Cisco Switching/Routing :: Information About PoE Of Switch 2960S
Jan 21, 2013
I use the Switch 2960S support PoE and 10 access points cisco.I have one more question:
-- If all 10 access points cisco use copper cable to connect to 2960S, 5 access points use power adapter and 5 access points use power from Switch. How Switch 2960S will provide power for 10 AP or switch 2960S will understand and only provide power for 5 APs?
I have a running setup having 2 Cisco 2960s 24 TS switch with Stack configuration. Now I want to add one more same Cisco switch. My questions are:-
1) How can I do this...(Should follow the same process as I did before.
2) Could I do this without impacting the service. i.e. without rebooting the switch.
3) What should be the connection archiecture as of now since there is two switch so it is connected 1 -1 and 2-2. but for 3 switch should we require to change the connectivity.
We have a Cat2960-S Series PoE+ currently running 12.2(55) SE5 ios with SW image C2960S-UNIVERSALK9-M.We want to upgrade the ios to the lastest version but found there are 2 version: 12.2(53) SE2 and 15.0(1) SE.Which is the best & suitable for upgrade?
After i have already configured my cisco switch 2960 , i configured my console as the below [code] after i reboot my switch , i found that the switch asked me for username . However i did not configure username , how can i solve this problem , without password reset . I have already configured 15 switch , 100% this problem will be in all switches.
I have hybrid network in which I want to configure VLAN on Cisco 2960 S switch. I have unmanged switch where my DHCP server and other servers are connected. Now I created two VLANs on cisco 2960S and they don't talk each other, but as soon as I connect unmanaged switch to 2960S switch, both VLANs start communicating which I don't want. I want to listen server traffic from unmanaged switch from both VLANs but simultaneously I don't want to communication between two VLANs.
I have enabled syslog on my Cisco 2960S swtich as shown below -
-logging facility local6 -logging host 10.11.12.122 transport tcp port 514
I have sent the port to TCP since that is what is configured on the SYSLOG server which is a CENTOS 5.8, running rsyslogd.I have tested the rsyslogd locally and it work.However i want to send any and all log messages in the buffer to my syslog server and it is not working.there is no firewall on the CENTOS and the ASA firewall filter is enabled for outgoing traffic.
I have a problem with extending the LAN on a client site . They are looking to extend the LAN with a 2960S-series switch. Already in place is a 4510 switch which the 2960 is connected to via fibre. The 2 switches are both set up but there is no connectivity as I cant ping between them or anything. The management VLAN on the 2960 shows line up, protocol down, which I believe means the VLAN is enabled but there is a form of physical mismtach on the ports. I have attached the configs of both switches. I feel it might be a problem with GBIC module compatibility. The SFP installed on both ends of the switch are GLC-SX-MMD. On the 4510, the SFP sits in a twingig converter (CVR-X2-SFP) but there is no light on it at all when the cables are plugged in.
I have a stack of 2960S (c2960s-universalk9-mz.122-55.SE2.bin) and the master has failed (used to have a priority of 14). The second switch has become master (priority 1) as can be seen below: [code]
If I connect a new blank 2960S (same IOS) through the stack ports, will the master sync its config to the new one without causing problems?As I understand the new blank switch will also have a priority of 1 and will by default be numbered as 1. So if the config is correctly synced and I later on want to make switch 1 the master, I need to set the priority: [code]
I have a live 28port Catalyst 2960S switch. By live I mean that there is an essential piece of equipment plugged into this switch that can suffer little to no downtime. Over the course of time the number of devices patched into this location has increased to exceed the 24 ports available and we have had to resort to adding unmanaged switches to fill the need. We have acquired an additional 2960 & stacking modules that I would like to stack together, keeping the existing switch as the master. It is my understanding that the stacking modules are hot-swappable and that this member switch can be added without bringing the master switch down, thus creating zero down time for the financial server that is connected.
The steps I believe that need to be followed are as such: write mem to existing switch and backup to our TFTP serverinstall the stack module in the existing (while powered up) and new (while powered down)place the 2 redundant FlexStack link cables on both switchesthen simply power the member switch on After boot the member switch will get it's OS and configuration from the master and I can begin moving CAT5 cables from the unmanaged switches to the stack.
I have a Cisco 2960S stack and I'd like to tune the timers so that packet loss is minimal if a switch fails.To simulate a failed switch I have reloaded it while running a continuous ping to a management address on the stack's SVI: [code] As I see the same results when a ping is directed through the single switch (switched), and through the firewall (routed), I'm inclined to think that this is due to the stack failover timers on the Catalyst 2960S.Is it possible to change the stack failover timers (i.e hold down, failover etc), to speed up the failover process?
I have a new Cisco 2960 S series switch with a basic configuration that needs to be uplinked or daisy chained to a Cisco 3750 switch. I am not getting any connectivity to the network with either a straight through or crossover cable. the port remains in amber but a 'show interface' indicates that the interface is up. I can manage the switch with a PC patched into any port on the switch with a static IP address. Must be something very simple that I am missing. Outlined below is the configuration.
We have Cisco Catalyst 6509-V-E VSS Switch with Sup2T und IOS Version 15.0(1)SY2. We are gettin input netflow information from the gi2/3/7 but not output ... I am not sure why it does not work.
