Cisco Switching/Routing :: Modules Operating Temperature And Major Error On 6509E Switch

Apr 6, 2013

we have two 6509E which are configured in VSS mode with the following modules in each:
 
  1   48  CEF720 48 port 10/100/1000mb Ethernet 
  2    8  DCEF2T 8 port 10GE                    
  3    4  CEF720 4 port 10-Gigabit Ethernet    
  5    5  Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G  
 
 I need to know if the temperature of the attached modules are normal or there is a problem?

the status of one of the supervisor engines is "MajFail" as shown below:
 
Mod  Online Diag Status
---- -------------------
  1  Pass
  2  Pass
  3  Pass
  5  Major Error

View 3 Replies


ADVERTISEMENT

Cisco Switching/Routing :: SG200-08 - Operating Of Switch With Outer Case Removed

May 23, 2013

I am going to be putting an SG200-08 (8 port switch) inside a 2U rack mount chassis. To enhance cooling I thought I would remove the outer case. Are there, or would there be any issues with using the switch with the cover removed?

View 2 Replies View Related

Cisco Switching/Routing :: Total Output Drops On Switch Port On 6509E

May 22, 2012

What is the cause of having a huge number ( 875349) of total output drops on one of my gigabit utp port  gi 2/12 which is connected to Cisco 1841 fa0/0 router by mean of cat5e cable.I did change the cable from cat5e to cat 6 and tried to increase hold queue to 4096 and to tweak wrr queue bandwidth

View 4 Replies View Related

Cisco Switching/Routing :: Configuring EtherChannel Between 3750-X Cross-stack And 6509E Switch?

Mar 3, 2013

configuring EtherChannel between 3750-X cross-stack and 6509E switch. I use two ports on 3750s, and two ports on 6509. I just need it as a trunk. For some elusive reason one port on 3750 keeps being err-disabled, and one on 6509 notconnected.
 
Here is what I did so far.
 
3750
!
interface GigabitEthernet1/0/22
description ***VSS-RNOC-link***
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 2

[code]....
 
Problem with :

GigabitEthernet1/0/22 is down, line protocol is down (err-disabled)
GigabitEthernet2/1/29 is down, line protocol is down (notconnect)
 
I tried shutting them down, then no shutting them again. Didn't work.

View 11 Replies View Related

Cisco Switching/Routing :: 6509-E Supported Switch Modules With Latest Stable IOS 12.(33)

Oct 14, 2012

I recently ran an upgrade on my 6509-E's and when the first switch came back up, 3 of the 10/100 switches that were in the chassis did not power on. After further investigation, these models are not supported by this latest IOS version. The module # is : WS-X6248-RJ-45
 
We have one WS-X6348-RJ-45 and since it was a few weeks ago I did this I can't remember for sure but I believe this one came up.
 
Where can I found the information regarding this being unsupported but I know it is out there and any page that showed me that this was unsupported with the latest stable IOS of 12.(33).
 
In addition to this question, I have approval to purchase some newer gigabit switches that will be supported by this new IOS version and hopefully at least the next few over the next few years. Which specific gig models are currently and hopefully should be supported for the next few years? I don't need PoE or anything spectacular, just regular switches that are attached to either servers or virtual hosts. I've been looking at the lists of what is out there and it seems like there are hundreds of different models and it is becoming difficult to determine what is what.

View 1 Replies View Related

Cisco Switching/Routing :: Stack C3750G And C3750X - Major Version Mismatch

Jun 11, 2013

I'm trying to stack 3750G & 3750X. As discussed in previous threads I am aware of that the version need to match.
 
Here the switch details:
 
Switch Ports Model              SW Version                SW Image
------ ----- --------------             ----------
* 1 24    WS-C3750G-24T      12.2(55)SE7             C3750-IPBASEK9-M
---------------------------------------------------------------------------------------------------------------
* 1 54      WS-C3750X-48      12.2(55)SE7           C3750E-IPBASEK9-M
 
I have changed the universal IOS on the 3750X to IP base..but they still wont come up as a stack. On the 3750X I don't see any log entry, on 3750G (major version mismatch).

View 4 Replies View Related

Cisco Switching/Routing :: 3750 - Major Version Mismatch On Identical Switches

Apr 3, 2012

We have bought four identical 3750X switches with identical SW-images: 12.2(55)SE3          C3750E-UNIVERSALK9-M
 
We initially connected two switches, this resulted in forming a stack.With the other two switches we wanted to do the same thing. However, we received the following message:
 
%STACKMGR-5-MAJOR_VERSION_MISMATCH: Major Version Mismatch (Local 1 - Received 6) with neighbor-1
 
Both switches will not see each other and the output of show switch stack-ports shows only one switch and both stack ports as being Down.
 
