly except my laptop.

View 2 Replies View Related

Cisco Wireless :: 4402 WLC / Plugging In Redundant On-board Power Supply

Aug 18, 2011

Is it possible for me to plug in and turn on on-board redundant power supply for a 4402 WLC that is already online and in production without any disruption to Wireless users and APs attached to that same controller?

View 1 Replies View Related

Cisco :: Power Supply In LMS 4?

Aug 4, 2011

I'm new on this version and I don't know how to create a Monitor/Alarm to detect that a power supply has gone down. I want to send a message.

View 1 Replies View Related

Cisco LAN :: Power Supply Requirement For SM-ES3G-16-P

Jul 1, 2012

I need 3925 router and i want to install SM-ES3G-16-P etherswitch module with PoE into it. So my question is do I need PoE power supply or not? Will PoE ports on this module work with basic AC power supply?

View 2 Replies View Related

Cisco :: C3750X Power Supply OIDs

Oct 8, 2012

We are trying to monitor two stacks of CISCO WS-c3750X running IOS 12.2.(58)SE.
 
We can get the state of the power supplies, but after a power cycle or reboot of the switches the identifier of ONE of the Power supplies ALWAYS change. The OIDs for the rest of the PS do not vary. The problem happens in the two stacks.

View 6 Replies View Related

Belkin Routers :: Power Supply For AC1200?

Nov 20, 2012

where i can buy a power adapter/supply for the AC1200 wireless router?

View 1 Replies View Related

Belkin Routers :: Power Supply 0.8A Or 1A For 15v F5D8633-4?

Apr 24, 2013

I need power supply for N wireless modem router F5D8633-4. It says 15v 0.8A on the router but I can only find 15v 1A available on the internet.

View 2 Replies View Related

Cisco :: 3750-X Redundant Power Supply Monitoring

Sep 21, 2012

We have 3750-X's with dual power supplies. When one of them is disconnected the NMS/Netcool is not picking up the trap. What MIB is needed to monitor the power supplies?

View 1 Replies View Related

Cisco WAN :: 7206VXR Adding Second Power Supply Live

Dec 8, 2010

Assuming the power on/off button is OFF on a new secondary power supply - would there be a problem with adding a second power supply to a running 7206VXR while live?

View 1 Replies View Related

Cisco WAN :: 6509-E Power Supply Failure Sh Log Output

Jan 31, 2012

I have a WS-C6509-E (R7000) and am trying to implement some proactive monitoring for environmental alerts. What is the output from a Power Supply failure for the following “sh log” “sh environment alarm”.

View 1 Replies View Related

WRT54G Running Just CAT 5e Cable Is Much Easier Than Having To Supply Power

Oct 2, 2012

I am looking to upgrade my home wifi from a Linksys WRT54G running DD-WRT to something that will handle .11n. I've been looking at the Unifi PoE APs. Their base model support N, but only on 2.4GHz, and only has a 100Mb port. I was concerned about that being a limiting factor. They've recently released a new line that supports Dual Band and has a Gig port, but it cost about 4 times as much. Here are my goals:

1.) PoE if possible. Currently the AP is my rack in the basement. I'l thinking of running an additional cable to somewhere central on the first floor and putting the AP there for better coverage/signal. Running just a CAT 5e cable is much easier than having to supply power as well. Second thought was to get two Unifi APs and setup a mesh with roaming, which it looks like they support, for best coverage. In that case I'd put one in a top floor room that already has CAT 5e.

2.) I'd really prefer access points to a router. I already have a pfsense box that does the routing. If this means getting something that will run DD-WRT, Tomato, or the like and turning it into an AP fine.

3.) I would like something that is dual band .11n.

4.) Something that support RADIUS

5.) Multiple SSID support and VLAN support. I want to be able to offer at least 2 separate networks.

So am I stuck buying the Unifi dual band AP? Or should I get something like the Asus RT-N66U and put Tomato on it?Does anyone have acutal expreience with the Unifi products?

View 19 Replies View Related

Cisco Switches :: Does SG500X Support Redundant Power Supply

Jun 1, 2013

Does SG500X support the following
 
redundant Power Supply?PIM sparse mode (PIM-SM), PIM dense mode (PIM-DM), and PIM sparse-dense mode?Layer 4 prioritization: enables prioritization based on TCP/UDP port numbersUni-Directional Link Detection (UDLD) — monitors a link between two switches and blocks the ports on both ends of the link if the link goes down at any point between the two devices 

View 2 Replies View Related

Cisco Switching/Routing :: 6509 NEB A Power Supply Not Working

Nov 20, 2011

The power supply on 6509 NEB A is not working with me . I have installed only one power supply on the box  WS-CAC-3000W
 
It is showing me that "Input OK , Output fail " from the LCD
 
 I tried with another WS-CAC-3000W , another power source but still same problem .

View 2 Replies View Related

Cisco Switching/Routing :: 2911 / K9 How To Determine If Power Supply Is AC / POE

Mar 12, 2013

I would like to ask if how can we determine by mear physical inspection if the power supply of a CISCO2911/K9 router is AC, POE or DC?  Do we have images of the actual spare power supply?

View 3 Replies View Related

Cisco Switching/Routing :: 6513E Power Supply Recommendations

Jan 25, 2012

Just received our new 6513E chassis and I am setting it up in the lab for testing. For prod we would like to run..
 
