Cisco Infrastructure :: Temperature Status From 2960 Switch Using SNMP Not Working
Sep 18, 2012
WS-C2960G-24TC-L 12.2(25)SEE3 C2960-LANBASE-M
I would like to get the temperature status from this 2960 switch (and several other models. Normally this OID should be:.1.3.6.1.4.1.9.9.13.1.3.1.6 But it does not return anything.
The termperature status can be found from the command line by running:"sh env temp" This reports back ok, so I assume there is a temperate gauge in the switch.
This oid is part of the "CISCO-ENVMON-MIB" mib and accouding to the Cisco MIB selector it is supported on my switch and IOS - 12.2(25).
(Another thing I woudl like to monitor and should be supported is the fan status oid (.1.3.6.1.4.1.9.9.13.1.4.1.3). That doesn't return anything either.
What do I need to do to get the temperature environment status from SNMP query?
View 3 Replies
ADVERTISEMENT
Jan 24, 2012
I need the temperature oid for cisco 1841 and 2960 switch.
View 1 Replies
View Related
Aug 15, 2012
May I know how to monitor temperature status of below device by SNMP.How to find the exact oid of those devices? I can only find the mib file of Nexus 5000 at url...Cisco Nexus 5010PCisco UCS 6120XP Cisco ASR 1002F
View 1 Replies
View Related
Dec 18, 2011
i want use CACTI for monitor my bandwidth so i have a question how can i enable snmp for a switch port ? or i shoudl just enable snmp from configuratiopn terminal and then in CACTI i will choose which port will be monitor? can i do something that CACTI connect to my switch with a encryption key ? i have cisco 2960 48 port switch
View 2 Replies
View Related
Jul 28, 2011
i have 3560 switch located in warehouse environments . i need to monitor the temperate of this switch . i am looking for OID value that serves this purpose .
kindly provide me how to look for all OID that give me real time status for FAN .. CPU UTILIZATION ...TEMPERATURE ...OR ANY MAJOR EVENT THAT CAN DISRUPT MY PRODUCT IN .
View 3 Replies
View Related
Jun 19, 2012
Is temperature monitoring via snmp supported on Cisco 2801 routers? when i perform a snmpwalk i donot get the associated value for the oids.
View 2 Replies
View Related
Dec 21, 2011
I have load CISCO-ENVMON-MIB and initiate walk in it but unable to find OID of Cisco 2960 temperature monitor. I have search over net and found .1.3.6.1.4.1.9.9.13.1.3.1.3.1 for temperature but this OID is not responding in this mib.
View 2 Replies
View Related
Feb 24, 2013
requesting information via SNMP from my two stacked C3750X, running IOS 12.2(55)RE5. The stack is up and running and everything is just fine. There are three PowerSupplies installed with a PowerStack, also running like expectet.My problem ist to get the status-information about the chassis-fans. I couldn't find any information about the OID and the search results only in some non-useful information about the MIBs from Cisco which delivers only three information about installed fans (and fan-containers), so I guess these are the information about the fans included within the powersupply?! The chassis-fans are installed and the LEDs are green for all four fan-mounts, up and running.
View 4 Replies
View Related
Mar 27, 2012
on the followup the document "Configuration example : central web-authentication with a switch and Identity Service Engine" by Nicolas Darchis, since the redirection on the switch is not working.
I'm using ISE Version : 1.0.4.573 and WS-C2960-24PC-L w/software 12.2(55)SE1 and image C2960-LANBASEK9-M for the access.
The interface configuration looks like this:
interface FastEthernet0/24
switchport access vlan 6
switchport mode access
switchport voice vlan 20
ip access-group webauth in(code)
View 12 Replies
View Related
Jan 16, 2012
I need to implement a "Spanning Tree Status" view on my NMS and I would like to use SNMP. I'm running Rapid Per-VLAN Spanning Tree Protocol on 3560-E (WS-C3560E-24TD) with IOS 12.2(55)SE.Using the ciscoStpExtensionsMIB MIB (CISCO-STP-EXTENSIONS-MIB) I see the stpxRSTPPortRoleTable table, which contains the stpxRSTPPortRoleValue value, and I think it could be fine for my job.The problem is that this table uses an index based on the standard dot1dBridge.1.4 table (dot1dBasePortTable) that does not report some interfaces: [code]I think the dot1dBasePortTable does not include those interfaces (5, 7, 8) where I do not run standard STP, but I need the dot1dBasePortEntry entries because I have to use them in order to get the interface ID (values like 10109, 10110, 10111).