I did some digging using the show platform stack-manager all command to find out that three of the 3750X's have the stack version number 1.45 and one has 6.45. This would obviously indicate the reason behind the mismatch, but the SW-versions on all new switches are identical!
 
Checking the CISCO site explains that mismatching of Major version is critical:
 
Major Version Number Incompatibility Among Switches

Switches with different major Cisco IOS software versions usually have different stack protocol versions. Switches with different major version numbers are incompatible and cannot exist in the same switch stack.
 
That's all I could find. Nothing about changing the major version number, so all I can suspect is that IOS version needs to be the same.

View 5 Replies View Related

Cisco Switching/Routing :: Getting Error In 4948 Switch

Mar 13, 2013

My cisco 4948 switch is generating the below error,how do i troubleshoot this error.

*Mar 13 00:09:33.451: %C4K_L2MAN-6-INVALIDSOURCEADDRESSPACKET: (Suppressed 14 times)Packet received with invalid source MAC addre ss (00:00:00:00:00:00) on port Gi1/37 in vlan 1Gi1/37- to this port another 2950 switch is connected by trunk link.and to this switch end host is connected i.e.thin client

View 3 Replies View Related

Cisco Switching/Routing :: 4507 Getting Error While Configuring A Switch

Nov 8, 2011

I have a 4507 cisco switch loaded with two sup-modules.. [code]

View 5 Replies View Related

Cisco Switching/Routing :: SSH Error With 4507 Edge Switch

Sep 4, 2012

i have a problem with a cisco cat. 4507 edge switch as when i have a login ssh session to the switch the supervisor engine restart and the redundant Sup. engine becomes the active and so on this problem mainly happen when i have multible SSH session to the switch and it happened very rarely with a single ssh login
 
the ios version i use is cat4500-entservicesk9-mz.122-54.SG which im using on all my edge switch and they are all working fine excpt this one

View 1 Replies View Related

Cisco Switching/Routing :: C3560E Difference Between Two Temperature

Mar 17, 2013

What is the difference between Operating temperatue & storage temperature of switch C3560E ?

View 2 Replies View Related

Cisco Switching/Routing :: Error Lights Signal On Switch 2960

Feb 22, 2013

I have a switch connect to 2 backbone(BB).
 
Now i saw the lights when connect to BB1 is not light but i do not know which command will show the root cause or troubleshooting.
 
I want to know its caused by hardware, physical port or whatever. Any on can sharing the experiences how to show and troubleshooting this issue?
 
I also checked the connection and port 1g is fine. Show tech-support is alread here.

View 10 Replies View Related

Cisco Switching/Routing :: Error In Logging Observed On 6513 Switch

Jul 15, 2012

I have been getting the logs in my cisco 6513 switch [code] On further investigating in the module 9 which has a DFC card also , we found the source of this error whether it is a source of any upcoming potential impact or can be simply ignored

View 3 Replies View Related

Cisco Switching/Routing :: Nexus 7000 Switch Error Logs

Nov 21, 2012

We are getting some error logs on Nexus VDC,as follows:2012 Nov 23 08:49:11 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 6 times 2012 Nov 23 08:50:21 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 7 times 2012 Nov 23 08:49:11 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 6 times2012 Nov 23 08:50:21 N7K_B-Network_Center_B %$ VDC-3 %$ last message repeated 7 times.

View 1 Replies View Related

Cisco Switching/Routing :: Power Supply Error Switch 3750

Dec 3, 2011

power supply problem...?Switch cisco WS-C3750-24P is showing "Unavail" from sh env all.Switch3750#sh env all FAN is OK,TEMPERATURE is OK,SW  PID,Serial#     Status Sys Pwr  PoE Pwr  Watts,Does it means that power supply 1 was removed? failed?,Do you know about another command to see more details?

View 3 Replies View Related

Cisco Switching/Routing :: 1841 No Error On Connected Switch Interface

Feb 18, 2013

We are using Cisco Router 1841 and users reporting issue related to VoIP. After investigation, seeing input errors on Router LAN interface, but there is no error on connected switch interface. [code]

View 2 Replies View Related

Cisco Switching/Routing :: Ping Error Between Two 6504 Trunking Switch?

Oct 17, 2012

We have network topo ( attach file)Two switch run VRRP, if I ping 10.0.10.3 from switch SW-6504-01 with source 10.0.10.2, ping lost one packet  every 10 packets.We have other interface vlan with same problem
 
this is some config:

!
interface Port-channel1
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
no ip address
!
interface GigabitEthernet3/47

[code]....

View 5 Replies View Related

Cisco Switching/Routing :: Nexus 7000 To Know Ambient Temperature

Nov 2, 2012

I need to know how is the ambient temperature for the Nexus 7000 switches to plan a new datacenter. In the datasheet I found the following information regarding this topic:"GR-63-CORE Network Equipment Building Standards (NEBS) specification published by Telcordia Technologies in Section 4.1.2". How are the specification for temperature in this standard?

