Cisco :: SG500-52P-K9-V01 Switch SNMP Port Control
Mar 13, 2013
I'm trying to disable/enable ports via snmp v2 on a Cisco SG500-52P-K9-V01 switch. The communties are setup properly and I even have successful snmpset commands which when queried display that the action was complete. The issue is that when I disable the port via snmp the device on that port does not drop offline. This is a PoE port with a device powered over PoE so I'd expect the port to disable but also the PoE to turn the device off - neither happens.
Any experience with port management on this device? I also noticed the interface IDs (for port 1 for discussion) are 1, 101, 201 etc. I've tried setting on 1 and 101 only but the results have been the same and what were mentioned above.
View 1 Replies
ADVERTISEMENT
Aug 26, 2012
Is there a way to ask the above switch how much power it's supplying to various ports?I've found some stuff in POWER-ETHERNET-MIB, but it's only the main power supply and the up/down status of the various ports.
It looks like what I want is
[URL]
but my SG500 tells me:
snmpwalk -v2c -cpublic serverswitch 1.3.6.1.4.1.9.9.402
CISCO-SMI::ciscoMgmt.402 = No Such Object available on this agent at this OID
View 6 Replies
View Related
Dec 18, 2011
i want use CACTI for monitor my bandwidth so i have a question how can i enable snmp for a switch port ? or i shoudl just enable snmp from configuratiopn terminal and then in CACTI i will choose which port will be monitor? can i do something that CACTI connect to my switch with a encryption key ? i have cisco 2960 48 port switch
View 2 Replies
View Related
Jan 31, 2013
how can i view the port G27 and G28 in GUI? As based on the GUI Adminstrator - > Port Management - > Port Setting i only can view from port G1 to G26. Or it will only appear when the port is active for stacking.
View 3 Replies
View Related
Jan 15, 2013
I have 3 x SG500-52P switches stacked. Vlan 1 is data and Vlan 3 is voice Port to Vlan membership is 1UP and 3T Port security is disabled
The issue I have is that I can have either a phone or a PC plugged into a port but not both. If I plug in both then the phone works and the PC gets an IP address (Broadcast traffic) but PC cannot browse the network.
View 9 Replies
View Related
Jun 5, 2013
I have the new firmware running on my SG500 switch. I've also just finished creating my VLANs. My issue is that I can't delete the old default VLAN .... VLAN 1. More importantly, I can't seem to get DNS to work on the switch.
When I set a DNS server, the VLAN defaults to VLAN 1, and the option is greyed out and can't be changed. Why is it VLAN1? Why is it greyed out? How do I get DNS to work on the switch, for services like Time Servers?
View 7 Replies
View Related
Feb 26, 2013
At our office we have a weird performance problem with the following switches and connectivity:
Internet |
SG300-24 (L3) core switch (in our server room)
|SG300-10P (L2) access swtich (in our meeting room) |
SG500-28P (L3) switch (in our meeting room)
We are building a new computer infrastructure that is connected to the the SG500-28P. As you can see above the SG500-28P in our meeting room has an uplink to the SG300-10P in the same meeting room. And again the SG300-10P has and uplink to the SG300-24 in our server room. From the server room, there is connectivity to internet. The network uses a multiple VLAN's and routeing between them. Bootom line is, the internet VLAN ID 10 is tagged to trunk ports and available on the SG500-28P. So client get connected straight into the internet based VLAN.
The performance on the SG500-28P switch itself from VLAN to VLAN is very fast. But... the uplink connection tot the internet and other VLAN's on the core switch are very and very slow! At least 10 times slower than normal. So if I plug a laptop in the SG500-28P and go from uplink to uplink, it is slow! But... when I connect the same laptop to the SG300-10P the connection with only one uplink it is fast. As if three switches is to much. I can't figure out why.
View 2 Replies
View Related
Feb 3, 2013
I have a brand new SG500-28P sitting on my desk.
The swtich is configured and going to operate in L3 mode. All ports are still assigned to the default VLAN ID 1. I have created several new VLAN's. Once I configure and aplly an IP Interface to a certain VLAN the swtich becomes inaccessable right away. I am pretty sure I am not pulling my own VLAN under my connection. Every port is inaccessable. I have to pull the power plug and restart the swtich with its saved configuration. Even when I add another IP interface to the default VLAN 1, same issue. I have tried lot's of things, but can't get it to work properly. I have just upgraded to the latest firmware.
I have configured dozens of SG300 swtiches which is very easy. This one does not work with me.
View 2 Replies
View Related
Feb 18, 2013
I have a SG500-28-K9-G5 at work and I'm tyring to connect to it trough the console port via Putty and get wierd symbols: When I press any button I see alot of wierd symbols comming up, for example if I press shift+6 or Enter (or anything). [code]
View 2 Replies
View Related
Jan 4, 2013
I have an SG-200-8 which connects to a stacked pair of SG500-28P switches. It is powered by PoE from the SG500. From the SG500 the port appears Up, but at the the SG200 it is disabled and nothing I do re-enables it. I know the cable is good because I had a previous netgear switch hanging off it and working, also the power gets through.I can only connect to the switch if I disable wifi and plugin a manually configured PC - DHCP doesn't get through to it from the SG500 end.I have tried a second SG200 same problem. Have disabled RSTP/ STP thinking it might to relate to the fact that a PC connected to the switch also had a wifi connection to the same LAN, but. Don't know where to go next. looks like a bug?
View 1 Replies
View Related
Apr 16, 2011
What are the SNMP port descriptions relate to on the SRP527? There is nothing in the administration guide and some of the ones that appear up don't make sense.
I think I have worked out a few by elimination but I wanted to confirm a few ...
View 6 Replies
View Related
Jan 30, 2012
Is there a way to send an SNMP trap form the ASA when port 80 is trying to be accessed??
We use the ASA5510 and also use ScanSafe Web Security. Web Security is great but we find ourselves worrying if user has edited their Browser connection settings to remove the proxy settings that we push down using Group Policy. We also cut off the users ability to make changes to those settings but it interferes when I need to troubleshoot a special program that cant use a proxy server. It just makes it harder for me. The other thing is that Group Policy only works for IE. Google Chrome will inherit the system settings in IE. So we have Safari and Firefox as well as a lot of others to worry about not getting the configuration. There is also debate about limitting the use of anything but IE and FireFox.
Without laying down the law and getting all sorts of hate mail and death threats I would like to run ScanSafe in such a way as to make sure each user receives the Group Policy settings and that is all.
I would now like to just set up an SNMP trap on the ASA for ANY traffic that is trying to get to port 80. Either get in in my syslog server or have the asa email me directly. Scansafe sends the Internet traffic out on 8080 to the Proxy towers.
I could block port 80 outbound but again, I limit my ability to troubleshoot on the fly. I would have to break this every time I need to troubleshoot.
View 1 Replies
View Related
Nov 16, 2011
I am in the process of setting up an interop lab for some engineers. The enviornment will consist of some 3750's, H3C's and ProCurves. My concern is that the end user will have Priv-Exec access for CLI usage on the 3750's and they can change the "en" password (I hope they don't but it has happened).Is there a way I can "break in" during the boot process to reset the password? The reason I am doing it this way is because I have an Altiris server with rebuild automation scripts in xpect and I would like to automate the process so I do not have to use a manual factory default reset.
View 5 Replies
View Related
Nov 21, 2011
I have configured SPAN session on 2960 switch, source port being a VLAN and destination being one of the fastethernet ports. All I see in the capture is control traffic (HSRP, RIP, Syslog, DNS..etc). However I dont see any real data traffic being captured. Below is how I have SPAN configured..
monitor session 1 source vlan <vlan_id> both
monitor session 1 destination interface fa0/42
View 1 Replies
View Related
Oct 30, 2012
I have 2 ME3600Xs and utilize Broadcast and Multicast storm control on client facing interfaces. One of my ME3600s is reporting a Multicast storm and that a packet filter action has been applied. The strange thing is that it is showing up on an Admin Down interface that has nothing connected to it. [code]
View 2 Replies
View Related
Aug 29, 2012
There is nice c2900PortNumberOfLearnedAddresses table in C2900-MIB, but it's outdated and not supported by modern switches.Is there similar table for modern switches? Most interested in Catalyst 2960 and 3750.
View 2 Replies
View Related
Sep 3, 2012
I am trying to setup SNMP v3 on a 4948E switch here is what I have done so far:
snmp-server location "location"
snmp-server contact IT Admins
snmp-server group SNMPgrp v3 priv read SNMP-ro write SNMP-rw access 80
snmp-server user snmp_user SNMPgrp v3 auth sha xxxxxxxxx priv aes 128 xxxxxxxx access 80
What else am I missing and how can I confirm that it is configured correctly?
View 2 Replies
View Related
Feb 1, 2013
I have been reading the postings on this site trying to retrieve the MAC address for the client devices (computers, printers) attached to our switches. We have approximately 500 switches and I need to map the mac address to the switch. It appears the OID information is for SNMP v2. We are restricted to using only SNMP v3. I have tried using the Cisco SNMP Object Navigator without any success.
View 2 Replies
View Related
Sep 4, 2011
Any snmpset commands to modify port vlan membership on SG300-28 switches? I checked [URL] however this information is apparently only valid for catalysts.
The latest firmware is installed and the provided MIB files are used.
View 5 Replies
View Related
Jan 19, 2011
Cisco Catalyst 2960 series,i want do a SNMP request over OID. When the output should be like this: Portnumber and VlanID. Is there a OID for this output?
View 1 Replies
View Related
May 24, 2013
I've got an SG300-10 connected back to back (trunked) with a Cisco 3560X switch, across a fibre link and am seeing some big inconsistencies in terms of unicast data transferred across the ports between them.
During a night time window of 4am - 6am I run backups which involves a large copy of files, that almost saturates a GigE link - we can see from the 3560X end that the link is running at a bit over 800MBit/sec of throughput, sustained. The duration of this transfer is consistent with the size of the files being transferred (ie just over an hour, and is what I'd expect for a data transfer of about that amount). Back-of-the-envelope calculations indicate that the 3560X is measuring this data throughput correctly.
However on the SG300 end of the link, which is also being polled by the same application (Cacti), I'm observing spikey counts of only around 20MBit/sec during that window. These counters are very obviously incorrect - there's a huge amount more data moving across the port than that. The incorrect calculations are showing on both the trunk port out of the SG300 (uplink) as well as the interface where the NAS is connected in (which is an access port).
Cacti is polling the OID: .1.3.6.1.2.1.2.2.1.16.57 which translates to IF-MIB::ifOutOctets.57 = Counter32.I'm running version 1.3.0.62 but this problem is not new to this release - previous releases and 1.2 based releases also had this problem.
It looks like multicast traffic may be being counted correctly (that's only a suspicion though), however what I am certain of is that there is a very large discrepancy with the unicast traffic counts.Is this OID the correct one to be using for this switch?
View 2 Replies
View Related
Sep 25, 2012
My Network Layout is as, Firewall (with Routing)------>Cisco 3560 Switch (L3)------> connected 8 Cisco 2960 switch (L2)----> all users I have configured 20 VLAN's on cisco 3560 switch with Dynamic Pool and Static, Means, 5 Vlan's are Dynamic and remaining are Static Our Company process provides only internet access to existing clients computers. Problem is that, I configured Static VLAN 5 for one of our Client in their seperate room, mean to say, i activated all ports of their room with Static VLAN 5. one day they configured own DHCP server on Windows 2003 Server with same subnet (Same as VLAN5) in their room without any information and now their all computer/ Laptop acquiring ip address Dynamically.
If i have configured Static vlan on that port's then how it is get Dynamic ip from same port's.How to restrict to permit another DHCP server/Service in our premises. I Do not want to give administrative control to Clients to do such kind of thing with LAN.
View 8 Replies
View Related
Sep 18, 2012
WS-C2960G-24TC-L 12.2(25)SEE3 C2960-LANBASE-M
I would like to get the temperature status from this 2960 switch (and several other models. Normally this OID should be:.1.3.6.1.4.1.9.9.13.1.3.1.6 But it does not return anything.
The termperature status can be found from the command line by running:"sh env temp" This reports back ok, so I assume there is a temperate gauge in the switch.
This oid is part of the "CISCO-ENVMON-MIB" mib and accouding to the Cisco MIB selector it is supported on my switch and IOS - 12.2(25).
(Another thing I woudl like to monitor and should be supported is the fan status oid (.1.3.6.1.4.1.9.9.13.1.4.1.3). That doesn't return anything either.
What do I need to do to get the temperature environment status from SNMP query?
View 3 Replies
View Related
Mar 28, 2012
I have a Catalyst Switch 6000. Inoticed that after the execution of the job inventory in LMS, and after the snmp queries reached the equipement, the cpu value reached 98-99 % due to the process : PDU DISPATCHER (what’s it ?)
