About an hour ago I had the master switch on one of my 3750x (WS-C3750X-48PF-S) stacks crash. The only two items we've found that could have caused this issue are the roughly 1.3 million big buffer misses and several of the following in the syslog
SLT:WARN:No exporter configured for smartlog! I do not have smartlogging turned on, nor is there a netflow exporter configured
sh logging smartlogsmartlog is disabledsmartlog exporter:smartlog pkt length: 64 Total pkts processed: 0Total DHCP Snooping pkts processed: 0Total DAI pkts processed: 0Total IPSG pkts processed: 0Total ACL pkts processed: 0
I did not see any traffic spikes prior to the crash.
This stack has been stable since it's last IOS upgrade from 12.2(58)SE1 to 12.2(58)SE2 back in October 2011 so this has me a little worried.
We have 2 3750 24 port fiber switches in a stack and we would like to change the member to become the master. Both are running the same IOS and they are alive on the network. I read that you can change the who becomes the master by setting the priority number higher on the member, which we did. However this requires a reboot of the member to take effect. Is there a way to force this without having to reboot? One other note, both switches in stack have a single gig connection that goes to the core (6500). One gig link is blocked due to spanning-tree and this is on the member that we want to become the master.
I have a stack of 2960S (c2960s-universalk9-mz.122-55.SE2.bin) and the master has failed (used to have a priority of 14). The second switch has become master (priority 1) as can be seen below: [code]
If I connect a new blank 2960S (same IOS) through the stack ports, will the master sync its config to the new one without causing problems?As I understand the new blank switch will also have a priority of 1 and will by default be numbered as 1. So if the config is correctly synced and I later on want to make switch 1 the master, I need to set the priority: [code]
The switch 6500-E is frequently crashing whenever the pm scp process reach 100% .I got it under the command "remote command switch show proce cpu".How to solve the problem. I opened the TAC and the engineer says to upgrade the image12.2(18) sxf.Is there any other work around that would avoid to reimage the switch and reloading.
I am not able to find the exact bug for Cisco 3750E stack - Debug Exception (Could be NULL pointer dereference) Exception (0x2000) error. Closest i can find is CSCsa72400 which only affects ver 12.2(20)SE4.All the stacks (3 switches) are running 12.2(50)SE3, It appears that the switch 1 crashed and reloaded. My hunch is its software but i cant find any related bugs. It could be hardware issue as well ?
Our switch had a little crash-fest this morning at 2:30 AM. I did find a web page about diagnosing Software Forced Crash Exceptions, but it did not look like ours was one of the more easily-identifiable ones.
It may be worth noting that we've only used this switch for about a month, everything seemed fine until now. When we got the switch it did not have any GigE modules, and this week we put 2 into it and have been using them for 2 servers.
It looks like the switch was crashing repeatedly over a period of 20 minutes, and then it stopped and normalized. In the logs of the router that this switch uplinks into, we could see the ethernet port flapping during the time that the switch wasn't reachable.
Here's the Show Stack on the switch:
Sfld_3550# show stackMinimum process stacks:Free/Size Name4404/6000 vegas_flash init3352/6000 SaveCrashBuffer5716/6000 CDP BLOB8512/9000 IP Background5596/6000 vqpc_shim_create_addr_tbl5584/6000 SPAN Subsystem5552/6000 SASL MAIN4944/6000 vegas IPC process8704/9000 cdp init process5404/6000 RADIUS INITCONFIG4928/6000 Vegas CrashBuffer5664/6000 URPF stats2536/3000 Rom Random Update
It seems I have seen this before (and even done it once a few years ago).. but it has been a while. I have a stack with a Cisco 3750 stack that I have to replace a member.The replacement switch is a 3750X.
I think I have to upgrade the IOS of the older switch to be the same as the 3750X.
Current switch: WS-C3750G-48TS 12.2(46)SE TO BE ADDED WS-c3570X-48 15.0 (1)SE2
It seems to me there was a way to upgrade the older switch IOS from the newer switch or downgrade the newer switch with the older IOS.I dont have the Cisco account to download updated IOSs.
my company pay a switch 3750 X. WS-C3750X-24T-E. It uses IP services basically but I failed to configure InterVLAN routing. why interVLAN routing doesn't work on my switch?
when enabling multicasting on layer 3 interfaces the CPU becomes fully utilized , is there any specific configuration should be enabled to reduce this .
Config :
Inetface vlan 100 ip pim sparse-dense ip igmp version 3
I have a 3750X 24 port switch (with NM-1G network module) running IOS 15.0(1). Is there any benefit or reason to plug in the included Stack Wise cable and loop it back to itself in a single switch installation?
I don't see any recommendation in the documentation. The data sheet indicates a single switch is a non-blocking device so I'd think there's no bandwidth advantage like there is when connecting an actual multi-switch stack and needing to close the loop for the full 32 Gbps stack bandwidth.
I've 3750X switch that isn't loading email. then I went to rommon mode and accidently for "format flash". after that I loaded 15.0 SE2 s/w on it using tftp server but it doesn't boot up with that image. flash had only .bin file after I loaded it from tftp server.
since it wasn't booting up, I did format flash again and thought to load image again from tftp server but now, it doesn't load image from tftp server.