View 1 Replies View Related

Cisco Switching/Routing :: WS-C2960-24TC-L Display Temperature

May 19, 2013

I have an issue with one of our switches, switch model WS-C2960-24TC-L, i am not able to display switch temperature as below,
 
Switch#sh verCisco IOS Software, C2960 Software (C2960-LANBASEK9-M), Version 15.0(2)SE2, RELEASE SOFTWARE (fc1)Technical Support: URL ) 1986-2013 by Cisco Systems, Inc.Compiled Tue 05-Feb-13 12:41 by prod_rel_team(code)

View 2 Replies View Related

Cisco Switching/Routing :: High Discard Rate Error From LMS For Switch 2950

Feb 13, 2012

As always, the Cisco LMS is keep sending the follwoing high discard error from the Cisco switches WS-C2950T-24:
 
EVENT ID               = 0004SX3
ALERT ID               = 00019LF
TIME                   = Tue 14-Feb-2012 08:56:35 GMT

[Code].....

View 4 Replies View Related

Cisco Switching/Routing :: Error While Upgrading IOS On 2960 Switch Using Tftp Server

Apr 29, 2013

I am trying to copy IOS from my TFTP server which is on my laptop to cisco 2960 switch
 
I am able to ping to switch from my laptop, connectivity is fine, tftp server is running
 
Current Image on Switch --> C2960-LANBASE-MZ.122-25.SEE3.bin -->  trying to upgrade to --> c2960-lanbasek9-mz.122-53.SE2
 
I am getting below error when trying to upgarde IOS:
 
2960-SW#copy tftp: flash:           
Address or name of remote host []? 10.1.x.x
Source filename []? c2960-lanbasek9-mz.122-53.SE2

[Code].....

View 6 Replies View Related

Cisco Switching/Routing :: Error Logs On Nexus 7K Switch / %SYSMGR-2-STANDBY_BOOT_FAILED

Oct 29, 2012

We are getting some error logs on Nexus switch 7K.
 
Loggs:
----------
2012 Oct 30 22:36:07 SWITCH %CMPPROXY-STANDBY-2-LOG_CMP_UP: Connectivity Management processor(on module 6) is now UP
2012 Oct 30 22:36:40 SWITCH %SYSMGR-2-GSYNC_SNAPSHOT_SRVFAILED: Service "ipqosmgr" on active supervisor failed to sto
re its snapshot (error-id 0x40480005).
2012 Oct 30 22:36:40 SWITCH %SYSMGR-2-STANDBY_BOOT_FAILED: Standby supervisor failed to boot up.
2012 Oct 30 22:36:42 SWITCH %PLATFORM-2-MOD_REMOVE: Module 6 removed (Serial number JAF1550ATBR)
2012 Oct 30 22:42:08 SWITCH %BOOTVAR-5-NEIGHBOR_UPDATE_AUTOCOPY: auto-copy supported by neighbor supervisor, starting

[code]....

View 8 Replies View Related

Cisco Switching/Routing :: 2960 / Error (Unknown Cmd) And (line Too Long) Switch

Dec 28, 2011

when I want to recover my 2960 switch in rommon mode with xmodem command, It shows me these errors. when I reset the switch, still shoes these errors:

Unknown cmd: 1;2c1;2c[?1;21;2c[?1;21;2c[?1;2;21;2c[?1;2[
switch: ?1;2c[?1;21;2c[?1;21;2c
switch: ccknown cmd:
*** line too large *****tch: c1;2[?1
switch:
 Unknown cmd: cc?1;2c[?1;21;2c[

[code]....

View 1 Replies View Related

Cisco Switching/Routing :: Inlet And Outlet Temperature Sensor In 6500

Mar 9, 2013

Below module showing inlet and outlet temperature N/o.How to find the issue related to sensor in the module or something else to troubleshoot in the module to find the issue.

View 5 Replies View Related

Cisco Switching/Routing :: 6509E With 2 Sup 2T Cards

Apr 30, 2012

I have a new 6509E with 2 sup 2T cards. The 10GE ports on both sup cards will connect to 2 5548s. Can i connect the management interface on the new 6509E to the old 6509 until i free up space to bring the line cards over?

View 2 Replies View Related

Cisco Switching/Routing :: 10G Upgrade For 6509E

Dec 9, 2012

I have a couple of 6509-E combined in a VSS system. I need to upgrade them to support 8 (or 16 at max) 10G uplinks. I already used the two built-in VS-S720-10G fiber connectors for VSL links. Which Ethernet modules do you suggest to use? are there any related upgrades that I have to do? 
 
supervisor used: VS-S720-10G
Chassis: WS-C6509-E

View 2 Replies View Related

Cisco Switching/Routing :: Getting Physical Port Failure Error On Nexus 7010 Switch

Jul 9, 2012

I've Nexus 7010 switch installed in my DC. I've conncected Cisco router to one of the Ports. On the same port I'm getting following error message and hence, unable to form EIGRP neighborship.
 