1 maybe 2 6704 10 gig cards
3 - 5 6748 cards
1 6724 SFP card

Sup720 setup, possibly upgrading to Sup32's in a few years, Right now for power supplies, I am using 2 WS-CAC-2500W ,But I have to run the supplies in combined mode to get all of the cards online.What power supply should I be looking to purchase for this chassis ?

View 2 Replies View Related

Cisco Switching/Routing :: 6509 Power Supply Incompatible With Fan

Nov 21, 2011

I have a 6509 box with the following modules:

View 4 Replies View Related

Cisco WAN :: 7206-CH Router - Power Supply Have Been Stopped Working?

Jul 19, 2011

I have a Cisco 7206-CH router and the power supply have been stopped working. I am very confused if the new " PWR-7200-ACE= " power supply can be used with this model which have been announced as end of sale and support from 2007.

View 3 Replies View Related

Cisco Switching/Routing :: AC Power Supply With PoE For Ethernet Modules In ISR G2

Dec 12, 2012

While configuring PoE Ethernet EHWIC PoE modules with ISR G2 routers Cisco DCT gives a warning to select AC Power Supply with PoE ‘PWR-3900-POE’. Do we need to select the PoE power supply for Enhanced EtherSwitch SM PoE modules also (at present it does nt show any warnings)?

View 1 Replies View Related

Cisco :: LMS 4.2 Didn't Notify When Power Supply Stops Working

Dec 6, 2012

i have router 7200 , one of its power supply stops working , but lms 4.2 doesn't notify me?

View 6 Replies View Related

Cisco Switching/Routing :: Power Supply Cord For 4500?

Apr 3, 2012

Currently I am using 1000W power supply in Cisco 4500 and I want to upgrade to 2800W power supply.My question is
 
1) Whether I have to change the power cord while upgrading power supply

2)Whether power cord comes along with the Power Supply while ordering from Cisco

View 1 Replies View Related

Cisco Switching/Routing :: 3825 Redundant Power Supply?

Sep 3, 2012

I was wondering if there was a way to disable the RPS in a 3825? When I do a Sho Env All I get the following;

Redundant Power System is present.
RPS is in standby state
Redundant Power System is present.
RPS is in standby state
 
How ever there is no RPS in the system. At least not that I know of. There is only one power supply.

View 4 Replies View Related

Cisco Routers :: WRP400 Part Number Of Power-supply Of Router

Feb 26, 2013

What is the part number of the power-supply of this router (WRP400)? [code]

View 6 Replies View Related

Cisco Switching/Routing :: 48VDC Power Supply For 819 4G LTE Router In Q1 2013?

Dec 14, 2012

clarify whether this statement found after table 4 of the Cisco 819 4G router data sheet truly means that there will be a power supply to support 48VDC in Q1 of 2013?  Here is the statement:
 
"* Future external reference for 24V, 52V, and 72V DC for railway applications Q1CY2013"
 
Here is the data sheet source: 
 
[URL] 
 
I would want to power this router from a -48VDC plant, which is common at remote telecom sites.

View 1 Replies View Related

Cisco Switching/Routing :: Insert Secondary Power Supply To 3560?

May 22, 2013

while the 3560 switch is running?  Is it hot-pluggable?   
 
WS-C3560X-48P is the switch and I would be adding a C3KX-PWR-1100WAC

View 1 Replies View Related

Cisco Switching/Routing :: Finding Specification For 3750x PoE Power Supply?

Jul 11, 2012

Looking at the specs for the 3750 power supply - is the WS-C3750X-48P-S model with the 715W power supply referring to the amount for both power supplies per switch or just one power supply per switch? Meaning, is the 715 a accumulative number or, just the watts of one power supply. I would like to purchase a 3750x PoE switch with redundant power supplies. If this model is not the correct one?give me the model that offers 48 port PoE with redundant power supplies?

View 6 Replies View Related

Cisco Switching/Routing :: Power Supply Error Switch 3750

Dec 3, 2011

power supply problem...?Switch cisco WS-C3750-24P is showing "Unavail" from sh env all.Switch3750#sh env all FAN is OK,TEMPERATURE is OK,SW  PID,Serial#     Status Sys Pwr  PoE Pwr  Watts,Does it means that power supply 1 was removed? failed?,Do you know about another command to see more details?

View 3 Replies View Related

Cisco Switching/Routing :: 4506E Switch Power Supply Upgrade

Dec 8, 2012

I would like to check if it may be possible to hot-upgrade/swap the 4506E power supplies? Based on the configuration guide; I have summarized the steps as follows:

1. Switch has 2 existing power supplies to be upgraded

2. Remove right side/bay 2 power supply and install new power supply

3. At this point; the new power supply will be in err-disabled due to different power supplies on the switch

4. Remove the left side power supply and install new power supply

For item 4; during the removal of the old power supply in bay 1/left side and installation of the new power supply; I am wondering if the switch would lose power even though the new power supply is installed in bay 2?

View 1 Replies View Related

Cisco Switching/Routing :: ASR 1001 - Adding Redundant Power Supply?

Dec 23, 2012

I was wondering if I am able to add a redundant power supply to an asr 1001 router that is in production without losing connectivity or causing any diruption to the Users  - is it hotswappable?

View 1 Replies View Related

Cisco Switching/Routing :: Power Supply Compatibility From 4500 To 6500

May 9, 2013

can I plug power supply from 4500 to 6500? more specifically we have power supply PWR-C45-1300ACV. And we need to place some power supply to 6500, which has only one active module. So 1300 should be enough for it. But we dont know if they are physically compatible, if it is possible to plug. I didnt find this power supply to be officially?

View 4 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved