Cisco Switching/Routing :: Input Discard On Nexus 4001?
Nov 17, 2011
I have 2 NX4001. Each one has an uplink to a 5K. There is no VPC between the 4K and the 5K. The 5K are VPC enabled.There is a large number on input discards on the 4001 interfaces connected to the 5K and is incrementing.I have a server with smartfailover that is flapping and I think the input discard might be the culprit.what is the cause on input discard. Note: All NXOS to the latest.
View 2 Replies
ADVERTISEMENT
Feb 23, 2011
We are facing issue of continous packet discards On nexus4001L link (int po2) to Nexus5020 switch. Nexus4001L is installed in IBM blade center server and we have FCOE enabled in this setup. [code]
View 2 Replies
View Related
Jan 19, 2012
we have a core switch 4507RE at the data center and 2 departments that connect to it via 10Gig fiber using X2-LRM modules. Each department has a 3 switch stack and both locations are identical w.r.t type and setup scenario.the stack comprises of 1 x 3750E and 2 x 3750G . uplink is from X2 port tengig3/0/1 from the 3750E switch.
All of a sudden dept B started facing problem , where the ping would break and throughput comes around 6 - 7 mbps from that dept to the server behind the core switch. we also noted CRC error on both sides preodically.
we replaced the multimode fiber patch cords, re did the splicing , which stopped the CRC errors to appear.now since morning the uplink port on the 3750E (3/0/1) would suddenly be in "down" state with (err-disabled) as the status when i run sh int ten 3/0/1
and i can also see CRC errors and input errors on the same interface.. if i do shut / no shut .. the port is up and active again.. but this has happned 3 times today.the core swith side is still OK and no CRC / input / output errors are seen..
now on the 3750E i have swapped the 10gig module from 3/0/1 to 3/0/2 . the port is still up but i can see 400 CRC and 500 Input errrors.the module is also OK as i had replaced it with dept 1's module.
View 1 Replies
View Related
Apr 4, 2011
We're seeing "OutDiscard" error on a LAN switch connected to newly migrated Cisco IP phones. All the other error counters are clean except for the OutDiscard. (please see attached "show int count err" output.) [URL].
According to the link above, the common cause of such discards can be to free up buffer space.(Am I seeing a switch buffer issue?) How to identify/resolve the cause of the OutDiscard.The switch is 3750-E running c3750e-universalk9-mz.122-44.SE6.bin
View 1 Replies
View Related
May 21, 2013
I faced the ( receive discard vlan 20 of Cisco switch 3560 ) on my Solarwinds Server .
View 1 Replies
View Related
Dec 6, 2012
reasons for increasing "Output Discard” Interface Counter in Nexus2000 . ????
View 2 Replies
View Related
Apr 15, 2010
I have two 3560G 24 port switches. Each of them connects to some 3560G or 2950 switches. Trunks between 3560G are set as 1000/full. Trunks between 3560G and 2950 are set as 100/full. show int status also shows the interface negotiation is 100/full for trunks between 3560G and 2950. The issue is I keep getting outdiscard errors in trunks between 3560G and 2950. At 2950 switches, I see Recv-errors too. I checked all the trunks traffic. They are totally not high. Only serveal mbps. Most time even lower than 1mbps.
I googled this kind of issue online. I see it could be possibly caused by high volume traffic higher than the capacity. But it appears the traffic there is not high enough to cause this kind of issue. Is there any possiblity that could cause this problem?
The below is 3560G trunk configuration for 2950 switch
interface GigabitEthernet0/10 switchport trunk encapsulation dot1q switchport trunk allowed vlan 1-122,124-4094 switchport mode trunk speed 100 duplex full srr-queue bandwidth share 10 10 60 20 queue-set 2 priority-queue out mls qos trust cos auto qos voip trust
the trunk configuration at 2950 switch: interface FastEthernet0/24 switchport trunk allowed vlan 1-122,124-4094 speed 100 duplex full
View 16 Replies
View Related
Feb 13, 2012
As always, the Cisco LMS is keep sending the follwoing high discard error from the Cisco switches WS-C2950T-24:
EVENT ID = 0004SX3
ALERT ID = 00019LF
TIME = Tue 14-Feb-2012 08:56:35 GMT
[Code].....
View 4 Replies
View Related
Feb 4, 2013
my 3750-E Core Stack is connected to the Provider Router and is the DG for the internal LAN. I saw that the CPU is very high also in the night, but I found not the problem. I use an SVI to connect the provider due to HA reasons. I sniffered the network but saw no ecessive broadcaststorms. There was a PBR configured but I deleted it wihtout any success..
switch Version
15.0(1)SE1
10#sh proc cpu so
[Code]......