Looking at the following output (show interface status) from one of our 4507s I see gig interfaces 3/2 to 3/6 are all trunked (dot1q). When I look at a show run they do not show as trunked. They should indicate switchport trunk encapsulation dot1q and switchport mode trunk (as does interface gig4/2). I have seven other 4507s all running the same IOS: 12.2(25)EWA8 and they all show the same information in show run and show interface status (as far as trunked goes). This is not a problem as I know the interfaces are trunked and working properly I am just puzzled as to why I see this difference.
Here is the sho int gig3/2 trunk. It looks like you are correct. I did not realize some were set to trunk mode on and others were not. I would think the running config would still show the port using dot1q but I guess not.
How to get a summary of netflow statistics on NX-OS? On IOS you could do sh ip cache flow which would show what I need? Can't find a similar command on the Nexus Platform.
I have recently split the voice vlan (10) from the data network (1), and am wondering why my catalysts and router do not require an interface Vlan10 statement. In the past I used OpenBSD boxes to do the routing, and I first needed to configure vlan 10 on the interface before I could get inter-vlan communication to work. With these Cisco devices it works, and I am wondering if it is because of VTP, for the fact that the ports maybe just pass all traffic, or is there some other explanation? Below is the setup, and firmware is up-to-date on all of the devices.
When I plug a phone into the POE SGE, the phone turns on, obtains an address on the proper subnet, and conversations are clear (whereas without the ip nat inside on the new subnet the calls had a lot of static). Possibly the reason that it works is because the phones properly create the tcp/ip packet, and it hops over the trunks and creates the states so that traffic routes back properly. I will install wireshark to see exactly what is going on, but is there a simple explanation that I am overlooking?
I come across to use the Catalyst Switch 2955 and it has two Relay Connector with one Major (MAJ) and one Minor (MIN) as below picture.There is command line to trigger these two Relay Connectors. As below command to set the Relay Connector to minor for monitoring the power supply: alarm facility power-supply relay minor
1. My questions are when there is power-supply faulty, the Minor Relay Connctor (right picture) will be short-circuited, right?
2. If we connector the two ports (ports 4 & 5 at the left picture) with a normal cable to drive an Alram Bell (in short-circuiled or closed loop situation), do we need an external power supply to the Alram Bell? Or there will be power supply from Catalyst 2955 to the Alram Bell as well?
I need to extract the serial numbers of SFPs which are plugged in a SG-200-18.For information, SG-200 doesn't have a CLI ... only a Web GUI.I just find this information : [URL]
I have 2 NEXUS switches in VPC. When I create/delete a VLAN gets updated in the same switch, but the VLAN information does not get propagated to the neighboring switch. Revision number remains the same even if I modify the VLAN. Had also tried changing the VTP status to transparent mode & reverting it to client mode but no luck.Have double confirmed on the VTP domain names & password. However the same setup in different location which works perfectly fine.
I have C2960S-48FPS-L and C2960S-24TS-S both of them are using C2960S-UNVERSALK9-M image with version 15.0(2)SE on both I run "mls qos"
and on 48FPS-L I run "mls qos map cos-dscp..."on 24TS-S I cannot run it. there is no such command. there is just "mls qos rewrite..." and "mls qos srr-queue..." variants.
I thought that one image give the same set of commands...?
I'm trying to view the logs from a Cisco 857W router to a workstation running the Kiwi Syslog server. what I've done is the following:
Config term
Logging on
Logging source-interface BVI1
Logging Facility Local7 (or any other facility you want to allocate for this router.)
Logging [IP Address or Hostname of machine running Kiwi Syslog Server]
End
I see noting on the syslog server. Although I can see the log information on the router Also is there a command to stop the logging from generating or is this on by default.
while i am configuring a port on switch .The switch reloads.After reload the show version says,System returned to ROM by bus error at PC 0x458F6C, address 0x0,show version from the effected switch is,Cisco IOS Software, C3750E Software (C3750E-UNIVERSALK9-M), Version 12.2(58)SE2, RELEASE SOFTWARE (fc1).
I am currently having an issue with connecting a Catalyst 2960-S switch to a Small Business SG300 switch. When I connect them they are unable to form a link. When I do a show spanning-tree it says the mst link is in dispute.
I read some papers about QoS. The thing is that I have to implement 30 switches with QoS to connect to a lot of Cisco IP phones. The switches are Cisco 2960S with code image "C2960S Software (C2960S-UNIVERSALK9-M), Version 12.2(55)SE3". Should I use autoQoS feature or manually configure them?. How should I treat uplinks between access switchs and core/distribution? I have a lot of doubts regarding queueing, because all the info I had read its for another model/image.
I'm looking at the WS-C2960S-48TD-L and have a question about the uplink ports. Is it possible to mix 10G on one uplink and 1G on the other? The datasheet says 2x10G SFP+, 2x1G SFP so I am thinking mixing is not possible.
just got new hardware and decided to try the newer USB port for IOS upgrades. I could not get the switch to recognize my 2gig flash drive. Do I need a proprietary stick or special format?
I also noticed when I removed it the switches crash dump and rebooted?
My 2811 sip gateway send invite to my ITSP server with incorrect IP address in Contact section. It uses the internal ip address instead of using the public ip. As results, the re-invite sent back from ITSP sip server cannot be recieve. Could some tell how to change the ip address in Contact section of the invite message.
When using dynamic configuration tools, if I choose 2960 (not 2960s), I have the option to choose RPS2300 as redundant power, but when I choose 2960s, I cannot choose RPS2300. However, in a document describe both 2960 and 2960s, it said that RPS2300 can be used. Does RPS2300 support 2960S?