I have also a script running in the switch to observe the differents logs. For exemple, when high cpu is obtained, the message bellow appear :
« %SNMP-3-INPUT_QFULL_ERR: Packet dropped due to input
« %SNMP-3-INPUT_QFULL_ERR: Packet dropped due to input
« %SNMP-3-INPUT_QFULL_ERR: Packet dropped due to input
....
View 1 Replies
View Related
Jan 11, 2013
I have just switched from an e3000 to ea6500 and all iPhone / iPad / PC control via port forwarding is lost.
View 3 Replies
View Related
Dec 2, 2012
I'm developing a project where I use the SNMP protocol to discover the network. By discovering the network I mean go through all the routers and switches and retrieve the IP routing table from routers and the forwarding table from switches. With the routers I have no problem. For the switches I need to know for each port the MAC addresses and the Vlans. Basically it's use SNMP to find a port number from a MAC address. To do that i followed this tutorial: [URL]
The problem is that I'm using a Cisco 3725 Router with IOS 12.4 (21) and a NM-16ESW module to work as a Switch and when I use the OID .1.3.6.1.2.1.17 corresponding to the BRIDGE-MIB as it follows:
snmpwalk -v2c -c myrouter 10.1.1.5 .1.3.6.1.2.1.17
it returns:
SNMPv2-SMI::mib-2.17.1.1.0 = Hex-STRING: 00 00 00 00 00 00
SNMPv2-SMI::mib-2.17.1.2.0 = INTEGER: 0
SNMPv2-SMI::mib-2.17.1.3.0 = INTEGER: 4
From this I guess there's no information on the router about Vlans or anything. Other thing is that when I use community string indexing it returns a timeout. My theory is that this version doesn't support indexing but I don't know.
how can I get the Port Number from a MAC address from this "switch" (it's a router working as a switch) using SNMP?
View 2 Replies
View Related
Aug 8, 2012
I am having a lab switch. Recently I am getting "%SCHED-3-SEMLOCKED: SNMP ENGINE attempted to lock a semaphore, already locked by itself" message and the switch has started to hang a little bit. I just want to know what this log means and how to trouble shoot.
I'm using C3750, version 12.2(25)SEE3
View 8 Replies
View Related
Jun 11, 2011
I try to configure in both Clean Access Manager and Switch 3560E-24Ps on SNMP Version 2 protocol but I can't make it working together (For CAM and Switch 3560G-48Ps I can do that). [code]
View 3 Replies
View Related
May 8, 2012
On the supervisor card of a cisco 6500 series, according to the following link, [URL] it only has 2 uplink ports on the card. Would I be correct in assuming that I only have those to ports that I can configure IP addresses on?
The cisco that is being devlivere is coming with a 48 port switch and 24 port fibre switch. Could I change any of those ports into a router port and configure IP addresses on those?
The supervisor card is a ws-sup-720-3b the 48 port switch is a ws-x6748-ge-tx the 24 port fibre switch is ws-x6724-sfp
View 3 Replies
View Related
Jun 5, 2013
I'm fairly new to Cisco products am in the process of developing my network knowledge on a deeper level. I have a 3825 with a HWIC-4ESW and I'm struggling to fully understand how the two "see" each other. I've setup a V LAN with a layer 3 address on the HWIC and added the switch ports to it. This seemed to allow devices connected to the switch ports to talk to the built-in router ports. I thought this was all making sense until i applied an access-list to the router port. It's a simple ACL i'm just using for testing and the only thing it does is blocks telnet from anywhere. I know the ACL is setup properly because if I connect a device directly to the router port i cannot telnet to the port. However, if i connect a device to one of the switch ports, i am able to telnet to the router port successfully.
It seems that I'm missing something with how traffic flows from the switch port to the router ports and how the two "see" each other.
View 2 Replies
View Related
Dec 28, 2008
what is the use of no switch port command in L3 switch?
View 7 Replies
View Related
Feb 26, 2012
I was looking for a way to connect an AUX port from a 1700 router to a 6500 switch module console port, to see the output of the Switch's on the 1700 router, in case there is a network downtime, I could see what's going on in the switch, what cable should I use ? Also, is there is any kind of documentation for this type of config what have I seen is very few info.
View 2 Replies
View Related
Jan 16, 2011
is it possible to assign a loopback address to a typical switch port on a 2950 switch? I want to be able to have some devices connected to a switch to test access lists and VLANs.
View 3 Replies
View Related