Cisco WAN :: 6500 - Input / Output Drops
Feb 7, 2011
I have this topology in part of my networ:k
Cisco7200---Cisco6500---Cisco3560---LAN1
|
Cisco3560
|
LAN2
All devices are interconected via optical 1Gb/s links. There is no QoS implemented on any device and all VLANs are allowed on all interfaces.
Also all links are trunks (with many VLANs)
In LAN1 there was a layer 2 broadcast-storm and 4000packets/s was comming to rest of the network (in one particular VLAN).
1) 7200 with G1 should be able to handle traffic up to 500Mb/s, but a lot of users experienced drops on traffic via 7200.
(CPU load was around 10%).
2) Why do I have input drops on 7200 on link toward 6500 if CPU was normal. Broadcast comming to this interfaces were cca 4kpps. But since it's destination is not on router these packets should be rejected on interface controller. Is that right? (7200 doesn't even has dot1q subinterface in that VLAN but since 6500 allow all VLANs on its trunk these packets reach 7200)
3) Why do I have output drops on Cisco 6500 (it is here as layer 2 device only)? It is max 160Mb/s in output direction. It has WS6724 card with DFC (there is no oversubscription).. Shouln't 6500 send traffic as fast as interface allows (up to 1Gb/s). Am I righ't?
4) After all how coul'd 6500 now if 7200 can't handle these traffic?Output drops should be only seen if QoS is enabled (i.e. shaping), or if there is oversubscription on the linecard?
View 4 Replies
ADVERTISEMENT
May 11, 2011
My router, a Cisco 7204 with NPE 300, is experiencing output drops and input errors on a fastethernet interface. I have a 100Mbps connection with less than 15Mbps utilization at peak times.
FastEthernet1/0 is up, line protocol is up Hardware is DEC21140, address is 0014.a985.1a1c (bia 0014.a985.1a1c) Internet address is 38.102.66.134/30 MTU 1500 bytes, BW 100000 Kbit, DLY 100 usec, reliability 255/255, txload 3/255, rxload 1/255
[Code]....
View 17 Replies
View Related
Mar 18, 2012
I found increasing of total output drops and output queue drops even input rate was low and no qos apply on this interface. I plan to increase hold queue out for output queue.
Router 1941, 15.0(1)M4
Serial0/0/0 is up, line protocol is up
Hardware is WIC MBRD Serial
[Code]....
View 1 Replies
View Related
Jun 17, 2012
What does RP drops entail? We are experiencing 0.23 % drops on an vlan int on one of our 6500. This interface is an L3 to a server-subnet. Doing a sh int vlan 238 switching shows 30935411 RP (Route Processing) drops.It was a bit unclear to me in the thread "Input queue drops on 6500 vlan interface" if RP drops was through the router, or to the router(mgmnt)?I can do a netdr to see what traffic goes to it. It should not generate CPU load, but I think I will wait until after hours before I try that command.
- do NETDR:
-- debug netdr cap rx vlan 238
-- show netdr cap
View 5 Replies
View Related
Dec 6, 2011
Vlan interface would be dropping packets on the input queue? Refer to the drops/flushes below. This is from a 6500 with a Sup720, there are a number of vlans on it. This 6500 and it's HSRP partner are exhibiting the same symptoms on all the vlans I bothered to check. This particular vlan is quite lightly used, there are only about fifteen user PC's (each with 100 Mb interfaces) on it.
There is a bit of information on input queue drops on Cisco, but this is focused on physical interfaces where I can understand some packets being dropped. I would think that Vlan interfaces would have different issues.I note the "no buffer" errors as well, that also concerns me, especially as that counter is quite close to the "flushes".
Vlan123 is up, line protocol is up Hardware is EtherSVI, address is 00d0.04fd.6000 (bia 00d0.04fd.6000) Description: Vlan123 Internet address is 10.123.123.7/24 MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec, reliability 255/255, txload 1/255, rxload 1/255 Encapsulation ARPA, loopback not set Keepalive not supported ARP type: ARPA, ARP Timeout 04:00:00
[Code] .......