I have a 3750X four-switch stack acting as the core of a fairly simple LAN. All I need to achieve (and this seems inordinately hard, but it is entirely likely that I'm just being dense) is to get access to the internet through my core switch, through the firewall and out through my VSAT. I've spoken at some length with the firewall providers (Cyberoam) and they tell me all I need to do when I migrate onto my new system (Cyberoam is currently in place at the entrance to our existing LAN) is change the local IP address of the Firewall, plug in the new switch to the LAN port, and away I go. Tried that, didn't work, so obviously I'm missing something.
I am looking for a way to bind between a switch interface (cat 3750X) and a DHCP server reply.The switch can operate as the DHCP server .a PC connected to interface Gi 1/0/1 will lways get IP address 10.0.0.1 because it is connected to interface Gi 1/0/1, a PC connected to interface Gi 1/0/5 will lways get IP address 10.0.0.5 because it is connected to interface Gi 1/0/5 and so on... (no matter the source MAC address who sends the DHCP request).
i am seeing very high utilization on a random basis on the stack. and the logs indicate me that there is a pattern where there is a stack power cable shows inserted (which was never unplugged) followed by sudden spike in the utilization.
001018: *Mar 6 16:21:22.138: %PLATFORM_STACKPOWER-6-CABLE_EVENT: Switch 4 stack power cable 1 inserted 001019: *Mar 6 18:18:37.982: %SYS-1-CPURISINGTHRESHOLD: Threshold: Total CPU
I work at a hospital and we have 3750X-48P switches in stacks in various locations throughout the hospital. We have noticed that when an EKG machine is plugged into one of the ports on some of these switches and the EKG machines are set manually to 100/Full, the ports are no longer usable until the switch is restarted. The switch is configured for auto. If the EKG machine is set to auto, it will work and not cause problems. The link on the interface will show up/up and there will be output packets increasing. However, there will be no inputs on the link and the port is unusable. Unfortunately, even when the device is removed, the port becomes unusable for any device. Is there any way to fix this problem without rebooting the switch?
In change network topology, we are going to assign PC's Gateway as Switch (3750X) IP Address rather than server IP Address. Currently we have configured all Sytems's Gateway is Internet Server IP Address which we are going to replace with Switch IP as Gateway.Issue is while connecting specific application like team viewer in which application tried to send keepalive message to the live server and in case of switch/router IP as gateway. Connection doesn't established. However it is working fine when Internet Server IP treated as gateway.
We have a 3750X VTP Server and the rest of the switches are clients.
Due to cabling issues, we have a switch (Switch F) that we can't connect directly to the 3750X so we have it connected through another switch. Everything is set to VTP client with the correct domain and password but this not-directly-connected switch isn't receiving any VTP VLANs.
Anything I need to do on Switch D so that Switch F can receive the VTP updates?
I have a LIII Switch Cisco 3750x ,with diffrent Vlans , Some users are in Vlan 102 (10.10.2.0) and Some Users are in Vlan1 (10.10.1.0) , now i want to restrict the Vlan102 users to access Vlan1 , i am pasting my configuration below , how to create a access list .
interface Vlan1 ip address 10.10.1.36 255.255.255.0 ip helper-address 10.10.1.36
In my environment we have 3750x switches running ios 15.0 (1) SE2. We have port security mac address sticky configured on all our switch ports. I noticed that we have several interfaces (on different switches) that are up but have not captured the MAC address from the workstation. Here is one example:
I want to limit the bandwidth going to remote site on the switch connecting to our netapp.We have a 4 port channel group setup on our 3750x switch going to our netapp storage. We have a Wan 100mb link to our remote site and we want only 60MBs of that link to be used for Netapp traffic all other local traffic needs to use the full amount of the bandwidth to the netapp.
Is possible to allocate bandwidth in this way and how would I go about this? We dont have access to the routers for the link and they plug directly into a port on our cisco.
I have a 3750x 48port POE switch that I installed a second power supply in. But it doesnt power on. Am I supposed to enable it in the switch somewhere? I've plugged it into a couple different outlets so I know that's not the problem.
Is there a switch that handle its 24/48 ports at 10 Gbps with copper?. I have checked 3750 X but just handle 2 SFP with 10 Gbps.The requirement is to use this switch as CORE and connect 12 switches (access) using its uplinks at 10 Gbps with copper ( in this case 3750 X can be used).using copper at 10 Gbps the distance is still 100 m?
I'm trying to get an IP_ADDR set on the management port in SWITCH: mode but for some reason the port seems disabled. PC shows connection unplugged. MGMT_INIT is not a valid command (not listed under '?' ). Bootloader version is 12.2(53R)SE2 FC1.
What are the options avilable to add a cat3560 g switch to a stack of 3750x switches.?is there a connector avilable ?or is it possible to trunk via fiber ? cat 3560 has 4 sfps and 224 10/100/1000 ports with poe. cat 3750 stack has a 10 gb up link . What are the possible options?
In change network topology, we are going to assign PC's Gateway as Switch (3750X) IP Address rather than server IP Address. Currently we have configured all Sytems's Gateway is Internet Server IP Address which we are going to replace with Switch IP as Gateway. [code]
Issue is while connecting specific application like team viewer in which application tried to send keep alive message to the live server and in case of switch/router IP as gateway. Connection doesn't established. However it is working fine when Internet Server IP treated as gateway.