View 6 Replies
View Related
Mar 15, 2013
I have been tasked to replace the existing Cat 6500 and 3750 switches by Nexus 7000 and Nexus 2000.I was told initially my boss plans to get 2 x Nexus 7000 and then eventually blow up to 4 x Nexus 7000s.For Nexus, is there a list of tasks / points that i need to consider for building the initial design?
Can i just link the Nexus 7000 like the following?
N7k-A ========= N7k-B
| |
lots of N2ks lots of N2ks
View 12 Replies
View Related
Dec 22, 2011
Struggle to find the SNMP MIBS of the Nexus 5000 FEX tranceivers.
View 3 Replies
View Related
Nov 13, 2012
we are planning a Nexus datacenter project with this layout:Our experiences with Nexus switches are not so large until now and the manuals are very extensive.Both N5K´s should be connected directly with all 4 N2K switches. I did not find a layout like this in the manuals. Only a design,where only 2 N2K are connected to one N5K, with this fex config:Now I´m not sure if it is right to make a config like this with the same slots and fex´s or with different slots and fex´s.
View 1 Replies
View Related
Apr 16, 2013
We are facing since one month in our two Cisco WS-C3750G-12S on many interfaces input errors when data transer or ping (ICMP) increase input erros. Not only port 1 but many interface has same issue, i have change new IOS but still same issue, once i have erase startup config but same issue we are facing and finaly i have replace same new switch with the same IOS it's working fine.(c3750-ipservicesk9-mz.122-55.SE4.bin) [code]
View 11 Replies
View Related
Jun 17, 2012
What does RP drops entail? We are experiencing 0.23 % drops on an vlan int on one of our 6500. This interface is an L3 to a server-subnet. Doing a sh int vlan 238 switching shows 30935411 RP (Route Processing) drops.It was a bit unclear to me in the thread "Input queue drops on 6500 vlan interface" if RP drops was through the router, or to the router(mgmnt)?I can do a netdr to see what traffic goes to it. It should not generate CPU load, but I think I will wait until after hours before I try that command.
- do NETDR:
-- debug netdr cap rx vlan 238
-- show netdr cap
View 5 Replies
View Related
Oct 27, 2011
I have a 6509E switch with dual 6Kw power supply that is logging "Power supply 1 input has changed. Power capacity adjusted to 2671.20W" then will bounce back to normal at random times from 1sec to 10sec. Is there a command to check what each input level of the power supply to try to identify possibly which source is causing the problem? The power supply input lights remains green while this is occuring.
View 3 Replies
View Related
Jul 1, 2012
I am not sure why the CRC and input errors are increasing in fastethernet port...This port is used as Intradomain cross connect to Data Center service provider for LAN extension between two Data Centers in different locations... The link is 100 MB. The switch port is directly connected to patch panel of DC provider and I believe they have some L3 switch or some other device that is providing LAN extension...
#sh interfaces fastEthernet 0/23
FastEthernet0/23 is up, line protocol is up (connected)
Hardware is Fast Ethernet, address is 0019.3050.1497 (bia 0019.3050.1497)
Description: ASA_VPN_TO
MTU 1500 bytes, BW 100000 Kbit, DLY 100 usec,
[code]....
View 26 Replies
View Related
Oct 2, 2012
I am not sure why the CRC and input errors are increasing in fastethernet port...This port is used as Intradomain cross connect to Data Center service provider for LAN extension between two Data Centers in different locations... The link is 100 MB. The switch port is directly connected to patch panel of DC provider and I believe they have some L3 switch or some other device that is providing LAN extension...
#sh interfaces fastEthernet 0/23
FastEthernet0/23 is up, line protocol is up (connected)
Hardware is Fast Ethernet, address is 0019.3050.1497 (bia 0019.3050.1497)
[Code].....
View 3 Replies
View Related
Feb 6, 2012
We are experiencing with high CPU input due to ARP input between 20:30 and 22:30 every day At this time we have a lot of backup operations. When I look the netflow report, I can't see anything anormal.
We are changing our backup server's NIC card from 1gig to 10Gig. The backup operation's traffic is high (approx 2Gbps level) but 6509 has to be handle this size of traffic.
We are using two 6509E in VSS mode and our image version is s72033-adventerprisek9_wan-mz.122-33.SXJ.bin
20:00
show ip arp summary
--------------
2588 IP ARP entries, with 166 of them incomplete
[Code].....
View 16 Replies
View Related
Oct 1, 2011
We added Site02 for redundancy and DR. Also added new SAN and ESX hosts. The CPU on device Site01Server01 is not very happy when files are being transferred between the sites. Since the setup is the same at both sites, why is the problem only at site01?