View 3 Replies
View Related
Sep 8, 2012
I can see drops on one of our busy L3 vlan in the input queue and are going up very frequently.System image file is "sup-bootflash:s72033-psv-mz.122-18.SXD3.binHardware = 6509
View 1 Replies
View Related
Nov 23, 2012
Have got 2 6500 in VSS. I'm seeing unsual high output drops. IOS Version: advipservicesk9-mz.151-1.SY.bin
Seeing too much output drops on interface ( in millions). When checked buffers ( output pasted below), it also shows enourmous drops.Not too sure, but is this normal or is there something fishy; which needs to be investigated. [code]
View 3 Replies
View Related
Mar 22, 2012
We have 7206 VXR running NPE-G1, we are looking for the GigE cards for 7200 which supports upto line rate and came across Cisco 7200 Series Input/Output Controllers The datasheet for the same doesnt say anything about line rates.
View 3 Replies
View Related
Jan 10, 2012
Sometimes our network lag and i thing there is a computer making this problem. i'd like to audit all input output of all port of a Catalyst 1900. all i manage to do is to enter to the console menu via Telnet.. once here, i try monitoring but i'm afraid to do a bad thing :
Catalyst 1900 - Main Menu
[C] Console Settings
[S] System
[N] Network Management
[P] Port Configuration
[Code]...
View 2 Replies
View Related
Nov 23, 2010
when i type "show interface" command on 1941 router, shows below print. Why 5 minute input-output rate are 0 bits? Can it be a bug?
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
304015 packets input, 151607798 bytes, 0 no buffer
[Code].....
View 11 Replies
View Related
Jun 7, 2012
I have a video feed coming into my 3570. It comes in at 5 minute input rate 18777000 bits/sec, 1695 packets/sec. However, the uplink to the router is much different, 5 minute output rate 130000 bits/sec, 28 packets/sec. I am in a lab and about ready to go into testing phase for a project when we discovered this problem, as this video feed is not veiwable on the other end.
Below is the config and capture from the switch.
BLOSSw1#sh int g1/0/6GigabitEthernet1/0/6 is up, line protocol is up (connected) Hardware is Gigabit Ethernet, address is a44c.112f.3506 (bia a44c.112f.3506) MTU 1500 bytes, BW 1000000 Kbit/sec, DLY 10 usec, reliability 255/255, txload 1/255, rxload 4/255 Encapsulation ARPA, loopback not set Keepalive not set Full-duplex, 1000Mb/s, link type is auto, media type is 10/100/1000BaseTX SFP input flow-control is off, output flow-control is unsupported ARP type: ARPA, ARP Timeout 04:00:00 Last input never, output 00:00:00, output hang never Last clearing of "show interface" counters 15:16:25 Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0 Queueing strategy: fifo Output queue: 0/40 (size/max) 5 minute
[code]....
View 2 Replies
View Related
Mar 6, 2013
On my SUP-7E, when I issue a " show interface vlan X " I cannot see the expected input/rate reflecting the real rate (which should be very high).
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 4000 bits/sec, 2 packets/sec
(Under the physical interfaces it is ok)However on other SUP-IV I can see the real rate.
My questions are :
- Why the SUP-7E does not reflect the rate, whereas the SUP-IV does ?
- I have heard about the 'counter' command under the vlan interface to activate the rate counters. Is this command application has any side effect on the switch ?
View 2 Replies
View Related
Jan 20, 2013
Our customer get the problem that the switch count the 5mins input/output rate of connected traffic interface always ZERO.The problem only occur in the module 3,4 and 5 interface, module 2 has no problems.
-------------------------------------------------------------------------------------------------
Catayst 4506E
12.2(52)SG
Chassis Type : WS-C4506-E
Power consumed by backplane : 0 Watts
Mod Ports Card Type Model Serial No.---+-----+--------------------------------------+------------------+-----------1 6 Sup 6-E 10GE (X2), 1000BaseX (SFP) WS-X45-SUP6-E 2 48 10/100/1000BaseT (RJ45) WS-X4548-GB-RJ45 3 48 10/100/1000BaseT (RJ45) WS-X4648-RJ45-E 4 48 10/100/1000BaseT (RJ45) WS-X4648-RJ45-E 5 48 10/100/1000BaseT (RJ45) WS-X4648-RJ45-E
[code]....+
View 2 Replies
View Related
Feb 25, 2013
I have a connection that is loosing packets, my show interface output below summarises the interface where i believe the problem is occuring. My Hardware is 6509 running 12.2
View 1 Replies
View Related
Mar 22, 2013
I have a 3750X-24T in our production environment that is showing very high number of OQD's in the 'show int sum' output for 4 of the Gigabit interfaces; the interfaces are each in a seperate port channel and there are no OQD's for the relevant port channel and there are no output drops showing in the output for the 'sh int' command for each interface.