View 0 Replies
View Related
Sep 26, 2011
what is the OID for See the hit status of the spefic VIP and RIP coming under the VIP .apeart from this CSS box having any module to moniter the hit status or VIP's and RIP's
View 2 Replies
View Related
Mar 9, 2013
why getting temperature event in 3560 switch, and we checked the Network room Temp it's normal around (22).
View 8 Replies
View Related
Feb 26, 2012
I am trying to get the temperature reading from one of our 3560G Switches using SNMP. When I run an snmpget on the Switch it returns back to me a "1".
So when I run the following I get:
> snmpget -v1 -c public 192.168.x.xxx 1.3.6.1.4.1.9.9.13.1.3.1.3.1005
SNMPv2-SMI::enterprises.9.9.13.1.3.1.3.1005 = Gauge32: 1
But when I telnet to the device and run a "show env temperature status" I get:
# show env temp status
Temperature Value: 32 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 51 Degree Celsius
Red Threshold : 61 Degree Celsius
So I'm not sure why I am getting a "1" when using snmpget on the OID 1.3.6.1.4.1.9.9.13.1.3.1.3.1005 which is (ciscoEnvMonTemperatureStatusValue)??
If I run the same OID on another 3560G Router I get the correct output from snmp....
View 4 Replies
View Related
Jun 20, 2012
I use a cisco 2620 voice gateway with a module NM-HDV-2E1-60. Tell me how you look at snmp for Cisco 2620 load E1. For 2811, I found oid 1.3.6.1.4.1.9.10.19.1.1.4
View 4 Replies
View Related
Jan 20, 2013
I have problems with setting the snmp retry / timeout parameters for our devices. I managed to import our devices with bulk import , but after it I realized that for some devices the snmp retry / timeout values were different ( created the bulk file with 3 retries and 30 sec timeout , but in the system the appear with 2 retries and 1 sec timeout). I tried to change it manually , but after a while it goes back to the wrong values.
View 1 Replies
View Related
May 21, 2013
I have a Cisco SG 300-20 as the core switch, layer 3. It is 192.168.4.6 on VLAN1 and 192.168.5.1 for VLAN2 (VOIP). All the ports are set in trunk mode. DHCP relay is setup on this switch.
The phones connected into a layer 2, Catalyst 2960-S switch. All ports are set in trunk mode. Default gateway on it is set to 192.168.5.1.
DHCP for both VLANs is provided by a Windows Server 2008 R2 server (the relay IP 192.168.4.15).
There is also an ASA 5510 in the mix which is 192.168.4.1. It has a route added to it for the 192.168.5.0 network to go to the SG 300 (192.168.5.1).
Just the two switches can ping each other on the 192.168.5.x network when I "add vlan 2" to the trunk port that is connected between the SG 300 and the 2960. The phones don't get DHCP on the 2960 switch. And I cannot ping 192.168.5.x from the ASA or anything else on the 192.168.4.x network.
After a bit of reading on intra-vlan routing for the SG 300 switch, I am thinking the SG 300 has to be the "center" of things so I need to make it 192.168.4.1 to be the gateway for both VLANs and change the ASA to 192.168.4.2 for VLAN1, etc. And I really can't do asymmetric routing with this switch.
View 1 Replies
View Related
Apr 6, 2013
we have two 6509E which are configured in VSS mode with the following modules in each:
1 48 CEF720 48 port 10/100/1000mb Ethernet
2 8 DCEF2T 8 port 10GE
3 4 CEF720 4 port 10-Gigabit Ethernet
5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G
I need to know if the temperature of the attached modules are normal or there is a problem?