Site02 is newer and we have two 3750X-24 with IOS 12.2(55)SE3 on ipservices, for site02server01; no problem.
Site01server01 is a stack of two 3750G-24PS with IOS 12.2(58)SE on ipservices.
[Code]....
View 5 Replies
View Related
Nov 10, 2011
I have some trouble with that policy-map on my 2960 or 3560 switches with LAN base 12.2(53)SE2. I want to use that feature to catch video traffic from webcams in laptops which can't send dscp values out of the box. This is my test config to check if the function is working: catch every traffic from my workstation for testing, access-list 101 permit ip any any, class-map match-all CL_TEST
1. I can't see any counters with the command "sh policy-map interface FastEthernet 0/1". Cisco tells that this command is not possible. But how I can see if the policy is working correct?
2. When I did the configuration I can't see any packets with dscp af41 on the out going interface on the switch with "sh mls qos int gi0/1 statistic" as I expected. After reloading the switch I see the pakets with af41. Okay for that moment. But.After that I changed something in the policy-map. Only "set ip dscp ef" for a second test.
Generating some traffic I see only packets with af41 as before I changed the policy-map. No traffic with ef on the outgoing interface.
View 4 Replies
View Related
Mar 15, 2013
I have an ASR 1002x connected to a 6513. Connection is from ASR Gig Copper SFP to 6513 Copper 10/100/1000 port. The ASR is recevinig Runt and input errors. I have removed the negotiation auto command on both boxes and hard coded the speed etc and still errors occur. I have also added the negotiation auto to both devices and also removed it with out hard coding the speed at and same results. Everytime I have seen these errors is has been to collision caused by a duplex mismatch.
View 4 Replies
View Related
Jun 7, 2012
I have a video feed coming into my 3570. It comes in at 5 minute input rate 18777000 bits/sec, 1695 packets/sec. However, the uplink to the router is much different, 5 minute output rate 130000 bits/sec, 28 packets/sec. I am in a lab and about ready to go into testing phase for a project when we discovered this problem, as this video feed is not veiwable on the other end.
Below is the config and capture from the switch.
BLOSSw1#sh int g1/0/6GigabitEthernet1/0/6 is up, line protocol is up (connected) Hardware is Gigabit Ethernet, address is a44c.112f.3506 (bia a44c.112f.3506) MTU 1500 bytes, BW 1000000 Kbit/sec, DLY 10 usec, reliability 255/255, txload 1/255, rxload 4/255 Encapsulation ARPA, loopback not set Keepalive not set Full-duplex, 1000Mb/s, link type is auto, media type is 10/100/1000BaseTX SFP input flow-control is off, output flow-control is unsupported ARP type: ARPA, ARP Timeout 04:00:00 Last input never, output 00:00:00, output hang never Last clearing of "show interface" counters 15:16:25 Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0 Queueing strategy: fifo Output queue: 0/40 (size/max) 5 minute
[code]....
View 2 Replies
View Related
Sep 8, 2012
I can see drops on one of our busy L3 vlan in the input queue and are going up very frequently.System image file is "sup-bootflash:s72033-psv-mz.122-18.SXD3.binHardware = 6509
View 1 Replies
View Related
Mar 11, 2013
I have an odd situation where I cannot get a device connected to a built in switchport with out input and crc errors. When connecting to a GLC-T sfp it works fine.Here is my test layout
Outdoor wireless AP --- 10' of cat6 cable --- Gigabit POE injector --- 10' Cat6 cable --- 3560G port 48. (input and crc errors)
When I do this there are input and crc errors on the switch port. This has been confirmed on three different switches and three different outdoor AP's. We though at first it was the injector, but when we run the same setup, but instead connect the device to port 49 with a GLC-T sfp there are no errors.
Outdoor wireless AP --- 10' of cat6 cable --- Gigabit POE injector --- 10' Cat6 cable --- 3560G port 49 (GLC-T). (No errors)
I have upgraded the 3560G to the latest ios and still it has the same problem. If I run the same setup to a 2960 there are no errors at all.
Outdoor wireless AP --- 10' of cat6 cable --- Gigabit POE injector --- 10' Cat6 cable --- 2960 port g0/1 (No errors)
I have also tried manually setting the speed on the 3560G with no success.
View 9 Replies
View Related
Sep 15, 2012
What are recommended commands to get input for network documentation (for disaster recovery)?
I've got 6500 with these modules: WS-SVC-FWM-1,
WS-SVC-IDSM-2, VS-S720-10G, WS-X6704-10GE, WS-X6748-SFP and dozens of WS-C3750E-48TD in couple of buildings.