The following are the OQD's for the relenvant interfaces
Gi1/1/1: 0
Gi1/1/2: 0
Gi1/1/3: 0
Gi1/1/4: 0
Gi2/1/1: 4252879251
Gi2/1/2: 4251090833
Gi2/1/3: 4251754140
Gi2/1/4: 4294942102
Po1: 0
Po2: 0
Po3: 0
P04: 0
Gi1/1/1 and Gi2/1/2 assigned to Po1, and so on.
IOS version: C3750E-IPBASEK9-M 12.2(58)SE2
View 1 Replies
View Related
Jan 31, 2012
I have an issue with an ASR 1001. The problem occurs with MQC shaping applied to a gigabit interface in the outbound direction. The CIR of the provider we are using is 100Mb/sec, so we are shaping to that value. However when reported traffic levels are about 60Mb/sec, we see a steady increase in output drops. [code]
I have also tried increasing the hold queue, however this does not work with the drops. Increasing the shaping rate to 200Mb/sec gets rid of almost all the drops (not quite all!) but is not what we need. I think that we should see some drops when rates spike above 100mb, however the amount we are seeing seems excessive?
View 1 Replies
View Related
Jan 4, 2011
We have a 7613 w/ WS-SUP720-3BXL running 12.2(18)SXF11. We have a 48 port WS-X6748-GE-TX that has one interface that keeps getting output drops for anything over 200Mb/sec.
See the attached file which has more details and show results.
View 1 Replies
View Related
May 14, 2012
I have cisco 887M-K9 router and I can see output drops are increasing on ATM interface. [code]
View 9 Replies
View Related
Jul 29, 2012
Why my OC3 interface is showing increasing output drops its starts happening as soon traffic exceed 60Mbps ( FYI my traffic never exceeded 75Mbps MAX, and circuit is 150Mbps from carrier , full OC3)
Below are few stats as starter. IOS i am using is c7200p-is-mz.122-31.SB10.bin
sh int pos1/1
POS1/1 is up, line protocol is up
Hardware is Packet over Sonet
[Code].....
View 17 Replies
View Related
Mar 2, 2011
I have some problems on my newly purchased wan routers Cisco 2921 with 15.1T3
on the wan interface is see "ouput drops" this is gigabit ethernet on both sides , but the ISP delivers 30mbit/s on this line.
ellslr1#sh int gig 0/2GigabitEthernet0/2 is up, line protocol is up Hardware is CN Gigabit Ethernet, address is 1cdf.0f26.beb2 (bia 1cdf.0f26.beb2) Description: *** WAN *** Internet address is x.x.x.x/x MTU 1500 bytes, BW 1000000 Kbit/sec, DLY 10 usec, reliability 255/255, txload 1/255, rxload 1/255 Encapsulation ARPA, loopback not set Keepalive set (10 sec) Full Duplex, 1Gbps, media type is RJ45 output flow-control is unsupported, input flow(code)
View 6 Replies
View Related
Sep 27, 2011
Am experiencing high output drops o int Gi 46,47,48 2950 int fa 22 23 and 24 are conneced to 3750 Gi 46,47,48 core sw1 3750 is connected to 2950 sw2 and vice versa
View 3 Replies
View Related
Sep 15, 2012
What are recommended commands to get input for network documentation (for disaster recovery)?
I've got 6500 with these modules: WS-SVC-FWM-1,
WS-SVC-IDSM-2, VS-S720-10G, WS-X6704-10GE, WS-X6748-SFP and dozens of WS-C3750E-48TD in couple of buildings.
So far I have these commands: Code...
View 3 Replies
View Related
Feb 10, 2012
I feel that 3560 and 3750 perform differently with the following two commands:
srr-queue bandwidth shape 5 0 0 0
srr-queue bandwidth limit 50
On 3750, the bandwidth for queue 1 is limited to 100mbps x 50% / 5 = 10mbps
On 3560, the bandwidth for queue 1 is limited to the smaller value of BW / shape weight and BW x limit%.