the status of one of the supervisor engines is "MajFail" as shown below:
Mod Online Diag Status
---- -------------------
1 Pass
2 Pass
3 Pass
5 Major Error
View 3 Replies
View Related
Dec 12, 2011
What is the correct way to create an SNMP user on a Nexus 5k Switches and limit the read/write access to some OIDs?I have been searching for hours for configuration examples or guides, but i had no luck.I guess a role has to be created, containing rules for some feature, but the list of features doesn't contain anything about snmp.This is my configuration on catalyst switches and i'd like to achieve the same result on the Nexus 5k:
conf term
access-list 10 permit host x.x.x.x
access-list 10 deny any
snmp-server view myview ccCopyTable included
snmp-server group mygroup v3 priv read myview write myview access 10
snmp-server user myuser mygroup v3 auth md5 xxxxxx priv aes 256 xxxxxx
end
View 1 Replies
View Related
Dec 10, 2012
I would like to be able to query the dot1dStpPortState obect on the Catalyst 2960-S on our LAN . Im running firmware c2960s-universalk9-mz.122-55.SE2.bin and according to the Cisco SNMP Object Navigator the object is supported (via the BRIDGE-MIB).However when i query using snmpwalk from my workstation :snmpwalk -v 2c -c bic-zua-ro 10.u.y.x 1.3.6.1.2.1.17.2.15.1.3 I receive and error .SNMPv2-SMI::mib-2.17.2.15.1.3 = No Such Instance currently exists at this OID For the sake of comparison, querying our 4700 :snmpwalk -v 2c -c bic-zua-ro 10.u.y.x 1.3.6.1.2.1.17.2.15.1.3 returns (as expected, cropped)
SNMPv2-SMI::mib-2.17.2.15.1.3.1 = INTEGER: 5
SNMPv2-SMI::mib-2.17.2.15.1.3.3 = INTEGER: 5
SNMPv2-SMI::mib-2.17.2.15.1.3.40 = INTEGER: 5
SNMPv2-SMI::mib-2.17.2.15.1.3.67 = INTEGER: 5
SNMPv2-SMI::mib-2.17.2.15.1.3.104 = INTEGER: 5
SNMPv2-SMI::mib-2.17.2.15.1.3.257 = INTEGER: 5
SNMPv2-SMI::mib-2.17.2.15.1.3.258 = INTEGER: 5
SNMPv2-SMI::mib-2.17.2.15.1.3.259 = INTEGER: 5
Is there some special configuration i need to do on our 2960's. The only snmp related settings i can see in the running config is snmp-server community. In this case :
snmp-server community bic-zua-ro RO
View 3 Replies
View Related
Mar 2, 2012
I have NM-AIR-WLC6-K9 in Cisco 2821. Is there opprotunity to retreive configuration via SNMP as from Cisco Catalyst 2960?
View 1 Replies
View Related
Jan 19, 2011
Cisco Catalyst 2960 series,i want do a SNMP request over OID. When the output should be like this: Portnumber and VlanID. Is there a OID for this output?
View 1 Replies
View Related
Jul 10, 2012
I would like to test the possibility to reload devices via SNMP for new switches like 2960, 3560 and so on.I know that the command "snmp-server system-shutdown" has to be configured, then I need to send the set query to the device via SNMP.
I have found on the net the OID 1.3.6.1.4.1.9.2.9.9.0 but it belongs to an old MIB and doesn't seem to work with new switch models.
View 4 Replies
View Related
Sep 10, 2012
I have Cisco 2960's, 3750's and 3750x's all running IOS on the access layer. I have Cisco 6504's running IOS on the Distribution and Core layers. I am looking to monitor redundant links through Spectrum by having specific ports send traps but I have run into trouble finding how to configure it. I would like to have:
1. Logging enabled for all links (Fiber and Copper) so that I see all links up/down messages in the syslog
2. SNMP traps sent for linkup/link down messages only for redundant links (ex. Dual Up links from Access Layer or Redundant Ether channel Links on Dist Layer)
3. SNMP traps should be ignored/not sent for all copper ports.
View 3 Replies
View Related
Mar 6, 2012
I am using Cisco 2960 access switches and dont have NTP server so i can manually set time on switches but problem raised when these switches restart they show their factory default time.
View 2 Replies
View Related
Jul 28, 2011
I have the following configurations for switch to switch connectivety. sh int sh config int
2960 will not take full duplex setting.
Core switch
WS-C4506 cat4000-i9s-mz.122-25.EWA10.bin
FastEthernet5/8 is up, line protocol is up (connected)
[Cdoe]....