DR-CORE-SW-S01-NEXUS7K %MODULE-2-MOD_SOMEPORTS_FAILED:
Module 1 (serial: JAF*******NGK) reported failure on ports 1/2-1/2 (Ethernet) due
to R2D2 : Speed patch failed - no frames transmitted in device 143 (error 0xc8f0
1273)

View 1 Replies View Related

Cisco Switching/Routing :: Industrial Ethernet 2000 Series Temperature Ranges

Jul 24, 2012

Any explanation regarding these different operating temperature ranges? I would think it doesn't matter the enclosure that the switch is in, it will either work or fail at a certain temperature.,-40C to +70C (Vented Enclosure Operating),-20C to +60C (Sealed Enclosure Operating), -34C to +75C (Fan or Blower equipped Enclosure Operating).

View 0 Replies View Related

Cisco Switching/Routing :: Nexus 5k Power Down Due To Temperature Sensor Policy Trigger

Dec 2, 2012

We have a nexus 5k, and it kind of got hung today... it is running. Version 5.1(3)N2(1b) the reset reason shows.Power down due to temperature sensor policy trigger.It doesn't look documented. What policy is it referring to? not sure if this is an IOS bug ?

View 1 Replies View Related

Cisco Switching/Routing :: Migrating Cat 6503-E VSS To Cat 6509E VSS

Aug 7, 2012

I want to migrate a Cat 6503-E VSS to Cat 6509E VSS. We plan to use the same supervisor that we have on the Cat6503E, for minimizing the configuration change on the Doing this, the vss link will need to be changed, due to the fact that the supervisor slot will change with the Cat 6509, slot 5 instead of 1.

Question: is there a way to just change the vsl-link interface on a existing VSS ?

View 3 Replies View Related

Cisco Switching/Routing :: WS-C4510R+E Modules

Feb 7, 2013

I have a WS-C4510R+E with
 
Mod Ports Card Type                              Model              Serial No.
---+-----+--------------------------------------+------------------+-----------
1    48  10/100/1000BaseT Premium POE E Series  WS-X4748-RJ45V+E   CAT1612L1JD
2    48  10/100/1000BaseT Premium POE E Series  WS-X4748-RJ45V+E   CAT1612L1JW
3    12  10GE SFP+                              WS-X4712-SFP+E     CAT1622L0SC
4    12  10GE SFP+                              WS-X4712-SFP+E     CAT1622L0RM
5     4  Sup 7-E 10GE (SFP+), 1000BaseX (SFP)   WS-X45-SUP7-E      CAT1620L1UJ
6     4  Sup 7-E 10GE (SFP+), 1000BaseX (SFP)   WS-X45-SUP7-E      CAT1620L1Z2
 
Can i add two WS-X4712-SFP+E and two 10 GE ethernet module also?
 
Is there 10GE ethernet module with WS-C4510R+E.

View 2 Replies View Related

Cisco Switching/Routing :: Isolating Two Different VLANs With Subnets On 6509E Sup 2T

Oct 1, 2012

I have a pair of Core VSS 6509E SUP 2T. Two different LANs, two diff. Subnets. larger LAN has been connected to the VSS pair usng normal SVI and Post-Channles (has lots of closets 3750 stacks) and no problem. Second LAN, two closets, stacked and connected to each other via Port channel and trunk + SVI interfaces. Now, I have SVI interfaces for both LANs on teh VSS pair and that is causing traffic from one LAN to jump over to the other VLAN and rightly so because the VSS pair see both subnets as directly connected subnets. I was wondring if I delete the SVI for the second LAN and only keep the L2 VLAN this will be resolved> The reason for the second LAN to connect to the VSs pair is only that It has to go through the VSS pair to get to the WAN router (both LANs will go out through this Same WAN router) but WAN router is not my concern at this time. I need to isolate these two LANs/subnets traffic so no one VLAM traffic jumps over the other.I have also thought about VRF but at this point I am not sure if teh 3750 stacks supports VRF and if it does how to implement VRF on the second and samller LAN to just allow it go through the VSS pair in order to get to the WAn router.

View 13 Replies View Related

Cisco Switching/Routing :: Cat 6509E 6Kw PS AC Input Level Verification

Oct 27, 2011

I have a 6509E switch with dual 6Kw power supply that is logging "Power supply 1 input has changed.  Power capacity adjusted to 2671.20W" then will bounce back to normal at random times from 1sec to 10sec. Is there a command to check what each input level of the power supply to try to identify possibly which source is causing the problem? The power supply input lights remains green while this is occuring.

View 3 Replies View Related