Does it sound about right? is there a way to check for mls qos input queue drops? The show mls qos interface xxx stat only shows the output queue drops. Maybe for some reason the input queue never drops?
View 6 Replies
View Related
Jul 4, 2011
I have a 48 port 2960 switch with 2 10/100 ports ( fa0/46-47) setup in an etherchannel with a 2950 48 port switch. I am getting total output drops on port fa0/47. [code]
View 2 Replies
View Related
May 10, 2012
I have an issue with input errors, overruns, and input reset drops on the inside interface of an 5580-40 (v8.2.5: Transparent mode) The box is not stressed at all according to the 'show' commands in the Cisco troubleshooting performance document for PIX/ASA v8.2.5. Nothing stands out because is pretty much normal, nothing (processes, RAM, blocks, IO...) really being highly utilized. I have replaced the 10Gig card and that seemed to work because the rate of errors has gone down tremedously. The next step is to RMA the whole box.My question is what would be the cause of the inside interface to stop processing traffic (I say that because the syslog server stops receiving messages) for some periods of 30 seconds periodically throughout the day and clients lose their connections (ie Outlook, IBM Sametime, Oracle, MSSQL..etc). Can the issue be somewhere related to the overruns and input errors?
View 2 Replies
View Related
Aug 2, 2010
I have quite a few 2960's in a manufacturing environment that are experiencing a large number of Total Output Drops. The gigabit uplinks arn't even close to fully subscribed and if I'm lucky they run at a peak of 4 - 5 Mb on a 1Gb uplink. Something really funky is going on. The individual switchports seem to have the total output drops and the uplinks at 1Gb do not have any output drops and never peak above 20Mb over a 3 month span on a 1Gb link.
View 25 Replies
View Related
Jan 30, 2012
MIB OID and the values.also i want to know the values og output packet and output packet drops MIB OID values of POS interface on GSR router (12000).because i am getting many output packet drops on these pos interface.how do i get these values from the router.
View 1 Replies
View Related
Oct 8, 2012
We are seeing some high output drops on our 3560G's and I'm wondering if there is anything I can do to solve this, or should I just be looking at an upgrade.I do not have qos enabled:
do-rs-ah-3560g#show mls qos
QoS is disabled
QoS ip packet dscp rewrite is enabled
I don't have anything special configured apart from some trunk ports, otherwise its mostly defaults.Should I enable qos and tweak the buffering?
View 9 Replies
View Related
Feb 21, 2012
I have a 3560X that is directly connected to an ASA 5505. I am seeing output drops on the 3560X interface that connects to the ASA. Below are the troubleshooting commands I have ran, but I don't see any indication to what is causing the problem.
3560X
show run int gig 0/24
!
interface GigabitEthernet0/24
[Code]....
View 1 Replies
View Related
Mar 13, 2012
I have too much output drops in my cisco 7206 VxR NPE G1 router. I'm doing dot1Q on this interface and is connected to switch , i changed the router and IOS but still the error is same . What can be the reason . The interface on switch and router are 1000/Full and i changed the cable also . The traffic only comes about max70Mbps and it is really confusing. [code]
View 9 Replies
View Related
Nov 6, 2011
i have an 2921 connected to an Catalyst 3560. My router interface shows quite a lot of input queue drops. Load is not too much max 5/255.
View 1 Replies
View Related
Nov 29, 2011
I have 2 Cat-6506's that are used for my WiSM's. The only thing in both Chassis is 2 X WiSMs a SUP-7203A and a 6516A line card.The only connection between the rest of the network and these chassis is on port gig 1/2.[code] If I have read other posts correctly all points to the ASIC being overun by that traffic being sent from my WiSMs out to the Network.
View 1 Replies
View Related
Jan 25, 2013
I've got a recurring them developing across several deployments of Catalyst 3750X series switches, I'm seeing large amount of output drops across multiple ports but there are is no QoS deployed on any of these switches. (standard FiFO). As it happens the ports in question are a member of EtherChannel groups which are connected to ESX Hosts.I've also seen this behaviour also unexplained on another 3750X at a different site, however it's a single port and connects to an Upstream firewall.However in both cases neither switch has any QoS or non-standard configuration, literally a couple of VLAN's and some EtherChannel groups.Here's some output from the case involving the ESX servers.
View 5 Replies
View Related