View 2 Replies
View Related
Dec 17, 2012
i have few catalyst switches (2960, 3750) and i can't upload to them any files by tftp from my laptop, but i can download from them, and this bug don't appears on two routers.I was change tftp server, type of connection (wifi, cable), turn off firewall on win7, but no dice.
View 2 Replies
View Related
Jan 14, 2013
I'm running PI 1.2.1.012 and I'm having issues populating client information. Most of my switches are 2960 series. Specifically I get a lot of MAC Address "Unknown" and nothing in the IP address field. I probably get about 25% of the correct MAC address and 10% of the IP addresses. I also run CiscoWorks Prime LMS 4.3.2. and the user tracking information is about 98% correct pertaining to MAC address and IP address. My other network management tools also are very accurate.
View 1 Replies
View Related
Oct 26, 2011
We recently installed two 2960, both of them with this fw version:
Cisco IOS Software, C2960S Software (C2960S-UNIVERSALK9-M), Version 12.2(55)SE3, RELEASE SOFTWARE (fc1)
The switches see very few traffic (under 40MB on all interfaces, summed, so far), however, I/O memory utilization is about 80% as can be seen from the show memory command:
Head Total(b) Used(b) Free(b) Lowest(b) Largest(b)
Processor 2B89A18 73969000 27198964 46770036 45060368 29367536
I/O 6200000 14680064 12185292 2494772 2323116 2380896
Driver te 1A00000 1048576 44 1048532 1048532 1048532
The memory allocated is almost all Packet Data, by init, "sho memory io dead" returns zero, the memory usage seems constant, there are no errors on the log, the switches operate correctly, no packet has ever been dropped, CPU usage is about 4%.
Here I showed info for one switch, the other is in the same situation. I just want to know if this behavior is expected, I don't want to find out problems when the switches will be in production whit real traffic.
View 5 Replies
View Related
Apr 9, 2013
I just got PI1.3, I'm new with it, and I don't know how to add devices. I have an 4500-X, an 3850 and 12 pcs. 2960S.
I see that are some out-of-the-box templates, but when i try to deploy, for example "medianet perfom" in Devices box I got "no data available"
What I have to configure on switches?
View 2 Replies
View Related
Sep 12, 2011
How I can prioritize Web Ex, Skype and some two websites on Cisco equipment. My set up is such that my 512kbps link goes to a Cisco 1941 router>Cisco ASA 5505>Cisco Catalyst Switch 2960>Computer.I want to be able to prioritize this on my network and test that it actually works.
View 1 Replies
View Related
Dec 12, 2011
I have recently installed 4 3560 (WS-C3560X-48T-S) Switches. At first the switch comes up, indicating all connected ports with a green LED. Whenever i unplug a cable and plug it back in, the status LED will stay off. The same thing happens when I push the mode button and cycle throgh the different modes, i lose certain LEDs.
I'm using 12.2(53)SE2, another user reported the same issues under 12.2(55)SE1 .
View 4 Replies
View Related
Feb 27, 2013
I have ASA running version 8.2.5 and using snmp v3 as below;
snmp-server group Authentication&Encryption v3 priv
snmp-server user SNMP_TEST Authentication&Encryption v3 encrypted auth md5 cisco123 priv aes 128 password123
snmp-server host IN 10.10.10.110 version 3 SNMP_TEST
LMS device credential is as per above SNMPv3 config.Can't get this to work. Digging aroung but no avail. I also try this on ASA 9.1 but same result.
View 4 Replies
View Related
Jul 30, 2012
My network is currently running with SNMP v2 configured in easch devices. With snmp v2 our LMS 3.2 server is working fine. However we have planned to migrate our network to snmp v3 . I have configured my few devices for SNMP v3 and added them to my LMS server.
Except DFM module these new SNMP v3 devices are working fine in all other modules. In DFM these devices are reflecting under "snmp timeout" group. I checked with device center -> management station to device; where the SNMP v3 connections are showing "okey"
following are tyhe configuration i have done in my devices.
snmp-server group v3g v3 priv read testr write testw
snmp-server user v3u v3g v3 auth md5 test123
snmp-server view testr iso in
[Code].....
View 2 Replies