So far I have these commands: Code...
View 3 Replies
View Related
Mar 6, 2013
On my SUP-7E, when I issue a " show interface vlan X " I cannot see the expected input/rate reflecting the real rate (which should be very high).
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 4000 bits/sec, 2 packets/sec
(Under the physical interfaces it is ok)However on other SUP-IV I can see the real rate.
My questions are :
- Why the SUP-7E does not reflect the rate, whereas the SUP-IV does ?
- I have heard about the 'counter' command under the vlan interface to activate the rate counters. Is this command application has any side effect on the switch ?
View 2 Replies
View Related
Sep 3, 2012
We have Cisco ME3400 switch, with configuration described below.
GE0/1 port is uplink:
interface GigabitEthernet0/1
description ***MATED-IUB_C&U-Plan***
port-type nni
switchport trunk allowed vlan 331,450,4085
switchport mode trunk
GEo/2 is configured as below:
interface GigabitEthernet0/2
description ***From NIB***
port-type nni
switchport access vlan 4085
[URL]
We have also tried Loopguard feature enabled on all ports: but after some period same problem is repeated.
version information is below:
Cisco IOS Software, ME340x Software (ME340x-METROIPACCESSK9-M), Version 12.2(25)SEG3, RELEASE SOFTWARE (fc2)
Copyright (c) 1986-2007 by Cisco Systems, Inc.
Compiled Wed 25-Jul-07 22:56 by amvarma
View 8 Replies
View Related
Jan 6, 2013
interface Vlan24
description Internal Wireless Internet
ip address 10.x.0.1 255.255.254.0
[Code]....
So, I am trying to limit the bandwidth used by this vlan. The service-policy output statement works, the service-policy input statement does not. My test is to get on that vlan and go to speedtest.net. My download speeds are about 3.5Mb/s, my upload speeds are about 20Mb/s.
it has something to do with this:
sh mls qos ip
QoS Summary [IPv4]: (* - shared aggregates, Mod - switch module Sid - Switch Id)
Int Sid Mod Dir Class-map DSCP Agg Trust Fl AgForward-By AgPoliced-By
[Code].....
View 1 Replies
View Related
Feb 25, 2013
I have a connection that is loosing packets, my show interface output below summarises the interface where i believe the problem is occuring. My Hardware is 6509 running 12.2
View 1 Replies
View Related
Nov 9, 2011
i have issues logging into one of our core switches.its a 6509 switch but i cannot log in remotely.when i try to console in on the console port, i cannot log in instead i get the above error message.I haven't rebooted yet but would it solve the problem as this switch is a production switch.
View 6 Replies
View Related
Feb 10, 2012
I feel that 3560 and 3750 perform differently with the following two commands:
srr-queue bandwidth shape 5 0 0 0
srr-queue bandwidth limit 50
On 3750, the bandwidth for queue 1 is limited to 100mbps x 50% / 5 = 10mbps
On 3560, the bandwidth for queue 1 is limited to the smaller value of BW / shape weight and BW x limit%.
Does it sound about right? is there a way to check for mls qos input queue drops? The show mls qos interface xxx stat only shows the output queue drops. Maybe for some reason the input queue never drops?
View 6 Replies
View Related
Jan 9, 2012
I have a switch 4948, with version 12.2.31.sga4 ( I dont found bug about monitor session) and we try to made port mirroring with a monitor session from a VLAN and port belong at this VLAN have traffic input and output, but in the destination port, I always see it output traffic..
Global command
Red-127#sh run | in moni
monitor session 1 source vlan 1127
[Code].....
View 3 Replies
View Related
Jan 20, 2013
Our customer get the problem that the switch count the 5mins input/output rate of connected traffic interface always ZERO.The problem only occur in the module 3,4 and 5 interface, module 2 has no problems.
-------------------------------------------------------------------------------------------------
Catayst 4506E
12.2(52)SG
Chassis Type : WS-C4506-E
Power consumed by backplane : 0 Watts
Mod Ports Card Type Model Serial No.---+-----+--------------------------------------+------------------+-----------1 6 Sup 6-E 10GE (X2), 1000BaseX (SFP) WS-X45-SUP6-E 2 48 10/100/1000BaseT (RJ45) WS-X4548-GB-RJ45 3 48 10/100/1000BaseT (RJ45) WS-X4648-RJ45-E 4 48 10/100/1000BaseT (RJ45) WS-X4648-RJ45-E 5 48 10/100/1000BaseT (RJ45) WS-X4648-RJ45-E
[code]....+
View 2 Replies
View Related